Search NASA⌕ Search

SEARCH · Search NASA

Results for “Receivers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Development of the Generation 3 Particle Pilot Plant Falling Particle Receiver

A falling particle receiver (FPR) has been designed to integrate with the G3P3-USA pilot plant currently being constructed at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories. This receiver integrates several innovative design features including a converging tunnel (SNOUT), an optimized cavity geometry, and a multistage “catch-and-release” trough. Details about the integration of these features and the final G3P3-USA FPR design and construction are described. Ray-tracing models of the FPR utilizing the NSTTF heliostat field are developed leveraging previous modeling efforts using SolTrace. Models demonstrate that at least 1.5 MWth of incident radiative energy can be provided to the FPR on a clear day throughout a typical year in Albuquerque, NM. Spillage fluxes around the periphery of the aperture are within acceptable bounds for the majority of the year. Intercept factors are computed for each utilized heliostat at the Vernal equinox to provide guidance to heliostat operators during operation of the system.

Mills, Brantley↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Selection and Use Considerations for Laser Power Photovoltaic Receivers

III-V PV receivers provide high performance over wide range of application conditions. Operating conditions including irradiance and cell temperature must be accounted for. Very high efficiencies demonstrated for small GaAs devices. Potential for significant future advances in performance, especially for other wavelengths and for cost.

GaAs↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Determining failure properties of as-received and hydrided unirradiated Zircaloy-4 from ring compression tests

An integrated experimental and computational approach was developed to determine the plastic strain at fracture and to investigate the fracture energy of as-received and hydrided unirradiated Zircaloy-4 nuclear cladding tubes in the hoop direction at room temperature from ring compression testing (RCT). This work builds on previous methods in the literature that were developed to obtain the mechanical properties of nuclear cladding before fracture (Young’s modulus, yield stress, and strain-hardening parameters) from experimental RCT results and extends the characterization of this material class to include material failure properties. Furthermore, a ductile damage approach was developed and implemented in a validated finite element model to predict material failure, evaluate fracture energy, and quantify the plastic strain at fracture initiation. The hydrogen content of the Zircaloy-4 specimens was varied up to 610 wppm when the failure became brittle. As expected, increasing hydrogen content caused embrittlement of the Zircaloy-4 samples tested and the plastic strain at fracture and fracture energy to decrease.

36 MATERIALS SCIENCE↗

Whole-tree dormant season nitrogen pools for different species receiving combinations of fertilization and irrigation after one short rotation

Our understanding of the accretion and distribution of tree tissue nitrogen (N) pools across a variety of species and genotypes suitable for short-rotation woody crop (SRWC) production in response to water and N availability remains limited. We measured dormant-season, rotation-length, whole-tree N pools for five tree genotypes from four species (two eastern cottonwood, Populus deltoides Bartr., genotypes; American sycamore, Platanus occidentalis L.; American sweetgum, Liquidambar styraciflua L.; and loblolly pine, Pinus taeda L.) receiving irrigation (I), fertilization (F), their combination (IF), or no resources manipulation (C). Our results demonstrate that foliar nitrogen concentration [N] responded to fertilization but was constrained within genotype-specific ranges and varied temporally. Tree genotypes differed in their composite and component tissue N content (N C ), and these differences mostly reflected tissue mass (i.e., larger components and trees resulted in higher N C ). Resource amendments (I, F, IF) resulted in up to 3.8-fold increases in N C compared with C, which were most pronounced for sycamore and sweetgum with F and IF treatments, respectively. By the end of the rotation, forest stands accumulated 73 to 452 kg N ha –1 in tree tissues with 40 – 78 % distributed aboveground and 22 – 60 % distributed belowground. A critical difference between genotypes was that all hardwoods exhibited larger belowground N distributions than the evergreen conifer. Our results stress the importance of belowground N pools and highlight differences among genotypes. Furthermore, our study underscores valuable information about N pools across genotypes suitable for SRWC production, which can be leveraged to inform fertilization plans and devise sustainable nutrient management as production expands across marginal lands.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

The Plasma Levels and Polymorphisms of Vitronectin Predict Radiation Pneumonitis in Patients With Lung Cancer Receiving Thoracic Radiation Therapy

Our previous findings have identified vitronectin (VTN) as a potential biomarker for radiation pneumonitis (RP) through proteomics and molecular mechanism studies. In a recent study, we further explored associations of plasma level and single nucleotide polymorphisms of VTN with the risk of RP in patients with lung cancer receiving radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 3 Randomized Trial of Topical Steroid Versus Placebo for Prevention of Radiation Dermatitis in Patients With Head and Neck Cancer Receiving Chemoradiation

Radiation dermatitis is one of the most common acute toxicities induced by chemoradiation therapy (CRT) for head and neck cancer (HNC). The benefit of topical steroids in the management of radiation dermatitis is still unclear. This phase 3, multi-institutional, randomized, double-blind, placebo-controlled trial evaluated the efficacy and safety of topical steroids for radiation dermatitis in patients with locally advanced HNC receiving CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling receiver flux of commercial power tower concentrating solar power plants using ray tracing: a round-robin comparison of SolTrace, Solstice, and TieSOL

