Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION FALL OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evaporation and propagation of liquid drop streams at vacuum pressures: Experiments and modeling

Evaporation of streams of liquid droplets in environments at vacuum pressures below the vapor pressure has not been widely studied. Here, experiments and simulations are reported that quantify the change in droplet diameter when a steady stream of ≈100 μm diameter drops is injected into a chamber initially evacuated to <10 –8 bar. In experiments, droplets fall through the center of a 0.8 m long liquid nitrogen cooled shroud, simulating infinity radiation and vapor mass flux boundary conditions. Furthermore, experimentally measured changes in drop diameters vary from ≈0 to 6 μm when the initial vapor pressure is increased from 10 –6 to 10 –3 bar by heating the liquid. Measured diameter changes are predicted by a model based on the Hertz-Knudsen equation. One uncertainty in the calculation is the “sticking coefficient” β. Assuming a constant β for all conditions studied here, predicted diameter changes best match measurements with β≈0.3. This value falls within the range of β reported in the literature for organic liquids. Finally, at the higher vapor pressure conditions considered here, the drop stream disperses transverse to the main flow direction. This spread is attributed to forces imparted by an absolute pressure gradient produced by the evaporating stream.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synchronizing the consistency relation

We study the N-point function of the density contrast to quadratic order in the squeezed limit during the matter-dominated (MD) and radiation-dominated (RD) eras in synchronous gauge. Since synchronous gauge follows the free-fall frame of observers, the equivalence principle dictates that in the gradient approximation for the long-wavelength mode there is only a single, manifestly time-independent consistency relation for the N-point function. This simple form is dictated by the initial mapping between synchronous and local coordinates, unlike Newtonian gauge and its correspondingly separate dilation and Newtonian consistency relations. Dynamical effects only appear at quadratic order in the squeezed limit and are again characterized by a change in the local background, also known as the separate universe approach. We show that for the 3-point function the compatibility between these squeezed-limit relations and second-order perturbation theory requires both the initial and dynamical contributions to match, as they do in single-field inflation. This clarifies the role of evolution or late-time projection effects in establishing the consistency relation for observable bispectra, which is especially important for radiation acoustic oscillations and for establishing consistency below the matter-radiation equality scale in the MD era. Defining an appropriate angle and time average of these oscillations is also important for making separate universe predictions of spatially varying local observables during the RD era, which can be useful for a wider range of cosmological predictions beyond N-point functions.

79 ASTRONOMY AND ASTROPHYSICS↗

Final LDRD report : advanced plastic scintillators for neutron detection.

This report summarizes the results of a one-year, feasibility-scale LDRD project that was conducted with the goal of developing new plastic scintillators capable of pulse shape discrimination (PSD) for neutron detection. Copolymers composed of matrix materials such as poly(methyl methacrylate) (PMMA) and blocks containing trans-stilbene (tSB) as the scintillator component were prepared and tested for gamma/neutron response. Block copolymer synthesis utilizing tSBMA proved unsuccessful so random copolymers containing up to 30% tSB were prepared. These copolymers were found to function as scintillators upon exposure to gamma radiation; however, they did not exhibit PSD when exposed to a neutron source. This project, while falling short of its ultimate goal, demonstrated the possible utility of single-component, undoped plastics as scintillators for applications that do not require PSD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new mechanism for generating broad band pulsar-like polarization

