Fluid flow in solidifying monotectic alloys

Use of a two-wavelength holographic technique results in a simultaneous determination of temperature and composition profiles during directional solidification in a system with a miscibility gap. The relationships among fluid flow, phase separation, and mass transport during the solidification of the monotectic alloy are discussed. The primary sources of fluid motion in this system are buoyancy and thermocapillary forces. These forces act together when phase separation results in the formation of droplets (this occurs at the solid-liquid interface and in the bulk melt). In the absence of phase separation, buoyancy results from density gradients related to temperature and compositional gradients in the single-phase bulk melt. The effects of buoyancy are especially evident in association with water- or ethanol-rich volumes created at the solid-liquid growth interface.

Ecker, A.↗

Low energy gamma ray attenuation in multiphase water

A gauging system is proposed to enable monitoring of slush density, solid-liquid interface, and slush level as well as its flow rate. It is based on the principle that the electromagnetic radiation mass attenuation coefficient of a multiphase chemical compound is constant for all relative phase concentrations. Results showing the essential constancy of mass attenuation coefficients for single-phase water vapor, liquid water, ice, and multiphase mixtures of water/ice are described.

Singh, Jag J.↗

Structure of a swirl-stabilized combusting spray

Measurements of the structure of a swirl-stabilized, reacting spray are presented. The configuration consisted of a research air-assist atomizer located in the center surrounded by a co-flowing airstream. Both the air-assist and co-flowing streams had swirl imparted to them in the same direction with 45-deg angle swirlers. The fuel and air entered the combustor at ambient temperature and the combustor was operated in an unconfined environment. The gas phase was seeded with aluminum-oxide particles in order to obtain velocity measurements. Mean velocity measurements for the gas phase are reported for both an isothermal, single-phase case without drops and a reacting spray case at axial distances from 2.5 to 50 mm downstream of the nozzle. Heptane fuel was used for all the experiments. Drop size and mean velocity and drop number flux are also reported for five axial distances downstream. The measurements were performed using a two-component phase/Doppler particle analyzer. Profiles across the entire flowfield where velocities were significant are presented. Mean gas-phase temperatures were also measured intrusively using a single pt/pt-13%rh thermocouple and are also reported at axial distances from 2.5 to 50 "im downstream of the nozzle.

Bulzan, Daniel L.↗

Analysis and Modeling of a Two-Phase Jet Pump of a Flow Boiling Test Facility for Aerospace Applications

Jet pumps are devices capable of pumping fluids to a higher pressure employing a nozzle/diffuser/mixing chamber combination. A primary fluid is usually allowed to pass through a converging-diverging nozzle where it can accelerate to supersonic speeds at the nozzle exit. The relatively high kinetic energy that the primary fluid possesses at the nozzle exit is accompanied by a low pressure region in order to satisfy Bernoulli's equation. The low pressure region downstream of the nozzle exit permits a secondary fluid to be entrained into and mixed with the primary fluid in a mixing chamber located downstream of the nozzle. Several combinations may exist in terms of the nature of the primary and secondary fluids in so far as whether they are single or two-phase fluids. Depending on this, the jet pump may be classified as gas/gas, gas/liquid, liquid/liquid, two-phase/liquid, or similar combinations. The mixing chamber serves to create a homogeneous single-phase or two-phase mixture which enters a diffuser where the high kinetic energy of the fluid is converted into pressure energy. If the fluid mixture entering the diffuser is in the supersonic flow regime, a normal shock wave usually develops inside the diffuser. If the fluid mixture is one that can easily change phase, a condensation shock would normally develop. Because of the overall rise in pressure in the diffuser as well as the additional rise in pressure across the shock layer, condensation becomes more likely. Associated with the pressure rise across the shock is a velocity reduction from the supersonic to the subsonic range. If the two-phase flow entering the diffuser is predominantly gaseous with liquid droplets suspended in it, it will transform into a predominantly liquid flow containing gaseous bubbles (bubbly flow) somewhere in the diffuser. While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the authors apart from that of Anand (1992) which accounted for condensation shocks. One of the objectives of this research effort is to develop a comprehensive model in which the effects of phase slip and inter-phase heat transfer as well as the wall friction and shock waves are accounted for. While this modeling effort is predominantly analytical in nature and is primarily intended to provide a parametric understanding of the jet pump performance under different operating scenarios, another parallel effort employing a commercial CFD code is also implemented. The latter effort is primarily intended to model an axisymmetric counterpart of the problem in question. The viability of using the CFD code to model a two-phase flow jet pump will be assessed by attempting to recreate some of the existing performance data of similar jet pumps. The code will eventually be used to generate the jet pump performance characteristics of several scenarios involving jet pump geometries as well as flow regimes in order to be able to determine an optimum design which would be suitable for a two-phase flow boiling test facility at NASA-Marshall. Because of the extensive nature of the analytical model developed, the following section will only provide very brief highlights of it, while leaving the details to a more complete report submitted to the NASA colleague. This report will also contain some of the simulation results obtained using the CFD code.

