Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Developing Low Noise, Rad-hard Detectors for Parity Violating Experiments

As parity-violating electron scattering (PVeS) experiments continue to push the frontiers of precision electro-weak asymmetry measurements, the demands on the experimental techniques and apparatus are also pushed. In particular, the need for higher resolution and radiation-hardness of the main integrating detectors has increased over the successive generations of PVeS experiments. The demand for precise measurement of GHz event rates has pushed the field toward the use of thin quartz Cerenkov light based detectors. We have been designing and testing such thin quartz detectors specifically for the upcoming experiments at Jefferson Lab, PREX-II and CREX, but this work also greatly influences the detector development for several future experiments including MOLLER at Jefferson Lab. These are all PVeS experiments that will use the new thin quartz Cerenkov detector design concept for their main asymmetry measurements (as well as for beam monitoring). The new design concept gives not only significant performance improvements compared to its predecessor from PREX-I, but also we have now thoroughly characterized its operational design and performance using a combination of test-beam data and detailed particle and optical Monte Carlo Geant4 simulations. These activities have culminated in the development and implementation of a "bench-marked" Monte Carlo package, QSIM, which constitutes a powerful design tool for present and future PVeS quartz detectors. The benchmarked simulation can replicate real photoelectron distributions (RMS and Mean) from testbeam data with ~5% precision – limited mainly by the systematic uncertainty of the PMT gain measurements.

Villarreal, Carlos Bula Villarreal↗

Rad Waste Cost/Volume Reduction Using New Monitoring/Decon Techniques, Launderable Items and Recycling - 19297

The use of improved radiation monitoring and decontamination techniques significantly reduces the cost and volume of Canadian radioactive waste via recycling/reuse. Over 2,700 metric tons of scaffolding and tooling have been released for unrestricted use back to the owners or recycled as non-radioactive scrap metal over the last 10 years. Additionally, using reusable launderable items reduces the cost over single use Radiological Personal Protective Equipment (RPPE) and plastic wraps and has eliminated thousands of cubic meters of Canadian station waste each year for over 10 years. The combined effect is the significant volume reduction of radioactive waste in a low risk, cost effective, manner. This paper and presentation will highlight the processes and showcase the types of materials decontaminated. The intent is to make waste generators aware of new processes that could be applied to the waste materials stored in their vaults or generated during a refurbishment/decommissioning project as well as day-to-day power generation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Rad Lab for Los Alamos

The topping out ceremony for a key construction stage in the Los Alamos National Laboratory's newest facility, the Radiological Laboratory Utility & Office Building.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation-Hardened Solid-State Drive

A method is provided for a radiationhardened (rad-hard) solid-state drive for space mission memory applications by combining rad-hard and commercial off-the-shelf (COTS) non-volatile memories (NVMs) into a hybrid architecture. The architecture is controlled by a rad-hard ASIC (application specific integrated circuit) or a FPGA (field programmable gate array). Specific error handling and data management protocols are developed for use in a rad-hard environment. The rad-hard memories are smaller in overall memory density, but are used to control and manage radiation-induced errors in the main, and much larger density, non-rad-hard COTS memory devices. Small amounts of rad-hard memory are used as error buffers and temporary caches for radiation-induced errors in the large COTS memories. The rad-hard ASIC/FPGA implements a variety of error-handling protocols to manage these radiation-induced errors. The large COTS memory is triplicated for protection, and CRC-based counters are calculated for sub-areas in each COTS NVM array. These counters are stored in the rad-hard non-volatile memory. Through monitoring, rewriting, regeneration, triplication, and long-term storage, radiation-induced errors in the large NV memory are managed. The rad-hard ASIC/FPGA also interfaces with the external computer buses.

