Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simulating single-particle dynamics in magnetized plasmas: The RMF code

The RMF (Rotating Magnetic Field) code is designed to calculate the motion of a charged particle in a given electromagnetic field. It integrates Hamilton’s equations in cylindrical coordinates using an adaptive predictor-corrector double-precision variable-coefficient ordinary differential equation solver for speed and accuracy. RMF has multiple capabilities for the field. Particle motion is initialized by specifying the position and velocity vectors. Here, the six-dimensional state vector and derived quantities are saved as functions of time. A post-processing graphics code, XDRAW, is used on the stored output to plot up to 12 windows of any two quantities using different colors to denote successive time intervals. Multiple cases of RMF may be run in parallel and perform data mining on the results. Recent features are a synthetic diagnostic for simulating the observations of charge-exchange-neutral energy distributions and RF grids to explore a Fermi acceleration parallel to static magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion of growth of matter perturbations in f(R) gravity

We study the growth of matter density perturbations {delta}{sub m} for a number of viable f(R) gravity models that satisfy both cosmological and local gravity constraints, where the Lagrangian density f is a function of the Ricci scalar R. If the parameter m{identical_to}Rf{sub ,RR}/f{sub ,R} today is larger than the order of 10{sup -6}, linear perturbations relevant to the matter power spectrum evolve with a growth rate s{identical_to}dln{delta}{sub m}/dlna (a is the scale factor) that is larger than in the {lambda}CDM model. We find the window in the free parameter space of our models for which spatial dispersion of the growth index {gamma}{sub 0}{identical_to}{gamma}(z=0) (z is the redshift) appears in the range of values 0.40 < or approx. {gamma}{sub 0} < or approx. 0.55, as well as the region in parameter space for which there is essentially no dispersion and {gamma}{sub 0} converges to values around 0.40 < or approx. {gamma}{sub 0} < or approx. 0.43. These latter values are much lower than in the {lambda}CDM model. We show that these unusual dispersed or converged spectra are present in most of the viable f(R) models with m(z=0) larger than the order of 10{sup -6}. These properties will be essential in the quest for f(R) modified gravity models using future high-precision observations and they confirm the possibility to distinguish clearly most of these models from the {lambda}CDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Single and repetitive short-pulse high-power microwave window breakdown

The mechanisms of high-power microwave breakdown for single and repetitive short pulses are analyzed. By calculation, multipactor saturation with electron density much higher than the critical plasma density is found not to result in microwave cutoff. It is local high pressure about Torr class that rapid plasma avalanche and final breakdown are realized in a 10-20 ns short pulse. It is found by calculation that the power deposited by saturated multipactor and the rf loss of protrusions are sufficient to induce vaporizing surface material and enhancing the ambient pressure in a single short pulse. For repetitive pulses, the accumulation of heat and plasma may respectively carbonize the surface material and lower the repetitive breakdown threshold.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PART 2: Initial Beam Dynamics Results of an Integrated and Compact 1.3 GHZ Superconducting Radio Frequency (SRF) Electron Source

This paper is the continuation of a technical paper which is called “Detailed Electromagnetic Design of an Integrated and Compact 1.3 GHz Superconducting Radio Frequency (SRF) Electron Source” [1]. In the previous paper, we examined if a promising RF electromagnetic design of the gun and cathode region could be achieved. Further, we examined if this gun region could be fully integrated, in terms of the electromagnetic RF design, with the rest of the accelerator, keeping in mind the overall goal of compactness and reduction of duplicative infrastructure commonly associated with separated function electron guns and structures. While we convinced ourselves thus far that the RF electromagnetic design of our concept is feasible, we also needed to perform particle tracking to assess the beam properties through the entire system, understand and remediate any beam loss. For this step, we examined the cathode region and analyzed the gating process of the thermionic cathode, as losses would most likely be attributed to releasing electrons into the accelerating structure during an unfavorable phase window.

43 PARTICLE ACCELERATORS↗

Radiofrequency attenuator and method

Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

47 OTHER INSTRUMENTATION↗

Radiofrequency attenuator and method

Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3 C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

47 OTHER INSTRUMENTATION↗

Optimization of Binning Parameters in the Feynman Variance-to-Mean Method for Delayed Neutron Reinterrogation

