Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE AEROSOLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Properties of mortars made by uncalcined FGD gypsum-fly ash-ground granulated blast furnace slag composite binder

Highlights: Black-Right-Pointing-Pointer The mortar with uncalcined FGD gypsum has suitable workability. Black-Right-Pointing-Pointer The strength of mortar with uncalcined FGD gypsum is higher than that of mortar without uncalcined FGD gypsum. Black-Right-Pointing-Pointer The dry shrinkage of mortar with uncalcined FGD gypsum is lower than that of mortar without uncalcined FGD gypsum. Black-Right-Pointing-Pointer The leaching of sulfate ion of mortar is studied. - Abstract: A series of novel mortars were developed from composite binder of uncalcined FGD gypsum, fly ash (FA) and ground granulated blast furnace slag (GGBFS) for the good utilization of flue gas desulphurization (FGD) gypsum. At a fixed ratio (20%) of GGBFS to the composite binder, keeping consistency of the mortar between 9.5 and 10.0 cm, the properties of the composite mortar were studied. The results show that higher water/binder (W/B) is required to keep the consistency when increasing the percentage of FGD gypsum. No obvious influences of the W/B and content of FGD gypsum on the bleeding of paste were observed which keeps lower than 2% under all experimental conditions tried. The highest compressive and flexural strengths (ratio is 20% FGD gypsum, 20% GGBFS and 60% FA) are 22.6 and 4.3 MPa at 28 days, respectively. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) results indicate that massive ettringite crystals and C-S-H gels exist in the hydration products. At 90 days the mortars with FGD gypsum is dramatically smaller drying shrinkage (563-938 micro strain) than that without FGD gypsum (about 2250 micro strain). The release of the SO{sub 4}{sup 2-} from the mortar was analyzed, indicating that the dissolution of sulfate increases with FGD gypsum. The concentration of SO{sub 4}{sup 2-} releasing from the mortar with 10% FGD gypsum is almost equal to that obtained from the mortar without FGD gypsum. The release of SO{sub 4}{sup 2-} from the mortar with 20% FGD gypsum is 9200 mg{center_dot}m{sup -2}, which is lower than that from the mortar with 95% cement clinker and 5% FGD gypsum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toxicity mitigation and solidification of municipal solid waste incinerator fly ash using alkaline activated coal ash

Highlights: Black-Right-Pointing-Pointer Incinerator fly ash (IFA) is added to an alkali activated coal fly ash (CFA) matrix. Black-Right-Pointing-Pointer Means of stabilizing the incinerator ash for use in construction applications. Black-Right-Pointing-Pointer Concrete made from IFA, CFA and IFA-CFA mixes was chemically characterized. Black-Right-Pointing-Pointer Environmentally friendly solution to IFA disposal by reducing its toxicity levels. - Abstract: Municipal solid waste (MSW) incineration is a common and effective practice to reduce the volume of solid waste in urban areas. However, the byproduct of this process is a fly ash (IFA), which contains large quantities of toxic contaminants. The purpose of this research study was to analyze the chemical, physical and mechanical behaviors resulting from the gradual introduction of IFA to an alkaline activated coal fly ash (CFA) matrix, as a mean of stabilizing the incinerator ash for use in industrial construction applications, where human exposure potential is limited. IFA and CFA were analyzed via X-ray fluorescence (XRF), X-ray diffraction (XRD) and Inductive coupled plasma (ICP) to obtain a full chemical analysis of the samples, its crystallographic characteristics and a detailed count of the eight heavy metals contemplated in US Title 40 of the Code of Federal Regulations (40 CFR). The particle size distribution of IFA and CFA was also recorded. EPA's Toxicity Characteristic Leaching Procedure (TCLP) was followed to monitor the leachability of the contaminants before and after the activation. Also images obtained via Scanning Electron Microscopy (SEM), before and after the activation, are presented. Concrete made from IFA, CFA and IFA-CFA mixes was subjected to a full mechanical characterization; tests include compressive strength, flexural strength, elastic modulus, Poisson's ratio and setting time. The leachable heavy metal contents (except for Se) were below the maximum allowable limits and in many cases even below the reporting limit. The leachable Chromium was reduced from 0.153 down to 0.0045 mg/L, Arsenic from 0.256 down to 0.132 mg/L, Selenium from 1.05 down to 0.29 mg/L, Silver from 0.011 down to .001 mg/L, Barium from 2.06 down to 0.314 mg/L and Mercury from 0.007 down to 0.001 mg/L. Although the leachable Cd exhibited an increase from 0.49 up to 0.805 mg/L and Pd from 0.002 up to 0.029 mg/L, these were well below the maximum limits of 1.00 and 5.00 mg/L, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological Monitoring of Waste Treatment Plant