Sheldon, Douglas J.↗

Two tri-spin complexes based on gadolinium and nitronyl nitroxide radicals: Structure and ferromagnetic interactions

Three Radical-Ln(III)-Radical complexes based on nitronyl nitroxide radicals have been synthesized, structurally and magnetically characterized: [Gd(hfac){sub 3}(NITPhOEt){sub 2}] (1) (hfac=hexafluoroacetylacetonate, and NITPhOEt=4'-ethoxy-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide), [Gd(hfac){sub 3}(NITPhOCH{sub 2}Ph){sub 2}] (2) (NITPhOCH{sub 2}Ph=4'-benzyloxy-phenyl-4,4,5, 5-tetramethylimidazoline-1-oxyl-3-oxide) and [Lu(hfac){sub 3}(NITPhOCH{sub 2}Ph){sub 2}] (3). The X-ray crystal structure analyses show that the structures of the three compounds are similar and all consist of the isolated molecules, in which central ions Gd{sup III} or Lu{sup III} are coordinated by six oxygen atoms from three hfac and two oxygen atoms from nitronyl radicals. The magnetic studies show that in both of the two Gd{sup III} complexes, there are ferromagnetic Gd{sup III}-Rad interactions and antiferro-magnetic Rad-Rad interactions in the molecules (with J{sub Rad-Gd}=0.27 cm{sup -1}, j{sub Rad-Rad}=-2.97 cm{sup -1} for 1: and J{sub Rad-Gd}=0.62 cm{sup -1}, j{sub Rad-Rad}=-7.01 cm{sup -1} for 2). An analogous complex of [Lu(hfac){sub 3} (NITPhOCH{sub 2}Ph){sub 2}] (3) containing diamagnetic Lu{sup III} ions has also been introduced for further demonstrating the nature of magnetic coupling between radicals. - Graphical abstract: Two tri-spin complexes based on gadolinium-radical have been synthesized and characterized, the magnetic studies show that in the two complexes the Gd-radical interaction is ferromagnetic and the radical-radical interaction is antiferromagnetic. An analogous complex containing the diamagnetic Lu{sup III} ions has also been synthesized to further demonstrate the nature of the magnetic coupling between radicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preoperative Radiomic Approach to Evaluate Tumor-Infiltrating CD8{sup +} T Cells in Hepatocellular Carcinoma Patients Using Contrast-Enhanced Computed Tomography

Background: To help identify potential hepatocellular carcinoma (HCC) candidates for immunotherapies, we aimed to develop and validate a radiomics-based biomarker (Rad score) to predict the infiltration of tumor-infiltrating CD8{sup +} T cells in HCC patients, and to evaluate the correlation of Rad score with tumor immune characteristics. Methods: Overall, 142 HCC patients (n = 100 and n = 42 in the training and validation sets, respectively) were subjected to radiomic feature extraction. Imaging features and immunochemistry data of patients in the training set were subjected to elastic-net regularized regression analysis to predict the level of CD8{sup +} T cell infiltration. Results: A Rad score for CD8{sup +} T-cell infiltration, which contained seven variables, was developed and was validated in the validation set (area under the curve [AUC]: training set 0.751, 95% confidence interval [CI] 0.656–0.846; validation set 0.705, 95% CI 0.547–0.863). The decision curve indicated the clinical usefulness of the Rad score. A higher Rad score correlated with superior overall and disease-free survival outcomes (p = 0.012 and 0.0088, respectively). Using the pathological slides, we found that the Rad score positively correlated with the percentage of tumor-infiltrating lymphocytes (TILs; Spearman rho = 0.51, p < 0.0001). Moreover, the Rad score could also discriminate inflamed tumors from immune-desert and immune-excluded tumors (Kruskal–Wallis, p < 0.0001), and higher Rad scores could be found in patients with positive programmed cell death ligand 1 expression in tumor/immune cells, as well as those with positive programmed cell death protein 1 expression. Conclusion: The newly developed Rad score was a powerful predictor of CD8{sup +} T-cell infiltration, which could be useful in identifying potential HCC patients who can benefit from immunotherapies when validated in large-scale prospective cohorts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Terrestrial Sources of X-Ray Radiation and Their Effects on NASA Flight Hardware