The focus of this work is to determine the optimal input parameters for analyzing active interrogation data that utilizes the physics of the delayed neutron re-interrogation technique. This work compares the signature from an active neutron measurement of a highly enriched uranium (HEU) system to an active background measurement (i.e., without the HEU item in place). The item being measured represents a 21.8 kg metal sphere of HEU (93 weight percent) assembled from a subset of the Rocky Flats (RF) uranium hemishells. The detection system consisted of two NoMAD neutron multiplicity detectors, a SNAP III neutron detector, and a Thermo Fisher P211 pulsed 14 MeV neutron source. In addition, varying analyses of the NoMAD list-mode detector data are performed to determine whether it is preferential to use a particular analysis bin size for producing Feynman histograms, selection of pulses to prevent discrepancies from buildup, or window of time during the pulsed neutron interrogation. This work is still currently ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of cavity and window for THz gyrotron

In this paper study of cavity and window has been carried out using Ansoft HFSS for Terahertz Gyrotron. Eigen mode analysis of the cavity has been carried out at 1 THz. An idea about the operating modes in the cavity of the Gyrotron and obtained the simulated Eigen frequency and field pattern of the modes. The design of window for 1 THz Gyrotron has also been carried out using HFSS. The simulated results have also been compared with ST microwave studio. (author)

43 PARTICLE ACCELERATORS↗

Radio Astronomy Software Defined Receiver Project

The paper describes a Radio Astronomy Software Defined Receiver (RASDR) that is currently under development. RASDR is targeted for use by amateurs and small institutions where cost is a primary consideration. The receiver will operate from HF thru 2.8 GHz. Front-end components such as preamps, block down-converters and pre-select bandpass filters are outside the scope of this development and will be provided by the user. The receiver includes RF amplifiers and attenuators, synthesized LOs, quadrature down converters, dual 8 bit ADCs and a Signal Processor that provides firmware processing of the digital bit stream. RASDR will interface to a user s PC via a USB or higher speed Ethernet LAN connection. The PC will run software that provides processing of the bit stream, a graphical user interface, as well as data analysis and storage. Software should support MAC OS, Windows and Linux platforms and will focus on such radio astronomy applications as total power measurements, pulsar detection, and spectral line studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-consistent simulation of radio frequency multipactor on micro-grooved dielectric surface

The multipactor plays a key role in the surface breakdown on the feed dielectric window irradiated by high power microwave. To study the suppression of multipactor, a 2D electrostatic PIC-MCC simulation code was developed. The space charge field, including surface deposited charge and multipactor electron charge field, is obtained by solving 2D Poisson's equation in time. Therefore, the simulation is self-consistent and does not require presetting a fixed space charge field. By using this code, the self-consistent simulation of the RF multipactor on the periodic micro-grooved dielectric surface is realized. The 2D space distributions of the multipactor electrons and space charge field are presented. From the simulation results, it can be found that only half slopes have multipactor discharge when the slope angle exceeds a certain value, and the groove presents a pronounced suppression effect on the multipactor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Triggering Klystrons

To determine if klystrons will perform to the specifications of the LCLS (Linac Coherent Light Source) project, a new digital trigger controller is needed for the Klystron/Microwave Department Test Laboratory. The controller needed to be programmed and Windows based user interface software needed to be written to interface with the device over a USB (Universal Serial Bus). Programming the device consisted of writing logic in VHDL (VHSIC (Very High Speed Integrated Circuits) hardware description language), and the Windows interface software was written in C++. Xilinx ISE (Integrated Software Environment) was used to compile the VHDL code and program the device, and Microsoft Visual Studio 2005 was used to compile the C++ based Windows software. The device was programmed in such a way as to easily allow read/write operations to it using a simple addressing model, and Windows software was developed to interface with the device over a USB connection. A method of setting configuration registers in the trigger device is absolutely necessary to the development of a new triggering system, and the method developed will fulfill this need adequately. More work is needed before the new trigger system is ready for use. The configuration registers in the device need to be fully integrated with the logic that will generate the RF signals, and this system will need to be tested extensively to determine if it meets the requirements for low noise trigger outputs.

Stefan, Kelton D.↗

TU-H-CAMPUS-IeP3-04: Evaluation of Changes in Quantitative Ultrasound Parameters During Prostate Radiotherapy

