Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROC analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

Purpose: To investigate the feasibility of a new two-dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT). Methods: With IRB approval and informed consent, a data set of two-view DBTs from 42 breasts containing biopsy-proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three-dimensional (3D) DBT volume. Signal-to-noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two-fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis. Results: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case-based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance. Conclusions: The authors' experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Orbiting Sample Capture and Orientation System Architecture for Potential Mars Sample Return

An orbiting sample capture and orientation system architecture for a Rendezvous and Orbiting Sample Capture System (ROCS) concept was developed to enable spacecraft based, in-orbit capture, orientation, and transfer of a Mars sample container into a containment vessel as part of a potential Mars Sample Return (MSR) campaign. An analysis of the system functions, requirements, interactions, and constraints was performed. A trade study was carried out on relevant technologies, and a set of evaluation criteria was developed to help determine the most feasible concepts for implementation. The Mars Capture and Re-orientation for the potential Next Mars Orbiter (MACARONE) concept is proposed as a promising system architecture for the ROCS Capture and Orient Module (COM). The concept uses a sliding trap door for Orbiting Sample (OS) capture, a Motorized Cups Mechanism for OS orientation, and a 2 DOF Turret Arm with a paddle for transferring the OS into a containment vessel. This approach facilitates modularity, development flexibility, test-ability in a 1G environment, analyze-ability without the need to simulate or test for 0G contact dynamics, ability to encapsulate potential dust surrounding the OS, and ability to be ejected to reduce the probability of Earth exposure to non-sterilized Mars material.

Lalla, Karan↗

Identification of aberrant circular RNA expression and its potential clinical value in primary great saphenous vein varicosities

Highlights: • This study identified 232 significantly aberrant circRNAs in primary great saphenous vein varicosities (PGSVVs). • A circRNA-miRNA-gene co-expression network was created. • Hsa{sub c}irc{sub 0}006427, hsa{sub c}irc{sub 0}089810 and hsa{sub c}irc{sub 0}005267 might be potential biological markers for PGSVVs. This study aimed to identify aberrant circRNA expression in primary great saphenous vein varicosities (PGSVVs) and investigate its potential clinical significance. High-throughput sequencing was applied to analyze the differential expression of circRNAs in three paired vein samples of PGSVVs and a control group. Computational bioinformatics analyses, including gene ontology (GO) analysis and encyclopedia of genes and genomes (KEGG) pathway analysis, were performed to further enrich microRNA data. Real-time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) was used to verify the selected aberrant circRNAs in all vein samples, and a receiver operating characteristic (ROC) curve was plotted to evaluate the diagnostic and potential clinical significance. A total of 232 circRNAs were significantly aberrantly expressed in PGSVVs, including 105 and 127 upregulated and downregulated circRNAs, respectively. The predicted top 10 downstream miRNAs of the significantly altered circRNAs are hsa-miR-103a-2-5p, hsa-miR-141-5p, hsa-miR-3692-5p, hsa-miR-4659a-3p, hsa-miR-4659b-3p, hsa-miR-4691-5p, hsa-miR-4778-3p, hsa-miR-6738-3p, hsa-miR-6792-3p and hsa-miR-6873-3p. GO analysis revealed that the most enriched and meaningful biological process, cellular component, and molecular function terms were related to the regulation of catabolic processes, the cytoplasm and ATP binding, respectively. The most enriched and meaningful pathways revealed by KEGG pathway analysis were related to “axon guidance” “vitamin digestion and absorption” and “NF-Kappa B signaling pathway”. Hsa{sub c}irc{sub 0}006427 (P = 0.007), hsa{sub c}irc{sub 0}089810 (P = 0.044) and hsa{sub c}irc{sub 0}005267 (P = 0.049) were significantly downregulated in the PGSVV group relative to their expression levels in the control group, and the area under the ROC curve was 0.9091, 0.8025 and 0.8148, respectively. This study demonstrated that circRNAs were differentially expressed in PGSVVs, and highlights the crucial roles of circRNAs in the pathogenesis of PGSVVs and indicates that hsa{sub c}irc{sub 0}006427, hsa{sub c}irc{sub 0}089810 and hsa{sub c}irc{sub 0}005267 might be potential diagnostic and clinical biological markers.

