Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ramp control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

U 3 Si 2 and UO 2 composites densified by spark plasma sintering for accident-tolerant fuels

This work reports the synthesis and characterization of the U 3 Si 2 and UO 2 composites sintered by spark plasma sintering (SPS) with controlled microstructures for accident-tolerant fuel application. The U 3 Si 2 and UO 2 composites with different silicide and oxide ratios were synthesized by SPS at temperatures from 1000 to 1300 °C for 5 minutes. The microstructure and phase composition of the SPS densified composite fuels were characterized with scanning electron microscopy, X-ray diffraction (XRD), and energy dispersed spectroscopy (EDS). A systematic study of the thermal and mechanical properties was conducted using microhardness testing and laser flash apparatus, along with oxidation resistance measurements using thermogravimetric analysis (TGA). The results show that the synthesis of composite fuels can be achieved with a 90% theoretical density (TD) at 1000 °C and over 95% TD when sintered at 1300 °C. XRD and EDS results confirmed that the dominant phases in the composites are U 3 Si 2 and UO 2 . Improved physical density generally leads to improved hardness, fracture toughness, thermal diffusivity, and onset temperature during the oxidation process. U 3 Si 2 was found to play a dominant role in determining the mechanical and oxidation properties of the composite fuels, whereas UO 2 had a more important impact on controlling the thermal diffusivity of the composites. The composite with 50 wt% UO 2 sintered at 1300 °C displayed the onset oxidation temperature of 500 °C by dynamic oxidation testing using TGA at a ramp degree of 10 °C/min. The composite also achieved a high fracture toughness of ~3.5 MPa m ½ . Finally, these results highlight the potential of composite fuel forms densified by SPS with simultaneously enhanced fissile element density, fracture toughness, thermal transport properties, and oxidation resistance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗

Reconceptualizing Off-Ramps as a Tool of U.S.-China Escalation Management

Great power rivalry, at any point on the competition spectrum, involves assessments of risks and decisions on where to take them. Assessing risk versus reward is also integral to the decision to cooperate in the form of arrangements like arms control. As Donald Brennan wrote more than sixty years ago, the value in arms control lies in whether it “reduce[s] the hazards of the present armament policies by a factor greater than the amount of risk introduced by the control measures themselves.” 2 States can assume in peacetime the risks inherent in cooperating with an adversary, to attempt to mitigate risks likely to arise in crisis or conflict. Or they can choose to forgo cooperation and assume risks later, which will complicate their ability to manage crises, war, and war termination.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

CO 2 Methanation on Cu-Cluster Decorated Zirconia Supports with Different Morphology: A Combined Experimental In Situ GIXANES/GISAXS, Ex Situ XPS and Theoretical DFT Study

We report that subnanometer copper tetramer-zirconia catalysts turn out to be highly efficient for CO 2 hydrogenation and its conversion to methane. The cluster size and substrate morphology are controlled to optimize the catalytic performance. The two types of zirconia supports investigated are prepared by atomic layer deposition (~ 3 nm thick film) and supersonic cluster beam deposition (nanostructured film, ~ 100 nm thick). The substrate plays a crucial role in determining the activity of the catalyst as well as its cyclability over repeated thermal ramps. A temperature-programmed reaction combined with in situ X-ray characterization reveals the correlation between the evolution in the oxidation state and catalytic activity. Ex situ photoelectron spectroscopy indicates Cu clusters with stronger interactions with the nanostructured film, which can be the cause for the higher activity of this catalyst. Density functional theory calculations based on the Cu 4 O 2 cluster supported on a ZrOx subunit reveal low activation barriers and provide mechanism for CO 2 hydrogenation and its conversion to methane. Altogether, the results show a new way to tune the catalytic activity of CO 2 hydrogenation catalysts through controlling the morphology of the support at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time dependent model for non-inductive ECH X-I current ramp-up for SHPD tokamak facility

