Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Far-infrared spectral observations of Saturn and its rings

The spectrum of Saturn and its rings between 45 and 115 microns has been measured at an average resolving power of 14 from the NASA Lear Jet. The combined brightness temperature of the rings and planetary disk decreases beyond 65 microns, in disagreement with previous results. A brightness temperature of 65 + or - 10 K is obtained for the planetary disk in the 80-110-micron wavelength range if a large-particle, constant-emissivity model is assumed for the rings. The possible effects of small particles in the rings are briefly considered.

Ward, D. B.↗

Resolution enhanced sound detecting apparatus

An apparatus is described for enhancing the resolution of a sound detector of the type which includes an acoustic mirror for focusing sound from an object onto a microphone to enable the determination of the location from which the sound arises. The enhancement apparatus includes an enclosure which surrounds the space between the mirror and microphone, and contains a gas heavier than air, such as Freon, through which sound moves slower and therefore with a shorter wavelength than in air, so that a mirror of given size has greater resolving power. An acoustically transparent front wall of the enclosure which lies forward of the mirror, can include a pair of thin sheets with pressured air between them, to form an end of the region of heavy gas into a concave shape.

Kendall, J. M.↗

A liquid-helium-cooled grating spectrometer for far infrared astronomical observations

A liquid-helium-cooled grating spectrometer has been developed for low-resolution far-infrared spectrometric measurements of astronomical sources conducted by the 30-cm NASA Lear Jet telescope. Simple MOSFET coupled transimpedance preamplifiers were adopted for the spectrometer design. The infrared spectrometer has resolving powers from 10 to 150 over the wavelength range from 45 to 115 microns.

Houck, J. R.↗

Faint-object spectrograph for Space Telescope

The paper presents the Faint Object Spectrograph (FOS) for the Space Telescope to provide a digitized spectra of faint astronomical objects over the 115 to 700 nm wavelength range at resolving powers of 1000 and 100. A variety of concave gratings and prisms is employed to form nearly stigmatic spectra on one of the two Digicon photon counting detectors which are optimized for two different but overlapping ranges. The scientific goals associated with quasars, active galaxies, and objects within our solar system are discussed, and the FOS optical design features, including detectors, electronics, signal processing, power supplies, and data handling are examined. The FOS structural system, mechanism, and controls are described, along with the predicted performance capabilities in the spectral and spectropolarimetry modes. Finally, system performance parameters, including spatial resolution, time resolution, noise, and efficiency are discussed.

Harms, r. J.↗

Interstellar abundance determination using IUE data

Analysis of the silicon interstellar abundances was made for more heavily reddened lines of sight than were accessible to the Copernicus satellite. Silicon rarely had accurate column densities determined from Copernicus data because the available lines all lie on the flat portion of the curve of growth. With International Ultraviolet Explorer (IUE) it is possible to reach color excesses of E(B-V) approximately 0.5-0.7, and in addition obtain data on the weak SiII line at 1808 A, so that a wide range of oscillator strengths is available. The lower resolving power of the IUE causes difficulties in that several of the SiII lines are blended with strong lines of other species. Data on the lines of sight analyzed suggested that some of the absorption lines fall on the damped portion of the curve of growth, implying that silicon may not be as highly depleted as expected.

Joseph, C. L.↗

Need for high resolution in VUV Rydberg state spectroscopy

The paper emphasizes the necessity of high energy resolution (resolving powers greater than 100,000) in VUV spectroscopic determinations of atomic and molecular Rydberg electronic structures. Attention is given to spectral observations of Rydberg levels in Ge I near the 4p 2P(0)1/2 limit, in Sr I near the 4d 2D3/2 limit, and in diatomic hydrogen halides (especially H I) below the X2Pi3/2 limit.

Ginter, M. L.↗

Infrared Fourier spectrometer for airborne and ground-based astronomy

A unique high resolving power near-infrared, astronomical Fourier spectrometer has been constructed for use at both ground-based and airborne telescopes. Its capabilities include a limiting resolution of 0.01/cm and spectral coverage over the InSb detector sensitivity region (0.8-5.6 micron). The instrument is optimized for operation in environments inaccessible to other high-resolution Fourier spectrometers, namely, the Cassegrain focuses of conventional telescopes and the NASA Kuiper Airborne Observatory's 91-cm telescope. Details of the spectrometer are discussed, and various astronomical and laboratory spectra are presented.

Davis, D. S.↗

A 10 micron heterodyne receiver for ultra high resolution astronomical spectroscopy

An improved CO2 laser heterodyne spectrometer is examined. The present system uses reflective optics to eliminate refocusing at different wavelengths, and the local oscillator is a line-center-stabilized isotopic CO2 laser. A tunable diffraction grating makes possible easy and rapid selection of over 50 transitions per isotope of CO2. The IF (0 to 1.6 GHz) from the HgCdTe photomizer is analyzed by a 128-channel filter bank, consisting of 64 tunable 5-MHz filters and 64 fixed 25-MHz RF filters. These filters provide resolving powers of about 1,000,000 to 10,000,000 and velocity resolution of 50 to 250 m/sec; their output is synchronously detected, integrated, multiplexed and stored in a buffer memory for the desired integration period. Kitt Peak observations show the wide spectral coverage, wide mixer and electronics bandwidth, and high sensitivity of the system.

