Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Hydrogen no-vent fill testing in a 34 liter (1.2 cubic foot) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 34 liter stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Maximum pressure within the receiver tank was limited to 0.207 MPa (30 psia), and fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the various parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls and from ullage compression.

Moran, Matthew E.↗

Test description and preliminary pitot-pressure surveys for Langley Test Technique Demonstrator at Mach 6

A propulsion/airframe integration experiment conducted in the NASA Langley 20-Inch Mach 6 Tunnel using a 16.8-in.-long version of the Langley Test Technique Demonstrator configuration with simulated scramjet propulsion is described. Schlieren and vapor screen visualization of the nozzle flow field is presented and correlated with pitot-pressure flow-field surveys. The data were obtained at nominal free-stream conditions of Re = 2.8 x 10 exp 6 and a nominal engine total pressure of 100 psia. It is concluded that pitot-pressure surveys coupled to schlieren and vapor-screen photographs, and oil flows have revealed flow features including vortices, free shear layers, and shock waves occurring in the model flow field.

Everhart, Joel L.↗

Shearography NDE of NASA COPV

1. 21 Composite Over-wrapped Pressure Vessels (COPV) consisting of Kevlar Space Shuttle Fleet Leaders and Graphite COPV were inspected at NASA WSTF, NM from Sept. 12 through Sept 16. 2. The inspection technique was Pressurization Shearography, tests designed to image composite material damage, degradation or design flaws leading to stress concentrations in the axial or hoop strain load path. 3. The defect types detected consisted of the following: a) Intentional impact damage with known energy. b) Un-intentional impact damage. c) Manufacturing defects. 4. COPV design features leading to strain concentrations detected include: a) Strain concentrations at bosses due to fiber closure pattern. b) Strain concentrations in body of COPV due to fiber wrap pattern. c) Strain concentrations at equator due to liner weld/fiber lay-up.

Newman, John W.↗

Pressure probe study of the water relations of Phycomyces blakesleeanus sporangiophores

The physical characteristics which govern the water relations of the giant-celled sporangiophore of Phycomyces blakesleeanus were measured with the pressure probe technique and with nanoliter osmometry. These properties are important because they govern water uptake associated with cell growth and because they may influence expansion of the sporangiophore wall. Turgor pressure ranged from 1.1 to 6.6 bars (mean = 4.1 bars), and was the same for stage I and stage IV sporangiophores. Sporangiophore osmotic pressure averaged 11.5 bars. From the difference between cell osmotic pressure and turgor pressure, the average water potential of the sporangiophore was calculated to be about -7.4 bars. When sporangiophores were submerged under water, turgor remained nearly constant. We propose that the low cell turgor pressure is due to solutes in the cell wall solution, i.e., between the cuticle and the plasma membrane. Membrane hydraulic conductivity averaged 4.6 x 10(-6) cm s-1 bar-1, and was significantly greater in stage I sporangiophores than in stage IV sporangiophores. Contrary to previous reports, the sporangiophore is separated from the supporting mycelium by septa which prevent bulk volume flow between the two regions. The presence of a wall compartment between the cuticle and the plasma membrane results in anomalous osmosis during pressure clamp measurements. This behavior arises because of changes in solute concentration as water moves into or out of the wall compartment surrounding the sporangiophore. Theoretical analysis shows how the equations governing transient water flow are altered by the characteristics of the cell wall compartment.

NASA Discipline Number 40-30↗

Pressure Modulator Radiometer (PMR) tests

The pressure modulator technique was evaluated for monitoring pollutant gases in the Earth's atmosphere of altitude levels corresponding to the mid and lower troposphere. Using an experimental set up and a 110 cm sample cell, pressure modulator output signals resulting from a range of gas concentrations in the sample cell were examined. Then a 20 cm sample cell was modified so that trace gas properties in the atmosphere could be simulated in the laboratory. These gas properties were measured using an infrared sensor.

Odell, E. L. G.↗

Computation of turbine flowfields with a Navier-Stokes code

A new technique has been developed for the solution of the incompressible Navier-Stokes equations. The numerical technique, derived from a pressure substitution method (PSM), overcomes many of the deficiencies of the pressure crrection method. This technique allows for the direct solution of the actual pressure in the form of a Poisson equation which is derived from the pressure weighted substitution of the full momentum equations into the continuity equation. In two-dimensions a turbine flowfield, including heat transfer, has been computed with this method and the prediction of the cascade performance is presented. The extension of the pressure correction method for the solution of three-dimensional flows is also presented for laminar flow in an S-shaped duct and turbulent flow in the end-wall region of a turbine cascade.

