Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Beamed Energy and Communications Optical Node (BEACON) Demonstrator

Due to long shadow periods (2 weeks or greater) on the south pole, concepts to raise solar arrays to a sufficient height at specific locations have shown the capability to provide power to surface users for much longer periods. Such a tower can also provide a 3rd Generation Partnership Project (3GPP) service for users up to 10 km away, dependent on terrain. An option to deliver power, albeit with low efficiency, using a laser beam coupled with the tower height could provide mobile and fixed users power during darkness, reducing their battery requirements. A demonstration of these technologies in the lunar environment is crucial to support future Artemis campaigns as well as potential emerging lunar infrastructures. A demonstrator design of a 15 m deployed boomon the south pole has been shown to enable both the gathering of kilowatts of power and the provision of 3GPP relay and backhaul given an appropriate lunar location. Using a laser to send power to a photovoltaic receiver has been proposed to transmit electrical power on the moon, particularly for applications such as powering a rover in near-polar permanently shadowed regions (PSR) where solar power is not available. In this work, the Compass team performed a conceptual engineering design study of a near-term laser surface-to-surface power beaming and relay station using a tower to simultaneously carry the power source (Vertical Solar Array Technologies (VSAT)[1]), the 3GPP relay antenna, and the laser telescope.

Deployable solar array tower laser beamed power 3G↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An operating 200 kW horizontal axis wind turbine

Output from the 200-kilowatt machine will be enough to meet the power requirements of about 60 families. The experimental wind turbine generator (WTG) is a two-bladed, horizontal-axis, rotor system driving a synchronous electric generator through a step-up gear box located within a nacelle. The nacelle is mounted on top of a 100-foot tower with the rotor located downwind from the tower. The 200-kilowatt rated power output of the wind turbine is achieved at a turbine rotor speed of 40 rpm and a rated wind speed of 18.3 mph. The rated wind speed is defined as the lowest wind speed at which full power is achieved. Attention is given to operational details, aspects of blade design, blade fabrication, the use of strain gages, questions of aeroelastic stability, and an early analysis of test data.

Hunnicutt, C. L.↗

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software Design for the Supervised Autonomous Assembly of a Tall Lunar Tower

Tall towers enable a wide-ranging set of capabilities on the lunar surface including communication, navigation, surveillance, power generation, and more. The Tall Lunar Tower project at NASA Langley Research Center is focused on the design, modeling, fabrication, and testing of an engineering development unit to assemble a tall tower through supervised autonomous operations. In this paper, the software design for the supervised autonomous assembly of a tall lunar tower is presented. The paper includes a high-level description of the concept of operations, the agents, and an overview of the software architecture.

Moon↗

Software Design for the Supervised Autonomous Assembly of a Tall Lunar Tower Presentation

Tall towers enable a wide-ranging set of capabilities on the lunar surface including communication, navigation, surveillance, power generation, and more. The Tall Lunar Tower project at NASA Langley Research Center is focused on the design, modeling, fabrication, and testing of an engineering development unit to assemble a tall tower through supervised autonomous operations. In this paper, the software design for the supervised autonomous assembly of a tall lunar tower is presented. The paper includes a high-level description of the concept of operations, the agents, and an overview of the software architecture.

TLT↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Tall Lunar Tower: An Autonomously Assembled Tower for Early Lunar Infrastructure

The Tall Lunar Tower (TLT) In-Space Assembly (ISA) team aims to design, model, fabricate, autonomously assemble, and characterize a TLT engineering development unit (EDU). The autonomous assembly of a tower also demonstrates a cross-cutting technology that can be applied to other lunar structures, such as blast shields, radiation shelters, and safe havens.

In-Space Assembly↗

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site

The Raft River geothermal field is the site of an innovative Department of Energy Enhanced Geothermal System (EGS) project to determine the viability of using combined thermal and hydraulic stimulation techniques to improve energy production. Well RRG-9 is currently undergoing a stimulation program using injectate from the US Geothermal Raft River Power Plant and cold water from a cooling tower make-up water well. The stimulation began on 13 June 2013 with injection from the power plant at a temperature of about 39 °C and a pressure of 275 psig. Next, two positive displacement plunger type pumps were used to increase the injection pressure and flow rate for about one month. The highest rate achieved was 258 gpm at a pressure of 741 psig. During this time, fluid from the cooler water well was injected for about 2 weeks at various pressures. Then, the pumps were removed and plant injection resumed on 25 September. Plant injection will continue until the spring of 2014, when a high pressure hydraulic stimulation will be conducted. A series of seismic monitoring stations deployed around the well are providing data on seismic events occurring at the site. Over the past year, 51 microseismic events have been recorded, all less than Magnitude 1. During injection, several diagnostic tests were conducted to gain a better understanding of the well and reservoir. A step-rate test was performed on 22 August to measure the in-situ stress and aid in modeling in-situ fractures. A tracer was injected into the well on 9 September. No tracer was detected in adjacent production wells after several months. A second borehole televiewer survey was conducted for comparison to pre-stimulation images. Here, a third borehole televiewer survey is planned after the high pressure stimulation. Injection test data is evaluated in real time. A modified Hall plot analysis indicates the effective permeability is increasing. The injectivity index supports the results of the modified Hall plot analysis. As the thermal stimulation has continued, the injectivity index has consistently followed an upward trend from 0.1 gpm/psi to 0.53 gpm/psi.

