Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCREEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Screening and Management of Asymptomatic Renal Stones in Astronauts

Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The true risk for renal stone formation in astronauts due to the space flight environment is unknown. Proper management of this condition is crucial to mitigate health and mission risks. The NASA Flight Medicine Clinic electronic medical record and the Lifetime Surveillance of Astronaut Health databases were reviewed. An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was also done. This work was used to develop a screening and management protocol for renal stones in astronauts that is relevant to the spaceflight operational environment. In the proposed guidelines all astronauts receive a yearly screening and post-flight renal ultrasound using a novel ultrasound protocol. The ultrasound protocol uses a combination of factors, including: size, position, shadow, twinkle and dispersion properties to confirm the presence of a renal calcification. For mission-assigned astronauts, any positive ultrasound study is followed by a low-dose renal computed tomography scan and urologic consult. Other specific guidelines were also created. A small asymptomatic renal stone within the renal collecting system may become symptomatic at any time, and therefore affect launch and flight schedules, or cause incapacitation during a mission. Astronauts in need of definitive care can be evacuated from the International Space Station, but for deep space missions evacuation is impossible. The new screening and management algorithm has been implemented and the initial round of screening ultrasounds is under way. Data from these exams will better define the incidence of renal stones in U.S. astronauts, and will be used to inform risk mitigation for both short and long duration spaceflights.

Reyes, David↗

Screening and Management of Asymptomatic Renal Stones in Astronauts

Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The true risk for renal stone formation in astronauts due to the space flight environment is unknown. Proper management of this condition is crucial to mitigate health and mission risks. The NASA Flight Medicine Clinic electronic medical record and the Lifetime Surveillance of Astronaut Health databases were reviewed. An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was also done. This work was used to develop a screening and management protocol for renal stones in astronauts that is relevant to the spaceflight operational environment. In the proposed guidelines all astronauts receive a yearly screening and post-flight renal ultrasound using a novel ultrasound protocol. The ultrasound protocol uses a combination of factors, including: size, position, shadow, twinkle and dispersion properties to confirm the presence of a renal calcification. For mission-assigned astronauts, any positive ultrasound study is followed by a low-dose renal computed tomography scan and urologic consult. Other specific guidelines were also created. A small asymptomatic renal stone within the renal collecting system may become symptomatic at any time, and therefore affect launch and flight schedules, or cause incapacitation during a mission. Astronauts in need of definitive care can be evacuated from the International Space Station, but for deep space missions evacuation is impossible. The new screening and management algorithm has been implemented and the initial round of screening ultrasounds is under way. Data from these exams will better define the incidence of renal stones in U.S. astronauts, and will be used to inform risk mitigation for both short and long duration spaceflights.

Reyes, David↗

Suomi NPP VIIRS Solar Diffuser Screen Transmittance Model and Its Applications

The visible infrared imaging radiometer suite on the Suomi National Polar-orbiting Partnership satellite calibrates its reflective solar bands through observations of a sunlit solar diffuser (SD) panel. Sunlight passes through a perforated plate, referred to as the SD screen, before reaching the SD. It is critical to know whether the SD screen transmittance measured prelaunch is accurate. Several factors such as misalignments of the SD panel and the measurement apparatus could lead to errors in the measured transmittance and thus adversely impact on-orbit calibration quality through the SD. We develop a mathematical model to describe the transmittance as a function of the angles that incident light makes with the SD screen, and apply the model to fit the prelaunch measured transmittance. The results reveal that the model does not reproduce the measured transmittance unless the size of the apertures in the SD screen is quite different from the design value. We attribute the difference to the orientation alignment errors for the SD panel and the measurement apparatus. We model the alignment errors and apply our transmittance model to fit the prelaunch transmittance to retrieve the "true" transmittance. To use this model correctly, we also examine the finite source size effect on the transmittance. Furthermore, we compare the product of the retrieved "true" transmittance and the prelaunch SD bidirectional reflectance distribution function (BRDF) value to the value derived from on-orbit data to determine whether the prelaunch SD BRDF value is relatively accurate. The model is significant in that it can evaluate whether the SD screen transmittance measured prelaunch is accurate and help retrieve the true transmittance from the transmittance with measurement errors, consequently resulting in a more accurate sensor data product by the same amount.

