Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Direct measurement of electron beam quality conversion factors using water calorimetry

Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol. General agreement between the relative electron energy dependence of the PTW Roos data measured in this work and a recent MC-based study are also shown. Conclusions: This is the first time that water calorimetry has been successfully used to measure electron beam quality conversion factors for energies as low as 6 MeV (R{sub 50} = 2.25 cm)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microdosimetry and the radiation danger of cosmic rays

The radiation danger of space flights is due primarily to intensive proton fluxes accompanying solar flares and heavy multiple charged ions in galactic cosmic radiation. Evaluation of the biological effect of these kinds of rays is based on calculations of tissue dose, taking into account the formation of secondary radiation in shielding and tissue. The essential role in such calculations is played by the dependence of the factor of quality on linear energy transfer (LET) of these charged particles. Recommendations concerning the dependence of the quality factor on LET are based on radiobiological experiments carried out on many biological systems using various kinds of rays, including heavy ions with energies in the 1-10 Mev/nucleon range. Justification of the results of these experiments, as well as their extrapolation to other energies, requires development of a model description of the radiation effect of charged particles on biological microstructures.

Gunter, K.↗

Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose equivalent in radiotherapy environments simplifying the practical procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tailoring Surface Impurity Content to Maximize Q-factors of Superconducting Resonators

Quality factor of superconducting radio-frequency (SRF) cavities is degraded whenever magnetic flux is trapped in the cavity walls during the cooldown. In this contribution we study how the trapped flux sensitivity, defined as the trapped flux surface resistance normalized for the amount of flux trapped, depends on the mean free path. A variety of 1.3 GHz cavities with different surface treatments (EP, 120 C bake and different N-doping) were studied in order to cover the largest range of mean free path nowadays achievable, from few to thousands of nanometers. A bell shaped trend appears for the range of mean free path studied. Over doped cavities falls at the maximum of this curve defining the largest values of sensitivity. In addition, we have also studied the trend of the BCS surface resistance contribution as a function of mean free path, revealing that N-doped cavities follow close to the theoretical minimum of the BCS surface resistance as a function of the mean free path. Adding these results together we unveil that optimal N-doping treatment allows to maximize Q-factor at 2 K and 16 MV/m until the magnetic field fully trapped during the cavity cooldown stays below 10 mG.

43 PARTICLE ACCELERATORS↗

Engineering of Form Factor in Rotationally Symmetric Photonic Cavities for Faster Axion Searches

Form factor can be engineered in photonic cavities such that it dramatically increases the scan speed of axion haloscope detectors. Using higher-order modes of a photonic cavity, we can probe axions at larger mass ranges beyond the reach of current detectors that rely on conventional copper cavities. The main idea is to produce a higher-order mode with longitudinal field distribution that has relatively high amplitude away from both the cavity axis and the cavity walls such that it results in a relatively large form factor and maintains a high-quality factor. The detector scan speed significantly increases as it is proportional to the square of the form factor multiplied by the quality factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perturbation theory to model shielding effectiveness of cavities loaded with electromagnetic dampeners

It is notable that a slotted resonant cavity with high-quality factor exhibits interior electromagnetic (EM) fields that may be even larger than the external field. The authors aspire to reduce the cavity's EM fields and quality factor over a frequency band analytically, numerically, and experimentally by introducing microwave absorbing materials in the cavity. A perturbation model approach was developed to estimate the quality factor of loaded cavities, which is validated against full-wave simulations and experiments. Conclusions with 78.7 mils (2 mm) thick ECCOSORB-MCS absorber placed on the inside cavity wall above and below the aperture slot (with only 0.026% cavity volume) result in a reduction of shielding effectiveness >19 dB and reductions in quality factor >91%, providing confirmation of the efficacy of this approach.

42 ENGINEERING↗

SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function of the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.

60 APPLIED LIFE SCIENCES↗

Loss channels affecting lithium niobate phononic crystal resonators at cryogenic temperature

Here, we investigate the performance of microwave-frequency phononic crystal resonators fabricated on thin-film lithium niobate for integration with superconducting quantum circuits. For different design geometries at millikelvin temperatures, we achieve mechanical internal quality factors Qi above 10 5 –10 6 at high microwave drive power, corresponding to 5×10 6 phonons inside the resonator. By sweeping the defect size of resonators with identical mirror cell designs, we are able to indirectly observe signatures of the complete phononic bandgap via the resonators' internal quality factors. Examination of quality factors' temperature dependence shows how superconducting and two-level system (TLS) loss channels impact device performance. Finally, we observe an anomalous low-temperature frequency shift consistent with resonant TLS decay and find that the material choice can help to mitigate these losses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam loading compensation of traveling wave linacs through the time dependence of the rf drive

Beam loading in traveling-wave linear accelerating structures leads to unacceptable spread of particle energies across an extended train of bunched particles due to beam-induced field and dispersion. Methods for modulating the rf power driving linacs are effective at reducing energy spread, but for general linacs do not have a clear analytic foundation. We report here methods for calculating how to modulate the rf drive in arbitrarily nonuniform traveling-wave linacs within the convective-transport (power-diffusion) model that results in no additional energy spread due to beam loading (but not dispersion). Varying group velocity, loss factor, and cell quality factor within a structure, and nonzero particle velocity, are handled.

