Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantum interference devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Templated fabrication and characterization of SiO{sub 2} nanotube covered Fe nanowires

In this study, Fe nanowires coated with SiO{sub 2} nanotubes have been synthesized by electrodeposition method using anodic alumina oxide template. Before growing Fe nanowires, 6–8 nm thick SiO{sub 2} nanotubes are grown inside the template using a “surface sol-gel” technique. The nanotube structures were characterized by field emission scanning electron microscopy and energy dispersive x-ray spectroscopy. Magnetic properties of the SiO{sub 2} insulated Fe nanowires inside the membrane are characterized by superconducting quantum interference device. Coercivities of around 120 Oe with field parallel to the nanowire axis and 240 Oe with field perpendicular the nanowire axis are observed at room temperature. These values are comparable to Fe nanowires without insulating layer in membrane. The magnetic hysteresis loop suggests that the SiO{sub 2} insulated nanowires have uniaxial magnetic anisotropy with the easy axis magnetization direction along the nanowire arrays due to their large shape anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Titanium nitride as a seed layer for Heusler compounds

Titanium nitride (TiN) shows low resistivity at room temperature (27 μΩ cm), high thermal stability and thus has the potential to serve as seed layer in magnetic tunnel junctions. High quality TiN thin films with regard to the crystallographic and electrical properties were grown and characterized by x-ray diffraction and 4-terminal transport measurements. Element specific x-ray absorption spectroscopy revealed pure TiN inside the thin films. To investigate the influence of a TiN seed layer on a ferro(i)magnetic bottom electrode in magnetic tunnel junctions, an out-of-plane magnetized Mn{sub 2.45}Ga as well as in- and out-of-plane magnetized Co{sub 2}FeAl thin films were deposited on a TiN buffer, respectively. The magnetic properties were investigated using a superconducting quantum interference device and anomalous Hall effect for Mn{sub 2.45}Ga. Magneto optical Kerr effect measurements were carried out to investigate the magnetic properties of Co{sub 2}FeAl. TiN buffered Mn{sub 2.45}Ga thin films showed higher coercivity and squareness ratio compared to unbuffered samples. The Heusler compound Co{sub 2}FeAl showed already good crystallinity when grown at room temperature on a TiN seed-layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrothermal synthesis and magnetic properties of {alpha}-MnO{sub 2} nanowires

Highlights: Black-Right-Pointing-Pointer {alpha}-MnO{sub 2} nanowires were synthesized through the hydrothermal method. Black-Right-Pointing-Pointer Ferromagnetism was observed in the {alpha}-MnO{sub 2} nanowires at 5 K. Black-Right-Pointing-Pointer The N{sub 2} adsorption-desorption experiment shows that surface area of {alpha}-MnO{sub 2} nanowires is 160.4 m{sup 2} g{sup -1}. -- Abstract: In the present study, one-dimensional (1D) {alpha}-MnO{sub 2} nanowires with width of 50-60 nm, length about several micrometers have been successfully prepared under hydrothermal conditions in the presence of sodium carboxymethyl cellulose. The samples were characterized by X-ray diffraction, scanning electron microscope, superconducting quantum interference device and N{sub 2} adsorption-desorption experiment. The magnetic measurement reveals that the {alpha}-MnO{sub 2} nanowires exhibit a ferromagnetic behavior at 5 K and a paramagnetic behavior at 300 K. The N{sub 2} adsorption-desorption experiment shows that surface area is 160.4 m{sup 2} g{sup -1}, which is even larger than those of mesoporous nanostructures. At the same time, the possible formation mechanism for the formation of {alpha}-MnO{sub 2} nanowires has been proposed according to the experimental results.

