Search NASA⌕ Search

SEARCH · Search NASA

Results for “Raman frequencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Optical Stark effect in the four-wave mixing and stimulated Raman spectra of N2

The influence of the optical Stark effect on spectral line shapes in four-wave-mixing Raman spectroscopy (FWMRS) and stimulated Raman spectroscopy (SRS) is investigated experimentally and theoretically. Using an experimental setup capable of rapid alternation between the simultaneous measurement of coherent Stokes Raman spectroscopy and inverse Raman spectroscopy at low and high intensities, together with a sophisticated frequency reference scheme, it was possible to perform a rather direct comparison between Stark-broadened and non-Stark-broadened spectra of both classes of Raman spectroscopies. The results demonstrate that SRS spectra show more Stark shift and broadening than their FWMRS counterparts. A discrepancy with theoretical results is pointed out, and an attempt is made to explain it.

Moosmuller, H.↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.↗

Residual stress analysis of aluminum nitride piezoelectric micromachined ultrasonic transducers using Raman spectroscopy

In this study, the Raman biaxial stress coefficients K II and strain-free phonon frequencies ω 0 have been determined for the E 2 (low), E 2 (high), and A 1 (LO) phonon modes of aluminum nitride, AlN, using both experimental and theoretical approaches. The E 2 (high) mode of AlN is recommended for the residual stress analysis of AlN due to its high sensitivity and the largest signal-to-noise ratio among the studied modes. The E 2 (high) Raman biaxial stress coefficient of ₋3.8 cm₋1/GPa and strain-free phonon frequency of 656.68 cm ₋1 were then applied to perform both macroscopic and microscopic stress mappings. For macroscopic stress evaluation, the spatial variation of residual stress was measured across an AlN-on-Si wafer prepared by sputter deposition. A cross-wafer variation in residual stress of ~150 MPa was observed regardless of the average stress state of the film. Microscopic stress evaluation was performed on AlN piezoelectric micromachined ultrasonic transducers (pMUTs) with submicrometer spatial resolution. These measurements were used to assess the effect of device fabrication on residual stress distribution in an individual pMUT and the effect of residual stress on the resonance frequency. At ~20 μm directly outside the outer edge of the pMUT electrode, a large lateral spatial variation in residual stress of ~100 MPa was measured, highlighting the impact of metallization structures on residual stress in the AlN film.

36 MATERIALS SCIENCE↗

Resonance Raman Study of Shell Morphology in InP/ZnSe/ZnS Core/Shell/Shell Nanocrystals

Resonance Raman spectra and absolute cross sections of InP/ZnSe/ZnS core/shell/shell nanocrystals have been obtained at excitation wavelengths of 501.7, 457.9, and 410 nm. Eight different structures having nearly the same lowest excitonic absorption wavelength but significantly different stoichiometries are compared. The Raman spectra show phonon features attributable to both the InP core and the ZnSe shell. The largest differences among the structures are seen in the ZnSe phonon region by using excitation at 457.9 nm, on the low-energy edge of the absorption features having significant contributions from the ZnSe shell. Here, structures that are nearly stoichiometric (In:P ratio ≈1.0) show a sharp, strongly polarized peak near the bulk ZnSe phonon frequency (~250 cm –1 ) and a weak lower-frequency shoulder with a higher depolarization ratio. Structures having excess indium show a stronger low-frequency shoulder near 225 cm –1 and lower integrated Raman intensities throughout the ZnSe phonon region. These changes are attributed to the presence of indium atoms in the ZnSe shell. Furthermore, these results support a previous assignment of a slow rise component in the time-resolved photoluminescence spectra of nonstoichiometric structures to transient trapping of holes at indium defects in the shell.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving Rare-Earth Mineral Separation with Insights from Molecular Recognition: Functionalized Hydroxamic Acid Adsorption onto Bastnäsite and Calcite

Enhancing the separation of rare-earth elements (REEs) from gangue materials in mined ores requires an understanding of the fundamental interactions driving the adsorption of collector ligands onto mineral interfaces. In this work, we examine five functionalized hydroxamic acid ligands as potential collectors for the REE-containing bastnäsite mineral in froth flotation using density functional theory calculations and a suite of surface-sensitive analytical spectroscopies. These include vibrational sum frequency generation, attenuated total reflectance Fourier transform infrared, Raman, and X-ray photoelectron spectroscopies. Differences in the chemical makeup of these ligands on well-defined bastnäsite and calcite surfaces allow for a systematic relationship connecting the structure to adsorption activity to be framed in the context of interfacial molecular recognition. Here we show how the intramolecular hydrogen bonding of adsorbed ligands requires the inclusion of explicit water solvent molecules to correctly map energetic and structural trends measured by experiments. We anticipate that the results and insights from this work will motivate and inform the design of improved flotation collectors for REE ores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal structure of silver pentazolates AgN 5 and AgN 6