Non-inductive (NI) plasma current start-up and ramp-up is an important research topic for spherical tokamak (ST) based reactors and fusion pilot plant (FPP). For a compact FPP, the OH flux availability is highly restricted due to its compact geometry. Efficient fundamental extraordinary mode (X-I) electron cyclotron heating (ECH) current start-up and ramp-up regime was identified for a reactor-like high toroidal magnetic field range which has more than a hundred times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. High current drive efficiency is possible due to the strong X-I fundamental ECH interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. Here, we extend the X-I electron cyclotron current drive (ECCD) investigation to a time dependent model to simulate the non-inductive current ramp-up to 10 MA for the Sustained High-Power Density (SHPD) facility. As the X-I ECCD driven current I EC rises, due to the back EMF driven negative current, the net plasma current Ip rises more slowly with the current resistive time scale. For tokamak confinement time (both L-mode and H-Mode) which tends to rise with I p , a positive feedback results and even with constant applied ECH power, T e0 , I EC , and I p can continue to rise to very high values. However, in a realistic situation, the T e0 rise should saturate due to a number of factors such as enhanced core radiation and increased power loss at high temperature. To simulate this effect, we adopt a maximum T e0 model which would limit the temperature rise to certain T e0 . With this model, we investigated the current ramp-up for various ECH power levels and the maximum T e0 of 15, 20, and 25 keV. We find that while the power required is reduced with increasing T e0 limit due to increased current drive efficiency, the time to reach 10 MA tends to go up due to the reduced plasma resistivity for the higher T e0 limit. We also find for a given Te0 limit, the time to reach 10 MA tends to be reduced by increasing the applied ECH power by over driving the current ramp-up where I EC is driven at significantly higher level than 10 MA. While the current ramp-up time may not be an issue for the steady-state reactor systems, if it is desirable to minimize the current ramp-up time, it is prudent to have a sufficient ECH power for current over-drive and have some T e0 limiting tools such as impurity seeding for enhanced radiation. In conclusion, a well-controlled NI ECH start-up also has a potential of improving the tokamak start-up reliability and avoid run-away electrons while the NI off-axis current drive could enhance MHD stability and plasma performance improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

A trait-based framework for linking microbial communities with carbon transformations under precipitation change

Droughts are common throughout the world. As the climate changes, droughts may become more frequent and intense. Still, scientists are uncertain about how drought will affect the natural world, particularly the bacteria, fungi, and other microbes that live in soils. These tiny life forms are crucial because they control the Earth’s flows of carbon and essential nutrients. Researchers at the University of California, Irvine, and Lawrence Berkeley National Laboratory teamed up to study how the microbiome, or collection of bacteria and fungi in the soil, deals with drought. Since 2007, the researchers have used shelters with retractable roofs to prevent nearly half of normal rainfall from reaching grass and shrub ecosystems, and their soil microbiomes, in Southern California. The study team discovered that microbes have some clever tricks up their sleeve for surviving drought. When growing on dead grass as a food source, microbes ramp up production of specialized chemicals called osmolytes that keep their cells from drying out. But microbes growing on dead shrubs face another problem. Unlike grass, shrub leaves are a lousy food source. To digest and consume shrub leaves, microbes have to exude more enzymes, which act like biochemical chef knives that chop complex leaf molecules into bite-sized pieces. Carbon is the coin of the microbial realm, earned via enzyme action or slurping up dead plant juices. Microbes growing under normal conditions on tasty dead grass have it easy: they can spend most of their carbon currency on growth. With drought, life gets harder as microbes need to pay up for osmolytes and ramp down their growth. It gets worse with shrub leaves because microbes have to multi-task among growth, enzyme secretion, and osmolyte production. When drought hits, microbes on shrub leaves forgo the osmolytes, probably because losing the carbon revenue from enzyme investment would be a deal-breaker for survival. The next question tackled by the researchers asked how the genes controlling microbial lifestyles sort out across the tree of life. Most microbiologists thought these lifestyles would correspond to rather large branches on the tree. But the study team found that in fact, very closely related microbes differ in important and interesting ways. For example, bacteria that have nearly identical housekeeping genes respond distinctively to warming, rainfall, and plant chemistry. As a result, soil microbiomes are much richer in diversity than originally thought. And studying microbial diversity in much greater detail could open up many more possibilities for how microbial life deals with changing environmental conditions. Trying to understand microbial life without the fine details of genetic diversity is like trying to stream Netflix on a dial-up connection. By looking across the landscape, the researchers revealed that microbial diversity is absolutely critical for maintaining the planet’s flows of carbon and nutrients. The study team designed a new technology—microbial cages—for transplanting intact microbiomes. With the cages, the researchers could move microbiomes to novel environments and compare their ability to cycle carbon and nutrients. In some cases, performance tailed off when microbiomes found themselves in a new environment, but in other cases, performance rivaled or even exceeded that of the resident microbiome. And even the low performers eventually caught up to the native microbiomes if given sufficient time. These findings mean that microbiomes—at least in Southern California—may be resilient to climate shifts due to a high diversity of microbial lifestyles. Coping with heat and drought may literally be in their DNA. The last piece of the research puzzle, and a “Holy Grail” for microbial ecologists, is to forecast the behavior of diverse microbiomes. To meet this challenge, the study team developed new theory and computer models. For the first time, these models account for hundreds of different microbes and how their intricate lifestyles cope with drought. The models are starting to connect the tiniest microbes with the global cycles that sustain Earth’s farms, fields, and forests. With that connection, it will be easier for society to plan for a world with more droughts and other climate disruptions.

