Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton Exchange Membrane Fuel Cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Micro-Tubular Fuel Cells

Micro-tubular fuel cells that would operate at power levels on the order of hundreds of watts or less are under development as alternatives to batteries in numerous products - portable power tools, cellular telephones, laptop computers, portable television receivers, and small robotic vehicles, to name a few examples. Micro-tubular fuel cells exploit advances in the art of proton-exchange-membrane fuel cells. The main advantage of the micro-tubular fuel cells over the plate-and-frame fuel cells would be higher power densities: Whereas the mass and volume power densities of low-pressure hydrogen-and-oxygen-fuel plate-and-frame fuel cells designed to operate in the targeted power range are typically less than 0.1 W/g and 0.1 kW/L, micro-tubular fuel cells are expected to reach power densities much greater than 1 W/g and 1 kW/L. Because of their higher power densities, micro-tubular fuel cells would be better for powering portable equipment, and would be better suited to applications in which there are requirements for modularity to simplify maintenance or to facilitate scaling to higher power levels. The development of PEMFCs has conventionally focused on producing large stacks of cells that operate at typical power levels >5 kW. The usual approach taken to developing lower-power PEMFCs for applications like those listed above has been to simply shrink the basic plate-and-frame configuration to smaller dimensions. A conventional plate-and-frame fuel cell contains a membrane/electrode assembly in the form of a flat membrane with electrodes of the same active area bonded to both faces. In order to provide reactants to both electrodes, bipolar plates that contain flow passages are placed on both electrodes. The mass and volume overhead of the bipolar plates amounts to about 75 percent of the total mass and volume of a fuel-cell stack. Removing these bipolar plates in the micro-tubular fuel cell significantly increases the power density.

Kimble, Michael C.↗

Durability of Membrane Electrode Assemblies (MEAs) in PEM Fuel Cells Operated on Pure Hydrogen and Oxygen

Proton exchange membrane (PEM) fuel cells are energy sources that have the potential to replace alkaline fuel cells for space programs. Broad power ranges, high peak-to-nominal power capabilities, low maintenance costs, and the promise of increased life are the major advantages of PEM technology in comparison to alkaline technology. The probability of PEM fuel cells replacing alkaline fuel cells for space applications will increase if the promise of increased life is verified by achieving a minimum of 10,000 hours of operating life. Durability plays an important role in the process of evaluation and selection of MEAs for Teledyne s Phase I contract with the NASA Glenn Research Center entitled Proton Exchange Membrane Fuel cell (PEMFC) Power Plant Technology Development for 2nd Generation Reusable Launch Vehicles (RLVs). For this contract, MEAs that are typically used for H2/air operation were selected as potential candidates for H2/O2 PEM fuel cells because their catalysts have properties suitable for O2 operation. They were purchased from several well-established MEA manufacturers who are world leaders in the manufacturing of diverse products and have committed extensive resources in an attempt to develop and fully commercialize MEA technology. A total of twelve MEAs used in H2/air operation were initially identified from these manufacturers. Based on the manufacturers specifications, nine of these were selected for evaluation. Since 10,000 hours is almost equivalent to 14 months, it was not possible to perform continuous testing with each MEA selected during Phase I of the contract. Because of the lack of time, a screening test on each MEA was performed for 400 hours under accelerated test conditions. The major criterion for an MEA pass or fail of the screening test was the gas crossover rate. If the gas crossover rate was higher than the membrane intrinsic permeability after 400 hours of testing, it was considered that the MEA had failed the test. Three types of MEAs out of the nine total membranes failed the test. The evaluation results showed that fuel cell operating conditions (current, pressure, stoichiometric flow rates) were the parameters that influenced the durability of MEAs. In addition, the durability test results indicated that the type of membrane was also an important parameter for MEA durability. At accelerated test conditions, the MEAs with casted membranes failed during the 400 hour test. However, the MEAs prepared from the casted membrane with support as well as extruded membranes, both passed the 400h durability test at accelerated operating test conditions. As a result of the MEA accelerated durability tests, four MEAs were selected for further endurance testing. These tests are being carried out with four-cell stacks under nominal fuel cell operating conditions.