36 MATERIALS SCIENCE↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

Completely inverted hysteresis loops: Inhomogeneity effects or experimental artifacts

Completely inverted hysteresis loops (IHL) are obtained by the superconducting quantum interference device with large cooling fields (>10 kOe) in (La,Sr)MnO{sub 3} films with self-assembled LaSrMnO{sub 4}, an antiferromagnetic interface. Although the behaviours of measured loops show many features characteristic to the IHL, its origin, however, is not due to the exchange coupling between (La,Sr)MnO{sub 3}/LaSrMnO{sub 4}, an often accepted view on IHL. Instead, we demonstrate that the negative remanence arises from the hysteresis of superconducting coils, which drops abruptly when lower cooling fields are utilized. Hence the completely inverted hysteresis loops are experimental artifacts rather than previously proposed inhomogeneity effects in complicated materials.

36 MATERIALS SCIENCE↗

Experimental and first-principles study of ferromagnetism in Mn-doped zinc stannate nanowires

Room temperature ferromagnetism was observed in Mn-doped zinc stannate (ZTO:Mn) nanowires, which were prepared by chemical vapor transport. Structural and magnetic properties and Mn chemical states of ZTO:Mn nanowires were investigated by X-ray diffraction, superconducting quantum interference device (SQUID) magnetometry and X-ray photoelectron spectroscopy. Manganese predominantly existed as Mn{sup 2+} and substituted for Zn (Mn{sub Zn}) in ZTO:Mn. This conclusion was supported by first-principles calculations. Mn{sub Zn} in ZTO:Mn had a lower formation energy than that of Mn substituted for Sn (Mn{sub Sn}). The nearest neighbor Mn{sub Zn} in ZTO stabilized ferromagnetic coupling. This observation supported the experimental results.

36 MATERIALS SCIENCE↗

Auditory evoked field measurement using magneto-impedance sensors

The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

60 APPLIED LIFE SCIENCES↗

Characterization of Aliased Noise in the Advanced ACTPol Receiver

Advanced ACTPol is the second-generation polarization-sensitive upgrade to the 6m aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices to achieve a multiplexing factor as high as 64 (rows), fielding a 2012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1716 detectors each. In a time-domain system, aliasing introduces noise to the readout. Here in this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of ac and dc magnetometers with a Dy{sub 2}O{sub 3} standard

The ac susceptibility and magnetization curves of a glued Dy{sub 2}O{sub 3} powder sample are measured by an ac susceptometer and a dc superconducting quantum interference device magnetometer, both of which have been calibrated previously. It is shown that the magnetic moment of the paramagnetic sample as a function of field and temperature may be accurately expressed by a combination of the Curie-Weiss law and the Langevin function at T > 45 K with three adjusting parameters, so that the dc magnetization curves and the magnitude and phase of ac susceptibility at different values of dc bias field measured by any magnetometer can be calibrated by using Dy{sub 2}O{sub 3} as a standard. The expressions are empirical and cannot be justified in the entire field and temperature range by existing theories of paramagnetism. Below 10 K, indication of approaching a possible phase transition is found. It is shown that pure Dy{sub 2}O{sub 3} powder may be used as a primary standard, with susceptibility [13.28(T+ 17)]{sup -1} emu/Oe/g at T > 50 K and H < 10 kOe, in consistency with the Curie-Weiss law and the quantum mechanical theory of paramagnetism.

36 MATERIALS SCIENCE↗

Hysteretic Superconducting Heat-Flux Quantum Modulator

In this work, we discuss heat transport in a thermally biased superconducting quantum-interference device (SQUID) in the presence of an external magnetic flux, when a non-negligible inductance of the SQUID ring is taken into account. A properly sweeping driving flux causes the thermal current to modulate and behave hysteretically. The response of this device is analyzed as a function of both the hysteresis parameter and the degree of asymmetry of the SQUID, highlighting the parameter range over which hysteretic behavior is observable. Markedly, the temperature of the SQUID also shows hysteretic evolution, with sharp transitions characterized by temperature jumps up to, e.g., approximately 0.02 K for a realistic Al-based setup. In view of these results, the proposed device can effectively find an application as a temperature-based superconducting memory element, working even at gigahertz frequencies by suitably choosing the superconductor on which the device is based.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong parametric dispersive shifts in a statically decoupled two-qubit cavity QED system