sensors↗

OSIRIS-REx Screening Experience & Lessons Learned

On September 24, 2023, the NASA OSIRIS-REx spacecraft returned a sample of asteroid Bennu, approaching on a hyperbolic impact trajectory relative to Earth. At approximately 108,000 km altitude and four hours prior to hitting the top of the atmosphere, the Sample Return Capsule (SRC) separated from the spacecraft bus, targeting the Utah Test and Training Range. Twenty minutes later, the bus performed a large divert maneuver to fly by at a perigee altitude of ~780 km. Given the immense scientific value of the sample, substantial efforts were undertaken by NASA CARA and the OSIRIS-REx mission to ensure safe passage of the objects from GEO through LEO. This presentation provides an overview of collision avoidance maneuver (CAM) options, results of screenings, coordination with DoD for contingency observations, and lessons learned for screening future Earth flyby and entry trajectories. Two particular challenges included screening two objects using a much larger than normal 250 km spherical monitor volume and decision planning for a single CAM while the SRC was still attached that would alter both trajectories. The larger, non-standard screening volume resulted in custom procedures that CARA personnel had to run manually for each screening, and the initial long propagation times while the objects were more than a week out required significant computing resources. With a single CAM opportunity at 13 hours out, the decision to execute a maneuver had to consider the risk to both objects, where one could imagine a situation where the maneuver would clear a high-risk conjunction for one object and introduce one for the other – begging the question of relative risk posture between the SRC and bus. These among other unique aspects of Earth flyby and entry missions led to novel planning and implementation procedures to support future missions of this type.

Dolan E. Highsmith↗

Quantifying Human Behavior and Decision Errors in Security Screening Operations

The potential for human errors in conducting security related screening operations can lead to inadvertent and adverse decision outcomes. This paper overviews an initial mathematical framework designed to model and quantify the various human factors and decision outcomes that may occur in conducting security screening operations, such as U.S. port of entry radiological and nuclear (rad/nuc) security screening. This framework is based on the Human Error Assessment and Reduction (HEART) technique. As applied here, the framework incorporates a set of rules for human engagement, including a prescribed concept of operations (CONOPS) and deviations that may occur from this established CONOPS due to inadvertent personnel decision errors. We also review some of the various factors that may adversely influence such decisions by security screening personnel. Some of these factors include current workload, environmental conditions, training, and various other intangible factors. Using the HEART methodology, we translate each of these factors into error producing conditions, their effects on error, an assessed proportion of effects, and finally the overall probability of human error at each stage of the screening process. We then include a small scale example to demonstrate the methodology and results based on an assumed set of input conditions at a notional port of entry.

Brigantic, Robert T.↗

Optimal Decision Making in High-Throughput Virtual Screening Pipelines

ABSTRACT Effective selection of the potential candidates that meet certain conditions in a tremendously large search space has been one of the major concerns in many real-world applications. In addition to the nearly infinitely large search space, rigorous evaluation of a sample based on the reliable experimental or computational platform is often prohibitively expensive, making the screening problem more challenging. In such a case, constructing a high-throughput screening (HTS) pipeline that pre-sifts the samples expected to be potential candidates through the efficient earlier stages, results in a significant amount of savings in resources. However, to the best of our knowledge, despite many successful applications, no one has studied optimal pipeline design or optimal pipeline operations. In this study, we propose two optimization frameworks, applying to most (if not all) screening campaigns involving experimental or/and computational evaluations, for optimally determining the screening thresholds of an HTS pipeline. We validate the proposed frameworks on both analytic and practical scenarios. In particular, we consider the optimal computational campaign for the long non-coding RNA (lncRNA) classification as a practical example. To accomplish this, we built the high-throughput virtual screening (HTVS) pipeline for classifying the lncRNA. The simulation results demonstrate that the proposed frameworks significantly reduce the effective selection cost per potential candidate and make the HTS pipelines less sensitive to their structural variations. In addition to the validation, we provide insights on constructing a better HTS pipeline based on the simulation results.

97 MATHEMATICS AND COMPUTING↗

Screening and Discovery of Metal Compound Active Sites for Strong and Selective Adsorption of N 2 in Air

Photocatalytic nitrogen fixation has the potential to provide a greener route for producing nitrogen-based fertilizers under ambient conditions. Computational screening is a promising route to discover new materials for the nitrogen fixation process, but requires identifying “descriptors” that can be efficiently computed. In this work, we argue that selectivity toward the adsorption of molecular nitrogen and oxygen can act as a key descriptor. A catalyst that can selectively adsorb nitrogen and resist poisoning of oxygen and other molecules present in air has the potential to facilitate the nitrogen fixation process under ambient conditions. Here we provide a framework for active site screening based on multifidelity density functional theory (DFT) calculations for a range of metal oxides, oxyborides, and oxyphosphides. The screening methodology consists of initial low-fidelity fixed geometry calculations and a second screening in which more expensive geometry optimizations were performed. The approach identifies promising active sites on several TiO 2 polymorph surfaces and a VBO 4 surface, and the full nitrogen reduction pathway is studied with the BEEF-vdW and HSE06 functionals on two active sites. The findings suggest that metastable TiO 2 polymorphs may play a role in photocatalytic nitrogen fixation, and that VBO 4 may be an interesting material for further studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying limitations in screening high-throughput photocatalytic bimetallic nanoparticles with machine-learned hydrogen adsorptions