Stanic, Vesna↗

Electrocatalysis in Alkaline Media and Alkaline Membrane-Based Energy Technologies

Hydrogen energy-based electrochemical energy conversion technologies offer the promise of enabling a transition of the global energy landscape from fossil fuels to renewable energy. Here, we present a comprehensive review of the fundamentals of electrocatalysis in alkaline media and applications in alkaline-based energy technologies, particularly alkaline fuel cells and water electrolyzers. Anion exchange (alkaline) membrane fuel cells (AEMFCs) enable the use of nonprecious electrocatalysts for the sluggish oxygen reduction reaction (ORR), relative to proton exchange membrane fuel cells (PEMFCs), which require Pt-based electrocatalysts. However, the hydrogen oxidation reaction (HOR) kinetics is significantly slower in alkaline media than in acidic media. Understanding these phenomena requires applying theoretical and experimental methods to unravel molecular-level thermodynamics and kinetics of hydrogen and oxygen electrocatalysis and, particularly, the proton-coupled electron transfer (PCET) process that takes place in a proton-deficient alkaline media. Extensive electrochemical and spectroscopic studies, on single-crystal Pt and metal oxides, have contributed to the development of activity descriptors, as well as the identification of the nature of active sites, and the rate-determining steps of the HOR and ORR. Among these, the structure and reactivity of interfacial water serve as key potential and pH-dependent kinetic factors that are helping elucidate the origins of the HOR and ORR activity differences in acids and bases. Additionally, deliberately modulating and controlling catalyst-support interactions have provided valuable insights for enhancing catalyst accessibility and durability during operation. The design and synthesis of highly conductive and durable alkaline membranes/ionomers have enabled AEMFCs to reach initial performance metrics equal to or higher than those of PEMFCs. We emphasize the importance of using membrane electrode assemblies (MEAs) to integrate the often separately pursued/optimized electrocatalyst/support and membranes/ionomer components. Operando/in situ methods, at multiscales, and ab initio simulations provide a mechanistic understanding of electron, ion, and mass transport at catalyst/ionomer/membrane interfaces and the necessary guidance to achieve fuel cell operation in air over thousands of hours. We hope that this Review will serve as a roadmap for advancing the scientific understanding of the fundamental factors governing electrochemical energy conversion in alkaline media with the ultimate goal of achieving ultralow Pt or precious-metal-free high-performance and durable alkaline fuel cells and related technologies.

30 DIRECT ENERGY CONVERSION↗

Computationally Assisted Design of Ion-conducting Polymers for Anion Exchange Membrane Fuel Cells (2nd Year Report) [Slides]

Phosphonated polymers have been proposed as proton conductors for fuel cells; however, the anhydride formation of phosphonic acid functional groups lowers proton conductivity and hinders their use in fuel cell applications. We used calculations to support this hypothesis by correlating calculated Gibbs free energies for the formation of the anhydride with pK values of the corresponding acid. The results showed that stronger acids are less likely to form an anhydride even at elevated temperatures and supported the design of a new polymer and the high-temperature proton exchange membrane fuel cell (HT-PEMFC) that outperformed other state-of-the-art HT-PEMFCs.

30 DIRECT ENERGY CONVERSION↗

Natural fiber-derived gas diffusion layers for high performance, lower cost PEM fuel cells

The gas diffusion layer (GDL) is a critical component of proton exchange membrane fuel cells. GDL manufacture is dominated by the use of polyacrylonitrile (PAN) fibers, resulting in high production costs. Those costs contribute to the high cost of fuel cell stacks. Thus, reducing GDL manufacturing costs without sacrificing performance, should help reduce the overall cost of the fuel cell stack. Using inexpensive, natural fiber-based papers and fabric as substrates, here we examine the inherent performance these materials as GDLs, and the improvements enabled by the addition of a microporous layer, gas-phase hydrophobic treatment, and densification. The resulting GDLs achieve equivalent performance the commercial baseline GDL and demonstrate the potential of lower cost GDLs.