60 APPLIED LIFE SCIENCES↗

Identification of candidate diagnostic and prognostic biomarkers for human prostate cancer: RPL22L1 and RPS21

Prostate cancer (PCa) is one of the most common malignancies in men worldwide. This study was designed to investigate the potential of Ribosomal Protein L22-like1 (RPL22L1) and Ribosomal Protein S21 (RPS21) as diagnostic and prognostic biomarkers for PCa. First, RPL22L1 and RPS21 were screened as the key molecular of PCa by bioinformatics analysis. Subsequently, the prostate tissue samples were stained for antibodies against RPL22L1 and RPS21. The unbiased signal quantification was performed by ImageJ software, and the results showed that the expression of RPL22L1 and RPS21 exhibited significant differences between the PCa tissues and the normal prostate tissues. Receiver-operating characteristics (ROC) curves were prepared, and then the area under the curve (AUC) values of RPL22L1 and RPS21 were calculated as 0.798 and 0.768, and the likelihood ratio (LR) values of RPL22L1 and RPS21 were calculated as 2.86 and 2.53. These data implied that the over-expression of RPL22L1 and RPS21 is associated with the presence of PCa. The further analysis suggested that the expression of RPL22L1 and RPS21 were significantly higher in high Gleason grade than they were in low Gleason grade. In addition, in vitro studies were undertaken to evaluate the roles of RPL22L1 and RPS21 in PCa. The results revealed that these genes promote PCa cell proliferation, migration and invasion, and inhibit PCa cell apoptosis. Taken together, these data showed that RPL22L1 and RPS21 exhibited higher expression in human prostate cancer tissue, and involved in PCa cell proliferation and invasion. This research provided a novel insight into diagnostic and prognostic biomarkers for PCa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretreatment Nomogram to Predict the Risk of Acute Urinary Retention After I-125 Prostate Brachytherapy

Purpose: Acute urinary retention (AUR) after iodine-125 (I-125) prostate brachytherapy negatively influences long-term quality of life and therefore should be prevented. We aimed to develop a nomogram to preoperatively predict the risk of AUR. Methods: Using the preoperative data of 714 consecutive patients who underwent I-125 prostate brachytherapy between 2005 and 2008 at our department, we modeled the probability of AUR. Multivariate logistic regression analysis was used to assess the predictive ability of a set of pretreatment predictors and the additional value of a new risk factor (the extent of prostate protrusion into the bladder). The performance of the final model was assessed with calibration and discrimination measures. Results: Of the 714 patients, 57 patients (8.0%) developed AUR after implantation. Multivariate analysis showed that the combination of prostate volume, IPSS score, neoadjuvant hormonal treatment and the extent of prostate protrusion contribute to the prediction of AUR. The discriminative value (receiver operator characteristic area, ROC) of the basic model (including prostate volume, International Prostate Symptom Score, and neoadjuvant hormonal treatment) to predict the development of AUR was 0.70. The addition of prostate protrusion significantly increased the discriminative power of the model (ROC 0.82). Calibration of this final model was good. The nomogram showed that among patients with a low sum score (<18 points), the risk of AUR was only 0%-5%. However, in patients with a high sum score (>35 points), the risk of AUR was more than 20%. Conclusion: This nomogram is a useful tool for physicians to predict the risk of AUR after I-125 prostate brachytherapy. The nomogram can aid in individualized treatment decision-making and patient counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Grade 3 or Higher Late Bowel Toxicity in Patients Undergoing Pelvic Radiation for Cervical Cancer: Results From a Prospective Study