Buhl, D.↗

Introductory remarks: Photometry section

The principal goals of photometry and polarimetry are summarized. These goals include studies of the emission features of gaseous species of comets, the wavelength depenence of albedo, the phase function of scatter distribution, and time variation of rotation. Recent advances in photometric techniques were reviewed and include: use of proper filters, extension to the shortest and longest wavelengths, higher spectral resolving power, and polarizaton techniques.

Ahearn, M. F.↗

A possible technique for cometary studies with high angular and spectral resolution

The echelle spectrographs, designed for and used at the Cassegrain stations of the KPNO and CTIO 4-meter telescopes, are capable of cometary spectroscopy with seeing-limited angular resolution along the slit and with spectral resolving power (lambda/delta lambda) ranging from 10 to the 4th power to 10 to the 5th power. Various gratings, cameras and detectors can be used in combination for specific studies in the 3000A to 10,000A range.

Gull, T. R.↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

VAS temperature retrievals for NASA special network observations of 6 March 1982

VAS retrieval capability was studied. A mesoscale event consisting of a rapidly moving temperature perturbation with strong horizontal wind shear but shallow vertical extent occurred over Texas. The mesoscale event passed through the special radiosonde network and was documented with three hourly measurements. The event occurred behind a cold frontal cloud band during clear conditions. The event was accompanied by large skin temperature changes as the day progressed. This combination allows the testing of two important aspects of the retrieval algorithms with minimal cloud contamination and good ground truth. The first aspect concerns the horizontal and vertical resolving power of the retrievals and the second aspect concerns sensitivity to the boundary term. The NASA special network radiosonde is proven to be useful. It is demonstrated that: the VAS is capable, of delineating a mesoscale, normal retrieval procedure has the deficiency of oversmoothing, but this can be corrected, to document first quess dependence, and a superior data set to evolve better techniques for treating the surface boundary problem.

Hayden, C. M.↗

Large Deployable Reflector Science and Technology Workshop. Volume 2: Scientific Rationale and Technology Requirements

The scientific rationale for the large deployable reflector (LDR) and the overall technological requirements are discussed. The main scientific objectives include studies of the origins of planets, stars and galaxies, and of the ultimate fate of the universe. The envisioned studies require a telescope with a diameter of at least 20 m, diffraction-limited to wavelengths as short as 30-50 micron. In addition, light-bucket operation with 1 arcsec spatial resolution in the 2-4 microns wavelength region would be useful in studies of high-redshifted galaxies. Such a telescope would provide a large increase in spectroscopic sensitivity and spatial resolving power compared with existing or planned infrared telescopes.

Hollenbach, D.↗

Reflecting Schmidt imaging spectrometers

A new wide-angle imaging spectrometer configuration is proposed where an all-reflecting Schmidt camera is used with a prism spectrometer to give a field of view up to 60 deg or more. Four different designs using this approach are presented. These are the Imaging Spectrometer Free Flyer, the Shuttle Imaging Spectrometer A, the Shuttle Imaging Spectrometer B, and the Wide-Field System. These systems are capable of broadband spectral coverage from 0.4 to 2.5 microns, with footprints 20 m on a side or less, and with swath widths hundreds of kilometers; they are capable of spectral resolving powers of 200 or more.

Breckinridge, J. B.↗

Cooled grating array spectrometer for 0.6-5 microns

A grating spectrometer, designed to illuminate an array of 122 InSb photodiodes with minimum aberrations and maximum speed, has been constructed. The instrument will be used on the 5 meter Hale telescope at Palomar Observatory, and is easily adaptable to telescopes of various focal ratios. A resolving power of 100-1000 can be obtained at wavelengths between 0.6 microns and 5 microns with remotely interchangeable gratings. The spectrometer is sufficiently compact to fit on the 8-inch work surface of a commercially available dewar, and uses simple on-axis spherical and paraboloidal optical elements. The camera mirror produces an f/2.5 beam which, with the 0.2 mm detectors, allows a 3-in. focal-plane aperture on the 5 meter telescope. All rays fall within a 100 microns blur circle at all points along the array. Distortions have been corrected with a tilted field flattening lens in front of the detector.

Nordholt, J. E.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗

FUN with PANURGE - High mass resolution ion microprobe measurements of Mg in Allende inclusions

Isotopic ratios have been determined, at a precision level approaching that of counting statistics using beam switching, by employing PANURGE, a modified CAMECA IMS3F ion microprobe at a mass resolving power of 5000. This technique is used to determine the isotopic composition of Mg and Si and the atomic ratio of Al/Mg in minerals from the Allende inclusion WA and the Allende FUN inclusion C1. Results show enrichment in Mg-26 of up to 260 percent. Results of Mg and Al/Mg measurements on cogenetic spinel inclusion and host plagiclase crystals show Mg-Al isochrons in excellent agreement with precise mineral isochrons determined by thermal emission mass spectrometry. The measurements are found to confirm the presence of substantial excess Mg-26 in WA and its near absence in C1. Data is obtained which indicates a metamorphic reequilibrium of Mg in Allende plagioclase at least 0.6 my after WA formation. Ion probe measurements are obtained which confirm that the Mg composition in Allende C1 is highly fractionated and is uniform among pyroxene, melilite, plagioclase, spinel crystals, and spinel included in melilite and plagioclase crystals.

Huneke, J. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