Scheduled waste in West Malaysia is handled by Concession Company and is stored and then is incinerated. It is known that incineration process may result in naturally occurring radioactive materials (NORM) to be concentrated. In this study we have measured three samples consist of by-product from the operation process such as slag, filter cake and fly ash. Other various environmental media such as air, surface water, groundwater and soil within and around the plant have also been analysed for their radioactivity levels. The concentration of Ra-226, Ac-228 and K-40 in slag are 0.062 Bq/g, 0.016 Bq/g and 0.19 Bq/g respectively. The total activity (Ra{sub eq}) in slag is 99.5 Bq/kg. The concentration in fly ash is 0.032 Bq/g, 0.16 Bq/g and 0.34 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 287.0 Bq/kg. For filter cake, the concentration is 0.13 Bq/g, 0.031 Bq/g and 0.33 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 199.7 Bq/kg. The external radiation level ranges from 0.08 {mu}Sv/h (Administrative building) to 0.35 {mu}Sv/h (TENORM storage area). The concentration level of radon and thoron progeny varies from 0.0001 to 0.0016 WL and 0.0006 WL to 0.002 WL respectively. For soil samples, the activity ranges from 0.11 Bq/g to 0.29 Bq/g, 0.06 Bq/g to 0.18 Bq/g and 0.065 Bq/g to 0.38 Bq/g for Ra-226, Ac-228 and K-40 respectively. While activity in water, except for a trace of K-40, it is non-detectable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transporting Non-Compliant TRU Wastes in the OPTIMUS{sup TM} Packages - 20493

The OPTIMUS{sup TM} product line of packages was developed with the purpose of providing a versatile and modular packaging option for shipping problematic wastes and fissile material contents. The product line includes a high-activity design in the OPTIMUS-H and a low activity design in the OPTIMUS-L. The two variants utilize a singular containment vessel design, that is enclosed in different protective components that offer different levels of shielding along with thermal and impact protection. The thick shielding provided by the OPTIMUS-H packaging allows for higher activity contents than the OPTIMUS-L to be transported. But the lightweight design of the OPTIMUS-L packaging allows for more packages to be transported in a single shipment. The containment vessel design shared between the two packages provides leak-tight containment of all radioactive contents along with the capabilities to easily leak test and the option to inert and backfill the contents, as necessary, prior to each shipment of the package. Together the OPTIMUS package designs offer significant flexibility and are capable of handling a wide variety of waste materials and other radioactive contents. One of the primary contents covered in the initial design effort for these packages is TRU waste contents beyond the standard waste materials that are compliant with the WIPP Waste Acceptance Criteria. More specifically, the initial content of interest is TRU Waste drums containing sealed containers with potentially flammable gases. While there are multiple other packaging options available for transporting standard WIPP compliant TRU wastes, the goal of the OPTIMUS packages is to offer a superior option for transporting both standard TRU wastes as well as the more problematic non-compliant wastes, among other contents. The non-compliant TRU waste contents explicitly included for the OPTIMUS packages are standard aerosol cans and DOT 3E lecture bottles. However, the methods applied for the package containment can be easily adjusted to cover other sealed container types with potentially flammable gases. The primary challenges with including these items are both the obvious issue of potential for flammable gases (e.g. aerosol propellants) in the package, but also the uncertainty in the exact state of the contents. Because these desired contents are waste materials, the characterization of the materials present in the waste may include some uncertainties. For example, though it may be known that there are one or more aerosol cans in a TRU waste drum, it may not be known if this can is full, spent, or anywhere in between. Also there may be equal uncertainty in the contents of the aerosol can, specifically in the potentially flammable propellant remaining in the can. To include these types of non-compliant items as acceptable contents for the package, the methods utilized in the safety analyses of the OPTIMUS packages must consider all of the uncertainties in the characterization of the waste. The methods utilized cover a range of concerns with transporting contents of this nature including pressure buildup, gas generation, and gaseous combustion for demonstrating the containment of the package. The ability to transport these problematic contents in the OPTIMUS packages gives TRU waste generating sites the option to relocate these drums to an offsite location where the non-compliant items can be properly managed through removal or destruction. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dirty bomb source term characterization and downwind dispersion: Review of experimental evidence

