Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The ordnance transfer interrupter: A new type of S & A device

A discussion is given in this paper of a new approach to the Safing and Arming of aerospace ordnance systems interconnected by detonation transfer lines, in which the conventional type of S&A device normally used for this purpose is replaced by a relatively simple electro-mechanical switching device, referred to as an 'Interrupter.' In this approach the Interrupter, which is interposed in the transfer line between the system initiator and output device, is completely passive in that it contains no pyrotechnic devices or materials. Being passive (therefore, non-initiating), the Interrupter is much less hazardous to handle and install, as well as being significantly less complex and costly than conventional S&A devices containing EED's and explosive leads. Details are presented relative to the design, development and qualification, by PS/EDD, of an ordnance transfer Interrupter intended for use on a commercial launch missile. This device, which is capable of simultaneously 'switching' multiple detonation transfer lines, incorporates a rod-type rotary barrier with independent transverse apertures for each transfer line. Barrier actuation is bi-modal, i.e., the barrier can be driven from safe-to-arm or from arm-to-safe positions by independent electro-mechanical actuators. The Interrupter described also features visual and remote status monitoring provisions and, in common with range-approved conventional S&A devices, a pre-flight safety locking mechanism functioned by a removable safing key.

Greenslade, John T.↗

Formal Verification of the AAMP-FV Microcode

This report describes the experiences of Collins Avionics & Communications and SRI International in formally specifying and verifying the microcode in a Rockwell proprietary microprocessor, the AAMP-FV, using the PVS verification system. This project built extensively on earlier experiences using PVS to verify the microcode in the AAMP5, a complex, pipelined microprocessor designed for use in avionics displays and global positioning systems. While the AAMP5 experiment demonstrated the technical feasibility of formal verification of microcode, the steep learning curve encountered left unanswered the question of whether it could be performed at reasonable cost. The AAMP-FV project was conducted to determine whether the experience gained on the AAMP5 project could be used to make formal verification of microcode cost effective for safety-critical and high volume devices.

Miller, Steven P.↗

Air Safety Spinoffs

Weight saving-even a matter of a few pounds-is an important consideration in airplane design and . construction. Boeing saved 200 pounds simply by substituting a new type of compressed gas cylinder on their 747 commercial airliners. For quickly evacuating passengers in the event of a ground emergency the 747 escape chutes allow ' passengers to slide to safety from the two-story height of the cabin deck. The chutes pop out of exitways and are automatically inflated in seconds by compressed air stored in pressure vessels. Boeing's weight saving resulted from a recent changeover to a new type of pressure vessel built by Structural Composites Industries Inc. of Azusa, Cal. The company employs technology originally developed for rocket motor casings; the cylinders are constructed by winding fibers around an aluminum liner. This technique offers high strength for very low weight-in this case 60 percent less than the pressure vessels earlier used on the 747. Another contribution to improved air safety is an underwater locator device. Called the "Pinger," it uses sonar techniques to locate aircraft crashed in water-or, more specifically, to recover the flight recorder aboard the airplane. Its recovery provides clues as to what caused the accident and suggests measures to prevent similar future occurrences. Until recently, there was no way to recover flight recorders aboard aircraft lost in water crashes. The Pinger, now serving 95 percent of the airline industry, provides an answer. Key element of the Pinger system is a small, battery-powered transmitter, or homing beacon, included as part of the recorder package. For as long as 30 days, the transmitter sends out an acoustic signal from water depths up to 20,000 feet. The other element of the system is a receiver, used by search crews to home in on the transmitter's signal. Originating as a U.S. Navy project, this device was refined and further developed by NASA's Langley Research Center to retrieve submerged nose cones from research rockets. NASA's contractor for the transmitter portion of the system was Dukane Corp., St. Charles, Ill. who subsequently developed the commercial version.

Source record↗

Dynamic training devices in CRM training

Pilot training effectiveness and flying safety of a seasonal tour flight company are described. The change from single pilot to two pilot operated twin otters is examined. The use of the ATC 810 training device, its possibilities and training capacity is outlined. Problem areas which may arise, emergency system and pilot/passenger interaction are analyzed.

Lawver, J.↗

NASA Engineering and Safety Center Technical Bulletin No. 23-07: Best Practices for Fabrication of Microelectronic Devices

Material degradation during the fabrication of microelectronic devices has plagued the space industry for many years owing to the layering of many dissimilar metals to create these devices. Often, commonly used materials and systems are overlooked as potential sources of material degradation. This technical bulletin highlights extensive research to isolate probable causes of this degradation.

