Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESEARCH EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Hydrogen Equipment Enclosure Risk Reduction through Earlier Detection of Component Failures

Hydrogen component reliability and the hazard associated with failure rates is a critical area of research for the successful implementation and growth of hydrogen technology across the globe. The research team has partnered to quantify system risk reduction through earlier detection of hydrogen component failures. A model of hydrogen dispersion in a hydrogen equipment enclosure has been developed utilizing experimentally quantified hydrogen component leak rates as inputs. This model provides insight into the impact of hydrogen safety sensors and ventilation on the flammable mass within a hydrogen equipment enclosure. This model also demonstrates the change in safety sensor response time due to detector placement under various leak scenarios. The team looks to improve overall hydrogen system safety through an improved understanding of hydrogen component reliability and risk mitigation methods. This collaboration fits under the work program of IEA Hydrogen Task 43 Subtask E Hydrogen System Safety.

CFD↗

Intelligent Manufacturing Support: Specialized LLMs for Composite Material Processing and Equipment Operation

Engineering educational curriculum and standards cover many material and manufacturing options. However, engineers and designers are often unfamiliar with certain composite materials or manufacturing techniques. Large language models (LLMs) could potentially bridge the gap. Their capacity to store and retrieve data from large databases provides them with a breadth of knowledge across disciplines. However, their generalized knowledge base can lack targeted, industry-specific knowledge. To this end, we present two LLM-based applications based on the GPT-4 architecture: (1) The Composites Guide: a system that provides expert knowledge on composites material and connects users with research and industry professionals who can provide additional support and (2) The Equipment Assistant: a system that provides guidance for manufacturing tool operation and material characterization. By combining the knowledge of general AI models with industry-specific knowledge, both applications are intended to provide more meaningful information for engineers. In this paper, we discuss the development of the applications and evaluate it through a benchmark and two informal user studies. The benchmark analysis uses the Rouge and Bertscore metrics to evaluate our models’ performance against GPT-4o. The results show that GPT-4o and the proposed models perform similarly or better on the ROUGE and BERTScore metrics. The two user studies supplement this quantitative evaluation by asking experts to provide qualitative and open-ended feedback about our model’s performance on a set of domain-specific questions. The results of both studies highlight a potential for more detailed and specific responses with the Composites Guide and the Equipment Assistant.

Kapoor, Gunnika [Oak Ridge National Laboratory (OR↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

A practical guide for crystal growth of van der Waals layered materials

This Tutorial provides an overview of the techniques that are most commonly utilized to grow bulk van der Waals crystals. The materials discussed were selected to highlight various challenges that are often encountered during crystal growth. Additionally, in relatively equal parts, the text covers melt-based techniques, vapor transport growths, and the characterization of crystal quality with an emphasis on structural and chemical homogeneities. Furthermore, pertinent details are given regarding the growth and characterization of many specific compounds, with examples mostly drawn from our own research, and an effort is made to highlight cases where the growths offer a particular lesson or the conditions have a significant impact on the crystal’s physical properties. A primary goal is to motivate more researchers to grow crystals by providing general descriptions and considerations for different growth techniques and equipment while sharing some of our own lessons learned and best practices for the growth and characterization of layered van der Waals crystals. The Tutorial is not written solely for aspiring crystal growers, however, because any researcher who collaborates with a crystal grower can benefit from having a greater understanding and appreciation of the processes of crystal growth and materials development.