Dirty bombs are considered one of the easiest forms of radiological terrorism, a form of terrorism based on the deliberate use of radiological material to cause adverse effects in a target population. One U.S. Government official has even described a dirty bomb attack as “all but inevitable”. While people in the vicinity of the blast may experience acute radiation effects, people downwind may unknowingly be contaminated by the radioactive airborne particulate and face increased long-term cancer risk. The likelihood of increased cancer risk depends on the radionuclide used and its specific activity, its aerosolization potential, the particle sizes generated in the blast, and where a person is with respect to the detonation. Different studies have reported that plausible radionuclides for dirty bomb include 60 Co, 90 Sr, 137 Cs, 192 Ir, 241 Am based on their availability in commercial sources as well as safeguards, the amount needed for adverse health effects, previous mishandling of radionuclides and malicious uses. In order to have increased long-term cancer risk, the radionuclide would have to deposit inside the body by entering the respiratory tract and then possibly migrate to other organs or bones (ground shine is not considered in this paper because areas affected by the event will likely become inaccessible). This implies that the particles will have to be smaller than 10 μm to be inhaled. Experiments involving the detonation of dirty bombs have shown that particles or droplets smaller than 10 μm are generated, independently from the initial radionuclide or its state (e.g., powder, solution). Atmospheric tests have shown that in unobstructed terrain, the radionuclide laden cloud can travel kilometers downwind even for relatively small amounts of explosives. Furthermore, buildings in the path of the cloud can change the dose rate. For instance, in one experiment with a single building, the dose rate was 1–2 orders of magnitude lower behind the obstacle compared to its front face. For people walking around, the amount of particulate deposited on them and inhaled will depend on their path relative to the cloud, resulting in the counterintuitive result that the closer people may actually not be the ones more at risk because they could simply miss the bulk of the cloud in their wandering. In summary, the long-term cancer risk for people caught in a dirty bomb cloud away from the detonation requires considering where and when the people are, which radionuclide was used, and the layout of the obstacles (e.g., buildings, vegetation) in the path of the cloud.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Alarm inhalation dosemeter for long living radioactive dust due to an uncontrolled release

MyRIAM is the acronym for My Radioactivity In Air Monitor and points out that the device was designed for personal use to detect any radioactivity in the air at the place and at the moment of danger. The active air sampling process enables a detection limit several orders of magnitude below that of Gamma detectors. Therefore, it is the unique way to detect dangerous exposures in time.Individual protection against inhalation of long living radioactive dust (LLRD) saves human life and health. LLRD may occur in natural environment as well as in case of nuclear accidence or military and terrorist attacks. But in any case, the immediate warning of the population is of great importance. Keep in mind: it is very easy to avoid LLRD inhalation--but you have to recognize the imminent danger. The second requirement of gap-less documentation and reliable assessment of any derived LLRD exposure is building the link to Dosimetry applications.The paper demonstrates the possibility to design small and low cost air samplers, which can be used as personal alarm dosimeters and fulfil the requirements mentioned above.Several test measurements taken by a mobile phone sized MyRIAM, shall be used to demonstrate the correctness of this statement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Morphological Characterization of Uranyl Fluoride Particles via Atomic Force Microscopy