Hobson, G. V.↗

Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Low Pressure Casting

Systems and methods to fabricate objects including metallic glass-based materials using low-pressure casting techniques are described. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: introducing molten alloy into a mold cavity defined by a mold using a low enough pressure such that the molten alloy does not conform to features of the mold cavity that are smaller than 100 microns; and cooling the molten alloy such that it solidifies, the solid including a metallic glass-based material.

Hofmann, Douglas C.↗

Pressure Distribution and Air Data System for the Aeroassist Flight Experiment

The Aeroassist Flight Experiment (AFE) is designed to provide critical flight data necessary for the design of future Aeroassist Space Transfer Vehicles (ASTV). This flight experiment will provide aerodynamic, aerothermodynamic, and environmental data for verification of experimental and computational flow field techniques. The Pressure Distribution and Air Data System (PD/ADS), one of the measurement systems incorporated into the AFE spacecraft, is designed to provide accurate pressure measurements on the windward surface of the vehicle. These measurements will be used to determine the pressure distribution and air data parameters (angle of attack, angle of sideslip, and free-stream dynamic pressure) encountered by the blunt-bodied vehicle over an altitude range of 76.2 km to 94.5 km. Design and development data are presented and include: measurement requirements, measurement heritage, theoretical studies to define the vehicle environment, flush-mounted orifice configuration, pressure transducer selection and performance evaluation data, and pressure tubing response analysis.

Gibson, Lorelei S.↗

Air Circulation and Heat Exchange Under Reduced Pressures

Heat exchange rates decrease non-linearly with reductions in atmospheric pressure. This decrease creates risk of thermal stress (elevated leaf temperatures) for plants under reduced pressures. Forced convection (fans) significantly increases heat exchange rate under almost all pressures except below ~ 10 kPa. Plant cultivation techniques under reduced pressures will require forced convection. The cooling curve technique is a reliable means of assessing the influence of environmental variables like pressure and gravity on gas exchange of plant. These results represent the extremes of gas exchange conditions for simple systems under variable pressures. In reality, dense plant canopies will exhibit responses in between these extremes. More research is needed to understand the dependence of forced convection on atmospheric pressure. The overall thermal balance model should include latent and radiative exchange components.

Rygalov, V.↗

Fracture mechanics technology for optimum pressure vessel design.

A technique has been developed to design a maximum efficiency reliable pressure vessel of given geometry and service life. The technique for ensuring reliability of the minimum weight vessel relies on the application of linear elastic fracture mechanics and fracture mechanics concepts. The resultant design incorporates potential fatigue and stress corrosion crack extension during service of a worst case initial flaw. Maximum stress for safe life is specified by the design technique, thereby minimizing weight. Ratios of pressure and toughness parameters are employed to avoid arbitrary specification of design stress level which would lead to a suboptimum design.

Bjeletich, J. G.↗

TankSIM: A Cryogenic Tank Performance Prediction Program

Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.

Bolshinskiy, L. G.↗

Method development for compensating temperature effects in pressure sensitive paint measurements

Pressure sensitive luminescent paints (PSP) have recently emerged as a viable technique for aerodynamic pressure measurements. The technique uses a surface coating which contains probe molecules that luminesce when excited by light of an appropriate wavelength. The photoluminescence of these materials is known to be quenched by the presence of molecular oxygen. Since oxygen is a fixed mole fraction of the air, the coating's luminescence intensity varies inversely with air pressure. Digital imaging of the luminescence varying across a coated surface produces a pressure distribution map over that surface. One difficulty encountered with this technique is the temperature effect on the luminescence intensity. Present PSP formulations have significant sensitivity to temperature. At the moment, the most practical way of correcting for temperature effects is to calibrate the paint in place at the operating temperatures by using a few well-placed pressure taps. This study is looking at development of temperature indicating coatings that can be applied and measured concurrently with PSP, and use the temperature measurement to compute the correct pressure. Two methods for this dual paint formulation are proposed. One method will use a coating that consists of temperature sensitive phosphors in a polymer matrix. This is similar in construction to PSP, except that the probe molecules used are selected primarily for their temperature sensitivity. Both organic phosphors (e.g., europium thenoyltrifluoroacetonate, bioprobes) and inorganic phosphors (e.g., Mg4(F)GeO6:Mn, La2O2S:Eu, Radelin Type phosphors, Sylvania Type phosphors) will be evaluated for their temperature sensing potential. The next method will involve a novel coating composing of five membered heterocyclic conducting polymers which are known to show temperature dependent luminescence (e.g., poly(3-alkylthiopene), poly(3-alkylselenophene), poly(3-alkylfuran)). Both methods will involve applying a bottom layer of temperature sensitive coating followed by a top coating of PSP. An oxygen-impermeable polymer can be used as the temperature sensitive coating matrix, or it can be layered in between the coatings to prevent oxygen quenching of the bottom coating's luminescence. The probe molecules of the coatings will be excited by a broad band of light, with the different emissions detected and measured at their distinct wavelengths. Developmental research of these coatings is still in progress; however, preliminary results look very promising.