43 PARTICLE ACCELERATORS↗

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned↗

Far-field coupling in nanobeam photonic crystal cavities

We optimized the far-field emission pattern of one-dimensional photonic crystal nanobeams by modulating the nanobeam width, forming a sidewall Bragg cross-grating far-field coupler. By setting the period of the cross-grating to twice the photonic crystal period, we showed using three-dimensional finite-difference time-domain simulations that the intensity extracted to the far-field could be improved by more than three orders of magnitude compared to the unmodified ideal cavity geometry. We then experimentally studied the evolution of the quality factor and far-field intensity as a function of cross-grating coupler amplitude. High quality factor (>4000) blue (λ = 455 nm) nanobeam photonic crystals were fabricated out of GaN thin films on silicon incorporating a single InGaN quantum well gain medium. Micro-photoluminescence spectroscopy of sets of twelve identical nanobeams revealed a nine-fold average increase in integrated far-field emission intensity and no change in average quality factor for the optimized structure compared to the unmodulated reference. These results are useful for research environments and future nanophotonic light-emitting applications where vertical in- and out-coupling of light to nanocavities is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000↗

Super-resolution within a one-dimensional phononic crystal of resonators using time reversal in an equivalent circuit model

An equivalent circuit model has been developed to model a one-dimensional waveguide with many side-branch Helmholtz resonators. This waveguide constitutes a phononic crystal that has been shown to have decreased phase speed below the resonance frequency of an individual resonator. This decreased phase speed can be exploited to achieve super-resolution using broadband time reversal focusing techniques. It is shown that the equivalent circuit model is capable of quantifying this change in phase speed of the crystal and also the small-scale wave-resonator interactions within the crystal. The equivalent circuit model enables the parameterization of the physical variables and the optimization of the focusing bandwidth by balancing the combination of increasing resolution and decreasing amplitude near the resonance frequency. It is shown that the quality factor—in this case, the quality factor determined by the geometric shape of each resonator—controls the range of frequencies that are strongly affected by the Helmholtz resonators.

Kingsley, Adam D.↗

An air-spaced terahertz metamaterial perfect absorber

Metamaterial absorbers are typically comprised of a layer of split-ring resonators and a ground plane with a dielectric spacer layer that provides structural support and in which absorbed energy is deposited. For this work, we address the question “What happens to the absorption if the spacer layer is removed?” through the design, fabrication, and characterization of a terahertz metamaterial absorber with air as the spacer layer. Reflection based terahertz time-domain spectroscopy was employed to measure the absorption and interference theory was used to interpret the results. The surface current in the gold ground plane and split-ring resonator layer is solely responsible for the absorption in the form of joule heating. In comparison to dielectric spacer layer absorbers, the quality factor is increased by a factor of ~3. The electric field is highly concentrated in the volume between split-ring resonator layer and the ground plane offering the potential for novel sensing application if materials can be incorporated into this region (e.g. with microfluidics). In the spirit of this possibility, simulations of the absorption have been performed. The variation of the real part of the permittivity of the spacer material results in an absorption peak frequency shift, while a change in the imaginary part affects the quality factor and amplitude. Ultimately, the high quality factor and the absence of the spacer material provide the air-spacer metamaterial absorber with unique advantages for sensing applications.

42 ENGINEERING↗

AlN/SiC MEMS for High-Temperature Applications

The creation of microelectromechanical systems (MEMS) that can operate through elevated temperatures would enable systems diagnostics and controls that are not possible with conventional-off-the-shelf components. The integration of silicon carbide (SiC) with aluminum nitride (AlN) has led to the fabrication of devices that can withstand elevated temperature anneals >935 °C. The results from a piezoelectric micromachined ultrasonic transducer (PMUT) and a microresonator are reported as demonstrations of the fabrication process. Testing the PMUT response before and after annealing at 935 °C led to a change in resonant frequency of less than 1%, which is attributable to a shift in film stress. The response of the microresonator was RF tested in situ up to 500 °C and showed no degradation in its electromechanical coupling coefficient. The resonant frequency decreased with temperature due to the temperature coefficient of Young's modulus, and the quality factor decreased with temperature and remained unrecoverable upon cooling. The degradation in the quality factor is suspected to be a result of oxidation of the titatium nitride (TiN) top electrode, which increases the resistivity and leads to an unrecoverable reduction in the quality factor. As a result, the robust piezoelectric response of AlN at these temperatures show that AlN is a very promising candidate for elevated temperature applications. [2019-0019]

42 ENGINEERING↗