Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗

Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

60 APPLIED LIFE SCIENCES↗

A method for monitoring deposition at a solid cathode in an electro-refiner for a two-species system using electrode potentials

Currently, process monitoring of spent nuclear fuel electrorefining relies upon sampling and destructive analysis methods coupled with extrapolated thermodynamic process models for non-interrupted operations. An 'inverse' model was developed to predict the product deposition rates on a cathode using the cell current, cathode potential, and fundamental relations of electrochemistry. The model was applied to the following cases: pure uranium deposition, co-deposition of uranium and plutonium, and co-deposition of uranium and zirconium. The deposition rates predicted by this 'inverse' model were compared to those of a 'forward' model, ERAD. On average, the predicted deposition rates had relative errors of 3.88 % and 2.84 % for U and Pu, respectively, in the case of U/Pu co-deposition and 4.16 % and 7.44 % for U and Zr, respectively, in the case of U/Zr co-deposition. Thus, the 'inverse' model was able to predict the deposition rates without requiring information regarding the feed and salt composition, as the forward model, ERAD, does.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Analysis of Volatile Organic Compounds in a Controlled Environment: Ethylene Gas Measurement Studies on Radish

Volatile organic compound(VOC), ethylene gas, was characterized and quantified by GC/FID. 20-50 ppb levels were detected during the growth stages of radish. SPME could be a good analytical tool for the purpose. Low temperature trapping method using dry ice/diethyl ether and liquid nitrogen bath was recommended for the sampling process for GC/PID and GC/MS analysis.

Kong, Suk Bin↗

Lunar sample analysis

The surface composition of lunar fines, the solar wind sputtering process, and the profile of reduced Fe in lunar samples are reported. Atomic absorption studies of trace metal, especially lead, distribution in lunar fines samples are described.

Housley, R. M.↗

A Method for Monitoring Deposition at a Solid Cathode in an Electrorefiner for a Two-Species System Using Electrode Potentials

Currently, process monitoring of spent nuclear fuel electrorefining relies upon sampling and destructive analysis methods coupled with extrapolative thermodynamic process models for non-interrupted operations. Corrections to those models are performed infrequently, jeopardizing both the control of the process and safeguarding of nuclear material. Furthermore, the timeliness of obtaining the results is inadequate for application of international safeguards protocol. Alternatively, a system that dynamically utilizes electrical data such as electrode potentials and cell current can hypothetically be used to achieve real-time process monitoring and more robust control as well as improved safeguards. Efforts to develop an advanced model of the electrorefiner to date have focused on a forward modeling approach by using feed and salt compositions to determine the product composition, cell current and electrode potential response. Alternatively, an inverse model was developed, and reported here, to predict the product deposition rates on a cathode using the cell current, cathode potential, and fundamental relations of electrochemistry. The model was applied to the following cases: pure uranium deposition, co-deposition of uranium and plutonium, and co-deposition of uranium and zirconium. The deposition rates predicted by the inverse model were compared to those of a forward model, ERAD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Signatures of Fuel Irradiation in Large Particle Samples

Understanding the operating history of a nuclear facility is one of the key goals in nuclear safeguards, enabling the verification of declared activities. This is accomplished via a number of mechanisms, including the analysis of samples collected at the facility. The best metrics for understanding and verifying the history of nuclear fuel are (1) actinide isotopic content and (2) actinide inter-element ratios. While techniques have long existed for measuring these values with high accuracy and precision in bulk samples, as samples become smaller – such as may be collected in environmental collection – new methods are required both for clean processing of pure samples, and for analysis of these small samples. This study describes a new extraction chromatography technique for recovering U, Pu, and Am from single small aliquots, and advanced mass spectrometry methods for high-precision and high-accuracy analysis of trace and ultra-trace levels of actinides. These techniques are applied to particle samples cut from fuel from a historic nuclear reactor. Ages calculated from Pu–Am chronometry of particles are in excellent agreement with the known operating history of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A data analysis method to rapidly characterize gallium concentration in plutonium matrices using LIBS

