Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCREENING TECHNIQUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Laser beam scintillation beyond the turbulent atmosphere A numerical computation

The extended Huygens-Fresnel formulation for propagation through turbulence is used to examine scintillation of a finite laser beam. The method is demonstrated analytically for propagation beyond a weak Gaussian phase screen. A numerical integration technique is used to extend the results to a more realistic turbulence model. Results are compared with existing Gaussian beam propagation theory.

Bufton, J. L.↗

Ultrasonic velocity for estimating density of structural ceramics

The feasibility of using ultrasonic velocity as a measure of bulk density of sintered alpha silicon carbide was investigated. The material studied was either in the as-sintered condition or hot isostatically pressed in the temperature range from 1850 to 2050 C. Densities varied from approximately 2.8 to 3.2 g cu cm. Results show that the bulk, nominal density of structural grade silicon carbide articles can be estimated from ultrasonic velocity measurements to within 1 percent using 20 MHz longitudinal waves and a commercially available ultrasonic time intervalometer. The ultrasonic velocity measurement technique shows promise for screening out material with unacceptably low density levels.

Klima, S. J.↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

A Prototype Lisp-Based Soft Real-Time Object-Oriented Graphical User Interface for Control System Development

A prototype Lisp-based soft real-time object-oriented Graphical User Interface for control system development is presented. The Graphical User Interface executes alongside a test system in laboratory conditions to permit observation of the closed loop operation through animation, graphics, and text. Since it must perform interactive graphics while updating the screen in real time, techniques are discussed which allow quick, efficient data processing and animation. Examples from an implementation are included to demonstrate some typical functionalities which allow the user to follow the control system's operation.

Litt, Jonathan↗

Reduction of Convection in Closed Tube Vapor Transport Experiments

The primary objective of this effort was to develop a method for suppressing convective flows during the growth of mercurous chloride crystals by vapor transport in closed tubes to levels approaching those obtained in the microgravity environment. Mercurous chloride was chosen because it is a technologically interesting acoustical optical material whose optical properties are believed to be affected by convective flows. Since the Grashof number scales as the cube of the smallest dimension in the flow system, reduction of the size scale can be extremely effective in reducing unwanted convective flows. However, since materials of practical interest must be grown at least on the cm scale, reduction of the overall growth system is not feasible. But if the region just above the growing crystal could be restricted to a few mm, considerable reduction in flow velocity would result. By suspending an effusive barrier in the growth ampoule just above the growth interface, it should be possible to reduce the convective velocity in this vicinity to levels approaching flows in microgravity. If successful, this growth technique will offer a screening test for proposed space experiments that involve vapor transport to see if reduction of convection will result in improved material and will set a new standard against which the improvements obtained in microgravity may be judged. In addition, it may provide an improved method for preparing materials on Earth whose growth is affected adversely by convection. If the properties of this material can be improved there is a potential commercial interest from Brimrose Inc., who has agreed to fabricate and test devices from the crystals we have grown. This report describes the development of the growth facility, the purification processes developed for preparing the starting material, and the results from growth experiments with and without the effusive baffle. Mercurous chloride turned out to be a more difficult material to deal with than originally anticipated. At growth temperatures, it is extremely sensitive to practically any impurity which causes it to form oxychlorides and/or to decompose into elemental mercury and bichloride of mercury. We were unable to find a suitable method for protecting the magnetic material used to suspend the effusion barrier from the attack of mercurous chloride vapor. Although we were successful in growing single crystals of mercurous chloride without the effusion baffle, they exhibited severe microcracking which we attribute to wall-induced thermal stresses. This leads us to believe that uncontrolled convection may not be the most important problem in the development of this material and a new growth process was attempted that eliminates the wall-induced stress. Unfortunately, the grant ran out before this new method could be adequately tested.