Uranium hexafluoride (UF 6 ) undergoes a rapid hydrolysis reaction when exposed to atmospheric water. In addition to producing hazardous HF gas, the hydrolysis reaction produces uranyl fluoride (UO 2 F 2 ), a radioactive solid phase particulate material. Because of the technological utility of UF 6 in the nuclear fuel cycle, understanding the transport properties of UO 2 F 2 aerosol produced via UF 6 hydrolysis is important for accident scenarios. Moreover, the fundamental chemical and physical properties of the UF 6 hydrolysis reaction are not completely understood. Recently, several experiments on the aerosol phase properties of UO 2 F 2 produced in this way have shown that under most relevant conditions, the particle size distribution (PSD) of UO 2 F 2 can be extremely small, approximately 3 to 5 nm, which is well below the threshold that can be routinely observed via scanning electron microscopy (SEM). Although readily observable in the aerosol phase, observation of nanometer-sized particles in the condensed phase (i.e. deposited on surfaces) remains a challenge. Here, in this study, we have used atomic force microscopy (AFM) to study the PSD and morphological characteristics of UO 2 F 2 deposited at low and high concentrations under different humidity conditions, a primary variable in the hydrolysis reaction. Here, we find strong agreement between PSD measured in the aerosol phase via scanning mobility particle sizing and PSD measured via AFM, with particle sizes peaked below 4 nm for low-humidity conditions. At higher humidity, the distribution is centered around 5 to 10 nm but extends up to 20 nm. These results are in stark contrast to previous measurements using SEM that show PSD on the order of 300- to 1000-nm particle sizes; moreover, these are the first direct measurements of individual particles of UO 2 F 2 having been produced via UF 6 hydrolysis deposited on surfaces. These measurements, therefore, open a new avenue for collecting and detecting UO 2 F 2 in the condensed phase and further refine the PSD, which is critical for environmental transport determinations.

Uranium hexafluoride↗

Small-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MELCOR Input Model for Spent Fuel Transportation and Storage Canister

This report documents the progress and current results of the MELCOR spent fuel cask input model. The MELCOR model is being developed to investigate aerosol transport and deposition given the aerosol physical phenomena models within MELCOR. To perform the analyses, a general portrayal of the MAGNASTOR® cask system has been employed; however, this system was selected based on available information to provide a reasonable representation of a spent fuel cask. The analytical results are not intended to characterize the performance of the MAGNASTOR® cask. Instead, the provided results are intended to enhance our general understanding of the aerosol behavior within casks and the validity of current models. The current model efforts are being performed to investigate hypothetical UO 2 release from failed fuel pins within a spent fuel cask. The existing MELCOR model of the MAGNASTOR® cask system has been adapted to permit future comparative analyses with the GOTHIC representation of the MAGNASTOR® cask. To support this comparison, the PNNL model characteristics that are unrelated to the aerosol modeling were applied to the MELCOR model. These characteristics included improved comparability of the axial fidelity, total spent fuel power, fuel pin axial power profile, and heat losses from cannister. The thermal-hydraulic solutions are improved within the capability of the MELCOR code and will permit better overall agreement with the GOTHIC results. Detailed results are presented on the thermal-hydraulic analysis of the MELCOR cask as well as characterization of UO 2 aerosol dispersion and deposition within the cask.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diffusive deposition of aerosols in Phebus containment during FPT-2 test

At present the lumped-parameter codes is the main tool to investigate the complex response of the containment of Nuclear Power Plant in case of an accident. Continuous development and validation of the codes is required to perform realistic investigation of the processes that determine the possible source term of radioactive products to the environment. Validation of the codes is based on the comparison of the calculated results with the measurements performed in experimental facilities. The most extensive experimental program to investigate fission product release from the molten fuel, transport through the cooling circuit and deposition in the containment is performed in PHEBUS test facility. Test FPT-2 performed in this facility is considered for analysis of processes taking place in containment. Earlier performed investigations using COCOSYS code showed that the code could be successfully used for analysis of thermal-hydraulic processes and deposition of aerosols, but there was also noticed that diffusive deposition on the vertical walls does not fit well with the measured results. In the CPA module of ASTEC code there is implemented different model for diffusive deposition, therefore the PHEBUS containment model was transferred from COCOSYS code to ASTEC-CPA to investigate the influence of the diffusive deposition modelling. Analysis was performed using PHEBUS containment model of 16 nodes. The calculated thermal-hydraulic parameters are in good agreement with measured results, which gives basis for realistic simulation of aerosol transport and deposition processes. Performed investigations showed that diffusive deposition model has influence on the aerosol deposition distribution on different surfaces in the test facility. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of radon gas concentration in the aerosoles profile

