Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability and Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Scalable Bayesian Physics-Informed Kolmogorov-Arnold Networks

Uncertainty quantification (UQ) plays a pivotal role in scientific machine learning, especially when surrogate models are used to approximate complex systems. Although multilayer perceptions (MLPs) are commonly employed as surrogates, they often suffer from overfitting due to their large number of parameters. Kolmogorov-Arnold networks (KANs) offer an alternative solution with fewer parameters. However, gradient-based inference methods, such as Hamiltonian Monte Carlo (HMC), may result in computational inefficiency when applied to KANs, especially for large-scale datasets, due to the high cost of back-propagation. To address these challenges, we propose a novel approach, combining the dropout Tikhonov ensemble Kalman inversion (DTEKI) with Chebyshev KANs. This gradient-free method effectively mitigates overfitting and enhances numerical stability. In addition, we incorporate the active subspace method to reduce the parameter-space dimensionality, allowing us to improve the accuracy of predictions and obtain more reliable uncertainty estimates. Extensive experiments demonstrate the efficacy of our approach in various test cases, including scenarios with large datasets and high noise levels. Our results show that the new method achieves comparable or better accuracy, much higher efficiency as well as stability compared to HMC, in addition to scalability. Moreover, by leveraging the low-dimensional parameter subspace, our method preserves prediction accuracy while substantially reducing further the computational cost.

97 MATHEMATICS AND COMPUTING↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC↗

Low-nickel cathode chemistry for sustainable and high-energy lithium-ion batteries

The transition to sustainable energy storage demands lithium-ion batteries with high energy density and reduced reliance on critical metals such as nickel (Ni), yet current strategies to increase capacity have largely depended on raising Ni content, leading to escalating supply risks, rising costs and sustainability concerns. More critically, Ni-rich cathodes suffer from rapid electrochemical degradation driven by structural instability, creating an insurmountable trade-off between capacity and cycle life. Here, in this study, we introduce a low-Ni chemistry cathode, Li(Li 0.05 Ni 0.57 Mn 0.31 Co 0.07 )O 2 , with a radial phase integration design that overcomes these limitations, enabling a remarkable Ni usage reduction (Ni < 0.6) while demonstrating high capacity (215 mAh g −1 ) and markedly improved cyclability (~97% retention over 400 cycles) compared to conventional high-Ni cathodes (Ni = 0.8). Advanced X-ray and electron microscopy analyses reveal that the designed cathode exhibits a highly reversible oxygen anionic redox, benefiting from a structurally stable surface and minimizing irreversible phase transitions. Moreover, the integrated structure substantially mitigates lattice strain and improves mechanical stability even under harsh conditions. In conclusion, this advance offers a general design principle for developing next-generation cathodes that combine resource efficiency with long-term electrochemical reliability.

36 MATERIALS SCIENCE↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering in Cyber Resilience with Cyber-Informed Engineering

Engineers have super powers to provide cybersecurity resilience with deterministic engineering solutions and to protect systems from the most catastrophic consequences that a cyber saboteur could cause. Come to this session to learn how to use engineering risk management skills to harden your engineered systems from cyberattacks. Objective 1 Identify what system functions could be digitally induced to cause undesired high-impact consequences. Objective 2 Analyze how loss or instability of digital controls in a subsystem could lead to high-impact consequences. Objective 3 Analyze how loss or instability in the digital connectivity between systems could lead to high-impact consequences. Objective 4 Identify engineering controls which could build resilience by eliminating digital loss or instability pathways or reduce the impact of digital loss or instability. This presentation will introduce Cyber-Informed Engineering, described below, and walk participants through specific engineering use cases to show how engineers can consider the potential for cyber sabotage in their existing system designs and enact deterministic engineering-based controls which eliminate pathways for attack or mitigate specific consequences. A wide variety of application use cases will be considered so that audience members can align the material with familiar engineering applications. CIE is an engineering approach that integrates cyber resilience into the conception, design, build, and operation of any physical system that has digital connectivity, sensors, monitoring, or control. CIE offers the opportunity to use engineering to eliminate or mitigate avenues for cyber attack—starting from the earliest stage of design and continuing throughout the system’s lifecycle. Today, engineers and industrial control system (ICS) technicians build engineered systems with specific goals for safety, reliability, and functionality. While systems engineering includes considerable safety and failure mode analysis, cybersecurity risks are often not specifically addressed—particularly the risks of intentional cyber compromise, exploitation, and misuse. Cyber-Informed Engineering pairs well with traditional cyber defenses and offers an extra designed-in protection to eliminate the most catastrophic consequences which can be realized by an adversary should traditional cyber defenses fail.

