Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE WASTE STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of a Conditioned System-Level Groundwater Model to Evaluate Long-Term Groundwater Impacts within a Performance Assessment - 20115

A preliminary performance assessment (PA) of single-shell tank Waste Management Area (WMA) A-AX located at the U.S. Department of Energy (DOE)'s Hanford Site in southeastern Washington is being conducted to satisfy the requirements of DOE Order 435.1 [1] as it relates to closure of the single-shell radioactive waste tanks in the WMA A-AX tank farms. A PA assesses the fate, transport, and impacts of radionuclides within a low-level radioactive waste disposal facility in its assumed closure configuration and the subsequent potential doses to humans over a 1,000-year compliance period and a 10,000-year performance evaluation period. The WMA A-AX preliminary PA evaluation is structured around the complementary use of process-level and system-level models to calculate the facility performance against established DOE Order 435.1 [1] performance objectives. Process-level models are those that represent a detailed phenomenological representation of processes of concern in the PA. Process models typically only represent one or a few of the components of the PA, such as groundwater flow and transport, and must be integrated with other modeling elements to perform PA calculations. System-level models are those that are abstracted from the process models, retaining the essential features of the process model, while allowing integration of all aspects of the PA in a single modeling framework. System-level models are often characterized by coarser numerical discretization, lower dimensionality, or other similar simplifications compared to the process-level model. Traditionally, a three-dimensional (3-D) process-level model is utilized primarily to evaluate the long-term impact on groundwater and the potential doses to individuals who consume contaminated groundwater. System-level models are also utilized to evaluate the groundwater pathway in PAs. These models typically have reduced dimensionality (1-D) and are conditioned utilizing flow fields (Darcy fluxes) and moisture content distributions that are abstracted from the process level models. The abstraction approach assures that the flow field in both models is consistent for a specific set of input parameters for flow, differing only in the discretization and dimensionality of the two models. The preliminary WMA A-AX PA incorporates a detailed representation of the geological system and hydraulic properties within the 3-D model STOMP{sup C} numerical code so that the effects of relevant features and processes on water flow and radionuclide transport in the subsurface can be evaluated. The complementary system-level model is developed utilizing the GoldSim{sup C} code to implement a simplified, 1-D equivalent model to represent the groundwater pathway. Contaminant transport through the vadose zone and unconfined aquifer for Tc-99 and I-129 were evaluated in each of the models. Adjustments to the saturated portion of the GoldSim{sup C} 1-D model were required to mimic the dispersion effect captured with the 3-D STOMP{sup C} model. Once this conditioning was conducted, highly similar results for the transport of Tc-99 and I-129 were achieved at the point of calculation, located 100 m downgradient from the WMA A-AX fenceline. These radionuclides represent elements that are regarded as primary dose drivers in the PA groundwater pathway analysis. The high degree of conformance between the two models suggests that the use of the equivalent 1-D system model is suitable for evaluating the full suite of radionuclides that will be released from the tank sources within WMA A-AX over the 1,000-year compliance period and over the 10,000-year evaluation period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colloidal Behavior of Plutonium Oxide in Concentrated Electrolyte Solutions