The Sabatier principle is of fundamental importance to computational catalyst discovery, saving researchers time and expense by predicting catalytic activity in silico at scale. However, as polycrystalline and nanoscale catalysts increasingly dominate industry, computational screening tools must be adapted to these uses. In this work, we demonstrate the effectiveness of computational adsorption energy screening in nanocatalysis by comparing a multisite adsorption energy prediction workflow against a large experimental dataset of hydrogen evolution activities over bimetallic nanoparticles. Comparing 16 million hydrogen adsorption energy predictions with the hydrogen evolution activity of 5300 experiments across 84 monometallic and bimetallic systems, we discover that favorable adsorption energies are a necessary condition for experimental activity, but other factors often determine trends in practice. Finally, about half of the bimetallic search space can be excluded from experimental screens using hydrogen adsorption predictions, but this method may become significantly more powerful when combined with other screening tools.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and Evaluation of Fluorophore-Doped Polymer Substrates to Screen for Plastic-Degrading Enzymes

Fast and sensitive analytical methods are the key to efficient screening of plastic-degrading enzymes. Here, we present a streamlined and affordable approach to assess the enzymatic deconstruction of insoluble synthetic polymers by blending them with a fluorescent dye, rhodamine 6G, and we evaluate this screening method using poly(ethylene terephthalate) (PET) as a model material. Our results indicate that enzymatic depolymerization of the rhodamine-doped PET can be observed in a high-throughput fashion by following release of the fluorophore. The fluorescence data obtained during the hydrolysis of rhodamine-doped PET by 14 PET hydrolases, produced with a robotic platform, correlated with the quantitative chromatographic analysis of PET degradation products. Remarkably, the use of the rhodamine-loaded PET substrate resulted in negligibly low background signals even when detecting PETase activity in crude cell lysates, suggesting suitability for screening of a wide variety of samples. Encouraged by these results, we next produced a selection of polyethylene- and nylon-based materials loaded with rhodamine 6G. While rapid leaching of fluorophore observed with nylon substrates limits the utility of the method for detecting nylonase activity, the rhodamine-loaded polyethylene showed promising performance in passive diffusion tests, indicating that this latter substrate may be used to screen for polyolefin-degrading enzymes.

09 BIOMASS FUELS↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An automated workflow to screen alkene reductases using high-throughput thin layer chromatography

Background: Synthetic biology efforts often require high-throughput screening tools for enzyme engineering campaigns. While innovations in chromatographic and mass spectrometry-based techniques provide relevant structural information associated with enzyme activity, these approaches can require cost-intensive instrumentation and technical expertise not broadly available. Moreover, complex workflows and analysis time can significantly impact throughput. To this end, we develop an automated, 96-well screening platform based on thin layer chromatography (TLC) and use it to monitor in vitro activity of a geranylgeranyl reductase isolated from Sulfolobus acidocaldarius (SaGGR). Results: Unreduced SaGGR products are oxidized to their corresponding epoxide and applied to thin layer silica plates by acoustic printing. These derivatives are chromatographically separated based on the extent of epoxidation and are covalently ligated to a chromophore, allowing detection of enzyme variants with unique product distributions or enhanced reductase activity. Herein, we employ this workflow to examine farnesol reduction using a codon-saturation mutagenesis library at the Leu377 site of SaGGR. We show this TLC-based screen can distinguish between fourfold differences in enzyme activity for select mutants and validated those results by GC–MS. Conclusions: With appropriate quantitation methods, this workflow can be used to screen polyprenyl reductase activity and can be readily adapted to analyze broader catalyst libraries whose products are amenable to TLC analysis.

09 BIOMASS FUELS↗

CO2-SCREEN

CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN) is a tool which was developed by the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) to screen saline formations for prospective CO2 storage resources. CO2-SCREEN applies U.S. DOE methods and equations for estimating prospective CO2 storage resources for saline formations. This provides a dependable method for calculating prospective CO2 storage resources which allows for consistent comparison of results between different research efforts. CO2-SCREEN latest version (v5.0) is a python application that utilizes a Java front end user interface. The 3.0 version consists of an Excel spreadsheet containing geologic inputs and outputs, linked to a GoldSim Player model that calculates prospective CO2 storage resources via Monte Carlo simulation. https://www.youtube.com/watch?v=lhakk-HYfOI

CO2 Storage Resource,Prospective Storage,Screening↗

Improving Solar and Solar+Storage Screening Techniques to Reduce Utility Interconnection Time and Costs (Final Technical Report)

Residential PV installations have increased rapidly over the last decade, and the increased application volume has caused permitting delays and lower overall adoption rates. In this project, we developed and evaluated whether data-driven secondary modeling and screening techniques can help utilities assess customer applications more accurately than traditional screening shortcuts. Secondary topologies are predicted using decision trees and commonly available information, such as service transformer, customer, and street locations. Conductors were predicted using a logistic regression method based on real world object (RWO) types, service transformer ratings, conductor length, and distance to transformer. After developing the combined primary and secondary distribution network model, hosting capacity results were used to train a random forest model to predict the pass/fail likelihood of a customer application. Powerflow based models with predicted secondaries and data-driven methods both increased the screening success rate, relative to common utility heuristics, by as much as 55 percentage points. Data-driven screening techniques were described by one utility as a "right-sized" approach for residential customers given the low-risk of small errors and the high-cost of accurate modeling.