54 ENVIRONMENTAL SCIENCES↗

Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting

Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

Global Ethanol-Blended-Fuel Vehicle Compatibility Study

The objective of this study is to understand the impact of ethanol-blended fuel at various blending levels (10%, 15%, and 20% vol.) on "in-operation" vehicles built to differing emissions and manufacturing standards around the world. The study focuses on vehicles used in Canada, China, India, Indonesia, Japan, South Korea, and Mexico. Historical experience in the United States and Brazil informs the analysis. The primary study question is: Are vehicles in targeted countries physically and operationally compatible with ethanol blended fuel? For a fuel to be compatible with a vehicle, the fuel must perform its function as part of the integrated fuel-vehicle system, meaning: the car should start easily and drive normally, the fuel should not cause catastrophic fuel system leaks, the fuel should not cause corrosion or degradation of any engine or fuel system components (including emissions control components). The history of E10 use in the United States, beginning in 1978, was evaluated and shows no reliability or operability issues for cars dating back to pre-emissions-control times -- and likely included many cars manufactured in the 1960s. This strongly supports the contention that fuel chemistry and property differences between E0 and E10 are so small that any car made to international standards in the last 50 years will have a very high probability of being fully compatible with E10. This conclusion is supported by the experience in Brazil in the 1970s, where E10 was also introduced, and ethanol blending for conventional cars rapidly ramped up to even higher blend levels. A limited number of fuel system and component manufacturers supply the global market, including Bosch, Continental, Denso, Delphi, and Visteon. To reduce complexity, ethanol-compatible materials began to be integrated in fuel system designs globally. Fuel systems evolved over the following decades to incorporate ethanol-compatible materials with core subsystem families, such as in-tank fuel pumps used across several global vehicle original equipment manufacturers (OEMs). A similarly compelling case can be made that all cars at the Tier 1 (or equivalent) emissions-control technology level or higher are fully compatible with E15 blends, based on the data evaluated by the U.S. Environmental Protection Agency (EPA) and Ricardo in 2010. For cars at this technology level, the minor differences in fuel chemistry and properties between E10 and E15 are not significant. For E20, studies are not as extensive but are still highly significant. A long-term durability study conducted on mileage accumulation dynamometers presents convincing evidence that Tier 2 technology level cars have materials of construction and engine control authority for compatibility with E20, although this conclusion is not as strong as those drawn for E10 and E15, which are also partly based on real-world experience.

09 BIOMASS FUELS↗