42 ENGINEERING↗

Empowering Critical Infrastructure Communication with Secure 5G Private Networks

With the transformational New Radio- Unlicensed (NR-U), 5G network can be operated with unlicensed and shared spectrum. Private 5G networks without any licensed bands, which are both highly expensive and usually available to only large commercial wireless providers, can now be used for a whole range of new applications including smart factories, warehouses, connected cars and drones. 5G’s support of a) massive machine type communication (mMTC) for a large number of connected devices with b) ultra-reliable low latency communication (URLLC) capability when needed, and c) up to 20 times higher data rate with enhanced mobile broadband (eMBB) than previously available, enables new and powerful capabilities in a wireless network. While these capabilities are transformational, necessary security and reliability requirements have to be satisfied when used in critical infrastructure such as factories, power plants, water systems, ports, and other industrial facilities. 5G standards have introduced significant security improvement over 4G/LTE as well as mitigations for new attack surfaces created by changes in the 5G network. This talk will discuss these security improvements and whether they meet the security properties required for mission critical communication over wireless.

5G↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS↗

Developing a Supply Chain Security Program

Amid growing concerns over foreign manufacturing for components and devices deployed in critical energy infrastructure, this research from the national labs will highlight best practices for developing and maintaining a supply chain security program. Tools for asset inventory, tips for developing and maintaining software- and hardware-bills-of-materials (SBOMs and HBOMs), recommended contractual language for vendor agreements, and identification of responsibilities will be shared. We discuss the one-time requirements to enable a successful supply chain security program and the best ways to operationalize this program for maximum impact, including development of robust practices for vulnerability tracking, patch management, and workarounds, with understanding of the reliability and uptime requirements for utilities. The recommendations shared are based on a cyber-informed engineering approach to identification of high-consequence impacts and the engineering controls related to supply chain management that can best mitigate these impacts. This approach allows for prioritization of resources. Additionally, we highlight relative up-front and ongoing costs associated with recommended controls. Viewers will leave with an understanding what a supply chain security program is, and what steps, prioritized for resource-constrained organizations, can build a robust program.

14 SOLAR ENERGY↗

Review of Ultrafast Switching Power Modules: Trends, Challenges, and Technical Solutions

Benefiting from the superior properties of wide-bandgap semiconductor materials, wide-bandgap power devices demonstrate exceptional switching performance, enabling more efficient and compact power electronics systems. However, ultrafast switching poses challenges to the reliability of the system in terms of severe oscillations and voltage overshoot, electromagnetic interference, and increased risk of partial discharge. By developing advanced power module packaging for fast-switching power devices, the above-mentioned challenges can be mitigated at the packaging level, enabling the full utilization of the fast-switching capability of wide-bandgap devices. Meanwhile, such technology also lays the groundwork for packaging next-generation power devices with even higher blocking voltage and faster switching speed. In this paper, a comprehensive review of ultrafast switching power modules has been made, including the benefits and status of ultrafast switching power modules, challenges brought by ultrafast switching, and promising technologies to address these challenges. In addition, future development trends and research gaps are also discussed in this paper. Furthermore, this review can serve as a reference for future wide-bandgap power module packaging design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing technical debt across large-scale control systems

This presentation provides a comprehensive overview of technical debt in the context of control systems for large-scale physics facilities. We will explore its various forms, common causes, and potential consequences on system reliability, maintainability, and upgradability. Drawing on experiences from multiple projects, we will present a range of strategies for proactively managing technical debt, including best practices in design, development, testing, and documentation, as well as reactive approaches for identifying and mitigating existing issues. The presentation will also emphasize the importance of a collaborative approach and the use of modern tools, like fault tracking systems, to ensure the long-term health and success of control systems in our field.