enhanced geothermal systems↗

An Assessment of Persistent Acoustic Monitoring of a Nuclear Reactor during Full Power Generation

Persistent low-frequency (<180 Hz) acoustic detection took place within the boundaries of Oak Ridge National Laboratory to monitor full power operations of the High Flux Isotope Reactor. Three acoustic sensors were installed at distances of 69, 101, and 914 m from the northeast corner of the cooling towers to monitor and assess four reactor power generation cycles. Features were extracted from power spectral density calculations where data were collected during reactor on and off operations. Diverse spectral features were present during full reactor power, including a 21.4 Hz fundamental frequency and ascending harmonics. Using bandpass filters, these related frequencies were isolated and summed, and the root mean square energy was calculated. The method of isolating and summing characteristic features provided a significant improvement in identifying acoustic behavior related to reactor power when the raw signals were obscured by noise.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interference from the Robledo DSN Transmitters to Central Madrid IMT-2000/UMTS System through Terrain Diffraction at S-Band

This study evaluates the possible interference from DSN Robledo 70-m transmitter with Madrid IMT-2000/UMTS wireless users in Spain as both systems will share the same frequency band. Using the effective earth radius, the 50 km terrain profile between Robledo and Madrid is modified and reconstructed. The diffraction propagation losses due to mountain peaks are calculated for the receivers in Madrid urban area. The mountains along the path are simplified into a rounded knife-edge and a rounded obstacle. The results show that for a near surface receiver (1.5 m above the ground) in Madrid, interference signal powers received are less than -135 dBm, which is far below the -109 dBm, the IMT-2000 wireless phone threshold. When a receiver is located at about 40 m above the ground (e.g., the top of Clock Tower of Cibeles Palace), diffraction will generate interference power less than -115 dBm. We find that our calculation results are basically consistent with those from the Longley-Rice model, while the latter has smaller loss because of the low resolution terrain profile used. As a comparison, we also find that the measurements of interference powers of -121.2 dBm at the top of Clock tower is in the range of the estimation. We conclude that the interference through the diffraction mechanism will not cause any problem to IMT-2000/UMTS users at near the surface of Madrid urban area.

telecommunications↗

Structural Sizing of a 50-m-Tall Thermoplastic Composite Solar Array Truss Tower Structure for the Lunar South Pole

At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.

Thermoplastic composites↗

Structural Sizing of a 50-m-Tall Thermoplastic Composite Solar Array Truss Tower Structure for the Lunar South Pole

At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.

Thermoplastic composites↗

Structural Sizing of a 50-m-Tall Thermoplastic Composite Truss Tower Structure for the Lunar South Pole

At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.

Thermoplastic composites↗

NASA Lewis Research Center photovoltaic application experiments

The NASA Lewis Research Center has installed 16 geographically dispersed terrestrial photovoltaic systems as part of the DOE National Photovoltaic Program. Four additional experiments are in progress. Currently, operating systems are powering refrigerators, a highway warning sign, forest lookout towers, remote weather stations, a water chiller and insect survey traps. Experiments in progress include the world's first village power system, an air pollution monitor and seismic sensors. Under a separate activity, funded by the U.S. Agency for International Development, a PV-powered water pump and grain grinder is being prepared for an African village. System descriptions and status are included in this report.

Ratajczak, A.↗

Robust multi‐loop control of a floating wind turbine

Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.

Stockhouse, David↗

Data acquisition and analysis in the DOE/NASA Wind Energy Program

Four categories of data systems, each responding to a distinct information need are presented. The categories are: control, technology, engineering and performance. The focus is on the technology data system which consists of the following elements: sensors which measure critical parameters such as wind speed and direction, output power, blade loads and strains, and tower vibrations; remote multiplexing units (RMU) mounted on each wind turbine which frequency modulate, multiplex and transmit sensor outputs; the instrumentation available to record, process and display these signals; and centralized computer analysis of data. The RMU characteristics and multiplexing techniques are presented. Data processing is illustrated by following a typical signal through instruments such as the analog tape recorder, analog to digital converter, data compressor, digital tape recorder, video (CRT) display, and strip chart recorder.

Neustadter, H. E.↗