Observational data imply the presence of superluminal electric currents in pulsar magnetospheres. Such sources are not inconsistent with special relativity; they have already been created in the laboratory. Here we describe the distinctive features of the radiation beam that is generated by a rotating superluminal source and show that it consists of subbeams that are narrower the farther the observer is from the source: subbeams whose intensities decay as 1/R instead of 1/R{sup 2} with distance (R), the fields of its subbeams are characterized by three concurrent polarization modes: two modes that are 'orthogonal' and a third mode whose position angle swings across the subbeam bridging those of the other two, (iii) its overall beam consists of an incoherent superposition of such coherent subbeams and has an intensity profile that reflects the azimuthal distribution of the contributing part of the source (the part of the source that approaches the observer with the speed of light and zero acceleration), its spectrum (the superluminal counterpart of synchrotron spectrum) is broader than that of any other known emission and entails oscillations whose spacings and amplitudes respectively increase and decrease algebraically with increasing frequency, and the degree of its mean polarization and the fraction of its linear polarization both increase with frequency beyond the frequency for which the observer falls within the Fresnel zone. We also compare these features with those of the radiation received from the Crab pulsar.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of one-shot-per-crystal structure determination using Laue diffraction

Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

Radiation Effects on the Performance of Advanced Sulfur Monochloride Chlorination Processes

Advanced sulfur chloride-based chlorination technologies are being developed to enable efficient recycling of aluminum and zirconium-based materials used in the nuclear industry. However, the impacts of ionizing radiation on the performance of these sulfur chloride compounds are not well established, despite this being critical knowledge for assessing their feasibility and longevity under envisioned process conditions. Here, in the present article, we report on the effects of cobalt-60 gamma irradiation (≤ 5 MGy) on the aluminum alloy 6061 (AA6061-T6) chlorination yield in sulfur monochloride (S 2 Cl 2 ). Our findings indicate that, compared to nonirradiated solvent, radiation-induced changes in the chemical composition of S 2 Cl 2 —identified using Raman spectroscopy—afford an additional, dose-dependent exothermic process prior to the chlorination reaction’s typical thermodynamic behavior. We attribute this new process to reactions involving aluminum species (metal, oxide, or [oxy]hydroxides) and sulfur dichloride (SCl 2 ), an S 2 Cl 2 radiolysis product that accumulates with absorbed gamma dose, but is absent following an AA6061-T6 chlorination study. Despite the exothermicity of this new process, the overall yield of chlorination decreased with increasing preirradiation dose. Consequently, the chemical reactivity, specificity (aluminum metal vs aluminum passivation and corrosion layer constituents), and byproducts of SCl 2 must be more thoroughly evaluated to support the continued development of advanced S 2 Cl 2 chlorination technologies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ARMing the Edge: Designing Edge Computing–Capable Machine Learning Algorithms to Target ARM Doppler Lidar Processing

Abstract There is a need for long-term observations of cloud and precipitation fall speeds in validating and improving rainfall forecasts from climate models. To this end, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site at Lamont, Oklahoma, hosts five ARM Doppler lidars that can measure cloud and aerosol properties. In particular, the ARM Doppler lidars record Doppler spectra that contain information about the fall speeds of cloud and precipitation particles. However, due to bandwidth and storage constraints, the Doppler spectra are not routinely stored. This calls for the automation of cloud and rain detection in ARM Doppler lidar data so that the spectral data in clouds can be selectively saved and further analyzed. During the ARMing the Edge field experiment, a Waggle node capable of performing machine learning applications in situ was deployed at the ARM SGP site for this purpose. In this paper, we develop and test four algorithms for the Waggle node to automatically classify ARM Doppler lidar data. We demonstrate that supervised learning using a ResNet50-based classifier will classify 97.6% of the clear-air images and 94.7% of cloudy images correctly, outperforming traditional peak detection methods. We also show that a convolutional autoencoder paired with k -means clustering identifies 10 clusters in the ARM Doppler lidar data. Three clusters correspond to mostly clear conditions with scattered high clouds, and seven others correspond to cloudy conditions with varying cloud-base heights.

54 ENVIRONMENTAL SCIENCES↗

Doppler spectra from ARM Doppler Lidar during ARMing the Edge

There is a need for long-term observations of cloud and precipitation fall speeds in validating and improving rainfall forecasts from climate models. To this end, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site at Lamont, Oklahoma, hosts five ARM Doppler lidars that can measure cloud and aerosol properties. In particular, the ARM Doppler lidars record Doppler spectra that contain information about the fall speeds of cloud and precipitation particles. In this dataset, we provide the Doppler spectra from the ARM Doppler lidar at C1 recorded in April 2022 during ARMing the Edge.

