At least 145 records · Page 8

Demographic Information Incorporated Household Energy Consumption Analysis: Preprint

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Hybrid Classification-Regression Solution for High-Frequency Nonintrusive Load Monitoring

Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.

feature extraction↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Cost of Comfort in Your Home: Peak-Time Energy and Cost Savings from Setpoint Adjustment of Space Heating and Cooling

This poster presents the tradeoff between energy costs and thermal comfort in homes. Residential heating and cooling systems use a thermostat control to maintain a comfortable temperature range, but tighter temperature control leads to higher annual energy costs. We estimate the impact of temperature setpoint adjustment on annual energy costs using a residential building model developed at NREL. We show that increasing the allowable temperature range reduces energy costs in all five of the climate zones in the U.S. Annual costs reduced by about $100, with larger savings in areas with more heating and/or cooling loads.

30 DIRECT ENERGY CONVERSION↗

A Conversation on Standard 90.1-2019

This article presents a roundtable discussion of the new edition of ASHRAE Standard 90.1-2019 Energy Standard for Buildings Except Low-Rise Residential Buildings. It discusses updates to the standard, challenges overcome, and thoughts about the trajectory of future versions of the standard. Contributors include leading members of the Standard 90.1 development committee.

ASHRAE Standard 90.1, ASHRAE, Energy Code↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