Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Loads and Aeroacoustics Between Upwind and Downwind Wind Turbine Rotors

This presentation discusses the motivation, preparation, risk mitigation, execution, and results of a full-scale experiment where the rotor of a 1.5 megawatt wind turbine was operated in a downwind configuration. The experiment took place at the National Renewable Energy Laboratory Flatirons Campus in Colorado, USA, and collected conventional loads and power together with acoustic measurements from an array of four microphones. Results from load simulations complement the experiment. Fatigue loads and performance are compared between 410 minutes of downwind operation with 960 minutes of conventional upwind operations. Downwind operations cause an increase in damage equivalent loads in a few load channels. Damage equivalent load of blade root flapwise and edgewise moment and the damage equivalent load of tower base fore aft moment increase between 2% and 20% depending on the wind speed. The comparison in active power is less conclusive, but experimental results show more power in downwind than predicted by simulations. In terms of acoustics, the overall sound pressure levels are similar between upwind and downwind, but downwind worsens the metrics describing amplitude modulation.

aeroacoustics↗

Dynamic Model Development of a Wind Power Plant Using Neural Net Method to Forecast Wind Power Output (CRADA Final Report)

This project is intended to model wind power plant based on monitored data at the wind power plant. This project will promote the university research in Renewable Energy area and trains the future highly qualified engineers. The dynamic model will be based on neural net model with the input from the two met towers (12 inputs), and the number of turbines in operation (one input). The overall input will be 13 inputs to drive the simulations. The output power at the point of interconnection will be used to tune the neural net weight coefficients. Two neural net concepts will be investigated (the back propagation neural net and the dynamic recurrent neural net with feedback).

17 WIND ENERGY↗

Conservation laws and effective hadronization models

Hadronization models based on local string-breaking dynamics are typically Markovian by construction, yet the physical ensemble of final states is shaped by global constraints that couple the entire fragmentation trajectory. Recasting hadronization as a conditioned stochastic diffusion process provides a precise mathematical resolution to this tension. In particular, this language reveals explicitly that constraints stemming from conservation laws induce non-Markovian correlations between otherwise independent fragmentation steps, and that these correlations can be absorbed exactly into a renormalization of the local dynamics through a Doob $h$-transform. We develop this formalism for a $q\bar{q}$ string in the chiral limit, where the longitudinal-transverse factorization of the Lund kernel becomes exact, enabling systematic power counting and clean ultraviolet (UV)/infrared (IR) separation. The dynamics organize naturally into a tower of effective theories distinguished by the remaining string mass, spanning a UV fixed point with scale-invariant transport coefficients, an intermediate regime where transverse phase space induces controlled running, and an IR boundary layer where non-local effects enter at leading order. The tower exhibits genuine Wilsonian structure, including $β$-functions, anomalous dimensions, and systematic matching conditions. The resulting framework achieves a clean factorization of universal microscopic fragmentation dynamics from infrared constraint effects, and opens new directions for both the theoretical analysis and practical simulation of hadronization.

Menzo, Tony [Alabama U.; Fermilab] (ORCID:00000002↗

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load assessment of a wind farm considering negative and positive yaw misalignment for wake steering