Purpose: The present study investigates relationship between dose–volume parameters and severe bowel toxicity after postoperative radiation treatment (PORT) for cervical cancer. Methods and Materials: From June 2010 to December 2012, a total of 71 patients undergoing PORT were included. Small bowel (SB) and large bowel (LB) loops were contoured 2 cm above the target volume. The volume of SB and LB that received 15 Gy, 30 Gy, and 40 Gy was calculated (V15 SB, V15 LB, V30 SB, V30 LB, V40 SB, V 40 LB). On follow-up, bowel toxicity was scored using Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. A reciever operating characteristic (ROC) curve identified volume thresholds that predicted for grade 3 or higher toxicity with highest specificity. All data was dichotomized across these identified cut-off values. Univariate and multivariate analysis was performed using SPSS, version 15. Results: The median patient age was 47 years (range, 35-65 years). Of the 71 patients, 46 received image-guided intensity modulated radiation therapy, and 25 received conformal radiation (50 Gy in 25 fractions for 5 weeks). Overall, 63 of 71 patients received concurrent chemotherapy. On a median follow-up of 18 months (range, 8-29 months), grade 2 or higher bowel toxicity was seen in 22 of 71 patients (30.9%) and grade 3 or higher bowel toxicity was seen in 9 patients (12.6%). On univariate analysis, V15 SB <275 cc (P=.01), V30 SB <190 cc (P=.02), V40 SB <150 cc (P=.01), and V15 LB <250 cc (P=.03), and V40 LB <90 cc (P=.04) predicted for absence of grade 3 or higher toxicity. No other patient- or treatment-related factors were statistically significant. On multivariate analysis, only V15 SB (P=.002) and V15 LB (P=.03) were statistically significant. Conclusions: V 15 Gy SB and LB are independent predictors of late grade 3 or higher toxicity. Restricting V15 SB and V15 LB to <275 cc and <250 cc can reduce grade 3 or higher toxicity to less than 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Analysis of JV-Curves Applied to an Outdoor-Degrading CdTe Module (Presentation)

We present the application of a phenomenological four parameter equation to fit and analyze regularly measured current density-voltage JV curves of a CdTe module during 2.5 years of outdoor operation. The parameters are physically meaningful, i.e. the short circuit current density Jsc, open circuit voltage Voc and differential resistances Rsc, and Roc. For the chosen module, the fill factor FF degradation overweighs the degradation of Jsc and Voc. Interestingly, with outdoor exposure, not only the conductance at short circuit, Gsc, increases but also the Gsc(Jsc)-dependence. This is well explained with an increase in voltage dependent charge carrier collection in CdTe.

14 SOLAR ENERGY↗

Enhanced resting-state dynamics of the hemoglobin signal as a novel biomarker for detection of breast cancer

Purpose: The work presented here demonstrates an application of diffuse optical tomography (DOT) to the problem of breast-cancer diagnosis. The potential for using spatial and temporal variability measures of the hemoglobin signal to identify useful biomarkers was studied. Methods: DOT imaging data were collected using two instrumentation platforms the authors developed, which were suitable for exploring tissue dynamics while performing a simultaneous bilateral exam. For each component of the hemoglobin signal (e.g., total, oxygenated), the image time series was reduced to eight scalar metrics that were affected by one or more dynamic properties of the breast microvasculature (e.g., average amplitude, amplitude heterogeneity, strength of spatial coordination). Receiver-operator characteristic (ROC) analyses, comparing groups of subjects with breast cancer to various control groups (i.e., all noncancer subjects, only those with diagnosed benign breast pathology, and only those with no known breast pathology), were performed to evaluate the effect of cancer on the magnitudes of the metrics and of their interbreast differences and ratios. Results: For women with known breast cancer, simultaneous bilateral DOT breast measures reveal a marked increase in the resting-state amplitude of the vasomotor response in the hemoglobin signal for the affected breast, compared to the contralateral, noncancer breast. Reconstructed 3D spatial maps of observed dynamics also show that this behavior extends well beyond the tumor border. In an effort to identify biomarkers that have the potential to support clinical aims, a group of scalar quantities extracted from the time series measures was systematically examined. This analysis showed that many of the quantities obtained by computing paired responses from the bilateral scans (e.g., interbreast differences, ratios) reveal statistically significant differences between the cancer-positive and -negative subject groups, while the corresponding measures derived from individual breast scans do not. ROC analyses yield area-under-curve values in the 77%–87% range, depending on the metric, with sensitivity and specificity values ranging from 66% to 91%. An interesting result is the initially unexpected finding that the hemodynamic-image metrics are only weakly dependent on the tumor burden, implying that the DOT technique employed is sensitive to tumor-induced changes in the vascular dynamics of the surrounding breast tissue as well. Computational modeling studies serve to identify which properties of the vasomotor response (e.g., average amplitude, amplitude heterogeneity, and phase heterogeneity) principally determine the values of the metrics and their codependences. Findings from the modeling studies also serve to clarify the influence of spatial-response heterogeneity and of system-design limitations, and they reveal the impact that a complex dependence of metric values on the modeled behaviors has on the success in distinguishing between cancer-positive and -negative subjects. Conclusions: The authors identified promising hemoglobin-based biomarkers for breast cancer from measures of the resting-state dynamics of the vascular bed. A notable feature of these biomarkers is that their spatial extent encompasses a large fraction of the breast volume, which is mainly independent of tumor size. Tumor-induced induction of nitric oxide synthesis, a well-established concomitant of many breast cancers, is offered as a plausible biological causal factor for the reported findings.