Naumann, R. J.↗

The Promise of Macromolecular Crystallization in Micro-fluidic Chips

Micro-fluidics, or lab on a chip technology, is proving to be a powerful, rapid, and efficient approach to a wide variety of bio-analytical and microscale bio-preparative needs. The low materials consumption, combined with the potential for packing a large number of experiments in a few cubic centimeters, makes it an attractive technique for both initial screening and subsequent optimization of macromolecular crystallization conditions. Screening operations, which require equilibrating macromolecule solution with a standard set of premixed solutions, are relatively straightforward and have been successfully demonstrated in a micro-fluidics platform. More complex optimization methods, where crystallization solutions are independently formulated from a range of stock solutions, are considerably more complex and have yet to be demonstrated. To be competitive with either approach, a micro-fluidics system must offer ease of operation, be able to maintain a sealed environment over several weeks to months, and give ready access for the observation of crystals as they are grown.

vanderWoerd, Mark↗

The promise of macromolecular crystallization in microfluidic chips

Microfluidics, or lab-on-a-chip technology, is proving to be a powerful, rapid, and efficient approach to a wide variety of bioanalytical and microscale biopreparative needs. The low materials consumption, combined with the potential for packing a large number of experiments in a few cubic centimeters, makes it an attractive technique for both initial screening and subsequent optimization of macromolecular crystallization conditions. Screening operations, which require a macromolecule solution with a standard set of premixed solutions, are relatively straightforward and have been successfully demonstrated in a microfluidics platform. Optimization methods, in which crystallization solutions are independently formulated from a range of stock solutions, are considerably more complex and have yet to be demonstrated. To be competitive with either approach, a microfluidics system must offer ease of operation, be able to maintain a sealed environment over several weeks to months, and give ready access for the observation and harvesting of crystals as they are grown.

Review↗

On-chip polarimetry for high-throughput screening of nanoliter and smaller sample volumes

A polarimetry technique for measuring optical activity that is particularly suited for high throughput screening employs a chip or substrate (22) having one or more microfluidic channels (26) formed therein. A polarized laser beam (14) is directed onto optically active samples that are disposed in the channels. The incident laser beam interacts with the optically active molecules in the sample, which slightly alter the polarization of the laser beam as it passes multiple times through the sample. Interference fringe patterns (28) are generated by the interaction of the laser beam with the sample and the channel walls. A photodetector (34) is positioned to receive the interference fringe patterns and generate an output signal that is input to a computer or other analyzer (38) for analyzing the signal and determining the rotation of plane polarized light by optically active material in the channel from polarization rotation calculations.

Bornhop, Darryl J.↗

Design development and manufacture of a breadboard radio frequency mass gauging system. Volume 1: Phase B final report

The applicability of the RF Mode Counting technique for gauging liquid oxygen and liquid hydrogen under all attitude conditions was demonstrated using a vacuum jacketed test tank mounted on a remotely controlled gimbaling mechanism. In addition, the technique was successfully tested using liquid oxygen in a large NASA test tank as the tank was filled and emptied. To further substantiate the capabilities of the RF Mode Counting technique as applied to applications involving zero gravity conditions, a test system using benzene as a test fluid was flight tested in a KC-135 test aircraft. This testing involved a number of zero "g" maneuvers with various quantities of the test fluid. A series of tests were also performed to evaluate the relative effects of the presence of capillary liquid retention screens on the RF Gauging technique. These tests involved considerations of system Q reductions, RF leakage through retention screens, and surface wetting effects.

Source record↗

Measurement of Screen-Size Effects on Intensity, Scale, and Spectrum of Turbulence in a Free Subsonic Jet

The results are reported of hot-wire anemometer measurements of the fluctuating longitudinal component of the turbulent velocities in the mean flow downstream of screens in an air jet. These measurements have been analyzed by well-established techniques to give the influence of tile screen mesh size on the turbulent intensity, scale, and the power-spectral-density. The results show a linear dependence of the intensity upon the screen mesh size for locations within the central core of the air jet. The spectral-density curves show that the screens redistribute the turbulent energy from the low frequencies (<1000 cps) to the high frequencies (>1000 cps). The effects of the screens are overwhelmed in the mixing region of the jet flow by the turbulence levels existing there. The large pressure drops occurring across the screens reduce the velocity of the jet as compared to the jet without screens by approximately one-third for the velocity and range of mesh sizes investigated and reported in this report. The turbulence scale is a linear function of distance from the nozzle exit and is somewhat greater than comparable jets without screens.