The Hanford Site in Washington State manages legacy high-level radioactive waste streams that display major chemistry and engineering challenges, including the high salt levels and pH values that correspond to conditions under which many classical concepts describing chemical reactivity cannot be applied. One particular challenge that needs to be tackled at Hanford is that Pu concentrations, [Pu], in the soluble phases of the tank wastes are higher than expected based on the solubility of crystalline PuO2, which is widely accepted to be caused by the formation of PuO2 colloid, consisting of nano- to submicron-sized particles (PuO2 NPs). Fundamental research underpinning the behavior of PuO2 NPs under conditions not only relevant to the Hanford tank waste but at high ionic strength in general is needed to reliably predict the chemical reactivity of PuO2 NPs and develop engineering solutions to safely and efficiently process high-level radioactive waste into forms suitable for long-term storage. In this work, we study the behavior of PuO2 NPs (particle size ~100 nm) under high ionic strength conditions by reacting it with highly concentrated (up to 5 M) salt solutions. We explore different electrolyte compositions to elucidate the impact of different anions (NO3-, Cl-, ClO4-, SO42-, C2O42-, CO32-) on the stability of PuO2 NP in the acidic and alkaline pH regime. PuO2 NP aggregation and precipitation as function electrolyte concentration is tracked by a combination of liquid scintillation counting, dynamic light scattering for determination of particle size distributions, and zeta potentials as a proxy for particle charge. At acidic pH, electrolytes containing non-coordinating anions, such as NaNO3, NaCl, and NaClO4 mostly stabilize PuO2 NPs over a large electrolyte concentration range, showing only subtle differences in their reactivity. Other electrolyte anions show a more pronounced effect on the PuO2 NP stability: SO42-, binds directly to the particles’ surface, reverses the particle charge, and precipitates the PuO2 NPs efficiently even at intermediate sulfate concentrations (>0.1 M). In contrast, C2O42- is found to lead to high [Pu] in solution, in the milli-molar range, even at mildly acidic pH (~4). Thermodynamic modeling of the dissolved Pu concentrations using PHREEQC is unable to predict the observed [Pu] in the acidic pH regime, supporting the influence of colloids in maintaining elevated [Pu]. It is noteworthy that the current thermodynamic databases do not include constants for colloidal Pu phases and cannot accurately predict many of the high ionic strength solutions relevant to this work. The mechanisms and models responsible for these observations will need further investigation in the future. At high pH values (~12), PuO2 NPs exhibits classical sol-gel chemistry, meaning that upon destabilization of the colloidal sol, for example by addition of concentrated NaOH, highly porous and viscid PuO2 coagulates are formed that consist of a three-dimensional network likely held together by physical interactions. The PuO2 NP coagulate shows no significant reversibility of the aggregation when contacted with concentrated brines; however, PuO2 NPs can be efficiently resuspended in solution by addition of diluted electrolytes, alkaline solutions containing high amounts of carbonate, or simple addition of water. Especially carbonate is shown to stabilize PuO2 NPs in solution at high pH, characterized by stable colloidal suspensions that are resistant against sedimentation during centrifugation. Thermodynamic modeling of the carbonate system was able to predict an increasing dissolved Pu concentration with increasing carbonate concentration. However, the model was profoundly sensitive to the fixed redox potential and does not include any thermodynamic constants for colloidal Pu species.

Neumann, Julia↗

Experiences with Mobile Units for Liquid RAW Management in Slovak and Czech Nuclear Power Plants - 20089

In Nuclear Power Plants VVER 440, Russian type of reactor there was designed auxiliary building where according to basic design all operational liquid radioactive waste (RAW) should be stored in large capacity tanks during the whole operational period. That's why there are in the auxiliary building several types of large storage tanks with different internal volume from 110 m{sup 3}, 460 m{sup 3} to 550 m{sup 3}. Storage tanks are usually situated in rooms with limited access and minimal handling space. Operational waste was here transported by the system of pipes from the reactor building. There is possibility to handle with the waste and set the pipeline in to the chosen storage tanks. Nobody takes care about the quality of waste in the storage tanks and waste waits for the period of decommissioning when it should be treated. The storage capacity was designed for the whole lifetime of nuclear power plant. Currently the life time of Nuclear Power Plant's (NPP) is extended and there is necessity to retrieve and treat the RAW in advance. Another reason why the stakeholder, who operates the NPPs, decides to treat the operational RAW during the operational period of NPP, is that there are still new requirements from safety point of view which need to have free available space for example because of potential accident. So treating the operational RAW during the life time of NPP is present issue. Because in basic design nobody cares how the RAW will be retrieved and treated in the future, there is usually no technology for that in existing NPP. Some of the NPPs build an additional building with suitable technologies for treatment or hire the company which offer mobile technology for retrieving the waste from the storage tanks. Wood Nuclear Slovakia PLC provides all activities within liquid RAW management projects by its own staff including management, design, construction and deployment of equipment, engineering support, as well as all RAW retrieval and solidification activities. We offer RAW management as a service without any significant changes in existing NPP's buildings and technology. It is always a technical challenge to conduct successful retrieval, pumping and treatment of RAW. The complex RAW retrieval system can be designed as tailored solution for any RAW storage according to known boundary conditions and specific needs. These systems are based on years of experience with RAW manipulation, processing and treatment and the whole RAW management knowledge by Wood Nuclear Slovakia LTD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cerium oxide impact on fresh and hardened properties of cementitious materials