Sherif, S. A.↗

Modeling of a Two-Phase Jet Pump with Phase Change, Shocks and Temperature-Dependent Properties

One of the primary motivations behind this work is the attempt to understand the physics of a two-phase jet pump which constitutes part of a flow boiling test facility at NASA-Marshall. The flow boiling apparatus is intended to provide data necessary to design highly efficient two-phase thermal control systems for aerospace applications. The facility will also be capable of testing alternative refrigerants and evaluate their performance using various heat exchangers with enhanced surfaces. The test facility is also intended for use in evaluating single-phase performance of systems currently using CFC refrigerants. Literature dealing with jet pumps is abundant and covers a very wide array of application areas. Example application areas include vacuum pumps which are used in the food industry, power station work, and the chemical industry; ejector systems which have applications in the aircraft industry as cabin ventilators and for purposes of jet thrust augmentation; jet pumps which are used in the oil industry for oil well pumping; and steam-jet ejector refrigeration, to just name a few. Examples of work relevant to this investigation includes those of Fairuzov and Bredikhin (1995). While past researchers have been able to model the two-phase flow jet pump using the one-dimensional assumption with no shock waves and no phase change, there is no research known to the author apart from that of Anand (1992) who was able to account for condensation shocks. Thus, one of the objectives of this work is to model the dynamics of fluid interaction between a two-phase primary fluid and a subcooled liquid secondary fluid which is being injected employing atomizing spray injectors. The model developed accounts for phase transformations due to expansion, compression, and mixing. It also accounts for shock waves developing in the different parts of the jet pump as well as temperature and pressure dependencies of the fluid properties for both the primary two-phase mixture and the secondary subcooled liquid. The research effort on which this document partly reports described a relatively simple model capable of describing the performance of a two-phase flow jet pump. The model is based on the isentropic homogeneous expansion/compression hypothesis and is capable of fully incorporating the effects of shocks in both the mixing chamber and the throat/diffuser parts of the pump. The physical system chosen is identical to that experimentally tested by Fairuzov and Bredikhin (1995) and should therefore be relatively easy to validate.

Sherif, S. A.↗

Thermal Vibrational Convection in a Two-phase Stratified Liquid

The response of a two-phase stratified liquid system subject to a vibration parallel to an imposed temperature gradient is analyzed using a hybrid thermal lattice Boltzmann method (HTLB). The vibrations considered correspond to sinusoidal translations of a rigid cavity at a fixed frequency. The layers are thermally and mechanically coupled. Interaction between gravity-induced and vibration-induced thermal convection is studied. The ability of applied vibration to enhance the flow, heat transfer and interface distortion is investigated. For the range of conditions investigated, the results reveal that the effect of vibrational Rayleigh number and vibrational frequency on a two-phase stratified fluid system is much different than that for a single-phase fluid system. Comparisons of the response of a two-phase stratified fluid system with a single-phase fluid system are discussed.