The processing of actinide samples is a complex and costly endeavor that requires compositional analysis at various stages. Laser-induced breakdown spectroscopy (LIBS) has been used to analyze actinide-containing samples in many nuclear applications including waste management, fuel processing and forensics. The LIBS spectrum obtained from actinide materials are generally extremely complex, exhibiting many thousands of strong emission lines. This makes it difficult to identify other elements within the sample of interest, given the rich and dominant actinide spectrum. Here, in this article, we describe a recent effort to identify and quantify impurities and alloying constituents in plutonium matrices using a hand-held LIBS instrument that is used to rapidly and efficiently measure an emission spectrum from a material sample. We tabulate the emission line positions and intensities of plutonium. We report the development of machine-learning software that can identify gallium and quantify its concentration in plutonium matrices. This work has the potential to provide a rapid and nearly non-destructive technique that allows more confidence in characterizing the composition of materials that are present within complex actinide associated targets. We describe how our LIBS measurements and data analysis methods have successfully quantified the gallium concentration in a variety of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanodroplet processing platform for deep and quantitative proteome profiling of 10–100 mammalian cells

Nanoscale or single cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here, we report the development of a nanoPOTS (Nanodroplet Processing in One pot for Trace Samples) platform as a major advance in overall sensitivity. NanoPOTS dramatically enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive LC-MS, nanoPOTS allows identification of ~1500 to ~3,000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Between Runs algorithm of MaxQuant, >3000 proteins were consistently identified from as few as 10 cells. Furthermore, we demonstrate robust quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.

Environmental Molecular Sciences Laboratory↗

Framework for custom event sample augmentations for ATLAS analysis data

For HEP event processing, data is typically stored in column-wise synchronized containers, such as most prominently ROOT’s TTree, which have been used for several decades to store by now over 1 exabyte. These containers can combine row-wise association capabilities needed by most HEP event processing frameworks (e.g. Athena for ATLAS) with column-wise storage, which typically results in better compression and more efficient support for many analysis use-cases. One disadvantage is that these containers, TTree in the HEP use-case, require to contain the same attributes for each entry/row (representing events), which can make extending the list of attributes very costly in storage, even if those are only required for a small subsample of events. Since the initial design, the ATLAS software framework features powerful navigational infrastructure to allow storing custom data extensions for subsamples of events in separate, but synchronized containers. This allows adding event augmentations to ATLAS standard data products (such as DAOD-PHYS or PHYSLITE) avoiding duplication of those core data products, while limiting their size increase. For this functionality, the framework does not rely on any associations made by the I/O technology (i.e. ROOT), however it supports TTree friends and builds the associated index to allow for analysis outside of the ATLAS framework. A prototype based on the Long-Lived Particle search is implemented and preliminary results with this prototype will be presented. At this point, augmented data are stored within the same file as the core data. Storing them in separate files will be investigated in future, as this could provide more flexibility, e.g. certain sites may only want a subset of several augmentations or augmentations can be archived to tape once their analysis is complete.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A technique to correct for sample thickness variations for use with IDAPS X-ray radiograph analysis

The Image Data Processing System (IDAPS) at the Marshall Space Flight Center is used to analyze radiographs of metal samples to qualitatively and quantitatively map compositional variations across the samples. When the X-ray radiographs are of samples having thickness variations, corrections must be made to accomplish compositional analysis. A correction technique is described for cylindrical samples and is applied to radiographs of SPAR Experiment 74-18. Uncorrected and corrected images are shown.

Schafer, C. F.↗

An Examination of Issues Related to a Europa Subsurface Component for the JIMO Mission