Silver pentazolate, a high energy density compound containing the cyclo-N 5 – anion, has recently been synthesized under ambient conditions. However, due to high sensitivity to irradiation, its crystal structure has not been determined. In this work, silver–nitrogen crystalline compounds under ambient conditions and at high pressures, up to 100 GPa, are predicted and characterized by performing first-principles evolutionary crystal structure searching with variable stoichiometry. It is found that newly discovered AgN 5 and AgN 6 are the only thermodynamically stable silver–nitrogen compounds at pressures between 42 and 80 GPa. In contrast to AgN 5 , the pentazolate AgN 6 compound contains N 2 diatomic molecules in addition to cyclo-N 5 – . These AgN 5 and AgN 6 crystals are metastable under ambient conditions with positive formation enthalpies of 54.95 kJ mol –1 and 46.24 kJ mol –1 , respectively. Here, the underlying cause of the stability of cyclo-N 5 – silver pentazolates is the enhanced aromaticity enabled by the charge transfer from silver atoms to nitrogen rings. To aid in the experimental identification of these materials, calculated Raman spectra are reported at ambient pressure: the frequencies of N 5 – vibrational modes of AgN 5 are in good agreement with those measured in the experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Producing entangled photon pairs and quantum squeezed states in plasmas

Plasma is capable of mediating the conversion of two pump photons into two different photons through a relativistic four-wave mixing nonlinearity. Spontaneously created photon pairs are emitted at symmetric angles with respect to the colinear pump direction, and the emission rate is largest if they have identical frequency. Thus, two orthogonally polarized pumps can produce polarization-entangled photon pairs through a millimeter-long homogeneous plasma. Here, the noise from Raman scattering can be avoided if the pump detuning differs from twice the plasma frequency. However, pump detuning exactly equal to twice the plasma frequency can significantly enhance the interaction rate, which allows for the production of strong two-mode squeezed states. Remarkably, the amplified noise from Raman scattering are correlated and hence can be suppressed in one of the output quadratures, thereby maintaining the squeezing magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frequency conversion system

Laser diode pumped mid-IR wavelength sources include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

High power pumped mid-IR wavelength systems using nonlinear frequency mixing (NFM) devices

Laser diode pumped mid-IR wavelength systems include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

High power pumped MID-IR wavelength devices using nonlinear frequency mixing (NFM)

Laser diode pumped mid-IR wavelength sources include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

Vibrational and electronic properties of Np 2 O 5 from experimental spectroscopy and first principles calculations

High-valence actinide oxides are critical to understanding the behavior of 5f-electrons, yet their structural and electronic properties remain poorly understood due to challenges in synthesis and handling. We report the first Raman spectroscopic study of single-crystalline Np 2 O 5 and the first scanning tunneling spectroscopy (STS) measurement on any neptunium-containing material. Hydrothermally synthesized crystals were structurally verified by X-ray diffraction. Raman spectra revealed sharply resolved vibrational features, including previously unreported low-frequency modes. STS measurements revealed a band gap of 1.5 eV. Density functional theory (DFT) enables vibrational mode assignments, reveals neptunium-dominated low-frequency phonons, oxygen-dominated high-frequency modes, and predicts an indirect band gap of 1.68 eV. This predicted value is in excellent agreement with the experimentally measured STS gap. This combined Raman, DFT, and STS approach provides a robust framework for correlating lattice dynamics and electronic structure in actinide materials, providing benchmark data for Np 2 O 5 , and opening new avenues for probing structure–property relationships in complex f-electron materials.

36 - MATERIALS SCIENCE↗

Using Cloud Top Pressures Derived from Raman Scattering in the UV for the OMI Total Column Ozone Retrievals

The OMI cloud pressure product is necessary for accounting for cloud effects on the mission- critical total ozone product. One of the OM1 cloud pressure algorithms uses UV measurements to derive cloud pressures from the high frequency structure of top- of-atmosphere reflectance caused by rotational Raman scattering (RRS) in the atmosphere. RRS results in filling-in of Fraunhofer lines in the backscatter UV spectra (also known as the Ring effect). The magnitude of filling-in of the Fraunhofer lines is roughly proportional to the average number of solar photon scatterings in the atmosphere above the clouds. This property of RRS is used to deduce an effective cloud pressure. The cloud pressure algorithm retrieves the cloud pressure and cloud fraction using a concept of the Mixed Lambert Equivalent Reflectivity (MLER) also used for the TOMS-V8 OM1 total column ozone algorithm. Currently, this OMI total column ozone algorithm utilizes information about cloud top pressures from a climatology based on IR measurements. The IR-derived cloud top pressure is known to be lower than UV-derived cloud top pressure because UV radiation penetrates clouds deeper than IR radiation. That is why the UV-derived cloud pressure may be more consistent withthe total ozone algorithm. We estimate total column ozone differences caused by replacing the cloud pressure climatology with cloud pressures retrieved from GOME data same as used for retrieval of ozone.