25 ENERGY STORAGE↗

Influence of Water Transport Across Microscale Bipolar Interfaces on the Performance of Direct Borohydride Fuel Cells

Direct borohydride fuel cells (DBFCs) can operate at double the voltage of proton exchange membrane fuel cells (PEMFCs) by employing an alkaline NaBH 4 fuel feed and an acidic H 2 O 2 oxidant feed. The pH-gradient-enabled microscale bipolar interface (PMBI) facilitates the creation and maintenance of an alkaline environment at the anode and an acidic environment at the cathode for the borohydride oxidation and peroxide reduction reactions. However, given the need to dissociate water at the interface to ensure ionic conduction, PMBI can be efficient only when anion exchange ionomer (AEI) moieties enable fast water transport for autoprotolysis. Herein, a series of polynorbornene-based AEIs with a range of water uptake values are examined to unravel the optimum water uptake required to enable high performance DBFCs. The DBFC with PMBI configuration containing the optimal AEI composition delivers a current density of 302 mA cm –2 at 1.5 V and a peak power density of 580 mW cm –2 at 1 V. This AEI composition exhibits high hydroxide ionic conductivity of 90.7 mS cm –1 at 80 °C with an IEC of 2.01 mequiv g –1 and demonstrates impressive chemical stability by retaining 98.75% of its initial ionic conductivity after immersion into anolyte (3 M KOH and 1.5 M NaBH 4 ) at 70 °C for 536 h.

25 ENERGY STORAGE↗

Surface Decoration of Platinum Catalysts by ZrO 2– x Nanoclusters for Durable Fuel Cell Applications

Improving the activity and durability of carbon-supported platinum catalysts for the oxygen-reduction reaction (ORR) in acidic electrolytes is crucial to reducing the high overpotentials and power loss over time in proton-exchange membrane fuel cells (PEMFCs). We found that platinum nanoparticle catalyst deposited on an engineered carbon support in the presence of zirconium enabled higher ORR activity and 25% better retention in electrochemically active surface area (ECSA), thereby improving durability. The use of zirconium precursor in the carbon synthesis process led to the formation of atomically dispersed Zr and ZrO 2 nanoparticles on the support. Upon Pt deposition and subsequent heat treatment, the ZrO 2 particles preferentially rearranged on and around the platinum nanoparticles in a chemically reduced form as zirconium suboxide (ZrO 2-x ) surface-decorated nanoclusters, which mitigated Pt nanoparticle coarsening. Finally, analysis of the here-to-fore unknown catalyst structure as well as its performance and durability in a PEM fuel cell membrane electrode assembly (MEA) is discussed.

25 ENERGY STORAGE↗

Machine learning for optimizing the manufacture and operation of intermediate temperature fuel cells

The project developed machine learning and artificial intelligence (ML/AI) methodologies for guiding and accelerating the materials design and processing of new high temperature proton conducing electrode ionomer binders and reinforced membranes for high-temperature proton exchange membrane fuel cell (HT-PEMFC; aka intermediate-temperature polymer electrolyte membrane fuel cells).

08 HYDROGEN↗

Highly durable fuel cell electrocatalyst with low-loading Pt-Co nanoparticles dispersed over single-atom Pt-Co-N-Graphene nanofiber

The limited durability of Pt electrocatalysis toward cathodic oxygen reduction reaction remains challenging, yet crucial for the development of Proton Exchange Membrane Fuel Cell. Here, we present a rational design of a robust catalyst consisting of PtCo nanoparticles supported on Pt-Co-N-graphene nanofiber prepared through electrospun Cobalt-Metal-Organic-Framework. The catalyst delivers unprecedented mass activity of 2.48 A·mgPt -1 , and retains 80% of initial value after 60,000 Accelerated-Stress-Test cycles. Operando X-ray absorption spectroscopies show that the electronic configurations of Pt sites in PtCo and Co sites in Co-N4 in the hybrid catalyst are modified toward high catalytic activities. Density Functional Theory unveils that the enhanced curvature of the substrate induced by the morphology engineering lowers the reaction thermodynamic barrier on Co-N4 sites, favoring the formation of H2O and suppressing that of H2O2. This result along with the strong affinity of PtCo nanoparticles to the Pt-Co-N-graphene fiber endows the catalyst an exceptional durability.

acidic electrolyte↗

High protonic resistance of hydrocarbon-based cathodes in PEM fuel cells under low humidity conditions: Origin, implication, and mitigation