Howard, Charles D.↗

UV blocking filters for polymeric films

The concept of incorporating UV screening agents in silicone resins as a means of protecting underlying solar cell covers and adhesives from UV degradation is presented. A silicone hard-coat resin incorporating a UV screening agent was selected as a suitable coating material for PFA Teflon solar cell covers. Consideration is given to fabrication procedures and techniques for introduction of the UV screening agents into silicone resins and application of these UV-inhibited coatings to the Teflons. Some preliminary environmental tests, such as thermal shock and temperature humidity, were conducted.

Rayl, G. J.↗

Sensitivity of F-106B Leading-Edge-Vortex Images to Flight and Vapor-Screen Parameters

A flight test was undertaken at NASA Langley Research Center with vapor-screen and image-enhancement techniques to obtain qualitative and quantitative information about near-field vortex flows above the wings of fighter aircraft. In particular, the effects of Reynolds and Mach numbers on the vortex system over an angle-of-attack range were sought. The relevance of these flows stems from their present and future use at many points in the flight envelope, especially during transonic maneuvers. The aircraft used in this flight program was the F-106B because it was available and had sufficient wing sweep (60 deg) to generate a significant leading-edge vortex system. The sensitivity of the visual results to vapor screen hardware and to onset flow changes is discussed.

Lamar, John E.↗

Sensor failure detection system

Advanced concepts for detecting, isolating, and accommodating sensor failures were studied to determine their applicability to the gas turbine control problem. Five concepts were formulated based upon such techniques as Kalman filters and a screening process led to the selection of one advanced concept for further evaluation. The selected advanced concept uses a Kalman filter to generate residuals, a weighted sum square residuals technique to detect soft failures, likelihood ratio testing of a bank of Kalman filters for isolation, and reconfiguring of the normal mode Kalman filter by eliminating the failed input to accommodate the failure. The advanced concept was compared to a baseline parameter synthesis technique. The advanced concept was shown to be a viable concept for detecting, isolating, and accommodating sensor failures for the gas turbine applications.

Beattie, E. C.↗

Long life assurance study for manned spacecraft long life hardware. Volume 3: Long life assurance studies of components

The guidelines for selecting hardware to be used in manned spacecraft to obtain a five year operational lifetime without maintenance were developed. An analysis was conducted on the design, application, failure mechanisms, manufacturing processes and controls, screen and burn-in techniques, and quality control of hardware items. The equipment considered for evaluation include: (1) electric motors and bearings; (2) accelerometers; (3) gyroscopes and bearings; (4) compressors and pumps, (5) magnetic tape recorders; (6) plumbing components and tubing; (7) check valves; (8) pressure regulators and solenoid valves; (9) thermal control valves; (10) pressure vessels and positive expulsion devices; (11) nickel cadmium batteries; and (12) transducers.

Source record↗

Considerations of and improvements to large-scale vegetation monitoring

The NOAA-7 polar orbiting sun-synchronous operational satellite carries the 5-channel advanced very high-resolution radiometer which acquires data globally at a spatial resolution of 4 km on a daily basis. These data provide a means for frequently monitoring global vegetation at continental scales. Techniques for compositing and cloud screening a green leaf density vegetation index product for Africa are presented for 9 sequential days beginning August 16, 1982 and are compared with a semi-operational vegetation index product produced by NOAA.

Gatlin, J. A.↗

Monitoring global vegetation using NOAA-7 AVHRR data

The NOAA-7 polar orbiting, sun-synchronous, operational satellite carries the 5 channel Advanced Very High Resolution Radiometer (AVHRR). Data are acquired globally at a resolution of 4 km on a daily basis. This data provides the means of frequently monitoring global vegetation on continental scales. Techniques for compositing and cloud screening a vegetation index for Africa are presented. The sample data set covers 9 days beginning August 16, 1983 and is compared with a semi-operational vegetation index product produced by NOAA.

Gatlin, J. A.↗

An improved large-field focusing schlieren system

The analysis and performance of a high-brightness large-field focusing schlieren system is described. The system can be used to examine complex two- and three-dimensional flows. Techniques are described to obtain focusing schlieren through distorting optical elements, to use multiple colors in a time multiplexing technique, and to use diffuse screen holography for three-dimensional photographs.

Weinstein, Leonard M.↗