Radon gases relased from building materials and from earth surface are the major responsibility of air ionization. Radon nuclear decay can produce an alpha particle with high energy and Radon progeny. This particle and gamma rays can deliver particles in the air and produce ions with different polarities. This ions, because of induced electric charge, can attach with air aerosols and charge them with their electric charge. The charged aerosols can interact with the other aerosols and ions. Because of this exchange, the air conductivity and the aerosol profiles will change dependently by Radon gas concentration and gamma radiation. Observations show an increase in concentration of Radon during the night, and a decrease during the daylight time. The Radon gas concentration changed hour by hour can induce aerosol profile to change. This dependency between the aerosol profiles and the Radon gas concentrations is discussed.

54 ENVIRONMENTAL SCIENCES↗

Scaled Tests and Modeling of Effluent Stack Sampling Location Mixing

The Pacific Northwest National Laboratory researchers used a computational fluid dynamics (CFD) computer code to evaluate the mixing at a sampling system location of a research and development facility. The facility requires continuous sampling for radioactive air emissions. Researchers sought to determine whether the location would meet the criteria for uniform air velocity and contaminant concentration as prescribed in the American National Standard Institute (ANSI) standard, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. Standard ANSI/HPS N13.1-1999 requires that the sampling location be well-mixed and stipulates specific tests (e.g., velocity, gas, and aerosol uniformity and cyclonic flow angle) to verify the extent of mixing.. The exhaust system for the Radiochemical Processing Laboratory was modeled with a CFD code to better understand the flow and contaminant mixing and to predict mixing test results. The CFD results were compared to actual measurements made at a scale-model stack and to the limited data set for the full-scale facility stack. Results indicated that the CFD code provides reasonably conservative predictions for velocity, gas, and aerosol uniformity. Cyclonic flow predicted by the code is less than that measured by the required methods. In expanding from small to full scale, the CFD predictions for full-scale measurements show similar trends as in the scale model and no unusual effects. This work indicates that a CFD code can be a cost-effective aid in design or retrofit of a facility’s stack sampling location that will be required to meet Standard ANSI/HPS N13.1-1999.

air monitoring↗

Anisole nitration during gamma-irradiation of aqueous nitrite and nitrate solutions: Free radical versus ionic mechanisms

Radiolytic aromatic nitration mechanisms in the condensed phase are ubiquitous, and especially of interest in atmospheric aerosol chemistry, water treatment by advanced oxidation technologies, and nuclear fuel reprocessing. Here, the radiolytically-induced nitration reactions of anisole, the simplest aryl alkyl ether, were investigated in ?-irradiated acidic nitrate solution, and in neutral nitrate and nitrite solutions. The nitrated anisole product distribution was the same with and without radiation in acidic solution, although more products were formed as a result of irradiation. This suggests that the mechanism of nitration in acidic solution is nitronium ion- induced electrophilic aromatic substitution. The rate of production of nitrated products in neutral nitrate solution was much lower, although the distribution of isomers was similar to that expected for nitronium ion electrophilic nitration. In contrast, the product distribution in neutral nitrite solution approached a statistically random substitution pattern, suggesting a non-electrophilic free radical reaction involving •NO2 radical. When hydroxyl radical (•OH) was scavenged by varying the initial nitrite concentration, the concentration of nitrated products increased with increasing nitrite, indicating that the reaction was probably one of direct •NO2 radical addition. However, this latter mechanism will not be important in acidic solutions, such as those often encountered in atmospheric aerosols or ?-irradiated nuclear fuel reprocessing solutions, due to low amounts of produced •NO2 radical and the low reaction rate constants for the •NO2 radical with aromatic compounds.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗

DEPDOSE

DEPDOSE is an open-source computer application which combines the KDEP respiratory tract deposition software with committed equivalent dose coefficient tables from the DC_PAK internal dosimetry package. DEPDOSE allows the user to rapidly produce tables of dose coefficients to workers and members of the public inhaling a precisely defined, user-specified aerosols using the ICRP 60 series methodology. Combined with a plume dispersion modeling system such as QUIC, this makes it possible to predict radiation doses downstream from an accidental or intentional release of radioactive materials. For this work, a radioactive plume was calculated to members of the public downstream from a plausible release of radionuclides into the atmosphere.