60 APPLIED LIFE SCIENCES↗

Evaluation of the usefulness of novel biomarkers for drug-induced acute kidney injury in beagle dogs

As kidney is a major target organ affected by drug toxicity, early detection of renal injury is critical in preclinical drug development. In past decades, a series of novel biomarkers of drug-induced nephrotoxicity were discovered and verified in rats. However, limited data regarding the performance of novel biomarkers in non-rodent species are publicly available. To increase the applicability of these biomarkers, we evaluated the performance of 4 urinary biomarkers including neutrophil gelatinase-associated lipocalin (NGAL), clusterin, total protein, and N-acetyl-β-D-glucosaminidase (NAG), relative to histopathology and traditional clinical chemistry in beagle dogs with acute kidney injury (AKI) induced by gentamicin. The results showed that urinary NGAL and clusterin levels were significantly elevated in dogs on days 1 and 3 after administration of gentamicin, respectively. Gene expression analysis further provided mechanistic evidence to support that NGAL and clusterin are potential biomarkers for the early assessment of drug-induced renal damage. Furthermore, the high area (both AUCs = 1.000) under receiver operator characteristics (ROC) curve also indicated that NGAL and clusterin were the most sensitive biomarkers for detection of gentamicin-induced renal proximal tubular toxicity. Our results also suggested that NAG may be used in routine toxicity testing due to its sensitivity and robustness for detection of tissue injury. The present data will provide insights into the preclinical use of these biomarkers for detection of drug-induced AKI in non-rodent species. - Highlights: • Urinary NGAL, clusterin and NAG levels were significantly elevated in canine AKI. • NGAL and clusterin gene expression were increased following treatment with gentamicin. • NGAL and clusterin have high specificity and sensitivity for detection of AKI.

60 APPLIED LIFE SCIENCES↗

WE-E-17A-02: Predictive Modeling of Outcome Following SABR for NSCLC Based On Radiomics of FDG-PET Images

Purpose: This study aims to develop predictive models of patient outcome by extracting advanced imaging features (i.e., Radiomics) from FDG-PET images. Methods: We acquired pre-treatment PET scans for 51 stage I NSCLC patients treated with SABR. We calculated 139 quantitative features from each patient PET image, including 5 morphological features, 8 statistical features, 27 texture features, and 100 features from the intensity-volume histogram. Based on the imaging features, we aim to distinguish between 2 risk groups of patients: those with regional failure or distant metastasis versus those without. We investigated 3 pattern classification algorithms: linear discriminant analysis (LDA), naive Bayes (NB), and logistic regression (LR). To avoid the curse of dimensionality, we performed feature selection by first removing redundant features and then applying sequential forward selection using the wrapper approach. To evaluate the predictive performance, we performed 10-fold cross validation with 1000 random splits of the data and calculated the area under the ROC curve (AUC). Results: Feature selection identified 2 texture features (homogeneity and/or wavelet decompositions) for NB and LR, while for LDA SUVmax and one texture feature (correlation) were identified. All 3 classifiers achieved statistically significant improvements over conventional PET imaging metrics such as tumor volume (AUC = 0.668) and SUVmax (AUC = 0.737). Overall, NB achieved the best predictive performance (AUC = 0.806). This also compares favorably with MTV using the best threshold at an SUV of 11.6 (AUC = 0.746). At a sensitivity of 80%, NB achieved 69% specificity, while SUVmax and tumor volume only had 36% and 47% specificity. Conclusion: Through a systematic analysis of advanced PET imaging features, we are able to build models with improved predictive value over conventional imaging metrics. If validated in a large independent cohort, the proposed techniques could potentially aid in identifying patients who might benefit from adjuvant therapy.