Purpose: Clarity Autoscan ultrasound monitoring system allows acquisition of raw radiofrequency (RF) ultrasound data prior and during radiotherapy. This enables the computation of 3D Quantitative Ultrasound (QUS) tissue parametric maps from. We aim to evaluate whether QUS parameters undergo changes with radiotherapy and thus potentially be used as early predictors and/or markers of treatment response in prostate cancer patients. Methods: In-vivo evaluation was performed under IRB protocol to allow data collection in prostate patients treated with VMAT whereby prostate was imaged through the acoustic window of the perineum. QUS spectroscopy analysis was carried out by computing a tissue power spectrum normalized to the power spectrum obtained from a quartz to remove system transfer function effects. A ROI was selected within the 3D image volume of the prostate. Because longitudinal registration was optimal, the same features could be used to select ROIs at roughly the same location in images acquired on different days. Parametric maps were generated within the rectangular ROIs with window sizes that were approximately 8 times the wavelength of the ultrasound. The mid-band fit (MBF), spectral slope (SS) and spectral intercept (SI) QUS parameters were computed for each window within the ROI and displayed as parametric maps. Quantitative parameters were obtained by averaging each of the spectral parameters over the whole ROI. Results: Data was acquired for over 21 treatment fractions. Preliminary results show changes in the parametric maps. MBF values decreased from −33.9 dB to −38.7 dB from pre-treatment to the last day of treatment. The spectral slope increased from −1.1 a.u. to −0.5 a.u., and spectral intercept decreased from −28.2 dB to −36.3 dB over the 21 treatment regimen. Conclusion: QUS parametric maps change over the course of treatment which warrants further investigation in their potential use for treatment planning and predicting treatment outcomes. Research was supported by Elekta.

60 APPLIED LIFE SCIENCES↗

Progress on Gyrotrons for ITER and Future Fusion Reactors

The prototype of the Japan 170 GHz ITER gyrotron holds the energy and efficiency world record of 2.88 GJ (0.8 MW, 3600 s, 57%) with 55% efficiency at 1 MW, 800 s, whereas the Russian 170 GHz ITER prototype tube achieved 0.83 MW with a pulse duration of 203 s at 48% efficiency and 1 MW at 116 s and 52%. The record parameters of the European megawatt-class 140 GHz gyrotron for the Stellarator Wendelstein W7-X are: 0.92 MW output power at 1800 s pulse duration, almost 45% efficiency and 97.5% Gaussian mode purity. All these gyrotrons employ a cylindrical cavity, a quasi-optical output coupler, a synthetic diamond window and a single-stage depressed collector (SDC) for energy recovery. In coaxial cavities the existence of the longitudinally corrugated inner conductor reduces the problems of mode competition and limiting current, thus allowing one to use even higher order modes with lower Ohmic attenuation than in cylindrical cavities. Synthetic diamond windows with a transmission capability of 2 MW, continuous wave (CW) are feasible. In order to keep the number of the required gyrotrons and magnets as low as possible, to reduce the costs of the ITER 26 MW, 170 GHz ECRH system and to allow compact upper launchers for plasma stabilization, 2 MW mm-wave power per gyrotron tube is desirable. The FZK pre-prototype tube for an EU 170 GHz, 2 MW ITER gyrotron has achieved 1.8 MW at 28% efficiency (without depressed collector). Design studies for a 4 MW 170 GHz coaxial-cavity gyrotron with two synthetic diamond output windows and two 2 MW mm-wave output beams for future fusion reactors are currently being performed at FZK. The availability of sources with fast frequency tunability (several GHz s{sup -1}, tuning in 1.5-2.5% steps for about ten different frequencies) would permit the use of a simple, fixed, non-steerable mirror antenna for local current drive (ECCD) experiments and plasma stabilization. GYCOM in Russia develops in collaboration with IPP Garching and FZK an industrial, frequency-tunable 1 MW gyrotron with almost 50% efficiency (SDC) for ASDEX Upgrade. A four-frequency tube (105, 117, 127 and 140 GHz) delivered in 10 s pulses 0.7 MW at 105 GHz and 0.9 MW at 140 GHz. After the installation of a diamond Brewster window, the GYCOM group will operate this gyrotron also at the two intermediate frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse modulated microwave operation on large bore electron cyclotron resonance ion source with cylindrically comb-shaped magnetic fields configuration

In order to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure, the magnetic field configuration is constructed by a pair of comb-shaped magnet which has opposite polarity each other, and which cylindrically surrounds the plasma chamber. By using the pulse microwave mode operation, we aim at generation of plasma with parameters that cannot be achieved at the continuous microwave (cw) mode. The maximum beam current is obtained in the experimental condition of the pulse width 100-200 {mu}s at the duty ratio 40%-50%. According to probe measurements of the ECR plasma, it is found the electron density in the pulse mode is larger than that in the cw mode, while the electron temperatures in the pulse mode were lower than that in the cw mode. These indirect evidences cause to enhance ion beams in the pulse mode operation, and then suggest a spread of operation windows for plasma parameters suitable to production of molecular or cluster ions.

