Detection of keyhole pore formations in laser powder-bed fusion using acoustic process monitoring measurements
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Systematic fault detection and control during laser powder bed fusion (L-PBF) has been a long-standing objective for system manufacturers and researchers in the additive manufacturing (AM) industry. This manuscript investigates a data fusion approach for detection of keyhole porosity formation during laser irradiation of Ti-6Al-4V substrates by concurrent recording of thermally induced optical emission measured using both off-axis and coaxial photodiode sensors, and acoustic emission. Subsurface defect formation was monitored via high-speed synchrotron X-ray imaging at 20,000 frames per second, enabling temporal registration of keyhole pore formation events to the monitoring signals at a resolution of 50 µs. We developed data fusion machine learning (ML) models for localized prediction of keyhole pore formation at various time scales ranging from 0.5 ms to 2 ms. The signal segments were featurized using two independent approaches: (1) power spectral density (PSD) and (2) highly comparative time series analysis (HCTSA) framework. The extracted features from different sensor modalities were fused together to construct a multimodal feature space and sequential feature selection was used to determine the most informative features for training the ML models. The predictive performance was evaluated for three classifying algorithms: Support Vector Machine (SVM), K-Nearest Neighbor (KNN), and Gaussian Naive Bayes (GNB). As a result, pore formation events were predicted with up to 0.95 F1-score, 1.0 recall and 0.94 accuracy. The most heavily weighted features indicate that model performance is chiefly governed by the acoustic monitoring signal, with a secondary contribution from the optical emission sensors.
Not Available
Technologies that enable near real-time isotopic analysis of advanced molten salt reactor (MSR) fuels are critically needed to safeguard these reactors, increase their operational efficiency, and enable their widespread deployment with confidence. We present a systematic approach to developing near real-time dissolution and chemical isolation of U, Pu, and major fission products from highly radioactive chloride molten salt samples. Chemical yields greater than 95% were observed for both uranium and the lanthanides. Interference reduction enabled the detection and quantification of key diagnostic isotopes (including 112Ag, 147Nd, and 153Sm) that were previously undetectable in the original sample. The results from this initial scoping study lay the foundation for the development of future automated systems that can enable cost-efficient, near-real time chemical separation and analysis of extremely highly radioactive molten salt samples.
Explore the source record for details and available documents.
The Department of Environmental Quality (DEQ) issued Reuse Permit No. I-161-02 (hereafter permit) for the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) Complex Cold Waste Ponds (CWP) on November 20, 2014. Permit Section 3 compliance activity (CA), CA-161-02, requires the permittee to prepare and implement a Quality Assurance Project Plan (QAPP) within 6 months of permit issuance. This QAPP is prepared in accordance with CA-161-02 using a template provided by DEQ.
The Department of Environmental Quality (DEQ) issued Reuse Permit No. I-161-02 (hereafter permit) for the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) Complex Cold Waste Ponds (CWP) on November 20, 2014, with minor Modification 1 effective March 7, 2017. Permit Section 3 compliance activity (CA), CA-161-02, requires the permittee to prepare and implement a Quality Assurance Project Plan (QAPP) within 6 months of permit issuance. This QAPP is prepared in accordance with CA-161-02 using a template provided by DEQ.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Oak Ridge National Laboratory’s (ORNL) Manufacturing Demonstration Facility (MDF) worked with EOS Group to evaluate the current in-situ sensor capabilities of an EOS M290 Laser Powder Bed Fusion machine. The M290 was fitted with a 1 Mega-Pixel (MP) grayscale visible-light camera and a 5 MP temporally integrated (TI) near-infrared (NIR) camera. One print from stainless steel (SS) 316 and two from Inconel 625 (IN625) were performed where data including in-situ imaging and a machine log file were captured. These data were subsequently analyzed using a Dynamic Multi-Scale Segmentation Convolutional Neural Network (DMSCNN) trained on user defined classes and correlated to as-printed flaws, in the form of porosity, discovered in X-Ray Computed Tomography (XCT). In Phase I, two indications were detected in-situ and spatially correlated to stochastic lack-of-fusion flaws discovered using XCT. In Phase II, using these links from in-situ signatures to XCT flaw populations, a second neural network (NN) was trained to create a Voxelized Property Prediction Model (VPPM) to predict porosity percentages within the part using only features garnered from the in-situ data from two IN625 complex geometries. The VPPM was able to accurately predict porosity values for IN625 parts with an R 2 value of 0.764.
Oak Ridge National Laboratory’s (ORNL) Manufacturing Demonstration Facility (MDF) worked with EOS Group to evaluate the current in-situ sensor capabilities of an EOS M290 Laser Powder Bed Fusion machine. The M290 was fitted with a 1 Mega-Pixel (MP) grayscale visible-light camera and a 5 MP temporally integrated (TI) near-infrared (NIR) camera. One print from stainless steel (SS) 316 and two from Inconel 625 (IN625) were performed where data including in-situ imaging and a machine log file were captured. These data were subsequently analyzed using a Dynamic Multi-Scale Segmentation Convolutional Neural Network (DMSCNN) trained on user defined classes and correlated to as-printed flaws, in the form of porosity, discovered in X-Ray Computed Tomography (XCT). In Phase I, two indications were detected in-situ and spatially correlated to stochastic lack-of-fusion flaws discovered using XCT. In Phase II, using these links from in-situ signatures to XCT flaw populations, a second neural network (NN) was trained to create a Voxelized Property Prediction Model (VPPM) to predict porosity percentages within the part using only features garnered from the in-situ data from two IN625 complex geometries. The VPPM was able to accurately predict porosity values for IN625 parts with an R 2 value of 0.764.
Explore the source record for details and available documents.