36 MATERIALS SCIENCE↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Carbon Dioxide Utilization Life Cycle Analysis Guidance for the U.S. DOE Office of Fossil Energy and Carbon Management (Version 2.0)

Capturing carbon dioxide (CO 2 ) and placing it in permanent storage in geologic formations is an option for reducing CO 2 emissions, but it may not be a viable one for all CO 2 emitters. For some, the added cost of capture may be too high to implement, or the geology near the source may not be suitable for storage. In these circumstances, other options will be needed. Carbon use and reuse, or CO 2 utilization (CO2U), is an alternative approach that seeks beneficial uses for captured CO 2 , such as using it as a feedstock in the production of fuels, chemicals, and building materials. These uses would give CO 2 value that could be used by suppliers (emitters) to offset capture costs. One of the principal features and challenges associated with CO2U is that the products derived from CO 2 must have lower carbon footprints than their conventional counterparts. Previous assessments of CO2U alternatives have focused on the carbon content of utilization products as an indicator of CO 2 equivalent (CO 2 e) emissions reduction potential. However, embodied emissions are—at best—only weakly correlated with the amount of carbon contained in any physical product. Therefore, the most attractive CO2U options will both displace the carbon in an existing product and improve the overall carbon efficiency of the manufacturing process. Research to overcome barriers will include identifying existing co-feeds and available low-carbon energy sources to enable the conversion of CO 2 to value-added products under favorable processing conditions. New discoveries in the fields of nano- and bio-technology will be applied to efficiently utilize CO 2 in new applications. Development of advanced materials and processes, integrating CO 2 capture with utilization processes (e.g., algae), exploring a diverse slate of products from CO 2 to effectively offset capture costs and developing processes based on waste energy are means to overcome these barriers. The research will lead to the development of advanced catalysts, materials, and equipment that can be used to convert CO 2 into useful products. The result will be multiple flexible and adaptable technology platforms that can be used to produce suites of products spanning multiple utilization pathways.

54 ENVIRONMENTAL SCIENCES↗

Inchfab – A ultra-low-cost micro and nanofabrication platform (CRADA Final Report)

Inchfab Inc. is developing an ultra-low cost suite of micro- and nanofabrication platforms which allows greater process flexibility and short development cycles. In traditional manufacturing environments, virtually all fabrication happens on 6-12” substrates–which requires prohibitively expensive fabrication facilities (“fabs”). By scaling the substrate size down to 1-2”, Inchfab reduces the capital cost and physical footprint of a fab by two to three orders of magnitude, while still retaining a similar level of performance. Additionally, the design of the Inchfab will allow users to develop fully-customizable fabrication processes, accommodating non-traditional materials and process diversity. Ultimately, the Inchfab platform will enable innovative device designs which currently have limited possibility of being realized. This CRADA project worked on preliminary research to test the feasibility of the Inchfab platform by utilizing equipment at Berkeley Lab to evaluate test samples and characterize equipment performance.

42 ENGINEERING↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Integrating Carbon Capture, Utilization, & Sequestration into Chemical Pulp Mills