Best Practices↗

Design and fabrication of a stereoscopic rear-viewing endoscopic tool (MARVEL)

The use of minimally invasive neurosurgical techniques has experienced a growing interest among patients and surgeons alike due their the numerous advantages over more traditional operations. Current methods employ the use either rigid or articulating endoscopes, both of which are inserted through a small diameter opening in the skull near the intended surgical region. Although these devices aid the surgeon in viewing the operating site, they are severely limited by their inability to provide dimensional awareness to the user. The Multi-Angle Rear-Viewing Endoscopic TooL (MARVEL) has been designed such that the compact form of existing endoscopes is maintained while also providing the user with an enhanced 3-dimensional stereo view. The design of the alpha prototype for MARVEL was completed over the course of three months. In parallel with development, the device's optics were characterized and several software programs were generated. Once assembled, MARVEL will hold many advantages over existing endoscopic tools. It is expected that the device will greatly outperform its traditional counterparts by both increasing safety and decreasing the duration of surgical procedures. After completion, the device will be demonstrated to the project sponsors at the Skull Base Institute where it will undergo full evaluation and a feasibility analysis.

Strongrich, Andrew↗

NASA Workmanship Hot Topics: Water Soluble Flux and ESD Charge Device Model

This slide presentation reviews two topics of interest to NASA Workmanship: (1) Water Soluble Flux (WSF) and Electrostatic Discharge (ESD) safety. In the first topic, WSF, the presentation reviews voiding and the importance of cleanliness in using WSF for welding and soldering operations. The second topic reviews the NASA-HDBK-8739.21 for Human Body Model, and Machine Model safety methods, and challenges associated with the Charged Device Model (CDM)

Plante, Jeannette F.↗

Hardtack II

Armed and ready to fire, Adams remained suspended under a balloon high over the Nevada Test Site throughout the day and night of October 31, 1958. Shortly after midnight, Adams was lowered to the ground and disarmed. With that, Operation Hardtack II ended and a test moratorium, primarily a gentlemen’s agreement between the United States and the Soviet Union, took effect. As the possibility of a moratorium became more and more likely in late 1957, the Atomic Energy Commission and its two weapon laboratories sought Presidential approval for an unprecedented number of tests for the coming year, including a proposal by the UCRL for a series of underground and safety tests in an operation called Millrace. Not wanting to jeopardize ongoing international disarmament talks as well as the moratorium, itself, Eisenhower resisted giving approval for Millrace until late August 1958, barely two months before the anticipated start of the moratorium. Millrace, quickly renamed Hardtack II, was expanded to thirty-seven tests beginning with Otero on September 12 th and concluding with Titania on October 30 th . Eighteen devices, including Otero and Titania, were safety tests. Three of these tests explored “safety characteristics for underground detonations” in tunnels. Two of the three such tests vented. In this respect, Hardtack II was a harbinger of the future in that the problem of venting was never fully resolved. Other safety tests, designed to give no yield, were more successful with San Juan, Oberon, and Ganymede having “no measurable yield.”

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Safety brake for tape reels

All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

Carle, C. E.↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Intelligent Process Visualization through Nuclear Operation Process Modeling, Reasoning, and Object Detection from Field Videos (Final Report)