Hydrocarbon-based electrodes for proton-exchange membrane fuel cells face challenges in closing the performance gap with electrodes based on perfluorosulfonic acid ionomers, particularly under low humidity conditions. Alongside increased oxygen transport resistance and higher kinetic-induced overpotentials, the protonic resistance of these fluorine-free electrodes is the primary hurdle to improved performance. This study systematically investigates the origin and impact of the cathode protonic resistance on fuel cell performance, utilizing sulfonated phenylated polyphenylenes as hydrocarbon ionomers. Electrochemical characterization at low relative humidity (≤50 %) reveal a high protonic resistance arising from both lower conductivity of the hydrocarbon thin film compared to the bulk membrane and increased cathode tortuosity at a gas transport-optimized ionomer to carbon (I/C) ratio of 0.2. The poor protonic resistance at low relative humidities leads to a non-homogeneous current distribution across the thickness of the cathode electrode, resulting in lower catalyst utilization. To address this issue, reducing the thickness of the cathode CL while maintaining a constant Pt loading (i.e., increasing the Pt on carbon ratio) significantly reduces protonic resistance. This improvement compensates for the kinetic disadvantages of highly loaded carbon particles and results in a considerable performance increase by 40 % at 0.75 V under low relative humidities.

25 ENERGY STORAGE↗

Design Trade-Offs in Composite Fuel Cell Membranes: Effects of Reinforcement and Chemical Additives

Perfluorosulfonic acid (PFSA) membranes are critical components in proton exchange membrane fuel cells, where performance depends on balancing ionic conductivity, mechanical durability, and chemical stability. This study characterizes a composite membrane (NC700) featuring PFSA-impregnated expanded polytetrafluoroethylene (ePTFE) reinforcement and cerium-based radical scavengers, benchmarked against unreinforced NR211. Complementary techniques, including electron microscopy, X-ray scattering, infrared spectroscopy, thermogravimetric analysis, and dynamic mechanical analysis, identify the structural and compositional strategies employed in NC700. Water sorption isotherms reveal lower water uptake for NC700 across all conditions, attributed to reinforcement and cerium incorporation. Reinforcement reduces in-plane swelling from 11% to 2.1% at 90% RH, confirming strong swelling anisotropy, while maintaining mechanical properties at elevated temperatures. While the ionic conductivity of NC700 is approximately 10% lower than that of NR211, the reduced thickness yields a 40% decrease in calculated area-specific resistance, suggesting the composite architecture can favorably shift the conductivity-stability trade-off. The composite structure also reduces gas permeability, indicating potential for improved separator function alongside favorable transport properties. Systematic deconvolution of reinforcement and additive contributions shows that conductivity losses from cerium incorporation are largely offset by gains from the lower equivalent-weight polymer, providing quantitative relationships that may guide composite membrane design for fuel cells and other electrochemical applications.

25 ENERGY STORAGE↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by the catalyst metal itself and its interactions with the carbon support. Several low-loaded PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. Overall, this is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration.

25 ENERGY STORAGE↗

Impact of Carbon Support Structure on the Durability of PtCo Electrocatalysts

High performing, low-Pt content fuel cell membrane electrode assemblies (MEAs) are critical to the economic viability of proton exchange membrane fuel cells (PEMFCs) for the transportation industry. Considerable research has been conducted to reduce the Pt content in fuel cells, leading to the development of transition metal alloys, such as Platinum-Cobalt (PtCo). The degree of degradation of PtCo catalysts can be impacted by not only the composition and morphology of the catalyst particle itself, but also its interactions with the carbon support. In this study several low-PtCo MEAs were fabricated, with various combinations of porous and solid carbon cathode catalyst supports. The MEAs were subjected to an accelerated stress test (AST), and the catalyst degradation characterized using electrochemical, X-ray scattering, and electron microscopy techniques. Porous supports retain more of their electrochemically-active surface area (ECSA) and demonstrate higher performance after the AST. This is believed to be due to the ability of the porous supports to trap the metal particles within the pores, slowing their dissolution/precipitation, and agglomeration. However porous supports also exhibit greater increases in transport resistance probably associated with enhanced Co leaching under the AST conditions.

