RF deflecting cavity for fast radioactive ion beams

Abstract The Facility for Rare Isotope Beams (FRIB) will be a new scientific user facility that produces rare-isotope beams for experiments from the fragmentation of heavy ions at energies of 100–200 MeV/u. During the projectile fragmentation, the rare isotope of interest is produced along with many contaminants that need to be removed before the beam reaches detectors. At FRIB, this is accomplished with a magnetic projectile fragment separator. However, to achieve higher beam purity, in particular for proton-rich rare isotopes, additional purification is necessary. RadiaBeam in collaboration with Michigan State University (MSU) has designed a 20.125 MHz radiofrequency (RF) fragment separator capable of producing a 4 MV kick with 18 cm aperture in order to remove contaminant isotopes based on their time of flight. In this paper, we will discuss the RF and engineering design considerations of this separator cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variation of lead isotopic composition and atomic weight in terrestrial materials (IUPAC Technical Report)

The isotopic composition and atomic weight of lead are variable in terrestrial materials because its three heaviest stable isotopes are stable end-products of the radioactive decay of uranium ( 238 U to 206 Pb; 235 U to 207 Pb) and thorium ( 232 Th to 208 Pb). The lightest stable isotope, 204 Pb, is primordial. These variations in isotope ratios and atomic weights provide useful information in many areas of science, including geochronology, archaeology, environmental studies, and forensic science. While elemental lead can serve as an abundant and homogeneous isotopic reference, deviations from the isotope ratios in other lead occurrences limit the accuracy with which a standard atomic weight can be given for lead. In a comprehensive review of several hundred publications and analyses of more than 8000 samples, published isotope data indicate that the lowest reported lead atomic weight of a normal terrestrial materials is 206.1462 ± 0.0028 (k = 2), determined for a growth of the phosphate mineral monazite around a garnet relic from an Archean high-grade metamorphic terrain in north-western Scotland, which contains mostly 206 Pb and almost no 204 Pb. The highest published lead atomic weight is 207.9351 ± 0.0005 (k = 2) for monazite from a micro-inclusion in a garnet relic, also from a high-grade metamorphic terrain in north-western Scotland, which contains almost pure radiogenic 208 Pb. When expressed as an interval, the lead atomic weight is [206.14, 207.94]. It is proposed that a value of 207.2 be adopted for the single lead atomic-weight value for education, commerce, and industry, corresponding to previously published conventional atomic-weight values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surrogate isotope-containing materials for emergency response training and Methods of formation and dispersal

Surrogate materials are in the form of solid particles that include surrogate isotopes, namely, short-lived isotopes selected and formed to serve as surrogates for the radioactive materials of a nuclear fallout without including isotopes that are, or that decay to, biologically or environmentally deleterious and persistent isotopes. The surrogate material may be formed using high-purity reactant material and irradiation and separation techniques that enable tailoring of the isotopes and ratios thereof included in the surrogate material, and the surrogate material may be dispersed, e.g., in a training environment, in solid form.

Carney, Kevin P.↗

Laser Spectroscopy of Exotic Atoms and Molecules Containing Octupole-Deformed Nuclei

This project investigated the nuclear, atomic, and molecular structure of exotic atoms and molecules containing actinide isotopes. These short-lived radioactive systems are challenging to produce and study in the laboratory, yet they offer unique opportunities for fundamental science. These nuclei are predicted to exhibit pear-shaped (octupole) deformation, a rare collective nuclear behavior that dramatically enhances their sensitivity to fundamental physics phenomena such as time-reversal- and parity-violating effects. Such enhancements make them ideal probes for exploring open questions in our understanding of the universe such as the origin of the matter–antimatter asymmetry of the universe. To realize these measurements, the project led the development of a new laser spectroscopy experiment at MIT, and later commissioned at the Facility for Rare Isotope Beams (FRIB) at Michigan State University: the Resonance Ionization Spectroscopy Experiment (RISE). RISE combines the spectroscopic precision of collinear laser spectroscopy with the sensitivity of particle-detection techniques, enabling measurements of rare isotopes produced at rates as low as a few ions per second. The beamline was designed, built, and installed, and was successfully commissioned at FRIB during the grant period. RISE is now a permanent capability of the FRIB facility, and has produced several results on the study of rare atoms and molecules for nuclear structure and fundamental symmetries. In parallel with the FRIB program, the project contributed to the first precision laser-spectroscopy measurements of short-lived radioactive molecules. Working with international collaborators at CERN's ISOLDE facility, the team conducted pioneering experiments on radium monofluoride (RaF) and actinium monofluoride (AcF). The results from this work have been published in major journals of science, including Nature, Science, Nature Physics, Nature Communications, and Physical Review Letters. These findings have guided future experiments on the laser cooling of radioactive molecules, opening a new platform for precision tests of fundamental symmetries.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MAX phase materials and MXenes as hydrogen barrier coatings