The U.S. pulp and paper industry presents a unique and largely untapped opportunity for large- scale carbon dioxide removal (CDR). Unlike most industrial sectors, pulp mills rely heavily on biomass, meaning that much of their carbon emissions originate from atmospheric CO₂ that was recently captured by plants. If this biogenic CO₂ can be captured and permanently stored, pulp mills can be transformed from carbon emitters into net carbon removal facilities. This project was motivated by that opportunity and aimed to develop and evaluate integrated, low-cost strategies for capturing, utilizing, and sequestering CO₂ within existing chemical pulping operations. The scope of this work focused on four complementary innovations designed to integrate seamlessly into kraft pulp mill infrastructure: (1) in situ CO₂ capture within the recovery cycle, (2) oxy-fuel retrofitting of the rotary lime kiln to produce a high-purity CO₂ stream, (3) ex situ CO₂ capture and mineralization using pulp mill residues (dregs, grits, and lime mud), and (4) beneficial reuse of these residues as mineral carbonate fertilizers. The project combined process modeling, laboratory experimentation, life cycle assessment (LCA), and field trials to evaluate the technical feasibility, economic viability, and environmental impact of these approaches. The results demonstrate that pulp mills can serve as effective platforms for carbon removal when equipped with integrated carbon capture systems. Process modeling showed that combining sodium spiking with oxy-fuel calcination significantly enhances CO₂ capture efficiency while reducing costs by up to 31% compared to conventional configurations. Experimental work further revealed that calcination behavior in high-CO₂ environments differs substantially from traditional systems, leading to the development of a new kinetic model that predicts reaction rates under these conditions. This model provides essential design guidance for next-generation decarbonized lime kilns. In parallel, the project demonstrated that alkaline mineral residues generated during pulping operations can be repurposed as a sustainable alternative to agricultural lime. Across a wide range of soils in the southeastern United States, these materials performed equivalently to commercial lime in adjusting soil pH while offering lower greenhouse gas emissions and reduced cost. Field and greenhouse studies confirmed that crop and tree growth responses were comparable, supporting their viability as a drop-in replacement. This co-product pathway provides a practical utilization strategy that offsets costs and improves overall system economics. A major contribution of this project is the first comprehensive life cycle assessment of carbon removal in pulp and paper systems across multiple system boundaries. Results show that retrofitted mills can achieve carbon removal efficiencies ranging from 12% to 92%, depending on how the system is defined. This finding highlights a critical issue in carbon accounting: reported performance is highly sensitive to methodological choices. By explicitly quantifying these differences, this work provides valuable guidance for policymakers, carbon registries, and project developers working to standardize carbon removal metrics. From a commercialization perspective, the technologies investigated in this project are well- aligned with existing industrial infrastructure, minimizing the need for entirely new facilities. 3 DE-EE0009413 Industry engagement throughout the project—including collaboration with pulp and paper companies, equipment manufacturers, and carbon removal developers—has accelerated the transition from research to deployment. Notably, a commercial developer is actively pursuing carbon capture projects at pulp mills in the southeastern United States and has cited this research as a contributing foundation. The emergence of voluntary carbon markets and long-term offtake agreements further strengthens the business case for implementation. The broader public benefits of this work are significant. By enabling large-scale carbon removal using existing industrial systems, this approach offers a near-term pathway to reduce atmospheric CO₂ concentrations while supporting domestic manufacturing and rural economies. The reuse of industrial residues as fertilizers reduces reliance on mined materials, lowers costs for farmers, and decreases environmental impacts associated with conventional lime production. In addition, the project has supported workforce development by training graduate students and researchers in carbon capture technologies, helping to build capacity in a critical area of national interest. In conclusion, this project demonstrates that integrated carbon capture, utilization, and sequestration in pulp mills is both technically feasible and economically promising. By combining process innovation, experimental validation, and systems-level analysis, the work advances the understanding of how biomass-based industries can contribute to climate mitigation. The findings provide a strong foundation for commercial deployment and offer a scalable solution for transforming a major U.S. industry into a source of durable carbon removal.

09 BIOMASS FUELS↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Substitution of virgin carbon fiber with low-cost recycled fiber in automotive grade injection molding polyamide 66 for equivalent composite mechanical performance with improved sustainability

Recycled carbon fiber has historically proven challenging to integrate into composite manufacturing due in no small part to the low-density, randomly oriented, discontinuous fiber format that results from typical recycling. Discontinuous fiber requires the use of alternative technologies than those traditionally applied to continuous fiber (e.g., hand lay-up, winding). Extrusion compounding is one such applicable technology, but material transfer into the system requires alternative feeding equipment or the use of an altered procedure as trialed in this research. In this study, an injection molding compound for automotive applications was prepared with recycled carbon fiber and compared against an existing commercial compound. Input fibers and molded compound were evaluated for mechanical performance, while relevant variables such as compounded fiber alignment and aspect ratio were compared to the existing baseline material to confirm a like-for-like composite material structure. Overall, analysis indicates that recycled fiber performs similarly to virgin fiber reinforcement, demonstrating that recycled fiber may be a viable drop-in replacement for short-fiber discontinuous applications.

42 ENGINEERING↗