Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-Pressure Transducer Package

Enclosure for silicon device ensures accurate measurements of cryogenic liquids. Package holds silicon sensor in uniform compression around periphery and helps ensure accurate, stable, and repeatable pressure measurements. Mounting assembly housed in package of stainless steel. Materials selected for equality of thermal expansion and for pressure-sealing properties. Besides its high-pressure, low-temperature characteristics, package withstands vibrations as severe as 400 times standard gravitational acceleration at 0 to 2,000 Hz.

Wamstad, D.↗

Shock tube investigation of dynamic response of pressure transducers for validation of rotor performance measurements

For some time now, NASA has had a program under way to aid in the validation of rotor performance and acoustics codes associated with the UH-60 rotary-wing aircraft; and to correlate results of such studies with those obtained from investigations of other selected aircraft rotor performance. A central feature of these studies concerns the dynamic measurement of surface pressure at various locations up to frequencies of 25 KHz. For this purpose, fast-response gauges of the Kulite type are employed. The latter need to be buried in the rotor; they record surface pressures which are transmitted by a pipette connected to the gauge. The other end of the pipette is cut flush with the surface. In certain locations, the pipette configuration includes a rather sharp right-angle bend. The natural question has arisen in this connection: In what way are the pipettes modifying the signals received at the rotor surface and subsequently transmitted to the sensitive Kulite transducer element. The basic details and results of the program performed and recently completed in the High Pressure Shock Tube Laboratory of the Department of Aeronautics and Astronautics at Stanford University are given.

Bershader, Daniel↗

Pressure transducer with four-decade dynamic range

Adjustable resistor taps in gain-control feedback loop of the transducer permit wide sensing range, shorting the pins on electrical connector allows selection of appropriate range. Electrical specifications of the transducer and its applications are cited.

Source record↗

Absolute pressure transducers for space shuttle and orbiter propulsion and control systems

A preliminary design was completed, reviewing of such subjects as: the trade studies for media isolation and one sensor vs. two sensors for two bridges; compensation resistors; unit design; hydrogen embrittlement; sealing techniques and test station design. A design substantiation phase was finished, consisting of testing of a prototype unit and fabrication technique studies. A cryogenic test station was implemented and prototype sensor cells were fabricated, sensors assembled, and cryogenic tests performed.

Bolta, J. J.↗

A high-temperature wideband pressure transducer

The problem of operating a condenser microphone as a terminal element of a half wavelength transmission line was dealt with; the environment in which the microphone operates necessitates a 25 foot separation from its supporting electronics. A theoretical analysis of the microphone-cable system, substantiated by laboratory tests, provided criteria to optimize system gain.

Zuckerwar, A. J.↗

Trielectrode capacitive pressure transducer

A capacitive transducer and circuit especially suited for making measurements in a high-temperature environment are described. The transducer includes two capacitive electrodes and a shield electrode. As the temperature of the transducer rises, the resistance of the insulation between the capacitive electrode decreases and a resistive current attempts to interfere with the capacitive current between the capacitive electrodes. The shield electrode and the circuit coupled there reduce the resistive current in the transducer. A bridge-type circuit coupled to the transducer ignores the resistive current and measures only the capacitive current flowing between the capacitive electrodes.

Coon, G. W.↗

Ceramic-to-metal bonding for pressure transducers

A solid-state diffusion technique involving the placement of a gold foil between INCONEL X-750 and a machinable glass-ceramic "MACOR" was shown to be successful in bonding these two materials. This technique was selected after an exhaustive literature search on ceramic-metal bonding methods. Small expansion mismatch between the Inconel and the MACOR resulted in fracture of the MACOR when the bonded body was subjected to tensile stress of 535 psi. The bonded parts were submitted to a cyclic loading test in an air atmosphere at 1 Hz from 0 to 60 KPa. Failure was observed after 700,000 cycles at 650 C. Ceramic-Inconel bonding was not achieved with this method for boron nitride and silica glass.

Mackenzie, J. D.↗

Current Pressure Transducer Application of Model-based Prognostics Using Steady State Conditions

Prognostics is the process of predicting a system's future states, health degradation/wear, and remaining useful life (RUL). This information plays an important role in preventing failure, reducing downtime, scheduling maintenance, and improving system utility. Prognostics relies heavily on wear estimation. In some components, the sensors used to estimate wear may not be fast enough to capture brief transient states that are indicative of wear. For this reason it is beneficial to be capable of detecting and estimating the extent of component wear using steady-state measurements. This paper details a method for estimating component wear using steady-state measurements, describes how this is used to predict future states, and presents a case study of a current/pressure (I/P) Transducer. I/P Transducer nominal and off-nominal behaviors are characterized using a physics-based model, and validated against expected and observed component behavior. This model is used to map observed steady-state responses to corresponding fault parameter values in the form of a lookup table. This method was chosen because of its fast, efficient nature, and its ability to be applied to both linear and non-linear systems. Using measurements of the steady state output, and the lookup table, wear is estimated. A regression is used to estimate the wear propagation parameter and characterize the damage progression function, which are used to predict future states and the remaining useful life of the system.

Fault Estimation↗

A dynamic pressure calibration standard

A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Schutte, P. C.↗

Subminiature transducer measures unsteady pressures

Transducer has thin piezoelectric sensing element of 0.051-cm-thick lead zirconate titanate crystal which is cut as a conical frustum. Sensing crystal and titanium wire are protected from mechanical shock and vibration. Transducer is insensitive to mechanical vibrations of instrument plug on which it is mounted.

Raman, K. R.↗

Evaluation of an electronic scanner of pressure (ESOP) module

An electronic scanner of pressure (ESOP) module, developed by NASA Ames Research Center, was installed in a wind tunnel and evaluated over a 5-month testing period. The solid-state ESOP module has 48 miniature pressure transducers and a heater circuit to maintain a constant module temperature. During the wind tunnel test, the module was subjected to an environmental temperature range from 60 F to 104 F, and to considerable module vibration. Zero drift was within + or - 0.5 percent of full-scale output for 37 of the transducers, and was greater than 5.0 percent for four transducers. Pressure measurements from 12 transducers were compared with Scanivalve modules. The agreement of these measurements was considered to be good.

Smeltzer, D. B.↗