Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency doubled Alexandrite laser wavelengths in cesium vapor

This work focused on understanding the effects of arbitrary transverse and longitudinal relaxation rates on the susceptibilities of coherently driven three-level systems. The approximation of a single relaxation rate often made in previous work is strongly invalidated by the variation in the spontaneous emission lifetime between various atomic level pairs in systems such as cesium. It is of great importance to the problem of nonlinear infrared generation to determine the dependence of both real and imaginary susceptibility on relaxation rates. The imaginary susceptibility on the pump transition determines the absorption of pump photons and the imaginary susceptibility on the laser transition determines the spectral dependence of the gain. This is of particular importance for pure Raman emission (i.e., absorption at linecenter of the gain transition) as it determines the tunability characteristics we are aiming to predict. The real susceptibility is important when cavities are used at the signal field as this will determine the loaded resonance of the Raman oscillator. Researchers show that in some cases which result from having different relaxation rates mode splitting may result, allowing more than one frequency to have the same Raman wavelength, possibly resulting in a temporal instability.

Lawandy, N. M.↗

Spontaneous Raman Scattering Diagnostics: Applications in Practical Combustion Systems

In this chapter, the recent advancements and practical aspects of laser SRS diagnostics have been reviewed wi til regards to applications in practical combustion systems. Clearly, SRS represents a theoretically and experimentally mature diagnostic technology that has become an essential tool for multiscalar measurements in turbulent combustion at elevated pressures. Today, time-, space-, spectrally, and even polarization-resolved S RS diagnostics is at hand, with aid from recent innovations in theoretical and technological developments on electro-optical or electromechanical devices. Whilst a linear increase in SRS signals can be expected in high-pressure systems (this is perhaps one of the most important advantages for using SRS in high-pressure systems), there are practical (often severe) restrictions associated with pressurized vessels, due mainly to the limited degree of optical access. This narrows ti,e available choice of diagnostics that can be employed at any given time. Point-wise SRS diagnostics provides the highest accuracy on the chemical species and temperature measurements, and will continue to remain a vital approach for the study in such harsh environments. The practical design considerations and hands-on set-up guide for SRS diagnostics provided in this chapter are rarely presented elsewhere. Although the second-harmonic Nd:YAG pulsed laser (532 nm), combined with pulse-stretching optics or the recently introduced White Cell-based laser, seems to be the most favored excitation source of choice by the research community, UV excitation will undoubtedly continue to be used on many occasions, and especially in sooting flames. Detection methods may be divided into ICCD-based nanosecond-gate detection or a rotary-chopper electromechanical shutter-based CCD array detection, and the levels of background flame emission in individual cases would determine this critical design choice. Here, a process of Raman signal calibration based on ti,e crosstalk matrix formalism was explained step-by-step. As tI,is process may be very time-consuming and expensive, a well-planned experimental approach (01' building a transferable calibration database or library (at least with in a user's own facility over a series of different testing and runs) is vitally important. Hands on advice on the design and construction of flow control systems for high pressure burner facilities were also presented.

Kojima, Jun↗

Computer program to simulate Raman scattering

A computer program is described for simulating the vibration-rotation and pure rotational spectrum of a combustion system consisting of various diatomic molecules and CO2 as a function of temperature and number density. Two kinds of spectra are generated: a pure rotational spectrum for any mixture of diatomic and linear triatomic molecules, and a vibrational spectrum for diatomic molecules. The program is designed to accept independent rotational and vibrational temperatures for each molecule, as well as number densities.

Zilles, B.↗

Spontaneous Raman scattering as a high resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a cw hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated.

Rothenberg, J. E.↗

Spontaneous Raman scattering as a high-resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a CW hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated. Previously announced in STAR as N83-18422

Rothenberg, J. E.↗

Multispecies coherent anti-Stokes Raman scattering instrument for turbulent combustion

A nonintrusive diagnostic system is described which permits simultaneous measurement of temperature, nitrogen number density, and oxygen number density in hostile combustion environments. This system is pumped by a 10-Hz neodymium YAG laser, and signals are detected with an intensified photodiode array and dual photomultipliers. The system utilizes a folded BOXCARS beam arrangement, two probe dye lasers, dynamic range expansion, polarization rejection of nonresonant background, and multiplexing of the signal beams.

Antcliff, Richard R.↗

Third and higher harmonic plasma emission due to Raman scattering

The theory for third and higher harmonic plasma emission by the weak turbulence (or random phase) process L + T prime to T (where L denotes a Langmuir wave, and T and T prime denote transverse waves) is developed. Kinematic constraints on the characteristics and growth lengths of waves participating in the wave processes are identified. The cases of L waves produced either directly by a streaming instability, or by the decay L to L prime + S (S is an ion sound wave) of L waves generated by a streaming instability, are considered. Limits on the brightness temperature of the radiation are determined, and expressions for the growth rate and path-integrated wave temperatures are derived.

Cairns, Iver H.↗

Quantum statistics of Raman scattering model with Stokes mode generation

The model describing three coupled quantum oscillators with decay of Rayleigh mode into the Stokes and vibration (phonon) modes is examined. Due to the Manley-Rowe relations the problem of exact eigenvalues and eigenstates is reduced to the calculation of new orthogonal polynomials defined both by the difference and differential equations. The quantum statistical properties are examined in the case when initially: the Stokes mode is in the vacuum state; the Rayleigh mode is in the number state; and the vibration mode is in the number of or squeezed states. The collapses and revivals are obtained for different initial conditions as well as the change in time the sub-Poisson distribution by the super-Poisson distribution and vice versa.