X-rays are an energetic and penetrating form of ionizing electromagnetic radiation, which can degrade NASA flight hardware. The main concern posed by such radiation is degradation of active electronic devices and, in some cases, diodes. Non-electronic components are only damaged at doses that far exceed the point where any electronic device would be destroyed. For the purposes of this document, flight hardware can be taken to mean an entire instrument, the flight electronics within the instrument or the individual microelectronic devices in the flight electronics. This document will discuss and describe the ways in which NASA flight hardware might be exposed to x-rays, what is and isn't a concern, and how to tell the difference. First, we must understand what components in flight hardware may be vulnerable to degradation or failure as a result of being exposed to ionizing radiation, such as x-rays. As stated above, bulk materials (structural metals, plastics, etc.) are generally only affected by ionizing radiation at very high dose levels. Likewise, passive electronic components (e.g. resistors, capacitors, most diodes) are strongly resistant to exposure to x-rays, except at very high doses. The main concerns arise when active components, that is, components like discrete transistors and microelectronic devices, are exposed to ionizing radiation. Active components are designed to respond to minute changes in currents and voltages in the circuit. As such, it is not surprising that exposure to ionizing radiation, which creates ionized and therefore electrically active particles, may degrade the way the hardware performs. For the most part, the mechanism for this degradation is trapping of the charges generated by ionizing radiation by defects in dielectric materials in the hardware. As such, the degree of damage is a function of both the quantity of ionizing radiation exposure and the physical characteristics of the hardware itself. The metric that describes the level of exposure to ionizing radiation is total ionizing dose (TID). The unit of TID is the rad, which is defined as 100 ergs absorbed per gram of material. Dose can be expressed in other units, for example grays (gy), where 1 gy = 100 rads. The actual fluence of radiation needed to deliver a rad depends on the absorbing material, so units of dose are usually stated in reference to the material of interest. That is, for microelectronic devices, the unit of dose is generally rad (Si) or rad (SiO2). However, the definition of absorbed dose in this fashion has the advantage that the type of radiation causing the ionization can be normalized so that a realistic and adequate comparison can be made. The sensitivity of microelectronic parts to TID varies over many orders of magnitude. (Note: Doses to humans are typically expressed in rems-or roentgen-equivalent-man-which measures tissue damage, and depends on the type of radiation, as well as the dose in rads.) Thus far, the "softest" parts tested at NASA showed damage at 500 rads (Si), while parts that are radiation-hardened by design can remain functional to doses on the order of 107 rads (Si). This broad range of sensitivity highlights one of the most important considerations when considering the effects of radiation on electronic parts: In order to determine whether a radiation exposure is a concern for a particular part, one must understand the technologies used in the part and their vulnerabilities to TID damage. A NASA radiation expert should be consulted to obtain such information.

X-ray↗

Better Defining the Role of Total Neoadjuvant Radiation: Changing Paradigms in Locally Advanced Pancreatic Cancer

Background: This study was designed to better define the role of radiation (Neo-Rad) in addition to neoadjuvant multiagent chemotherapy (NAT) for the treatment of locally advanced pancreatic cancer. Methods: Retrospective cohort study using the NCDB. Individuals with AJCC clinical T3/T4 pancreatic carcinoma who underwent resection and multiagent chemotherapy were included. Kaplan–Meier, logistic-regression, and Cox proportional-hazard models were used for analysis. Results: A total of 2703 patients were included; 2039 had T3 and 664 had T4 tumors, and 1092 (40.4%) received Neo-Rad. Median follow-up was 22.5 months. During the study period, there was increased use of NAT and a decline in the use of Neo-Rad. Addition of Neo-Rad did not affect 30-day (2.51% vs. 3.24%, p = 0.272) or 90-day mortality (5.23% vs. 6.38%, p = 0.216). Neo-Rad was not associated with improved overall survival on univariable (25.95 vs. 24.7 months, p = 0.202), or multivariable analyses (hazard ratio [HR] 0.94; 95% confidence interval [CI] 0.85–1.05). Time from diagnosis to definitive surgery was increased by Neo-Rad (204 vs. 115 days, p < 0.001). Neo-Rad was associated with increased pathologic downstaging in T3 (32.8% vs. 14.4%) (odds ratio [OR] 2.90; 95% CI 2.30–3.66) and T4 tumors (88.9% vs. 77.8%) (OR 2.29; 95% CI 1.44–3.67); complete pathologic response (5.3% vs. 1.6%) (OR 2.89; 95% CI 1.73–4.83), and increased R0 resection rates (85.7% vs. 76.8%) (OR 1.79; 95% CI 1.44–2.23). Conclusions: The use of neoadjuvant therapy is increasing for the treatment of locally advanced pancreatic cancer. The addition of radiation to neoadjuvant chemotherapy is associated with improved antineoplastic effectiveness (downstaging, complete pathologic response), surgical resection (R0 rates), but has no effect on overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The radiated power limit in impurity seeded JET-ILW plasmas