43 PARTICLE ACCELERATORS↗

Multi-purpose 805 MHz Pillbox RF Cavity for Muon Acceleration Studies

An 805 MHz RF pillbox cavity has been designed and constructed to investigate potential muon beam acceleration and cooling techniques. The cavity can operate at vacuum or under pressure to 100 atmospheres, at room temperature or in a liquid nitrogen bath at 77 K. The cavity is designed for easy assembly and disassembly with bolted construction using aluminum seals. The surfaces of the end walls of the cavity can be replaced with different materials such as copper, aluminum, beryllium, or molybdenum, and with different geometries such as shaped windows or grid structures. Different surface treatments such as electro polished, high-pressure water cleaned, and atomic layer deposition are being considered for testing. The cavity has been designed to fit inside the 5-Tesla solenoid in the MuCool Test Area at Fermilab. Current status of the cavity prepared for initial conditioning and operation in the external magnetic field is discussed.

ACCELERATION↗

The roles of the dielectric constant and the relative level of conduction band of high-k composite with Si in improving the memory performance of charge-trapping memory devices

The memory structures Pt/Al{sub 2}O{sub 3}/(TiO{sub 2}){sub x}(Al{sub 2}O{sub 3}){sub 1−x}/Al{sub 2}O{sub 3}/p-Si(nominal composition x = 0.05, 0.50 and 0.70) were fabricated by using rf-magnetron sputtering and atomic layer deposition techniques, in which the dielectric constant and the bottom of the conduction band of the high-k composite (TiO{sub 2}){sub x}(Al{sub 2}O{sub 3}){sub 1−x} were adjusted by controlling the partial composition of Al{sub 2}O{sub 3}. With the largest dielectric constant and the lowest deviation from the bottom of the conduction band of Si, (TiO{sub 2}){sub 0.7}(Al{sub 2}O{sub 3}){sub 0.3} memory devices show the largest memory window of 7.54 V, the fast programming/erasing speed and excellent endurance and retention characteristics, which were ascribed to the special structural design, proper combination of dielectric constant and band alignment in the high-k composite (TiO{sub 2}){sub 0.7}(Al{sub 2}O{sub 3}){sub 0.3}.

36 MATERIALS SCIENCE↗

Testing of PIP-II pre-production 650 MHz couplers in warm test stand and in cryomodule

650 MHz fundamental power couplers were developed for PIP-II project to deliver RF power for low-beta and high-beta elliptical cavities. Few prototypes were built and tested and after some modification we built 8 pre-production couplers (with few spares for vacuum side) for HB650 cryomodule. All couplers were successfully tested in pulse mode (up to 100kW) and in CW mode (up to 50kW) in test stand at full reflection at 8 phases. In baseline configuration with DC bias we do not see any multipactoring activity after short processing. We also tested power processing without bias for uncoated and TiN coated ceramic window. Results of these studies presented in this paper. One of the coupler was assembled on LB650 cavity and tested at cryogenic environment in STC cryostat at ~20kW power with full reflection at different reflection phase. We also demonstrated good result from power processing without bias for warm and cold cavity. Six couplers were assembled on HB650 cavities in pre-production cryomodule. Test results from cryomodule qualification is discussing in this paper.

43 PARTICLE ACCELERATORS↗

Photo-assisted etching of silicon in chlorine- and bromine-containing plasmas

Cl{sub 2}, Br{sub 2}, HBr, Br{sub 2}/Cl{sub 2}, and HBr/Cl{sub 2} feed gases diluted in Ar (50%–50% by volume) were used to study etching of p-type Si(100) in a rf inductively coupled, Faraday-shielded plasma, with a focus on the photo-assisted etching component. Etching rates were measured as a function of ion energy. Etching at ion energies below the threshold for ion-assisted etching was observed in all cases, with Br{sub 2}/Ar and HBr/Cl{sub 2}/Ar plasmas having the lowest and highest sub-threshold etching rates, respectively. Sub-threshold etching rates scaled with the product of surface halogen coverage (measured by X-ray photoelectron spectroscopy) and Ar emission intensity (7504 Å). Etching rates measured under MgF{sub 2}, quartz, and opaque windows showed that sub-threshold etching is due to photon-stimulated processes on the surface, with vacuum ultraviolet photons being much more effective than longer wavelengths. Scanning electron and atomic force microscopy revealed that photo-etched surfaces were very rough, quite likely due to the inability of the photo-assisted process to remove contaminants from the surface. Photo-assisted etching in Cl{sub 2}/Ar plasmas resulted in the formation of 4-sided pyramidal features with bases that formed an angle of 45° with respect to 〈110〉 cleavage planes, suggesting that photo-assisted etching can be sensitive to crystal orientation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