Watts, Adam [Fermilab]↗

Benchmarking optimization methods for materials research: Gradient descent and Bayesian optimization for lithium-ion battery aging diagnostics

Accurate and efficient parameter estimation is essential for battery diagnostics and aging analysis. Here, in this study, we compare two optimization-based approaches—gradient descent and Bayesian optimization—for extracting parameters from differential voltage analysis in lithium-ion batteries. While these techniques are widely used, their relative strengths and limitations for this application are not well understood. The study evaluates the trade-offs between these methods in terms of result quality, computational cost, and reliability within this specific application. The diagnostic results from our battery data suggest adopting gradient descent as an initial method for rapid and efficient analysis, while employing more stable optimization techniques, such as Bayesian optimization, as a verification step to mitigate potential instability. Comparing the two methods provides information on algorithmic choice, while inspiring further discussions on selecting appropriate techniques for specific research tasks.

Zhao, Ziqing [Boston Univ., MA (United States)] (O↗

Environmental DNA as a tool for hydropower impact assessments: current status, special considerations, and future integration

Globally there is an urgent need to find sustainable solutions to balance energy production with the protection of vulnerable species and conservation of biodiversity. This is particularly critical for freshwater ecosystems, habitats, and species that may be impacted by hydropower development and operations needed to meet energy grid demands. Reliable and accurate environmental impact assessments (EIAs) that identify the biological, physical, or social impacts of hydropower are key to ensure biodiversity, ecosystem, and societal sustainability. The analysis of environmental DNA (eDNA) has the potential to transform hydropower EIAs, management and mitigation planning, and decision-making procedures. Further, the incorporation of eDNA surveys into EIAs during both hydropower planning and continued operations may streamline regulatory processes by improving our understanding of potentially impacted biota and habitats and evaluating environmental impacts mitigation. Here, we: (i) highlight current understanding and use of eDNA in freshwater environments; (ii) examine critical considerations for eDNA integration into hydropower EIAs and biological monitoring; (iii) identify knowledge gaps in eDNA analysis and applications unique to hydropower-regulated systems; and (iv) discuss future opportunities to bolster the incorporation of eDNA into hydropower research including regulatory acceptance and public engagement. While we acknowledge that there are several factors that may complicate the broad adoption of eDNA as a tool for assessing the impacts of hydropower, we anticipate that growing confidence in eDNA through hydropower-specific protocols, calibrations, and validations will overcome these inherent uncertainties.

aquatic biodiversity↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

Deployment of Traditional and Hybrid Machine Learning for Critical Heat Flux Prediction in the CTF Thermal-Hydraulics Code

Critical heat flux (CHF) marks the transition from nucleate to film boiling, where heat transfer to the working fluid can rapidly deteriorate. Accurate CHF prediction is essential for efficiency, safety, and preventing equipment damage, particularly in nuclear reactors. Although widely used, empirical correlations frequently exhibit discrepancies when compared to experimental data, limiting their reliability in diverse operational conditions. Traditional machine learning (ML) approaches have demonstrated potential for CHF prediction but often suffer from limited interpretability, data scarcity, and insufficient knowledge of physical principles. Hybrid model approaches, which combine data-driven ML with base models, mitigate these concerns by incorporating prior knowledge of the domain. This study integrates an externally trained purely data-driven ML model and two hybrid models (using the Biasi and Bowring CHF correlations) within the CTF subchannel code via a custom Fortran framework. Performance was evaluated using two validation cases: a subset of the Nuclear Regulatory Commission (NRC) CHF database and the Bennett dryout experiments. In both cases, the hybrid models demonstrated significantly lower error metrics compared to conventional empirical correlations, with the best models often reducing relative error by about 5 percentage points. The pure ML model achieved comparable accuracy, outperforming the hybrid Biasi model in the NRC test case (3.3% versus 5.5% relative error) but exhibiting slightly higher error against the hybrid Bowring model in the Bennett test case (7.7% versus 6.1%). Trend analysis of error parity indicated that ML-based models reduced the tendency for CHF overprediction, improving overall accuracy. These results demonstrate that ML-based CHF models can be effectively integrated into subchannel codes and could potentially increase performance compared to conventional methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