Qubits in cavity quantum electrodynamic (QED) architectures are often operated in the dispersive regime, in which the operating frequency of the cavity depends on the energy state of the qubit, and vice versa. The ability to tune these dispersive shifts provides additional options for performing either quantum measurements or logical manipulations. Here we couple two transmon qubits to a lumped-element cavity through a shared superconducting quantum interference device (SQUID). In this work, our design balances the mutual capacitive and inductive circuit components so that both qubits are statically decoupled from the cavity with low flux sensitivity, offering protection from decoherence processes. Parametric driving of the SQUID flux enables independent, dynamical tuning of each qubit’s interaction with the cavity. As a practical demonstration, we perform pulsed parametric dispersive readout of both qubits. The dispersive frequency shifts of the cavity mode follow the theoretically expected magnitude and sign. This parametric approach creates an extensible, tunable cavity QED framework with various future applications, such as entanglement and error correction via multi-qubit parity readout, state and entanglement stabilization, and parametric logical gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Source localization of brain activity using helium-free interferometer

To detect extremely small magnetic fields generated by the human brain, currently all commercial magnetoencephalography (MEG) systems are equipped with low-temperature (low-T{sub c}) superconducting quantum interference device (SQUID) sensors that use liquid helium for cooling. The limited and increasingly expensive supply of helium, which has seen dramatic price increases recently, has become a real problem for such systems and the situation shows no signs of abating. MEG research in the long run is now endangered. In this study, we report a MEG source localization utilizing a single, highly sensitive SQUID cooled with liquid nitrogen only. Our findings confirm that localization of neuromagnetic activity is indeed possible using high-T{sub c} SQUIDs. We believe that our findings secure the future of this exquisitely sensitive technique and have major implications for brain research and the developments of cost-effective multi-channel, high-T{sub c} SQUID-based MEG systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multilayer MgB{sub 2} superconducting quantum interference filter magnetometers

We report two types of all-MgB{sub 2} superconductive quantum interference filter (SQIF) magnetometers that can measure absolute magnetic fields with high sensitivity. In one configuration, the SQIFs were made of 20 multilayer nonplanar all-MgB{sub 2} superconducting quantum interference devices (SQUIDs) connected in parallel with loop areas ranging in size from 0.4 to 3.6 μm{sup 2}. These devices are sensitive to magnetic fields parallel to the substrate and show a single antipeak from 3 to 16 K with a maximum transfer function of ∼16 V/T at 3 K and a field noise of ∼110 pT/Hz{sup 1/2} above 100 Hz at 10 K. In a second configuration, the SQIFs were made with 16 planar SQUIDs connected in parallel with loop areas ranging in size from 4 μm{sup 2} to 25 μm{sup 2} and are sensitive to the magnetic fields perpendicular to the substrate. The planar SQIF shows a single antipeak from 10 to 22 K with a maximum transfer function of 7800 V/T at 10 K and a field noise of ∼70 pT/Hz{sup 1/2} above 100 Hz at 20 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Voltage-driven, local, and efficient excitation of nitrogen-vacancy centers in diamond

Magnetic sensing technology has found widespread application in a diverse set of industries including transportation, medicine, and resource exploration. These uses often require highly sensitive instruments to measure the extremely small magnetic fields involved, relying on difficult-to-integrate superconducting quantum interference devices and spin-exchange relaxation-free magnetometers. A potential alternative, nitrogen-vacancy (NV) centers in diamond, has shown great potential as a high-sensitivity and high-resolution magnetic sensor capable of operating in an unshielded, room-temperature environment. Transitioning NV center–based sensors into practical devices, however, is impeded by the need for high-power radio frequency (RF) excitation to manipulate them. We report an advance that combines two different physical phenomena to enable a highly efficient excitation of the NV centers: magnetoelastic drive of ferromagnetic resonance and NV-magnon coupling. Our work demonstrates a new pathway that combine acoustics and magnonics that enables highly energy-efficient and local excitation of NV centers without the need for any external RF excitation and, thus, could lead to completely integrated, on-chip, atomic sensors.