60 APPLIED LIFE SCIENCES↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Redox oxidative cracking of n -hexane with Fe-substituted barium hexaaluminates as redox catalysts

Light olefins such as ethylene and propylene are critical building blocks in the chemical industry and are currently produced mainly from steam cracking of naphtha. However, the highly endothermic nature of steam generation and the cracking reactions make this process highly energy- and CO 2 -intensive. Coke formation in the steam cracker tubes represents another obstacle. To address these challenges, we proposed a chemical looping approach to convert naphtha into olefins via a redox oxidative cracking (ROC) process. In the present work, Fe-substituted barium hexaaluminates (BaFe x Al 12– x O 19 ) were investigated as oxygen carriers, or redox catalysts, to convert n -hexane to olefins via ROC. The cyclic redox scheme facilitated by the Fe-substituted hexaaluminates allows autothermal operation and higher olefin yields relative to the endothermic steam-cracking process. While base BaFe x Al 12– x O 19 ( x = 1, 2, 3, 4, 6) oxides showed high CO x yields (8.4–55.2%) in ROC of n -hexane, 20 wt% Na 2 WO 4 promotion of BaFe 6 Al 6 O 19 (20-NaW/BaFe6) significantly inhibited CO x formation (0.6–1.2% CO x yield) while oxidizing all the H 2 produced during cracking within a temperature range of 600–700 °C and GHSV of 9000 h –1 . Benefiting from the donation of selective lattice oxygen, we report 20-NaW/BaFe6 more than doubled the olefin yield when compared to that from thermal cracking (26.0% vs. 12.8%). Moreover, decreasing the GHSV from 9000 h –1 to 2250 h –1 resulted in 8.5% increase in n -hexane conversion on an absolute basis, while maintaining nearly the same olefin selectivity. Long-term stability of the 20-NaW/BaFe6 oxygen carrier was also demonstrated within 30 cycles at 700 °C and 2250 h –1 , achieving an olefin yield in the range of 31.3–32.4% and low CO x yield of 0.6–0.7%. XPS analysis of cycled BaFe6 revealed a shift towards near-surface Ba enrichment upon redox cycling. In comparison, both as-prepared and cycled 20-NaW/BaFe6 showed suppression of near surface Ba content, indicating that Na 2 WO 4 inhibited the migration of Ba into the near-surface region during n -hexane ROC and effectively suppressed non-selective oxidation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-C-17A-04: BEST IN PHYSICS (THERAPY) - A Supervised Framework for Automatic Contour Assessment for Radiotherapy Planning of Head- Neck Cancer

Purpose: Precise contour delineation of tumor targets and critical structures from CT simulations is essential for accurate radiotherapy (RT) treatment planning. However, manual and automatic delineation processes can be error prone due to limitations in imaging techniques and individual anatomic variability. Tedious and laborious manual verification is hence needed. This study develops a general framework for automatically assessing RT contours for head-neck cancer patients using geometric attribute distribution models (GADMs). Methods: Geometric attributes (centroid and volume) were computed from physician-approved RT contours of 29 head-neck patients. Considering anatomical correlation between neighboring structures, the GADM for each attribute was trained to characterize intra- and interpatient structure variations using principal component analysis. Each trained GADM was scalable and deformable, but constrained by the principal attribute variations of the training contours. A new hierarchical model adaptation algorithm was utilized to assess the RT contour correctness for a given patient. Receiver operating characteristic (ROC) curves were employed to evaluate and tune system parameters for the training models. Results: Experiments utilizing training and non-training data sets with simulated contouring errors were conducted to validate the framework performance. Promising assessment results of contour normality/abnormality for the training contour-based data were achieved with excellent accuracy (0.99), precision (0.99), recall (0.83), and F-score (0.97), while corresponding values of 0.84, 0.96, 0.83, and 0.9 were achieved for the non-training data. Furthermore, the areas under the ROC curves were above 0.9, validating the accuracy of this test. Conclusion: The proposed framework can reliably identify contour normality/abnormality based upon intra- and inter-structure constraints derived from clinically-approved contours. It also allows physicians to analytically determine the system parameters to fit various clinic requirements (e.g. as-low-as-possible false positives). It has great potential for improving RT work flow. More geometric attributes and training sets will be investigated to improve framework performance in the future.