14 SOLAR ENERGY↗

Beyond sequence similarity: toward function-based screening of nucleic acid synthesis

Synthetic nucleic acids are a key input to modern biotechnology, yet they represent dual-use materials that require robust screening to mitigate biosecurity risks. The prevailing screening paradigm, which identifies sequences of concern (SoCs) through sequence similarity to controlled pathogens and toxins, may not fully capture risks posed by AI tools that can decouple biomolecular function from reliance on known sequences. Rapidly advancing biodesign capabilities enable the generation of genes and proteins that might evade sequence-based detection. We highlight the critical need for function-based screening approaches that can detect sequences capable of hazardous biological functions, regardless of similarity to known SoCs. We examine the feasibility of function-based screening with an initial focus on proteins, arguing that, while protein sequence space is vast, biologically functional proteins are significantly constrained by biophysical and biochemical requirements that can be learned and modeled. We propose a concrete implementation framework organized along a continuum of complexity, starting with toxins as the most tractable targets before expanding to more complex pathogenic functions. We then discuss open challenges and describe a research and development strategy to address them.

59 BASIC BIOLOGICAL SCIENCES↗

Drugsniffer: An Open Source Workflow for Virtually Screening Billions of Molecules for Binding Affinity to Protein Targets

The SARS-CoV2 pandemic has highlighted the importance of efficient and effective methods for identification of therapeutic drugs, and in particular has laid bare the need for methods that allow exploration of the full diversity of synthesizable small molecules. While classical high-throughput screening methods may consider up to millions of molecules, virtual screening methods hold the promise of enabling appraisal of billions of candidate molecules, thus expanding the search space while concurrently reducing costs and speeding discovery. Here, we describe a new screening pipeline, called drugsniffer, that is capable of rapidly exploring drug candidates from a library of billions of molecules, and is designed to support distributed computation on cluster and cloud resources. As an example of performance, our pipeline required ~40,000 total compute hours to screen for potential drugs targeting three SARS-CoV2 proteins among a library of ~3.7 billion candidate molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot↗

Adaptive Data Screening for Multi-Angle Polarimetric Aerosol and Ocean Color Remote Sensing Accelerated by Automatic Differentiation

Remote sensing measurements from multi-angle polarimeters (MAPs) contain rich aerosol microphysical property information, and these sensors have been used to perform retrievals in optically complex atmosphere and ocean systems. Previous studies have concluded that, generally, five moderately separated viewing angles in each spectral band provide sufficient accuracy for aerosol property retrievals, with performance gradually saturating as angles are added above that threshold. The Hyper-Angular Rainbow Polarimeter (HARP) instruments provide high angular sampling with a total of 90-120 unique angles across four bands, a capability developed mainly for liquid cloud retrievals. In practice, not all view angles are optimal for aerosol retrievals due to impacts of clouds, sun glint, and other impediments. The many viewing angles of HARP can provide resilience to these effects, if the impacted views are screened from the dataset, as the remaining views may be sufficient for successful analysis. In this study, we discuss how the number of available viewing angles impacts aerosol and ocean color retrieval uncertainties, as applied to two versions of the HARP instrument. AirHARP is an airborne prototype that was deployed in the ACEPOL field campaign, while HARP2 is an instrument in development for the upcoming NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. Based on synthetic data, we find that a total of 20-30 angles across all bands (i.e. five to eight viewing angles per band) are sufficient to achieve good retrieval performance. Following from this result, we develop an adaptive multi-angle polarimetric data screening (MAPDS) approach to evaluate data quality by comparing measurements with their best-fitted forward model. The FastMAPOL retrieval algorithm is used to retrieve scene geophysical values, by matching an efficient, deep learning-based, radiative transfer emulator to observations. The data screening method effectively identifies and removes viewing angles affected by thin cirrus clouds and other anomalies, improving retrieval performance. This was tested with AirHARP data, and we found agreement with the High Spectral Resolution Lidar-2 (HSRL-2) aerosol data. The data screening approach can be applied to modern satellite remote sensing missions, such as PACE, where a large amount of multi-angle, hyperspectral, polarimetric measurements will be collected.

multi-angle polarimeter↗