The Galileo Europa data set served to revolutionize our view of Europa. In particular the strong evidence of a large, cold, salty Ocean beneath 5-30 km of ice has profoundly altered the significance of Europa in our thinking, especially of context of habitability in the solar system. While much remains to be learned from spacecraft observations of several sorts, there are significant questions answerable only by in-situ techniques; these relate to the formation of Europa, the nature of its ocean, and the prospects for life in its ocean, sediments, and ice. We feel that wide-ranging discussion of an in-situ subsurface mission to Europa, as part of JIMO, should proceed. The science objective of the mission is to characterize the icy shell of Europa to resolve its provenance, estimate the composition of brine of the Europa ocean, and search for evidence of Earth-like life. Probably anyone would agree that an in-situ mission to Europa would be of great value, but he or she would also immediately take the position that such a mission is utterly impractical. We take the position here of defining the least complex mission that can nonetheless justify its cost and to argue that such a mission is realistic enough that it should be seriously considered. Our mission thinking has been: 1) Soft landing. A soft lander is required on a site sufficiently flat to offer a stable platform; no further site selectivity is required. 2) Subsurface exploration. The Europa subsurface must be examined. Surficial processes on Europa arguably have exposed the upper 200 m of shell to chemical effects from the Jovian radiation belts as well as cometary infall, etc; to examine native ice we must descend below that point to, for discussion, 300 m. At that depth we argue that the ice is characteristic of ice at depth and possibly is effectively sea ice. 3) Science data. A few simple measurements at various depths and at 300 m constitute a scientifically successful mission. Measurements would include analysis of meltwater for a few inorganic ions and amino acids and an optical examination of the borehole wall. 4) Communication. Transmission of data to an orbiter is essential, but we will constrain the landed mission to a daily communication over a few days. 5) Subsurface access. Drilling to 300 m is a significant challenge; it can be addressed by several means: Thermal Probe (Cryobot) which permits water to refreeze above the vehicle. This is our tentative choice with plutonium as the fuel to generate thermal energy for drilling and electrical power for operations. Open Hole Drill, a thermal system in which the meltwater is removed for greater thermal efficiency. Meltwater removal on Europa is both a complexity and a risk, but analysis is improved. Mechanical Drilling in which cutting or grinding generates ice chips which are removed. This is too complex at Europa temperatures. The measurement objectives for the mission will be: Obj. 1: Determine the concentration of simple inorganic salts in the Europa Ice Shell and, by extrapolation, of the ocean. These data will also validate spaceborne sensors. Obj. 2: Determine the nature and abundance of amino acids in the ice such that cometary infall material in the upper ice can be compared to material at depth. Obj. 3: Optically examine the ice to resolve inclusion structure, particulate content, and stratification. Access to 300 m depth is a significant if not audacious plan; we are aware that this has not been done on any planetary body. Our approach is the use of a plutonium heat source; to overcome Europa's surface temperature and to melt ice a significant amount of plutonium is needed, and significant shielding and other protective steps will be required. The quantity of plutonium is a key concern. The mission will require subsurface collection and processing of samples for in situ analysis, calling for a miniature, high pressure micro-sampling system designed to meet needs of instruments that require low presses for operation. The inlet system itself collects a micro-sample in the external high pressure environment, then transfers it into a protected low pressure environment for analysis.

Carsey, F. D.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Real Time, In-line Monitoring of Hanford Tank Wastes - Year 1 Report

The team comprised of students, postdocs, early, mid and senior career scientists from Los Alamos National Laboratory, Savanah River National Laboratory, Georgia Tech and Florida International University, with the guidance of H2C, is developing a suite of in-line instruments for the Hanford high level waste (HLW) and low active waste (LAW) processes to provide near-real-time analysis of waste form physical properties and composition. The work builds on results from the recent DOE-ORP, EM Technology Development and other projects that demonstrated promise for the use of real-time in-line monitoring (RTIM) to measure chemical compositions of slurries of up to 20 weight % solids. The goal is for this instrument suite is to substantially reduce the need for sampling for process control. Sample waste, exposure associated with sample analysis, and the demand for an external laboratory facility would be greatly reduced. The throughput of waste treatment systems would be improved by elimination of the downtime caused by waiting for sample results. This translates into reduced process storage as process knowledge will be continuously updated in near-real-time. These breakthrough technologies would significantly reduce the life cycle cost and accelerate the schedule for the Hanford tank waste mission.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of process steady state with autoregressive models and Bayesian inference

To improve efficiency, separations engineers will typically design process circuits containing recirculating streams, which mix one or more of the process outputs with the feed material. Doing so can improve efficiency, but will cause a delay in the system reaching steady state conditions until the recirculating load mass flows stabilize. In testing separation circuits, engineers will often test a variety of factors and complete an analysis from sample results. Knowledge of if a process is at steady state, as well as the steady state conditions of a process, is essential for a valid techno-economic analysis. However, the definition of process steady state is often poorly defined, or does not include uncertainty quantification. If the performance of a process operating under two different sets of conditions are compared, an engineer who does not test for steady state or quantify steady state conditions risks producing a faulty analysis. In this work, a Bayesian statistical method for testing if all streams are at steady state is further motivated and then derived. Then after testing for steady state, the same model is used with a prior distribution that enforces a steady state assumption to estimate steady state conditions. Further, these methods were validated in a solvent extraction pilot plant where steady state conditions for all outflows were inferred with uncertainty quantification. Analysis is completed with functions available to the reader as part of the BayesMassBal (V 1.1.0) software package written in R.

01 COAL, LIGNITE, AND PEAT↗