Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phase I Final Report

Explore the source record for details and available documents.

36 MATERIALS SCIENCE↗

Gamma Spectroscopy

Gamma Spectroscopy, or the identification of radio-isotopes based on energy, is extraordinarily useful in the Nuclear field. High Purity German (HPGe) gamma detectors along with Sodium Iodine (NaI) gamma detectors are commonly used to identify possible contamination and determine enrichments, among many other applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cherenkov-type three-dimensional breakdown behavior of the Bloch-point domain wall motion in the cylindrical nanowire

A three-dimensional breakdown behavior of the magnetic Bloch-point domain wall (BP-DW) propagation was investigated in a ferromagnetic nanowire with the variation of the external magnetic field by means of micromagnetic simulation. As magnetic field strength increases up to a threshold value, the BP-DW velocity approaches a critical phase velocity of the spontaneously emitting spin wave (SW), where a Cherenkov-type DW breakdown phenomenon is observed originating from an interaction between the spontaneously emitting SW and the BP-DW. It is found that the velocity of the BP-DW approaches a maximum value (~2000 m/s) due to the intrinsic reversal time of a BP spin texture. This suggests that although cylindrical ferromagnetic nanowires might be free from the two-dimensional Walker breakdown phenomenon, there exists a Cherenkov-type three-dimensional breakdown behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the parity-violating asymmetry in the 𝑁 → Δ transition at low 𝑄 2

Here, we report the measurement of the parity-violating asymmetry in the 𝑁 → Δ transition via the 𝑒 − + 𝑝 → 𝑒 − + Δ + reaction at two different kinematic points with low four-momentum transfer 𝑄 2 . Measurements were made with incident electron beam energies of 0.877 and 1.16 GeV, corresponding to 𝑄 2 values of 0.0111 and 0.0208 (GeV/c) 2 , respectively. These measurements put constraints on a low-energy constant in the weak Lagrangian, 𝑑 Δ , corresponding to a parity-violating electric-dipole transition matrix element. This matrix element has been shown to be large in the strangeness-changing channel, via weak hyperon decays such as Σ + → 𝑝⁢𝛾. The measurements reported here constrain 𝑑 Δ in the strangeness-conserving channel. The final asymmetries were −0.65±1.00⁢(stat.)±1.02⁢(syst.) ppm (parts per million) for 0.877 GeV and −3.59±0.82⁢(stat.)±1.33⁢(syst.) ppm for 1.16 GeV. With these results we deduce a small value for 𝑑 Δ , consistent with zero, in the strangeness-conserving channel, in contrast to the large value for 𝑑 Δ previously reported in the strangeness-changing channel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parity-violating inelastic electron-proton scattering at low Q 2 above the resonance region

We report the measurement of the parity-violating asymmetry for the inelastic scattering of electrons from the proton, at $Q^2 = 0.082$ GeV$^2$ and $ W = 2.23$ GeV, above the resonance region. The result $A_{\rm Inel} = - 13.5 \pm 2.0 ({\rm stat}) \pm 3.9 ({\rm syst})$ ppm agrees with theoretical calculations, and helps to validate the modeling of the $\gamma Z$ interference structure functions $F_1^{\gamma Z}$ and $F_2^{\gamma Z}$ used in those calculations, which are also used for determination of the two-boson exchange box diagram ($\Box_{\gamma Z}$) contribution to parity-violating elastic scattering measurements. A positive parity-violating asymmetry for inclusive $\pi^-$ production was observed, as well as positive beam-normal single-spin asymmetry for scattered electrons and a negative beam-normal single-spin asymmetry for inclusive $\pi^-$ production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Angular distribution of 𝛾 rays from a neutron-induced 𝑝-wave resonance of 132 Xe

A neutron-energy dependent angular distribution was measured for individual 𝛾 rays from the 3.2 eV 𝑝-wave resonance of 131 Xe+⁢𝑛, that shows enhanced parity violation owing to a mixing between 𝑠- and 𝑝-wave amplitudes. The 𝛾-ray transitions from the 𝑝-wave resonance were identified, and the angular distribution with respect to the neutron momentum was evaluated as a function of the neutron energy for 7132 keV 𝛾 rays, which correspond to a transition to the 1807 keV excited state of 132 Xe. The angular distribution is considered to originate from the interference between 𝑠- and 𝑝-wave amplitudes, and will provide a basis for a quantitative understanding of the enhancement mechanism of the fundamental parity violation in compound nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QED nuclear medium effects at EIC energies

Here, we present the first calculation of quantum electrodynamics (QED) nuclear medium effects under the experimental conditions of future Electron-Ion Collider (EIC) experiments. Our work offers numerical estimates, particularly in the context of inclusive deep inelastic scattering on a $^{208}_{82}$Pb nucleus. While prior studies have predominantly focused on elastic scattering, our investigation extends to the more complex scenarios of inelastic processes within a nuclear medium. Our findings suggest that the cross section corrections due to QED nuclear medium effects could be substantial, reaching or exceeding the level of experimental precision. This work further compares the effects of single rescattering events with those of multiple rescatterings, as particles travel the nuclear volume. We estimate the dominant source of the uncertainties associated with our formalism by varying the scale of the atomic physics where the screening of the electric field of the nucleus happens. This calculation not only contributes to the understanding of QED nuclear medium effects, but also offers a path to a more precise extraction of the process-independent nonperturbative structure of nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical Bit-Error Model of NAND Flash Memories for Dosimetry Application

In this work, we provide an analytical model for the total ionizing dose (TID) effects on the bit error statistics of commercial flash memory chips. We have validated the model with experimental data collected by irradiating several commercial NAND flash memory chips from different technology nodes. We find that our analytical model can project bit errors at higher TID values (~ 20 krad(Si)) from measured data at lower TID values (<1 krad(Si)). Based on our model and the measured data, we have formulated basic design rules for using a commercial flash memory chip as a dosimeter. We discuss the impact of NAND chip-to-chip variability, noise margin and the intrinsic errors on the dosimeter design using detailed experimentation.

3-D NAND↗