Cements used in global nuclear waste treatment, storage, and disposal require thorough testing of fresh and cured properties to demonstrate regulatory compliance. Using actual radioactive wastes is often cost-prohibitive during early scoping tests necessitating the use of non-radiological surrogates. Cerium (Ce) is often used as a surrogate for actinides uranium (U) and plutonium (Pu) in spent nuclear fuel, yet few studies have explored how Ce impacts the properties used to qualify a cement for use. Here, this work compares the fresh and cured properties of three classes of cements – ordinary portland cements, ultra-high performance cement composites, and magnesium phosphate cements – each with and without ceria (CeO 2 ). Due to CeO 2 sorption of water (54 vol%) that effectively decreases the water available to hydrate and form binding cement phases, variations in key cement properties were detected that suggest surrogate CeO 2 –cementitious matrices may not be representative of matrix behaviors when using U and Pu sources.

36 MATERIALS SCIENCE↗

Project Report for Cold Spray: Phase 2

In support of the ongoing environmental protection mission at the Hanford Site, led by Washington River Protection Services (WRPS), the cold spray team has continued development of the tank refurbishment technology. Orano Federal Services, along with subcontractors VRC Metal Systems (VRC) and Robotic Technologies of Tennessee (RTT), have worked with WRPS experts to refine the tools demonstrated in Phase 1 of this project, with the potential to refurbish double shell tanks (DST)s on the Hanford Site, extending the service lives of these vital waste storage facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance-based simulants for Hanford radioactive waste treatment process testing

Radioactive wastes from nuclear fuel processing are stored in large underground storage tanks at the Hanford Nuclear Reservation. Treatment and remediation require that waste feed from the storage tanks be delivered to the Hanford Tank Waste Treatment and Immobilization Plant continually for the duration of the treatment mission. Furthermore, the complex physical and chemical processes required for this mission, the significant scale, and the hazardous nature of the waste necessitate the use of simulants in process testing. A new class of simulants, “performance-based simulants,” has been developed to match the process performance of the simulant to actual waste performance data.

Hanford tank waste treatment↗

Epoxy Sealant Self-leveling and Adhesion Test Report

The Hanford tank farms have 149 single shell tanks which were built between 1943 - 1964, and 28 double-shell tanks (DSTs) which were built between 1968 – 1986 (Tank Farms, 2020) which contain radioactive and chemical mixed waste. Many of the tanks have leaked, including DST AY-102 (Waste Tank Summary Report, 2023). As a result, methods of repairing or reinforcing double-shell storage tanks are being evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks – 25213

The Hanford Nuclear Reservation site contains approximately 211 million liters of radioactive and chemically hazardous waste arising from nuclear weapons production, beginning with World War II, and continuing through the Cold War [1]. The waste is stored in 177 carbon-steel underground storage tanks, of which 149 are single-shell tanks (SSTs) and the remaining are double-shell tanks (DSTs). The mission of an ongoing River Protection Project is to retrieve the waste from the underground storage tanks and then treat and immobilize (i.e., vitrify) it for disposal. Waste from the older SSTs is being progressively retrieved into the newer DSTs for storage pending treatment, immobilization, and disposal. Figure 1 depicts a typical DST design [2]. The tank is approximately 23 m in diameter and 9 m high and has a domed structure and has a capacity of 4000 m3. The tank wall and floor vary in thickness between approximately 10 mm and 25 mm depending on location. The thicker wall sections are near the curved transition between the tank wall and the floor, while the thinner sections are located near the top of the tank wall. The tank floor thickness varies from 25 mm at the tank center to 10 mm near the tank wall. The tanks were constructed of either ASTM A516 Grade 65 or ASTM A537 Class 1 carbon steel and were post-weld heat treated to reduce the risk of SCC.