Joiner, J.↗

Defect-induced phonon-resonant scattering and its influence on thermal transport of irradiated thorium-dioxide

Thermal transport in proton irradiated thorium-dioxide (ThO 2 ) is investigated. Using a combination of experiments and first-principles computational framework, the role of lattice defects on thermal conductivity is analyzed. A resonant-phonon scattering mechanism beyond the traditionally considered Rayleigh scattering is found to significantly influence low-temperature thermal transport in the presence of irradiation-induced point defects. The existence of localized phonon modes associated with irradiation-induced defects is suggested by the inability of the first-principles based thermal conductivity model—which considers only three-phonon interactions and phonon-defects scattering using the Tamura formalism—to predict the experimental results, unless a resonant scattering mechanism is included. The emergence of additional peaks in the Raman spectra in the proximity of phonon-resonant frequency provides further evidence for the existence of localized modes. Coupled with a microstructure evolution model, this analysis enables more accurate analysis for contrasting the contributions of different phonon scattering mechanisms across all irradiation doses and temperatures.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preventing Raman Lasing in High-Q WGM Resonators

A generic design has been conceived to suppress the Raman effect in whispering- gallery-mode (WGM) optical resonators that have high values of the resonance quality factor (Q). Although it is possible to exploit the Raman effect (even striving to maximize the Raman gain to obtain Raman lasing), the present innovation is intended to satisfy a need that arises in applications in which the Raman effect inhibits the realization of the full potential of WGM resonators as frequency-selection components. Heretofore, in such applications, it has been necessary to operate high-Q WGM resonators at unattractively low power levels to prevent Raman lasing. (The Raman-lasing thresholds of WGM optical resonators are very low and are approximately proportional to Q(sup -2)). Heretofore, two ways of preventing Raman lasting at high power levels have been known, but both entail significant disadvantages: A resonator can be designed so that the optical field is spread over a relatively large mode volume to bring the power density below the threshold. For any given combination of Q and power level, there is certain mode volume wherein Raman lasing does not start. Unfortunately, a resonator that has a large mode volume also has a high spectral density, which is undesirable in a typical photonic application. A resonator can be cooled to the temperature of liquid helium, where the Raman spectrum is narrower and, therefore, the Raman gain is lower. However, liquid-helium cooling is inconvenient. The present design overcomes these disadvantages, making it possible to operate a low-spectral-density (even a single-mode) WGM resonator at a relatively high power level at room temperature, without risk of Raman lasing.

Savchenkov, Anatoliy↗

Exploring Mixed Ionic–Electronic-Conducting PVA/PEDOT:PSS Hydrogels as Channel Materials for Organic Electrochemical Transistors

Here, we report the preparation and evaluation of PVA/PEDOT:PSS-conducting hydrogels working as channel materials for OECT applications, focusing on the understanding of their charge transport and transfer properties. Our conducting hydrogels are based on crosslinked PVA with PEDOT:PSS interacting via hydrogen bonding and exhibit an excellent swelling ratio of ~180–200% w/w. Our electrochemical impedance studies indicate that the charge transport and transfer processes at the channel material based on conducting hydrogels are not trivial compared to conducting polymeric films. The most relevant feature is that the ionic transport through the swollen hydrogel is clearly different from the transport through the solution, and the charge transfer and diffusion processes govern the low-frequency regime. In addition, we have performed in operando Raman spectroscopy analyses in the OECT devices supported by first-principle computational simulations corroborating the doping/de-doping processes under different applied gate voltages. The maximum transconductance (gm~1.05 μS) and maximum volumetric capacitance (C*~2.3 F.cm -3 ) values indicate that these conducting hydrogels can be promising candidates as channel materials for OECT devices.

36 MATERIALS SCIENCE↗

Polarization Maintaining, Very-Large-Mode Area, Er Fiber Amplifier for High Energy Pulses at 1572.3 nm

We demonstrate the first polarization maintaining, very-large-mode-area Er-doped fiber amplifier with ~1000 square micron effective area. The amplifier is core pumped by a Raman fiber laser and is used to generate single frequency one microsecond pulses with pulse energy of 368 microJoules, M2 of 1.1, and polarization extinction greater than 20 dB. The amplifier operates at 1572.3 nm, a wavelength useful for trace atmospheric CO2 detection.

solid-state laser↗