42 ENGINEERING↗

Emulation of complex open quantum systems using superconducting qubits

With quantum computers being out of reach for now, quantum simulators are alternative devices for efficient and accurate simulation of problems that are challenging to tackle using conventional computers. Quantum simulators are classified into analog and digital, with the possibility of constructing “hybrid” simulators by combining both techniques. Here we focus on analog quantum simulators of open quantum systems and address the limit that they can beat classical computers. In particular, as an example, we discuss simulation of the chlorosome light-harvesting antenna from green sulfur bacteria with over 250 phonon modes coupled to each electronic state. Furthermore, we propose physical setups that can be used to reproduce the quantum dynamics of a standard and multiple-mode Holstein model. The proposed scheme is based on currently available technology of superconducting circuits consist of flux qubits and quantum oscillators.

97 MATHEMATICS AND COMPUTING↗

Piezoresponse and magnetic properties of multiferroic (1−x)Bi{sub 0.9}Dy{sub 0.1}FeO{sub 3}–xPbTiO{sub 3} solid solution

The multiferroic solid solution of (1−x)[0.9BiFeO{sub 3}–0.1DyFeO{sub 3}]–xPbTiO{sub 3} with compositions around the morphotropic phase boundary has been synthesized in the form of ceramics and characterized by Piezoresponse Force Microscope (PFM) and Superconducting Quantum Interference Device. Both the original local polar domain structure and the domain evolution after poling have been studied by PFM. The PFM phase imaging has revealed some interesting details of poling and domain switching process: The out-of-plane phase image shows a uniform direction of polarization along the applied electric field, while the in-plane phase image indicates two kinds of domains with antiparallel polarizations. This kind of poled domain structure is explained based on the orientations of the polarization as permitted by the rhombohedral crystal symmetry in grains of different crystallographic orientations. The magnetic properties measured within the temperature range from 1.8 K to 300 K reveal an interesting sequence of magnetic transitions from a weakly ferromagnetic order (WFM{sub 1}) to an antiferromagnetic state (AFM), and then to another weak ferromagnetic phase (WFM{sub 2}), upon cooling. A preliminary magnetic phase diagram is proposed for BDF-34PT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Magnetic Sensitivity of AlMn TESes and Shielding Considerations for Next-Generation CMB Surveys

In the next decade, new ground-based cosmic microwave background (CMB) experiments such as Simons Observatory, CCAT-prime, and CMB-S4 will increase the number of detectors observing the CMB by an order of magnitude or more, dramatically improving our understanding of cosmology and astrophysics. These projects will deploy receivers with as many as hundreds of thousands of transition edge sensor (TES) bolometers coupled to superconducting quantum interference device (SQUID)-based readout systems. It is well known that superconducting devices such as TESes and SQUIDs are sensitive to magnetic fields. However, the effects of magnetic fields on TESes are not easily predicted due to the complex behavior of the superconducting transition, which motivates direct measurements of the magnetic sensitivity of these devices. We present comparative four-lead measurements of the critical temperature versus applied magnetic field of AlMn TESes varying in geometry, doping, and leg length, including Advanced ACT and POLARBEAR-2/Simons Array bolometers. MoCu ACTPol TESes are also tested and are found to be more sensitive to magnetic fields than the AlMn devices. We present an observation of weak-link-like behavior in AlMn TESes at low critical currents. We also compare measurements of magnetic sensitivity for time division multiplexing SQUIDs and frequency division multiplexing microwave (mMUX) rf-SQUIDs. We discuss the implications of our measurements on the magnetic shielding required for future experiments that aim to map the CMB to near-fundamental limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