Wake steering strategies are employed to increase the overall power production of wind farms by deflecting wakes of upstream turbines away from downstream ones. The gain in net power comes at the expense of increased fatigue loads experienced by downstream turbines. In this work we investigate performance and fatigue loading characteristics of a small farm consisting of five aligned International Energy Agency Wind Technology Collaboration Programme 15 MW wind turbines. A parametric study is performed where, for every wind direction from −20 to 20°, the yaw misalignment angle varies from −25 to 25°. This setup allows us to investigate asymmetries and identify optimal conditions for a given wind direction. In general, we find that positive yaw configurations are preferred and that yaw configurations that result in attractive power differences when compared to a baseline no-yaw scenario (25 %) come with significant increase in fatigue loading (we use the standard deviation and damage-equivalent load (DEL) of the blade-root, low-speed shaft, and tower-base moments as proxies for fatigue load). We find that for any given positive wind inflow angle, yaw angles between −2.5 and 15° yield power differences of 10 %–20 % over a no-yaw baseline, and positive yaw is preferred because of lower fatigue loading. For any given negative wind inflow angles, positive yaw also results in lower magnitudes of standard deviation and DEL for the channels investigated. A small power loss of up to 2 % is observed for some positive yaw angles under negative wind directions (as compared to symmetric negative yaw and positive wind cases), but improvements in terms of loads exceed 25 % and may be enough to justify a positive yaw configuration under negative winds as well. We show that such behavior can be explained by partial waking and the direction of the rotation of the rotor.

17 WIND ENERGY↗

Nonsteady Load Responses to Mountain-Generated Turbulence Eddies on the DOE 1.5 MW Wind Turbine at the National Wind Technology Center

Field data collected from the NREL/GE 1.5MW wind turbine and met tower at the NREL Wind Technology Center near Boulder, Colorado from June-October 2018 were analyzed to quantify the impacts of turbulence eddies on the load responses measured from sensors on the main shaft, blade and tower. The passage of individual mountain-generated eddies from the met tower to the wind turbine were critically determined by correlating the optimal time shifts in signal between met tower and nacelle anemometers with mean advection time. Loading responses from mountain eddy passage were compared with atmospheric eddies from the north/south, unimpeded by the mountains, and found to be similar. Whereas time variations in torque were highly correlated with time changes in horizontal eddy velocity, the out-of-plane bending moments on the main shaft (directly forcing the main bearing) were uncorrelated with horizontal eddy velocity. This result is consistent with a previous LES study indicating that the main bearing is forced by asymmetrical interactions between the rotor and turbulence eddies, while power fluctuations respond primarily to advective eddy velocity. Surprisingly, the nacelle anemometer produced statistics very similar to the met tower.

ENGINEERING,WIND ENERGY↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Development of a Metocean Reference Site near the Massachusetts and Rhode Island Wind Energy Areas

This project developed the first long-term U.S.-based offshore MetOcean Reference Site (MORS-1) by capitalizing on a unique combination of one of the few existing publicly available offshore wind energy metocean observational campaigns in the United States and the only existing research-grade offshore fixed tower. Data collected at MORS-1 has facilitated improved wind resource assessments, improved short-term power production estimates, and reduced costs for sensor validation and calibration efforts, which translate into reduced overall wind energy project risk and cost for developers. Now operational, MORS-1 serves the needs of both industry and researchers using a nonprofit, joint industry-academic partnership model. Led by the Woods Hole Oceanographic Institution, the MORS-1 development effort focused on creating both a recognized organizational structure that will ensure support of the MORS-1 by the wider wind energy industry and research community, and a highly validated data collection and sensor validation facility that will serve as the premier location for cost- and uncertainty-reducing resource characterization and research efforts.

17 WIND ENERGY↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Using the Carbon Capture Simulation Initiative (CCSI) Tool to Design the Experiments in the Parametric Campaign of a Novel Compact Absorber for Carbon Capture

Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.

20 FOSSIL-FUELED POWER PLANTS↗

AmeriFlux FLUXNET-1F CA-SCB Scotty Creek Bog

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SCB Scotty Creek Bog. This is the FLUXNET version of the carbon flux data for the site CA-SCB Scotty Creek Bog produced by applying the standard ONEFlux (1F) software. Site Description - The Scotty Creek bog flux tower is located in an organic-rich collapse-scar bog about 50 km south of Fort Simpson in the Taiga Plains of the Mackenzie watershed. The tower was installed in 2014 and operates an open-path EC system year-round running on solar power only. The collapse-scar bog is treeless and free of permafrost.

Sonnentag, Oliver↗