Demandante, Carlo Greg N.↗

Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program

Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.

Bolshinskiy, L. G.↗

Design and Testing of a Blended Wing Body With Boundary Layer Ingestion Nacelles at High Reynolds Numbers

A knowledge-based aerodynamic design method coupled with an unstructured grid Navier-Stokes flow solver was used to improve the propulsion/airframe integration for a Blended Wing Body with boundary-layer ingestion nacelles. A new zonal design capability was used that significantly reduced the time required to achieve a successful design for each nacelle and the elevon between them. A wind tunnel model was built with interchangeable parts reflecting the baseline and redesigned configurations and tested in the National Transonic Facility (NTF). Most of the testing was done at the cruise design conditions (Mach number = 0.85, Reynolds number = 75 million). In general, the predicted improvements in forces and moments as well as the changes in wing pressures between the baseline and redesign were confirmed by the wind tunnel results. The effectiveness of elevons between the nacelles was also predicted surprisingly well considering the crudeness in the modeling of the control surfaces in the flow code. A novel flow visualization technique involving pressure sensitive paint in the cryogenic nitrogen environment used in high-Reynolds number testing in the NTF was also investigated.

Campbell, Richard L.↗

Absorption cross section measurements of oxygen in the wavelength region 195-241 nm of the Herzberg continuum

The continuous absorption cross section of oxygen in the region 205-241 nm is studied as a function of path length and oxygen pressure. The technique used to study the continuous absorption cross section is described. Cross section measurements of oxygen in the wavelength region 193-205 nm obtained by Cheung et al. (1984) are applied in this experiment. The measured cross section is analyzed in terms of a Herzberg continuum and a pressure-dependent continuum. The total measured continuum cross section, the cross section involving two molecules of O2, and the Herzberg continuum absorption cross section values are calculated. It is observed that the Herzberg continuum cross section of oxygen values measured at 1 nm intervals in the region 195-241 nm, increase from 6.3 x 10 to the -24th sq cm at 195 nm to a maximum of 6.6 x 10 to the -24th sq cm at 201 nm and then decrease to 0.85 x 10 to the -24th sq cm at 241 nm. The Herzberg values are compared with data from previous investigations and the values correlate well.

Cheung, A. S.-C.↗

Multicolor laser altimeter for barometric measurements over the ocean - Theoretical

It is noted that the optical path length from a satellite to the earth's surface strongly depends on the atmospheric pressure along the propagation path. The theoretical basis of a surface pressure measurement technique, which uses a two-color laser altimeter to observe the change with wavelength in the optical path length from a satellite to the ocean surface, is evaluated. The statistical characteristics of the ocean-reflected pulses and the expected measurement accuracy are analyzed in terms of the altitude parameters. The results show that it is feasible to obtain a pressure accuracy of a few millibars.

Gardner, C. S.↗

Application of polyimide actuator rod seals

Development of polyimide two-stage hydraulic actuator rod seals for application in high-performance aircraft was accomplished. The significant portion of the effort was concentrated on optimization of the chevron and K-section second-stage seal geometries to satisfy the requirements for operation at 450 K (350 F) with dynamic pressure loads varying between 200 psig steady-state and 1500 psig impulse cycling. Particular significance was placed on reducing seal gland dimension by efficiently utilizing the fatigue allowables of polyimide materials. Other objectives included investigation of pressure balancing techniques for first-stage polyimide rod seals for 4000 psig 450 K(350 F) environment and fabrication of a modular retainer for the two-stage combination. Seals were fabricated in 0.0254 m (1.0in.) and 0.0635 m (2.5in.) sizes and tested for structural integrity, frictional resistance, and endurance life. Test results showed that carefully designed second stages using polyimides could be made to satisfy the dynamic return pressure requirements of applications in high-performance aircraft. High wear under full system pressure indicated that further research is necessary to obtain an acceptable first-stage design. The modular retainer was successfully tested and showed potential for new actuator applications.

Watermann, A. W.↗

Measuring Leakage in a Pressurized-Fluid Loop

Technique applied to systems with inaccessible parts and connections. Fluid added to system by fluid-injection assembly to make up for leakage. Amount required to restore pressure in system is measure of leakage rate.

Clarke, Brian D.↗