This study presents a multi-stage, cross-validation comparison of three software packages for Monte Carlo ray tracing (MCRT) applied to central tower concentrating solar power (CSP) systems. The three packages evaluated are: (1) SolTrace, an open-source tool developed by the National Renewable Energy Laboratory (NREL); (2) Solstice, an open-source program created by CNRS-PROMES and Meso-Star, with enhancements for CSP applications (called solsticepy) from the Australian National University; and (3) TieSOL, a commercial software developed by Tietronix. This investigation extends previous ray tracing comparisons by incorporating models of multi-facet heliostats within a commercial-scale solar field, taking into account zoned focal lengths and canting configurations. Receiver flux distributions were compared across the tools using a series of case studies, including single-heliostat scenarios, isolated blocking situations, and comprehensive full-field simulations. The case studies were designed to diagnose differences across the models at varying levels of complexity, and to identify and resolve discrepancies as additional parameters were introduced. Key factors examined in the analysis include sun positions, heliostat location, facet and canting focus, and aimpoint strategies. The comparison aims to improve the accuracy and reliability of these tools while providing benchmark cases for validating future optical modeling tools.

14 SOLAR ENERGY↗

Receiver willingness to participate in off-hour service programs

Service trips, a frequently overlooked segment of urban traffic, represent a disproportionately large share of the negative impacts associated with commercial activity. The reason is that although service trips are less frequent than freight trips, they often take longer and thus occupy a significant share of commercial parking. Demand management programs seeking to move service trips off-hours can potentially reduce congestion and emissions but they have been understudied. Here, this paper describes research conducted to investigate receivers’ willingness to participate in off-hour programs for planned service activity. The research reported in this paper analyzes results from a survey of 189 business establishments in New York City and the Capital Region in New York State using descriptive analyses of the data, and by estimating a discrete choice model to gain insight into how business characteristics influence willingness to participate in off-hour services. To assess the impacts of a hypothetical off-hour services program, the authors applied the discrete choice model, together with service trip attraction models, to quantify the hours of daytime parking that could be eliminated by the proposed program in certain ZIP Codes in New York City and the Albany area. The research conducted led to the identification of numerous policy implications that will help policymakers understand and maximize the potential benefits of implementing off-hour service programs.

99 GENERAL AND MISCELLANEOUS↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated Over-The-Air Neural Receiver Training Using Self-Contrastive Learning

Self-contrastive learning (SCL), a self-supervised learning method, has been shown to improve image and signal classifier accuracies and reduce the training time for neural communications receivers. In particular, prior work has shown that SCL applied as a pre-training step can improve simulated performance of OFDM in 3GPP TDL channel models by reducing the training time of the downstream classification task (demodulation and demapping). In this work a practical implementation demonstrating SCL pre-training using software defined radios (SDRs) is proposed.

Cooke, Corey [ORNL] (ORCID:0000000234263672)↗

Numerical Study of Solar Receiver Tube With Modified Surface Roughness for Enhanced and Selective Absorptivity in Concentrated Solar Power Tower

Abstract Concentrated solar power (CSP) is a reliable renewable energy source that is progressively lowering its cost of energy. However, the heat loss due to reflected and emitted radiation hinders the maximum achievable thermal efficiency for solar receiver tubes on the solar tower. Current solar selective coatings cannot withstand the high temperatures that come with state-of-the-art CSP towers often needing to be recoated soon after initial operation. We intend to use Inconel 718 with different additive manufacturing (AM) practices to construct surfaces that allow for more light-trapping to occur. By adjusting printing parameters, we can tailor a surface to allow for more absorption while diminishing emitted radiation heat loss. By using COMSOL Multiphysics, we can generate these theoretical surfaces to emulate a printed surface, and using the coupled Multiphysics we can simulate how the surface dictates radiation properties. Our results show that by having a rougher surface we can enhance the absorptivity of Inconel 718 (IN718) by 38.8%. We expect this work to transform how solar absorber tubes are manufactured without using selective coatings and supplement the US Department of Energy (DOE) 2030 SunShot Initiative.

14 SOLAR ENERGY↗

Optical Flow Diagnostics of Counter Fluidization of Gravity-Driven Moving Packed Bed for a CSP Receiver Section Featuring Staggered Array of Cylindrical Pins

Particle fluidized beds have the potential to improve the efficiency of heat transfer in concentrated solar receiver furnace for use in next generation concentrated solar power (CSP) plants. This study presents an experimental investigation on the flow characterization of vertically downward moving packed bed with counter fluidization through an array of jets. To control the bubble size and its distribution in the bubbling fluidized bed, an array of cylindrical pin fins was arranged uniformly across the test article. The flow visualization was performed on the surface of transparent glass coated with electrically conductive materials for electrostatic dissipation purposes. The image acquisition was carried out via high-speed camera at a frequency of ~ 1kHz. The acquired images were analyzed in pairs with the help of a modern optical flow algorithm capable of calculating the movement of dense particle flow in the fluidized bed by tracking the light intensity of each predefined window of the frames. A comparison of fluidized beds with plane and pin-finned channels revealed distinct bubble behavior. Pin-finned channels were found to produce a larger number of small-sized bubbles, while plane channels generated fewer but larger bubbles at any given instant. The presence of pin fins was observed to reduce bubble size by preventing bubble merging and splitting larger bubbles when they encountered a pin.

concentrating solar power↗