54 ENVIRONMENTAL SCIENCES↗

Cementum structure in Beluga whale teeth

We report that a large fraction of the volume of Beluga whale (Delphinapterus leucas) teeth consists of cementum, a mineralized tissue which grows throughout the life of the animal and to which the periodontal ligaments attach. Annular growth bands or growth layer groups (GLGs) form within Beluga cementum, and this study investigates GLG structure using X-ray fluorescence mapping and X-ray diffraction mapping with microbeams of synchrotron radiation. The Ca and Zn fluorescent intensities and carbonated hydroxyapatite (cAp) diffracted intensities rise and fall together and match the light-dark bands visible in transmitted light micrographs. Within the bands of maximum Ca and Zn intensity, the ratio of Zn to Ca is slightly higher than in the minima bands. Further, the GLG cAp, Ca and Zn modulation is preserved throughout the cementum for durations >25 year.

36 MATERIALS SCIENCE↗

Non–linear bonding trends in maleonitrile-1,2–dithiolate complexes of the transuranium actinides

The trivalent actinides are produced in the nuclear fuel cycle during power production and provide the largest long-term radiation dose in used nuclear fuel. It is ideal for these elements to be removed from used nuclear fuel for disposal and a necessity for fuel recycling. A key challenge to this is the similarity of chemical behavior of the trivalent actinides to the lanthanides that are also present as fission products in used fuel. Thus far, some of the most effective separations of actinides from lanthanides utilise chelating agents containing sulfur moieties such as dithiophosphinates that selectively bind to actinide ions because of a greater bond covalency relative to lanthanide ions. Typically, greater differences between actinide and lanthanide ions are observable the more ligands and chelators bonds have a covalent character. Here, a series of complexes of the trivalent actinides Np(III) through Cf(III) (excluding Bk(III)) with maleonitrile-1,2-dithiolate (mnt 2– ) are synthesized along with their lanthanide counterparts (La(III) – Nd(III), Sm(III) – Gd(III), Dy(III)), in order to characterize the nature of chemical bonds with these metal ions and a polarizable, non-innocent, sulfur-donor ligand. The metal-sulfur bonds in these complexes trend shorter than measured for lanthanides with equivalent ionic radii. However, particularly large deviations are observed in the neptunium and plutonium complexes in both structure and bonding, resulting in a nonlinear bond length trendline for the actinide series. Density Functional Theory (DFT) calculations with Quantum Theory of Atoms in Molecules (QTAIM) and Natural Bond Order (NBO) analyses indicate that for the neptunium and plutonium complexes, the presence of increased 5f-orbital participation, energy degeneracy of the metal and ligand orbitals, and the structure packing result in shortened M–S bonds. The stabilization of the energy of the 5f-orbitals and the decrease in f-contribution to bonding orbitals in the later actinides results in structural properties more similar to the lanthanide complexes.

07 ISOTOPE AND RADIATION SOURCES↗

Photonuclear production of 225 Ac from 226 Ra targets

Herein we report proof of principal production of 225 Ac via 226 Ra(γ , n) 225 Ra $\overset{^-β}{\rightarrow}$ 225 Ac and subsequent chemical separation via extraction chromatography using BDGA and Ln resins. Irradiation of 0.35 µg 226 Ra with 39 MeV bremsstrahlung end-point energy photons produced 225 Ra and 224 Ra at a rate of 754 and 2215 kBq/g 226 Ra/mA/h, respectively. The production rate of 225 Ac determined at its peak radioactivity was 335 kBq/g 226 Ra/mA/h. Radiochemically pure 225 Ac was isolated with a minimum separation factor of 125,000 for 225 Ac: 226 Ra. In conclusion, these results are promising and lay the foundation for future studies to scale-up production for preclinical quantities of high purity 225 Ac using the 226 Ra(γ , n) 225 Ra $\overset{^-β}{\rightarrow}$ 225 Ac approach.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

