Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiological Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Oral CXCR4 Inhibitor X4-136 Improves Tumor Control and Reduces Toxicity in Cervical Cancer Treated With Radiation Therapy and Concurrent Chemotherapy

Cervical cancer is a global health problem. Despite the growth of prevention programs, there is an important need to improve the effectiveness of treatment for patients with invasive, locally advanced disease. In this study we examined (1) the efficacy of radiation therapy (RT) with cisplatin (RTCT) and an orally administered CXCR4 inhibitor suitable for clinical use, X4-136; (2) biomarkers of response to RTCT and X4-136; and (3) intestinal toxicity from RTCT and X4-136.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Special issue on the 24th workshop on MHD stability control

We report the 24th workshop on magnetohydrodynamic (MHD) stability control was held on the Columbia University campus 28–30th October, 2019. The purpose of this annual workshop is to discuss cutting edge results and form future plans for active control of MHD instabilities in magnetic confinement fusion reactor concepts. The program was organized by an international committee of representatives from Auburn University (USA), Columbia University (USA), Massachusetts Institute of Technology (USA), Princeton Plasma Physics Laboratory (USA), Princeton University (USA), Tottori University (Japan), Kyoto Institute of Technology (Japan), National Institute of Radiological Sciences (Japan), National Institute for Fusion Science (Japan), Institutes of Physical Science—Chinese Academy of Sciences (People's Republic of China), and Consiglio Nazionale delle Ricerche (Italian Republic). Dr Gerald Navratil and Columbia University, in particular, were responsible for organizing and hosting the meeting on their beautiful Morningside Heights campus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fractionated Low-Dose Radiation Induces Long-Lasting Inflammatory Responses in the Hippocampal Stem Cell Niche

Despite major technical advances in hippocampus-sparing radiation therapy, radiation-induced injury to the neural stem cell compartment may affect neurocognitive functions. In the brain, glial cells modulate neuronal functions and are major mediators of neuroinflammation. In a preclinical mouse model with fractionated low-dose radiation (LDR), the complex response to radiation-induced injury was analyzed in the hippocampal stem cell compartment over a period of 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laboratory Analysis for Radiological Events

Presentation for an International Atomic Energy Agency sponsored workshop on Consequence Management (virtual). Presentation sponsored by DOE NA-81

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FLASH Dose Rate Helium Ion Beams: First In Vitro Investigations

To establish and investigate the effects of dose, linear energy transfer (LET), and O{sub 2} concentration on biologic response to ultrahigh dose rate (uHDR; FLASH) helium ion beams compared with standard dose rate (SDR) irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of Synthetic Data for a Radiation Detection Algorithm Competition

This paper details the generation of synthetic radiation data using large-scale Monte Carlo transport models to evaluate radiation search detection algorithms. Modular 3-D Monte Carlo models spanning multiple city blocks were constructed, loosely based on downtown Knoxville, TN, containing buildings composed of multiple materials (brick, granite, and concrete), sidewalks, a four-lane road, side streets, parking lots, and grassy fields. Background and simulated source detector response calculations from these models were used to create synthetic list mode data sets for a 2"×4"×16" NaI(Tl) detector moving through a city street at a constant speed. For the background simulations, major isotopes were computed individually so that background composition and variability could be computed efficiently outside Monte Carlo. The source detector response included six simulated sources placed at 15 source locations. Detector response was developed to be periodic through the city street so that a detector path could begin at one end of the model and wrap around to the other. This framework allowed for the creation of diverse data sets, each with its own unique background and simulated source detector response. Synthetic data allows for high-quality labels, which are useful in developing data-driven radiation detection algorithms. This methodology was used to create synthetic data sets which were released as part of a public data competition to spur the development of new radiation detection algorithms for radiological search applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INTEGRATION OF THE H3D-M400 DETECTOR AND SPOT ROBOT FOR AUTOMATED AREA SURVEY MISSIONS

Office of Nuclear Smuggling Detection and Deterrence (NSDD) is charged to identify and develop technologies to detect, disrupt, and investigate smuggling of radiological and nuclear materials •Border protection involves primary inspections using Radiation Portal Monitors (RPM), complimented with secondary and area survey inspections, usually performed manually using portable radiation detectors (PRDs) -RPM rely on fast technologies which provide quick scans of passing cargo/vehicles -Secondary inspections rely on trained, field deployed staff responsible for additional interdiction of screened cargo/vehicle putting them in potentially hazardous environment -Area survey inspections rely on trained, field deployed staff responsible for scanning and identifying presence of radiation while patrolling through a facility or public space •This project explores the use of technology which could reduce risks to field inspectors and add efficiency •The work presented here is a proof of principle of detector-robot integration to perform area survey inspections

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