60 APPLIED LIFE SCIENCES↗

Prototype Data Acquisition and Slow Control Systems for the Mu2e Experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10 000 over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable with direct searches at either present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system exploits otsdaq as its online Data Acquisition System (DAQ) solution. Furthermore, developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The read out controllers (ROCs) stream out zero-suppressed data continuously from the detector subsystems to the data transfer controllers (DTCs). The data stream is then read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events which are combined with the data flux coming from a cosmic-ray veto (CRV) system. The detector control system (DCS) has been developed using the experimental physics and industrial control system (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS has been integrated into otsdaq. A prototype of the TDAQ system and the DCS has been built at Fermilab's Feynman Computing Center. In this article, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-BRA-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Predicting Potentially Problematic VMAT Treatment Plans Before Patient Specific QA Measurements

Purpose: Several promising IMRT QA tools have been developed in recent years to combat problems found in the lack of sensitivity in planar dose measurements analyzed using consensus gamma analysis criteria. The increased complexity and added information with such devices adds not only increased time, but new challenges in determining endpoints for pass/fail criteria. Using a large cohort of previously measured planar IMRT QA data, it may be possible to correlate potentially problematic plans with calculated plan metrics that can be done a priori, such that these tools can be used only in clinically relevant situations. Methods: 90 previously measured, clinically delivered VMAT plans were exported in DICOM RT format. Using a Matlab program, plan metrics were computed based on a previously developed set of equations (Du et al. 2014). These metrics included MU-weighted beam irregularity, which quantifies an MLC shape’s deviation from that of a circle. Machine delivery parameters such as MU delivered per degree and leaf movement in millimeters per MU were also calculated. Based on a previous analysis of 394 IMRT QA measurements, a “failing” plan was defined as one with less than 85% gamma pass rate when computed at 1% dose difference and 2 mm distance to agreement; 16 of the 90 plans were identified as failing Results: A ROC curve was generated with an AUC of 0.9409. All 16 outliers were detected with a specificity of 85.1% when using a threshold value based on a linear combination of the MU-weighted plan irregularity and the leaf speed in mm/degree (average MU delivered per degree multiplied by average leaf movement in mm per MU). Conclusion: This data supports that potentially problematic VMAT plans can possibly be predicted before measurement by assessing the MU-weighted irregularity of the MLC shapes combined with the averaged leaf speed of the MLC.

60 APPLIED LIFE SCIENCES↗

Landslide hazard mapping with selected dominant factors: A study case of Penang Island, Malaysia