Chang, Qingming↗

Adaptable Single Active Loop Thermal Control System (TCS) for Future Space Missions

This presentation will examine the development of a thermal control system (TCS) for future space missions utilizing a single active cooling loop. The system architecture enables the TCS to be reconfigured during the various mission phases to respond, not only to varying heat load, but to heat rejection temperature as well. The system will consist of an accumulator, pump, cold plates (evaporators), condenser radiator, and compressor, in addition to control, bypass and throttling valves. For cold environments, the heat will be rejected by radiation, during which the compressor will be bypassed, reducing the system to a simple pumped loop that, depending on heat load, can operate in either a single-phase liquid mode or two-phase mode. For warmer environments, the pump will be bypassed, enabling the TCS to operate as a heat pump. This presentation will focus on recent findings concerning two-phase flow regimes, pressure drop, and heat transfer coefficient trends in the cabin and avionics micro-channel heat exchangers when using the heat pump mode. Also discussed will be practical implications of using micro-channel evaporators for the heat pump.

two phase heat transfer↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database are investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components is used as an example in this study.

Daimaru, Takuro↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.

Daimaru, Takuro↗

Experimental, Computational, Theoretical and Analytical Investigation of Flow Boiling in Reduced Gravity

Two-phase thermal management systems are far superior to their single-phase counterparts because of their ability to capitalize on the coolant’s both sensible and latent heats, thereby yielding orders of magnitude higher heat transfer coefficients and smaller system footprints. A vital knowledge necessary for their implementation in future space systems is performance in microgravity. Long-duration microgravity experiments are necessary to obtain reliable databases, which would then be used to build reliable predictive tools. To achieve this goal, investigators at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center (NASA-GRC) have been collaborating towards the development of the Flow Boiling and Condensation Experiment (FBCE) and eventual execution onboard the International Space Station (ISS). FBCE has now matured to a point where it is ready for transport to the ISS, where first tests will be conducted using the Flow Boiling Module (FBM). In preparation for the ISS tests, a series of pre-launch Mission Sequence Tests (MSTs) was performed at GRC in Earth gravity with FBM mounted in a vertical upflow orientation using n-perfluorohexane as working fluid. The pre-launch tests included variations of flow rate, surface heat flux, inlet conditions, and both single-sided and double-sided wall heating. This presentation will summarize experimental results from these tests as well as both analytic and theoretical tools for prediction of two-phase heat transfer coefficient and critical heat flux (CHF). Also discussed will be an assessment of predictive accuracy of these tools against the experimental data.

Mission Sequence tests↗

Acoustic Insights into Flow Condensation Mechanisms

Two-phase thermal management systems, with both boiling and condensation processes, offer great potential and heat transfer coefficients that are orders of magnitude higher than traditional single-phase systems. However, two-phase flows can suffer from a wide range of interfacial instabilities leading to significant thermal performance degradation. In this study, we aim to detect regime transitions and characterize dominating physical mechanisms of flow condensation, such as turbulent diffusion in annular liquid film and interfacial waves, using an integrated system of acoustic, modal, and optical sensing techniques and thermofluidic characterizations. A wideband acoustic emissions sensor and high-sensitivity accelerometer are utilized to capture acoustic and vibrational signatures that signal the onset of liquid film formation and interfacial waves during flow pattern transitions. Compared to optical imaging, wideband acoustic emission sensing allows for higher sampling rates to capture high-frequency interface oscillations critical to the flow regime transitions and works well even for condensation in opaque tubes. Acoustic features (e.g., amplitude, frequency, energy, duration) are correlated with thermofluidic processes (e.g., capillary flows, turbulent flows, boiling, condensation). By relating thermal performance metrics with these dynamic signatures in acoustic and modal regimes, we explore the ability to probe and monitor critical flow regime transitions and transport efficiency in flow condensation.

Acoustic Modal Regimes↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