This report is a deliverable for the “Final Report” task of DOE NEET Project 19-16790, "Context-Aware Safety Information Display for Nuclear Field Workers." This project's overall goal is to test the hypothesis that integrating computer vision and process reasoning methods will enable proactive visualization of the safe operation and maintenance processes of Nuclear Power Plants (NPP) for field workers. Augmented Reality (AR) glasses adopting such proactive safety information visualization techniques can significantly increase personnel safety and reduce the NPP’s operating costs. The current practice of monitoring NPPs requires workers to switch between digital models, data, and physical workspaces in identifying relevant but potentially occluded objects and in assessing the risks of operation and maintenance processes. On the other hand, frequently changed field conditions require field workers to report to supervisors for real-time guidance. Such guidance is essential to ensure that changing conditions will not invalidate or endanger the work order and other ongoing processes that may jeopardize NPP operations. Additionally, incorrect recognition of equipment objects can result in communication errors and safety problems. AR techniques can assist engineers in viewing the physical workspaces with objects labeled with detailed operation procedures and safety reminders during field operations. The project team developed an “Intelligent Context-Aware Safety Information Display” (ICAD) for supporting Nuclear Power Plant (NPP) field workers in achieving safe and efficient execution of a series of operational tasks in uncertain and changing workspaces of an NPP. Before designing the ICAD-AR prototype, the project team synthesized NPP operational knowledge models through literature review studies, surveys, interviews with domain experts, and knowledge modeling. The project team conducted an extensive study of the operational procedures of various NPPs, and digital technologies that can support the safe and efficient execution of those procedures in different NPP operational contexts. This literature review helped the project team conduct surveys and interviews with nuclear engineers and field workers to identify three categories of information. The NPP knowledge modeling efforts reveal that the three categories of information identified have different levels of importance in a typical procedure of carrying out a series of tasks to achieve a specific NPP operation goal (e.g., shutdown, mode changes). These three categories of information include 1) Workspace dynamics – the changing spatial arrangements of workspaces, tools, protection equipment, and supporting materials, 2) Workflow prognostics – the dynamic dependencies between different parts of an NPP that functionally support and influence each other in terms of safety and efficiency, and 3) Hazards – objects and spaces that contain hazardous materials or physical conditions that can pose risks to workers or mechanical systems. The project team has profiled the importance levels of these categories of information into a knowledge model. This knowledge model specifies what types of information are more critical for a given task in a given workspace so that computers can automatically identify critical objects and sensors in a scene for delivering context-ware safety information to field workers through AR devices. Significant research development of this project results in technical research outcomes and a prototyping system that illustrates the technical feasibility of establishing an ICAD-AR system supporting the proactive safety information display for nuclear field workers. This final report summarizes the project team’s technological achievements in the past three years. Overall, the project team completed the development and integration of five techniques into a prototype ICAD Augmented Reality (ICAD-AR) system and demonstrated the developed system’s real-time execution in a mechanical room. The project team completed the analysis of using this prototype in other types of workspaces based on 3D image data and digital design models collected from two additional workspaces (a water treatment plant and a flow loop training facility). The integrated techniques include 1) Natural Language Processing (NLP) algorithms supporting the generation and updates of nuclear fieldwork process models based on text analysis of work packages and operation manuals; 2) sensor log analysis for predicting control actions in given sensor reading contexts; 3) computer vision algorithms for automatic localization and navigation of workers; 4) object detection algorithms for identifying task-related objects and correlated sensors for safety checking; 5) AR technique as a platform for supporting the integration. The testing results of these five techniques have shown that 1) the sensor log analysis model can predict the next control action with an accuracy of 0.883; 2) the trained natural language processing model can extract more than 80% of the critical information from paper-based procedures (PBPs); 3) the navigation algorithm with the integration of Visual Inertial Odometry (VIO) and Non-Recursive Bayesian Filter methods make operator’s trajectory estimation resilient to drift error; 4) the computer vision algorithm can detect task-specific and safety-critical objects with an average accuracy of 95.3%. The project team used work procedures collected from a flow loop training facility and two datasets collected from two mechanical rooms simulating the workspaces of NPPs to demonstrate the technical capabilities of the developed ICAD-AR prototype. The demonstration validated the technical feasibility of establishing the ICAD-AR system for nuclear field workers and identified the challenges in 1) automatic text analysis of work packages; 2) use of limited samples of sensor logs for predicting the proper timings of control actions; 3) reliably tracking workers and their task progress in mechanical rooms with many similar objects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate↗

Software development for safety-critical medical applications

There are many computer-based medical applications in which safety and not reliability is the overriding concern. Reduced, altered, or no functionality of such systems is acceptable as long as no harm is done. A precise, formal definition of what software safety means is essential, however, before any attempt can be made to achieve it. Without this definition, it is not possible to determine whether a specific software entity is safe. A set of definitions pertaining to software safety will be presented and a case study involving an experimental medical device will be described. Some new techniques aimed at improving software safety will also be discussed.

Knight, John C.↗

Development of A Non-Explosive Release Device for Aerospace Applications

A simple, non-explosive, high load-capacity release mechanism using shape memory alloy is currently being developed for space flight. This device, the Frangibolt, could replace most pyrotechnic devices in applications where the need for safety, reliability, non-destructive testing, and minimal mechanical shock is more crucial than the need for rapid actuation. Prototype hardware has been designed, tested, and proven in laboratory conditions. Operation and demonstration of these devices evidenced reliable and repeatable performance, clearly indicating that extensive testing for flight qualification is warranted. Here, the Frangibolt design is discussed, recent test results of laboratory units are described, and the work that must be performed in the upcoming months to qualify the device for aerospace applications is addressed.

John D Busch↗

Software Safety Assurance of Programmable Logic

Programmable Logic (PLC, FPGA, ASIC) devices are hybrids - hardware devices that are designed and programmed like software. As such, they fall in an assurance gray area. Programmable Logic is usually tested and verified as hardware, and the software aspects are ignored, potentially leading to safety or mission success concerns. The objective of this proposal is to first determine where and how Programmable Logic (PL) is used within NASA and document the current methods of assurance. Once that is known, raise awareness of the PL software aspects within the NASA engineering community and provide guidance for the use and assurance of PL form a software perspective.

Berens, Kalynnda↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement, testing, and safety technology: A compilation

Methods and techniques in the related areas of measurement, testing, and safety are presented. Measuring techniques and devices and testing methods and devices are described. Articles on equipment modifications or procedures are included. Patent information is presented.

Source record↗