25 ENERGY STORAGE↗

Coating developments towards enabling aluminum as a bipolar plate material for PEM fuel cells

Bipolar plates represent a significant portion of the cost and weight of a proton exchange membrane fuel cell stack. As a result, there has been significant interest in using low weight and cost materials, such as aluminum. Aluminum has good mechanical and physical properties; however, it performs poorly in the corrosive environment within the fuel cell stack. To overcome the corrosion performance issue, there have been efforts towards developing coating processes to enable aluminum to attain corrosion targets. In an effort to enable aluminum as a viable bipolar plate material, a solid phase processing (diffusion bonding) approach for bonding a titanium foil to aluminum is investigated in this study. The microstructure, corrosion performance, mechanical properties and electrical resistance are investigated. To avoid the known reduction in contact resistance performance of titanium after exposure to bipolar plate media, the effect of addition of highly conductive gold particles after diffusion bonding, on contact resistance and corrosion behavior, is also studied and compared with diffusion bonded Ti to Al. In conclusion, the results indicate that diffusion bonded Ti to Al provides a viable alternative material combination for bipolar plate that avoids the micro pores and crevasses that are associated with vapor deposition or electroplating.

25 ENERGY STORAGE↗

Operando carbon corrosion measurements in fuel cells using boron-doped carbon supports

Carbonaceous materials are the most common catalyst supports in proton exchange membrane fuel cell (PEMFCs), yet their corrosion is one of the limiting factors in achieving high durability. Herein, we doped carbon supports with boron (B) to increase the corrosion-resistance of the support. Two types of B-doped carbons were synthesized and studied as platinum support materials. Further, they varied in their morphologies, surface areas, and the types of boron species. The durability of Pt/B-doped carbon catalysts was investigated using the US-DOE catalysts’ supports accelerated stress test (AST) and a mass-spectrometer connected to the fuel cell effluent stream to quantify the mass of corroded carbon support in operando. The addition of boron to the carbon increased the stability of Pt catalysts in long-term usage of PEMFC. After 4000 AST cycles, more than 50% of initial current density was preserved for the boron-containing systems, while less than 30% of it remained with Vulcan carbon (Pt/V). Also, the Pt/B-doped carbon samples demonstrated better electrochemical active surface area (ECSA) stability when compared to Pt/V. Carbon loss measurements showed that B-doped carbons have higher resistance to electrochemical corrosion than unmodified carbon. Specifically, the substitutional boron-doped carbon demonstrated an extremely high stability and low corrosion rate.

25 ENERGY STORAGE↗

Impact of the Cathode Pt Loading on PEMFC Contamination by Several Airborne Contaminants

Proton exchange membrane fuel cells (PEMFCs) with 0.1 and 0.4 mg Pt cm -2 cathode catalyst loadings were separately contaminated with seven organic species: Acetonitrile, acetylene, bromomethane, iso-propanol, methyl methacrylate, naphthalene, and propene. The lower catalyst loading led to larger cell voltage losses at the steady state. Three closely related electrical equivalent circuits were used to fit impedance spectra obtained before, during, and after contamination, which revealed that the cell voltage loss was due to higher kinetic and mass transfer resistances. A significant correlation was not found between the steady-state cell voltage loss and the sum of the kinetic and mass transfer resistance changes. Major increases in research program costs and efforts would be required to find a predictive correlation, which suggests a focus on contamination prevention and recovery measures rather than contamination mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creating Favorable Pt/Co Interfaces via a Two‐Step Approach for Constructing Highly Durable PtCo Intermetallic Fuel Cell Catalysts

Structurally ordered PtCo intermetallics are one of the most promising oxygen-reduction catalysts in proton exchange membrane fuel cells (PEMFCs) due to their intrinsically improved catalytic activity and stability relative to PtCo solid-solution alloys. However, increasing the heating temperature to achieve a desirable high degree of ordering results in severe particle agglomeration and low mass activity and stability. Herein, a two-step synthesis approach is developed to create an L1 2 -Pt 3 Co intermetallic structure with an increased ordering degree and well-dispersed ultrafine particles. The first step of the synthesis yields ultrafine Pt nanoparticles that are well-dispersed on the ZIF-8-derived carbon support. The second adsorption step enables us to fine-tune the Pt and Co interfaces, assisted by optimal amino acids, to establish a favorable Co-rich environment around fine Pt nanoparticles, facilitating Co diffusion into the Pt crystalline under mild thermal conditions (<800 °C). In conclusion, this two-step ordered L1 2 -Pt 3 Co catalyst is systematically evaluated using membrane electrode assemblies under heavy-duty vehicle (HDV) conditions and demonstrated exceptional performance and durability, retaining 1.35 A cm -2 only a 7% loss in current density at 0.7 V after an extensive accelerated stress test of 150,000 voltage cycles.

30 DIRECT ENERGY CONVERSION↗