Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELAP5”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

ECAR-6332 Rev 3 RELAP5-3D Thermal-Hydraulic Analysis of MARVEL Microreactor - Final Design

This document reports the thermal hydraulic analyses results for the MARVEL microreactor, final design, including dry criticality, normal operation, operational transients and a set of very-low probability transients caused by accident conditions. The ultimate scope of this document is to demonstrate the MARVEL microreactor thermal hydraulic performances and its inherent safety. First, the list of the operational and accidental transients with the corresponding acceptance criteria are recalled. Then, details of the final design, the key input parameters, the assumptions, and the methodology used for performing the deterministic safety analyses are presented. Finally, the analyses results are provided, demonstrating the satisfaction of the corresponding acceptance criteria.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The behavior of ANGRA 2 nuclear power plant core for a small break LOCA simulated with RELAP5 code

This work discusses the behavior of Angra 2 nuclear power plant core, for a postulate Loss of Coolant Accident (LOCA) in the primary circuit for Small Break Loss Of Coolant Accident (SBLOCA). A pipe break of the hot leg Emergency Core Cooling System (ECCS) was simulated with RELAP 5 code. The considered rupture area is 380 cm{sup 2}, which represents 100% of the ECCS pipe flow area. Results showed that the cooling is enough to guarantee the integrity of the reactor core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

COUPLING OF RELAP5-SCDAP MOD4.0 AND NEUTRONIC CODES

High-fidelity and accurate nuclear system codes play a key role in the design and analysis of complex nuclear power plants, which consist of multiple subsystems, such as the reactor core (and its fuel, burnable poisons, control elements, etc.), the reactor internal structures, the vessel, and the energy conversion subsystem and beyond to grid demand. Most commonly the interplay between these various subsystems is modeled using coupled codes, each of which represents one of the subsystems. And the most common direct coupling is that of thermal-hydraulics and neutronics codes. The subject of this paper is the coupling of codes that model not only thermal-hydraulics and neutronics, but also structural components damage. Furthermore, the neutronic component is not limited to the sole core solver. The coupled code system encompasses thermal-hydraulics, material performance of the fuel, neutronic solver, and neutronic data preparation. Thus, this paper presents a framework for coupling RELAP5/SCDAPSIM/MOD4.0 with a suite of neutron kinetics codes that includes NESTLE, DRAGON and a version of the ENDF library. The version of the RELAP5/SCDAPSIM/MOD4.0 code used in this work is one developed by Innovate System Software (ISS) as part of the international SCDAP Development and Training Program (SDTP) for best-estimate analysis to model reactor transients including severe accident phenomena. This RELAP5/SCDAPSIM/MOD4.0 code version is also capable of predicting nuclear fuel performance. It uses nodal power distributions to calculate mechanical and thermal parameters such as heat-up, oxidation and meltdown of fuel rods and control rods, the ballooning and rupture of fuel rod cladding, the release of fission products from fuel rods, and the disintegration of fuel rods into porous debris and molten material. On the neutronics side, this work uses the NESTLE and DRAGON codes. NESTLE is a multi-dimensional static and kinetic neutronic code developed at North Carolina State University. It solves up to four energy groups neutron diffusion equations utilizing the Nodal Expansion Method (NEM) in Cartesian or hexagonal geometry. The DRAGON code, developed at Ecole Polytechnique de Montreal, performs lattice physics calculations based on the neutron transport equation and is capable of using very fine energy group structures. In this work, we have developed a coupling approach to exchange data among the various modules. In the coupling process, the generated nuclear data (in fine multigroup energy structure) are collapsed down into two- or four-group energy structures for use in NESTLE. The neutron kinetics and thermal-hydraulics modules are coupled at each time step by using the cross-section data. The power distribution results of the neutronic calculations are transmitted to the thermal-hydraulics code. The spatial distribution of coolant density and the fuel-moderator temperature, which result from the thermal-hydraulic calculations, are transmitted back to the neutron kinetics codes and then the loop is closed using new neutronics results. Details of the actual data transfers will be described in the full length paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systems Engineering (SE) Approach of Developing A Passive Safety Injection System (PSIS) to Cope with APR1400 Extended Station Black-Out (SBO) Accident Using RELAP5

On 11 March 2011 the power supply and cooling of the three Fukushima Daiichi reactors were disabled by a major earthquake followed by a relatively high tsunami waves. The earthquake damaged the electrical grid which is the normal power supply for the reactors, then the tsunami waves disabled the emergency diesel generators of the Fukushima Daiichi reactors, which left the plant with no alternating current (AC) source. This condition is called 'Station Black-Out'. The reactors were tripped immediately, but due to the nuclear physics phenomena, the reactor cores were still producing thermal power, which is generated by the decay of radioactive fission products in the reactor core, known as decay heat. The decay heat had not been circulated to an external heat sink and eventually the accumulative heat produced in the core led to damage to the reactor cores. After the Fukushima Daiichi accident, Design Extension Condition (DEC) such as total loss of feed water (TLOFW), and prolonged Station Black-Out (SBO) attracted the attention of nuclear experts. The attention focuses on the defense in depth concept, redundancy and sustainability of the systems, and development of the passive safety systems, which rely on natural physics laws. The topic of this paper is to discuss the possibility of attaching a Passive Safety Injection System (PSIS) to the APR1400. The PSIS is a safety system which provides adequate cooling water to the steam generators after the loss of the Auxiliary Feed Water System (AFWS) during an extended SBO accident. The PSIS will be available while the power supply of the plant is being recovered and the active safety systems take over the functionality. The anticipated PSIS will be automatically actuated to enhance the engineered safety feature and to reduce the human errors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity study of PWR upper vessel flow and phenomena using RELAP5-3D

During normal pressurized water reactor (PWR) operation, water enters the reactor pressure vessel (RPV) from the cold leg and exits through the hot leg. While most of this water flows through the downcomer and reactor core, a number of other flow paths exist, including the core baffle/bypass and the upper plenum spray. The upper plenum sprays normally account for a small fraction (less than 10%) of the total inlet flow, and provide cooling to the upper vessel dome and instrumentation/control rod channels. In the event of a loss-of-coolant accident (LOCA), especially one with core blockage, this alternative flow path may play a key role in maintaining core coolability. Because of the possible safety implications of the upper vessel flow, it is important to ensure the models used to simulate this region of the vessel are accurate. In this study, the model was altered to better reflect the internal flow path of the upper head and this was compared to the reference model. The simulation of interest is a hot leg double-ended guillotine (HL DEG) break followed later by a full blockage of the core and core bypass. In this scenario, the coolant can only reach the core through the upper spray bypass, so its impact on core coolability can be clearly seen. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Modeling of the OECD-NEA HTTF Benchmark

HTTF at Oregon State University (OSU) Reference: General Atomics’ modular high-temperature gas-cooled reactor Helium cooled, electrically heated (2.2 MW) Prismatic graphite blocks in the core and reflectors Alumina ceramic blocks are used to simulate the core and top and bottom reflectors One-fourth scale in length and diameter Most of the coolant channels in the core are full scale Lower pressure compared to the prototype reactor (0.7 MPa) Over 500 instruments Designed primarily to investigate depressurized (DCC) and pressurized (PCC) conduction cooldown transients

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