Klumpp, John↗

Radiological mapping of facilities under dismantling process by digital autoradiography - 15230

because safety standards have changed. In that context, radioactive waste management is a challenging task faced by existing nuclear power countries. Therefore, characterization is essential to classify wastes and to reduce costs. In many facilities, after the removal of glove boxes, fume cupboards and so on, the remaining materials on the floor, walls, and ceiling must be characterized. Gamma emitters can be detected remotely by commercial devices. However, analytical techniques to detect alpha and beta emitters in situ are generally not well suited for large area investigations. The Digital Autoradiography (DA) technique, initially dedicated to research in biology, was re-routed for final state characterization before facility demolition. It is based on the exposure of radio-sensitive phosphor screens on the materials to characterize. Phosphor screens, after a scanning process, provide a picture of the radioactivity, and are reusable several tens of times. This analytical technique is sensitive to all types of radioactivity, requires neither operators nor electricity during acquisition process, and produces only very few wastes. DA has already been tested in different facilities to obtain semi-quantitative values of C-14 and H-3 activities. Large amount of data gathered to cover the whole surface to be characterized. A Geographic Information System (GIS) associated with geostatistical method has been used to provide Radiological Mapping. This method to interpret Digital Autoradiography results has been proved very efficient to prepare remediation project. (authors)

54 ENVIRONMENTAL SCIENCES↗

Aerosol retention during SGTR meltdown sequences: Experimental insights of the effect of size and shape of the breach

This paper summarizes the major insights gained from aerosol retention capability of a tube bundle that simulates the break stage of the secondary side of a failed steam generator under dry SGTR conditions. This scenario is highly relevant in nuclear safety since it affects the potential retention of radioactive particles in case of meltdown sequences with a SGTR. An 8-test experimental campaign has been carried out, extending the current database on the decontamination capability of the steam generator. The effects of the breach features (shape and size) and the particle nature (SiO{sub 2} and TiO{sub 2}) on the collection efficiency have been explored. The results confirmed the strong effect of the physical nature even when tube breaks in a fish-mouth mode. Loose aggregates (i.e. TiO{sub 2}) would be trapped to a limited extent (less than 25%); while single- or few-aggregates (i.e. SiO{sub 2}) would undergo a quite effective removal (i.e. over 75%). For fish-mouth breaches and SiO{sub 2} particles, the breach size has been found to moderately affect retention efficiency. Furthermore, the breach shape does not seem to have any effect on the net collection efficiency within the break stage, no matter the particle type. However, individual tube measurements indicate notably different deposition patterns, although an effect of the facility geometry cannot be disregarded as a key player in this observation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aerosol Deposition Inside a Spent Fuel Transportation and Storage Canister (Interim Report)

This report documents the progress in preparing the ANSYS/Fluent ® and MELCOR models to perform characterization studies of aerosols dispersal and deposition within a select spent fuel cask system. Steady state thermal-hydraulic cask response is modeled with both codes, at present, while the MELCOR source code is being modified to allow imposed thermal-hydraulic conditions with aerosol physics calculations. This will allow the MELCOR model to assume the thermal-hydraulic calculation from the ANSYS/Fluent ® , while only computing the aerosol physics. Detailed results are presented on the thermal-hydraulic analysis of the MAGNASTOR ® cask for the current ANSYS/Fluent ® model, with convergent conditions observed over two fidelities. While the MELCOR computation computes the steady state conditions, they differ sufficiently from that computed with ANSYS/Fluent ® . The MELCOR analysis include a set of UO 2 sources to investigate system response for interim reporting. The airborne concentrations and evolving distributions are presented. Model development is anticipated to continue as additional components impacting flow conditions or aerosol deposition within the MAGNASTOR ® cask and Westinghouse fuel assemblies are identified.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