SU-E-T-588: Characterization and Clinical Validation of the Varian Pivotal™ Treatment Solution for Prone Breast Care

Purpose: To report on the clinical validation of the Varian Pivotal™ Treatment Solution for Prone Breast Care: a platform for prone breast radiation therapy. Methods: Patients treated using Breast Conserving Radiation Therapy may benefit from treatment in the prone position with the breast tissue falling freely away from the body. This geometry allows the breast tissue to be treated while avoiding the lung and heart tissue. Eighteen patients simulated and treated using the Varian Medical Systems Pivotal™ Treatment Solution for Prone Breast Care were monitored over the course of treatment for positioning integrity and reproducibility. As this carbon-fiber platform actually replaces a portion of the couch top, indexing is inherent to its design. Patients were positioned on the couch and aligned using fiducial markers and lateral SSD to the breast fiducial point. The daily couch coordinates then serves as indicators for positioning variability with this system. Results: The variations in couch vertical, longitudinal and lateral positions were centered on a mean value of zero with standard deviations of 0.44cm, 0.75cm and 0.79cm respectively. Other factors explored were variations in distance of mid-sternum to table edge and patient rotation into the opening. The median rotation of the chest wall was found to be 11.5 degrees at CT-Simulation with a median distance of 2.5cm from midsternum to support opening. Patient rotation was not associated with either breast size or distance from edge of platform. Conclusion: The Pivotal™ Treatment solution consists of a couch top that replaces the standard top and as such is open from beneath without obstruction. This is a distinction from all other solutions which rely on a platform positioned above and indexed to the treatment couch. We found the reproducibility to be consistent with our historical measures while offering benefits of an integrated solution as stated above. supported by Professional Services Agreeement with Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-648: Sharpening Dose Fall-Off Via Beam Number Enhancements For Stereotactic Brain Radiosurgery

Purpose: Sharp dose fall-off is the hallmark of brain radiosurgery to deliver a high dose of radiation to the target while minimizing dose to normal brain tissue. In this study, we developed a technique for the purpose of enhancing the peripheral dose gradient by magnifying the total number of beams focused toward each isocenter via patient head tilt and simultaneous beam intensity modulations. Methods: Computer scripting for the proposed beam number enhancement (BNE) technique was developed. The technique was tested and then implemented on a clinical treatment planning system for a dedicated brain radiosurgical system (GK Perfexion, Elekta Oncology). To study technical feasibility and dosimetric advantages of the technique, we compared treatment planning quality and delivery efficiency for 20 radiosurgical cases previously treated at our institution. These cases included relatively complex treatments such as acoustic schwannoma, meningioma, brain metastasis and mesial temporal lobe epilepsy. Results: The BNE treatment plans were found to produce nearly identical target volume coverage (absolute value < 0.5%, P > 0.2) and dose conformity (BNE CI= 1.41±0.15 versus 1.41±0.20, P>0.9) as the original treatment plans. The total beam-on time for theBNE treatment plans were comparable (within 1.0 min or 1.8%) with those of the original treatment plans for all the cases. However, BNE treatment plans significantly improved the mean gradient index (BNE GI = 2.9±0.3 versus original GI =3.0±0.3 p<0.0001) and low-level isodose volumes, e.g. 20-50% prescribed isodose volumes, by 2.0% to 5.0% (p<0.02). Furthermore, with 4 to 5-fold increase in the total number of beams, the GI decreased by as much as 20% or 0.5 in absolute values. Conclusion: BNE via head tilt and simultaneous beam intensity modulation is an effective and efficient technique that physically sharpens the peripheral dose gradient for brain radiosurgery.

60 APPLIED LIFE SCIENCES↗