Hydrogen and its isotopes play an important role in nuclear applications, but their permeation and radioactivity lead to degradation of materials. Therefore, hydrogen isotope permeation barriers are an important supporting technology. Unfortunately, most permeation barriers that perform well in the laboratory fail when placed in radiation environments. The goal of this work is to begin the development of next generation permeation barriers with materials known to have good stability under neutron irradiation, and then tailor their composition and structure to maximize their barrier properties. In particular MAX phase materials and their two-dimensional analogues (MXenes) have been chosen due their excellent stability under neutron irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Superradiant Neutrino Lasers from Radioactive Condensates

Superradiance emerges from collective spontaneous emission in optically pumped gases, and is characterized by photon emission enhancements of up to $\frac{1}{4}$⁢𝑁 2 in an 𝑁 atom system. The gain mechanism derives from correlations developed within the decay medium rather than from stimulated emission as in lasing, so an analog of this process should be possible for fermionic final states. We introduce here the concept of superradiant neutrino emission from a radioactive Bose Einstein condensate, which can form the basis for a superradiant neutrino laser. A plausible experimental realization based on a condensate of electron-capture isotope 83 Rb could exhibit effective radioactive decay rates accelerated from 86.2 days to minutes in viably sized rubidium condensates of 10 6 atoms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of a Bulk 237 Np Oxide Sample for Trace Actinides

A neptunium oxide sample was dissolved and trace actinide constituents were measured by isotope dilution ICP-MS (for 239–244 Pu, 233–238 U, 237 Np, 241–243 Am) and alpha spectrometry ( 238 Pu, 242 Cm, 244 Cm). This material contained significant quantities of transuranic elements, notably americium and curium. The isotopic composition of the material will continue to evolve over time due to radioactive decay; the measurements reported here include all isotopes decay corrected to a reference date of 1/1/2022. These factors may be considerations in criticality studies of the related 237 Np sphere.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Actinides and Neutron Scattering at the Spallation Neutron Source and High Flux Isotope Reactor

The importance of actinides for science, technology, and medicine is widely recognized and does not require a lengthy introduction. However, the fundamental understanding of actinides and their chemical and physical properties lags behind the knowledge of most other elements in the periodic table. Most actinides (89 ≤ Z ≤ 103) are man-made and were produced in particle accelerators or nuclear reactors in the second half of the 20th century. Although trends in bonding and electronic structure are well characterized and documented across the periodic table, fundamental questions remain regarding the chemistry and physics of the actinides. This lack of knowledge is largely because most isotopes of actinides are intensely radioactive, which greatly increases the difficultly in handling them.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Helical Closure for Radioactive Material Shipping Packages

Radioactive Material (RAM) Packagings Used to transport radioactive material • Weapons components • Medical isotopes • Spent nuclear fuel • Etc. • Packages must adhere to 10 CFR 71 which drive to NUREGs, ASME codes, etc. • Transport Index (A2 values) determine if a package is Type A, Type AF, Type B, Type B(U)F

Housley, William M. [Savannah River National Labor↗

Composition Effects on Kilonova Spectra and Light Curves. I

The merger of neutron star binaries is believed to eject a wide range of heavy elements into the universe. By observing the emission from this ejecta, scientists can probe the ejecta properties (mass, velocity, and composition distributions). The emission (a.k.a. kilonova) is powered by the radioactive decay of the heavy isotopes produced in the merger and this emission is reprocessed by atomic opacities to optical and infrared wavelengths. Understanding the ejecta properties requires calculating the dependence of this emission on these opacities. The strong lines in the optical and infrared in lanthanide opacities have been shown to significantly alter the light curves and spectra in these wavelength bands, arguing that the emission in these wavelengths can probe the composition of this ejecta. In this work, we study variations in the kilonova emission by varying individual lanthanide (and the actinide uranium) concentrations in the ejecta. The broad forest of lanthanide lines makes it difficult to determine the exact fraction of individual lanthanides. Nd is an exception. Its opacities above 1 μm are higher than other lanthanides and observations of kilonovae can potentially probe increased abundances of Nd. Similarly, at early times when the ejecta is still hot (first day), the U opacity is strong in the 0.2–1 μm wavelength range and kilonova observations may also be able to constrain these abundances.