Shukla, Pavan K. [Savannah River National Laborato↗

Spent nuclear fuel receipt rate analysis within an integrated waste management system (IWMS) architecture that includes consolidated storage

A key parameter in analyzing the performance of an integrated waste management system (IWMS) architecture for the disposition of spent nuclear fuel (SNF) is the SNF receipt rate from reactor and other custodian sites. Receipt rate in this paper means how much SNF is accepted per year for transport in the IWMS from such sites. Introducing one or more federal consolidated interim storage facilities (CISFs) into the IWMS architecture can potentially accelerate the receipt rate profile over time relative to system architectures without a CISF. This raises the question of what an optimal SNF receipt rate profile for an IWMS architecture might be in view of practical constraints and desired system performance attributes and associated metrics. This paper describes a sensitivity study on SNF receipt rates and the associated results for a selected set of IWMS scenarios aimed at informing near-term planning for interim storage capabilities and transportation assets. Two different strategies for CISF operation while awaiting availability of a disposal system to receive SNF are compared: one that relatively quickly fills an initial CISF and then idles the transportation system; and another that aims for more continuous use of transportation assets and receipt capabilities at the CISF. This study examines cost considerations and other factors, such as the timing of clearing reactor sites of SNF, efficient use of capital assets, and some other metrics that might be important to a CISF host community. Based on the analysis, an initial approach is presented that targets a continuous receipt strategy while maintaining the flexibility to step up receipt capabilities to a reasonable degree when needed and beneficial, within overall system constraints.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Default Radioactive and Hazardous Waste Management (RHWM) Dose Conversion Factors (DCFs) and Weighting Factors and plutonium-239 equivalent Curie (PE-Ci) methodology for acceptance into the Waste Storage Facilities

DOE-STD-5506-2007 (Ref. 1) is the standard that provides the methodology for preparing hazard analysis and accident analysis for transuranic (TRU) waste facilities. The Waste Storage Facilities hazard and accident analysis for the DSA is developed in accordance with DOE-STD- 5506-2007. Two related issues need to be addressed when implementing DOE-STD-5506-2007 regarding the calculation of consequences from TRU waste releases in accident analysis: Consequences determined in accident analysis must be modeled using inhalation Dose Conversion Factors (DCFs) that are consistent with those from the International Commission on Radiological Protection Publication 72 (ICRP-72, Ref. 2).; The use of a statistical Material at Risk (MAR) representing the distribution of radiological loading of TRU waste containers based on the use of a plutonium-239 equivalent Curie (PE-Ci) methodology. The PE-Ci methodology simplifies accident analysis by allowing one to model releases based on the Curie value of one standard nuclide (e.g., Pu-239) instead of needing to model releases for every potential nuclide of interest. This is accomplished by normalizing the Curie value of all nuclides to a single Curie value of a standard nuclide by using a Weighting Factor that is a ratio of the DCFs associated with the nuclides and that of the standard nuclide. By using the ICRP-72 DCFs to calculate PE-Ci values used in the statistical MAR, the accident analysis that uses that statistical MAR will be consistent with the consequence methodology identified in DOE-STD- 5506-2007.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A risk-informed assessment tool to support review of license amendment requests for spent nuclear fuel dry cask storage systems

We report that while risk-informed safety evaluations are common methodologies used by the U.S. Nuclear Regulatory Commission (NRC), their application in the field of commercial spent nuclear fuel (SNF) dry storage has received limited attention. For instance, license amendment requests (LARs) for SNF dry cask storage systems (DCSSs) are evaluated according to U.S. NRC standard review plans (SRPs). However, risk-informed LAR review strategies could improve the understanding of critical system modifications, and lead to more predictable, efficient, and consistent LAR review processes. A methodology to develop a risk-informed LAR review tool is presented. Although focused on DCSSs, this methodology can be used to develop similar tools for a broad spectrum of safety-relevant systems. The end product (i.e., the tool) includes a tree diagram to help visualize the review risk significances assigned to a predefined set of system modifications and supporting rationale documentation. Instructions support correct tool application and provide the user with a path to incorporate currently unevaluated modifications in the tool structure. The demonstration of the methodology leads to the conclusion that risk-informed reviews of DCSS LARs are possible, although the tool precision could benefit from additional risk information. Further, the results indicate that many typical LARs involve low-risk or medium-risk modifications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 88: Waste Management from Remediation of Legacy Sites or Unplanned Releases