The total radiated fraction is examined in high density H-mode plasmas (Greenwald fraction of about 85 %) in JET by the variation of the auxiliary heating power of Pheat = 14 MW-29 MW. An achieved radiation fraction of about 75 % at most has been observed in JET-ILW, which is less than the highest achievable (≈90 %) fraction in JET-C during the high radiative power scenarios with N2 seeding. It is shown that the maximal achievable total radiation fraction averaged over ELM cycles has a strong dependence on the radiation efficiency of the ELM energy, $θ_{rad}$: $\gamma^{max}_{rad,total}$ = 1 -$\frac {f_{ELM} x ΔW_{ELM}} {P_heat}$ (1- $θ_{rad}$). About 50 % and 16 % of the ELM induced diamagnetic energy drop (ΔW ELM ) radiates during the ELM in JET-C and JET-ILW, respectively, which corresponds to the maximum total radiated powers of $\gamma^{max}_{rad,JET-C}$ = 0.87 and $\gamma^{max}_{rad,JET-ILW}$ = 0.77. These values of the maximum of the radiative power fractions are in good agreement with $\gamma^{max}_{rad}$ experimentally observed in JET-C (90 %) and JET-ILW (75 %).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emittance and lifetime measurement with damping wigglers

National Synchrotron Light Source II (NSLS-II) is a new third-generation storage ring light source at Brookhaven National Laboratory. The storage ring design calls for small horizontal emittance (<1 nm-rad) and diffraction-limited vertical emittance at 12 keV (8 pm-rad). Achieving low value of the beam size will enable novel user experiments with nm-range spatial and meV-energy resolution. The high-brightness NSLS-II lattice has been realized by implementing 30-cell double bend achromatic cells producing the horizontal emittance of 2 nm rad and then halving it further by using several Damping Wigglers (DWs). This paper is focused on characterization of the DW effects in the storage ring performance, namely, on reduction of the beam emittance, and corresponding changes in the energy spread and beam lifetime. The relevant beam parameters have been measured by the X-ray pinhole camera, beam position monitors, beam filling pattern monitor, and current transformers. In this paper, we compare the measured results of the beam performance with analytic estimates for the complement of the 3 DWs installed at the NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing the pedestal magnetic field and magnetohydrodynamics radial structure with pedestal–scrape of layer electron cyclotron emission radiation inversion in H-mode plasma (invited)

Forward modeling is used to interpret inversion patterns of the pedestal–Scrape of Layer (SOL) Electron Cyclotron Emission (ECE) in DIII-D H-mode experiments. The modeling not only significantly improves the ECE data interpretation quality but also leads to the potential measurements of (1) the magnetic field strength |B| at the separatrix, (2) the pedestal |B| evolution during an inter-Edge Localized Mode (ELM) period, and (3) the pedestal Magnetohydrodynamics (MHD) radial structure. The ECE shine-through effect leads to three types of pedestal–SOL radiation inversions that are discussed in this paper. The first type of inversion is the non-monotonic T e,rad profile with respect to the major radius. Using the ECE frequency at the minimum T e,rad , the inversion can be applied to measure the magnetic field |B| at the separatrix and calibrate the mapping of the ECE channels with respect to the separatrix. The second type of inversion refers to the opposite phase between the radiation fluctuations δT e,rad at the pedestal and SOL. This δT e,rad phase inversion is sensitive to density and temperature fluctuations at the pedestal foot and, thus, can be used to qualitatively measure the MHD radial structure. The third type of inversion appears when the pedestal and SOL T e,rad evolve in an opposite trend, which can be used to infer the pedestal |B| field change during an inter-ELM period. Finally, the bandwidth effect on measuring δT e,rad due to pedestal MHD is also investigated in the radiation modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