79 ASTRONOMY AND ASTROPHYSICS↗

Proven Technologies for the Solidification of Complex Liquid Radioactive Waste (LRW): Global Case Studies of Applications and Disposal Options - 20424

Legacy radioactive waste streams from the Cold War still exist and newly generated waste streams from nuclear power plants and research institutes go untreated and expose environmental hazards at many nuclear sites. The nature of the waste is diverse, depending upon the source or the process from which it originated. The most problematic waste streams include complex liquids such as organic (tri-butyl-phosphate TBP) solutions contaminated with Pu and U isotopes, mixed sludge types, high acid radioactive waste, H-3 contaminated organic and aqueous streams, etc. Technological, environmental and economic challenges exist for the treatment and disposal of such waste streams. A proven technology that has been applied to LRW on a global basis provides one option as a low-cost solution to legacy streams and small volume, highly complex LRW frequently found during decommissioning at nuclear power plants and weapons sites. The engineered polymer technology from Nochar, USA, is capable of solidifying standard and highly complex LLW and ILW waste streams for interim or final storage, or for incineration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comprehensive Review of Selected Major Categories of Lithium Isotope Separation Techniques

The ability to generate materials with an enriched isotopic abundance, that is one that differs from natural abundance, is critical in terms of technology. Isotopes are used in a wide range of applications, including radioactive tracers, nondestructive tests, radiotherapy in human medicine, nuclear fuels, and isotope‐substituted compounds for chemistry and biology research, as well as environmental geochemical signature tracers. A commonly discussed research topic is the isotopic separation of various elements—uranium, hydrogen, lithium, and iodine, among many others. Among these isotopes, lithium isotopes are especially important in various applications including strategic areas. These isotopes are light and hence their separation techniques are not very obvious. Herein, all the main categories of Li isotope separation are reviewed in depth with a focus on electrochemical technologies for stable lithium isotope separation.

Murali, Arun↗

Experiments with a prototype titanium hot cavity surface ionization source intended for electromagnetic separation of radioactive samarium and other lanthanide elements

This paper reports experimental results of a prototype titanium surface ionization source. For the first time, a lanthanide ion beam has been produced with a surface ionizer composed completely of titanium metal. Titanium does not readily activate with neutron irradiation. This offers the potential for inserting an ion source made of titanium directly into a reactor with a pre-loaded non-radioactive lanthanide target. This seamlessly integrates target irradiation with isotope separation, eliminating post irradiation sample manipulation. Samarium ion beam currents up to 960 nA have been produced in an off-line test bench equipped with rudimentary beam optics. This is a crucial step toward the development of an ionization source adopted for the electromagnetic isotope separator (EMIS) facility, which has been designed for high throughput separations of radioactive 153 Sm and other lanthanides of interest in the field of nuclear medicine. The ion current and important factors affecting the performance of the ion source, such as the ionizer temperature and thermal gradient, are discussed. Lastly, the experimental results are presented together with a discussion of future modifications to optimize the overall surface ionization source performance.

07 ISOTOPE AND RADIATION SOURCES↗

Separation of Lanthanide Isotopes from Mixed Fission Product Samples

The measurement of radioactive fission products from nuclear events has important implications for nuclear data production, environmental monitoring, and nuclear forensics. In a previous paper, the authors reported the optimization of an intra-group lanthanide separation using LN extraction resin from Eichrom Technologies®, Inc. and a nitric acid gradient. In this work, the method was demonstrated for the separation and quantification of multiple short-lived fission product lanthanide isotopes from a fission product sample produced from the thermal irradiation of highly enriched uranium. The separations were performed in parallel in quadruplicate with reproducible results and high decontamination factors for 153 Sm, 156 Eu, and 161 Tb. Based on the results obtained here, the fission yields for 144 Ce, 153 Sm, 156 Eu, and 161 Tb are consistent with published fission yields. This work demonstrates the effectiveness of the separations for the intended application of short-lived lanthanide fission product analysis requiring high decontamination factors.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)↗

Selenium interaction with iron minerals: Quantitative comparison of sorption and coprecipitation impacts on mobility

Given the significance of selenium (Se) as a micronutrient, the radioactive nature of some of its isotopes, and its affinity to iron (Fe) minerals, extensive research has been conducted on the sorption mechanisms between Se and these minerals. Here, in this study, we employ sorption data sourced from the L-SCIE database and coprecipitation data from available literature to achieve the following objectives: i) establish coherence between adsorption and coprecipitation processes, ii) quantitatively evaluate the importance of these processes in nuclear waste repository science, and iii) propose a forward-looking approach for integrating coprecipitation into reactive transport models. Our findings indicate that a correlation between Se adsorption and coprecipitation can be established using the λ formalism. The comparable log(λ Se(IV) /λ Se(VI) ) ratios derived from adsorption and coprecipitation experiments suggest that these processes can be quantitatively compared and evaluated using our numerical approach. Across all iron oxide phases examined, coprecipitation leads to significantly greater immobilization of Se compared to adsorption. Specifically, for hydrous ferric oxide, hematite, and goethite, coprecipitation is predicted to result in 100–1000 times more Se immobilization compared to adsorption, irrespective of the Se oxidation state (Se(IV) or Se(VI)); notably stronger immobilization potential via coprecipitation was observed for magnetite. The modeling approach and quantitative analysis presented herein clearly highlight the importance of including coprecipitation processes when simulating Se (and other elements) transport, particularly under conditions where mineral compositions are transient or evolving with time. Neglecting coprecipitation in models is likely to lead to significant overestimates of migration.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