Landslide is one of the destructive natural geohazards in Malaysia. In addition to rainfall as triggering factos for landslide in Malaysia, topographical and geological factors play important role in the landslide susceptibility analysis. Conventional topographic factors such as elevation, slope angle, slope aspect, plan curvature and profile curvature have been considered as landslide causative factors in many research works. However, other topographic factors such as diagonal length, surface area, surface roughness and rugosity have not been considered, especially for the research work in landslide hazard analysis in Malaysia. This paper presents landslide hazard mapping using Frequency Ratio (FR) and the study area is Penang Island of Malaysia. Frequency ratio approach is a variant of probabilistic method that is based on the observed relationships between the distribution of landslides and each landslide-causative factor. Landslide hazard map of Penang Island is produced by considering twenty-two (22) landslide causative factors. Among these twenty-two (22) factors, fourteen (14) factors are topographic factors. They are elevation, slope gradient, slope aspect, plan curvature, profile curvature, general curvature, tangential curvature, longitudinal curvature, cross section curvature, total curvature, diagonal length, surface area, surface roughness and rugosity. These topographic factors are extracted from the digital elevation model of Penang Island. The other eight (8) non-topographic factors considered are land cover, vegetation cover, distance from road, distance from stream, distance from fault line, geology, soil texture and rainfall precipitation. After considering all twenty-two factors for landslide hazard mapping, the analysis is repeated with fourteen dominant factors which are selected from the twenty-two factors. Landslide hazard map was segregated into four categories of risks, i.e. Highly hazardous area, Hazardous area, Moderately hazardous area and Not hazardous area. The maps was assessed using ROC (Rate of Curve) based on the area under the curve method (AUC). The result indicates an increase of accuracy from 77.76% (with all 22 factors) to 79.00% (with 14 dominant factors) in the prediction of landslide occurrence.

58 GEOSCIENCES↗

Veridical data science

Building and expanding on principles of statistics, machine learning, and scientific inquiry, we propose the predictability, computability, and stability (PCS) framework for veridical data science. Our framework, composed of both a workflow and documentation, aims to provide responsible, reliable, reproducible, and transparent results across the data science life cycle. The PCS workflow uses predictability as a reality check and considers the importance of computation in data collection/storage and algorithm design. It augments predictability and computability with an overarching stability principle. Stability expands on statistical uncertainty considerations to assess how human judgment calls impact data results through data and model/algorithm perturbations. As part of the PCS workflow, we develop PCS inference procedures, namely PCS perturbation intervals and PCS hypothesis testing, to investigate the stability of data results relative to problem formulation, data cleaning, modeling decisions, and interpretations. We illustrate PCS inference through neuroscience and genomics projects of our own and others. Moreover, we demonstrate its favorable performance over existing methods in terms of receiver operating characteristic (ROC) curves in high-dimensional, sparse linear model simulations, including a wide range of misspecified models. Finally, we propose PCS documentation based on R Markdown or Jupyter Notebook, with publicly available, reproducible codes and narratives to back up human choices made throughout an analysis. The PCS workflow and documentation are demonstrated in a genomics case study available on Zenodo.

97 MATHEMATICS AND COMPUTING↗

Improved exome prioritization of disease genes through cross-species phenotype comparison

Numerous new disease-gene associations have been identified by whole-exome sequencing studies in the last few years. However, many cases remain unsolved due to the sheer number of candidate variants remaining after common filtering strategies such as removing low quality and common variants and those deemed unlikely to be pathogenic (non-coding, not affecting splicing, synonymous or missense mutations annotated as non-pathogenic by prediction algorithms). The observation that each of our genomes contains about 100 genuine loss of function variants with ~20 genes completely inactivated makes identification of the causative mutation problematic when using these strategies alone. In some cases it may be possible to use multiple affected individuals, linkage data, identity-by-descent inference, de novo heterozygous mutations from trio analysis, or prior knowledge of affected pathways to narrow down to the causative variant. In cases where this is not possible or has proven unsuccessful we propose using the wealth of genotype to phenotype data that already exists from model organism studies to assess the potential impact of these exome variants. Here, we introduce PHenotypic Interpretation of Variants in Exomes (PHIVE), an algorithm that integrates the calculation of phenotype similarity between human diseases and genetically modified mouse models with evaluation of the variants according to allele frequency, pathogenicity and mode of inheritance approaches in our Exomiser tool. Large-scale validation of PHIVE analysis using 100,000 exomes containing known mutations demonstrated a substantial improvement (up to 54.1 fold) over purely variant-based (frequency and pathogenicity) methods with the correct gene recalled as the top hit in up to 83% of samples, corresponding to an area under the ROC curve of over 95%. We conclude that incorporation of phenotype data can play a vital role in translational bioinformatics and propose that exome sequencing projects should systematically capture clinical phenotypes to take advantage of the strategy presented here.

59 BASIC BIOLOGICAL SCIENCES↗