This panel focused on the progression of cleanup on the Hanford Site, Washington, USA, from establishing the regulatory framework necessary for cleanup, to understanding the risks and addressing near-term hazards, to moving to 24/7 operations as cleanup focuses on tank waste treatment and co-located risk reduction efforts as the active cleanup footprint shrinks. Panelists with presentations: Hanford: Past, Present, Future (Brian Vance); Protecting the River (L. Ty Blackford); Hanford Tank Farms (John Eschenberg Jr.); The Hanford Site (Robert Wilkinson); The Hanford Site (Valerie McCain)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated Aging and Evaluation of Hose-In-Hose Transfer Lines in the Hanford Waste Transfer System - 20312

Nonmetallic materials are used in the United States Department of Energy's Hanford Site Tank Farm waste transfer system. These materials include the inner primary hoses in the hose-in-hose transfer lines (HIHTLs), Garlock{sup R} gaskets, ethylene propylene diene monomer (EPDM) O-rings, and other nonmetallic materials. These nonmetallic materials are exposed to β and γ radiation, caustic solutions as well as high temperature and pressure stressors. How the nonmetallic components react to each of these stressors individually has been well established. However, simultaneous exposure of these stressors has not been evaluated and is of great concern to Hanford Site engineers. Florida International University's Applied Research Center engineers worked closely with key Hanford's Washington River Protection Solutions personnel to develop an experimental test plan that determines how these nonmetallic components react to various simultaneous stressor exposures. In this paper, research on the experimental testing of the hose-in-hose transfer lines used in the Hanford tank farm waste transfer system under simultaneous stressor exposures is presented. The stressor exposure experiments consisted of various combinations of simultaneous stressor exposure of caustic solution, high temperature and high pressure stressors. Research efforts focused on evaluating the aging behavior of EPDM by exposing samples of HIHTLs as well as EPDM dog bone shaped specimens to a 25% NaOH solution at (38 deg. C), operating (54 deg. C) and design temperatures (77 deg. C) for 6 months and 12 months. In addition, HIHTL and the EPDM dog-bone specimens were exposed to only hot water at 77 deg. C for a duration of one year. The mechanical and material properties of the samples were characterized and compared with those of the unexposed samples (baseline). Evaluations included burst pressure tests of the EPDM hose-in-hose transfer lines and material tensile strength test of EPDM dog-bone coupons. Both the tensile strength of the EPDM material dog bones and the burst pressure of the HIHTLs significantly decreased with the increasing temperature and increasing exposure time. When compared with the baseline samples, the burst pressure decreased by 28.75% for the sample aged at 77 deg. C after 12 months, in comparison to sample aged at 38 deg. C and 54 deg. C which had about 1.34% and 5.70% loss in burst pressures, respectively, after 12-month exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Parallel Process Execution in the Next Generation System Analysis Model

As of the end of 2021, 88,880 metric tons of heavy metal (MTHM) (44,741 MTHM in dry storage; 44,139 MTHM in wet storage) of spent nuclear fuel (SNF) were stored at various reactor sites across the United States [1]. The Office of Storage and Transportation in the Department of Energy is planning for the transportation, storage, and eventual disposal of SNF and high-level radioactive waste (HLW). To aid in this effort and inform decision-makers about the backend of the spent fuel cycle, systems analysis tools capable of analyzing the various options with respect to SNF and HLW management are being used as well as continuously improved to meet the evolving needs of the program. System analysts typically use these tools to vary underlying assumptions (shipping rates, allocation priority, available facilities, start dates, etc.) and study the implications of these changes on site clearance schedules, campaign costs, transportation infrastructure acquisition, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