Search NASA⌕ Search

SEARCH · Search NASA

Results for “STEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Generation of monodisperse droplets by spontaneous condensation of flow in nozzles

Submicron size monodisperse particles are of interest in many industrial and scientific applications. These include the manufacture of ceramic parts using fine ceramic particles, the production of thin films by deposition of ionized clusters, monodisperse seed particles for laser anemometry, and the study of size dependence of cluster chemical and physical properties. An inexpensive and relatively easy way to generate such particles is by utilizing the phenomenon of spontaneous condensation. The phenomenon occurs when the vapor or a mixture of a vapor and a noncondensing gas is expanded at a high expansion rate. The saturation line is crossed with the supercooled vapor behaving like a gas, until all of a sudden at the so called Wilson point, condensation occurs, resulting in a large number of relatively monodisperse droplets. The droplet size is a function of the expansion rate, inlet conditions, mass fraction of vapor, gas properties, etc. Spontaneous condensation of steam and water vapor and air mixture in a one dimensional nozzle was modeled and the resulting equations solved numerically. The droplet size distribution at the exit of various one dimensional nozzles and the flow characteristics such as pressure ratio, mean droplet radius, vapor and droplet temperatures, nucleation flux, supercooling, wetness, etc., along the axial distance were obtained. The numerical results compared very well with the available experimental data. The effect of inlet conditions, nozzle expansion rates, and vapor mass fractions on droplet mean radius, droplet size distribution, and pressure ratio were examined.

Lai, Der-Shaiun↗

Smoke Plume Analysis Using Fan-beam and Single-beam Radiometers

Smoke plume data were taken using the stacks of the Mills Road Steam Plant on Redstone Arsenal, Huntsville, Alabama. The fan-beam unit was placed approximately 235 meters east of the Mills Road Steam Plant, and the single-beam unit was placed approximately 80 meters north of the fan-beam unit. Results of the smoke plume measurements indicate that the smoke plume is a periodic process near the mouth of the smokestack. The usefulness of the system is limited because of inaccurate and cumbersome positioning methods and base line constraints due to cable length. It is recommended that the radiometers be mounted on pedestals which have both azimuth and elevation positions determined by digitally controlled stepper drive motors. It is also recommended that a time multiplex system be used to transmit data from the radiometers to the electronics van.

Dodd, J. L.↗

SiO2 Activity Measurements in the Gd2O3-SiO2 System Via Knudsen Effusion Mass Spectrometry (KEMS)

Environmental barrier coatings (EBCs) are required for the use of silicon carbide (SiC)-based ceramic matrix composites (CMCs) in gas turbine engines, as they protect the SiO 2 thermally grown oxide (TGO) formed at the CMC/coating interface from volatilization in a combustion environment. Current-generation EBCs consist of a silicon bond coat and a rare earth (RE) silicate topcoat. The RE silicate topcoat is exposed to high-velocity steam during engine operation, and SiO 2 within the coating can preferentially volatilize to form Si(OH) 4 gas species, albeit at a lesser degree than SiO 2 alone. Therefore, it is of interest to investigate the stability of these materials in steam as a function of their RE. In this study, SiO 2 activity, which can be related to the partial pressure of Si(OH) 4 , was measured across the Gd 2 O 3 -SiO 2 phase diagram, which includes Gd 2 SiO 5 , Gd 9.33 (SiO 4 ) 6 O 2 , and Gd 2 Si 2 O 7 as line compounds, via Knudsen Effusion Mass Spectrometry (KEMS). Values obtained for the Gd 2 O 3 -SiO 2 system were compared to those of other RE2O3-SiO2 systems and contextualized in terms of EBC viability.

EBCs↗

Solid oxide fuel cell power plant having a bootstrap start-up system

The bootstrap start-up system (42) achieves an efficient start-up of the power plant (10) that minimizes formation of soot within a reformed hydrogen rich fuel. A burner (48) receives un-reformed fuel directly from the fuel supply (30) and combusts the fuel to heat cathode air which then heats an electrolyte (24) within the fuel cell (12). A dilute hydrogen forming gas (68) cycles through a sealed heat-cycling loop (66) to transfer heat and generated steam from an anode side (32) of the electrolyte (24) through fuel processing system (36) components (38, 40) and back to an anode flow field (26) until fuel processing system components (38, 40) achieve predetermined optimal temperatures and steam content. Then, the heat-cycling loop (66) is unsealed and the un-reformed fuel is admitted into the fuel processing system (36) and anode flow (26) field to commence ordinary operation of the power plant (10).

30 DIRECT ENERGY CONVERSION↗

Characterization of SiO 2 Thermally Grown Oxide Stress Evolution of EBCs with Al-Containing Dopants

SiC/SiC ceramic matrix composites (CMCs) are desired for use in combustion environments to achieve higher turbine operating temperatures. However, CMCs require environmental barrier coatings (EBCs) for protection from the gas environment. EBC systems are known to primarily fail through coating delamination via growth of a thermally grown oxide (TGO) at the EBC—silicon bond coating interface when exposed to steam, which accelerates the TGO growth rate. The TGO undergoes a phase transformation during thermal cycling, which results in stresses that may encourage EBC spallation. Yb-silicate EBCs with mullite and yttrium aluminum garnet (YAG) dopant additions were deposited on SiC substrates with a Si intermediate bond coating and exposed to thermal cycling in steam at 1350 °C. The impact of Al dopant additions on the TGO growth rate and the SiO 2 phase transformation was assessed. Photo-stimulated luminescence spectroscopy (PSLS) was used to characterize the Al-containing phases and to measure stress evolution in the EBC following exposure using the stress-induced peak shift of the R-lines of mullite. Raman microscopy was used to map the stresses in the Si bond coating following exposure. It was found that the TGO phase transformation upon cooling increased compressive stress in the Si bond coating within 15 µm of the TGO.

Building Materials↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Storage Glass Development

Halotechnics, Inc.develops novel high temperature fluids and phase change materials, and designs modular salt storage tanks, as well as full thermal systems, for waste heat capture, grid-scale electricity storage, concentrated solar power, and other energy and efficiency applications. Using combinatorial chemistry techniques, Halotechnics has developed a variety of salts and other oxide compositions. Halotechnics’s molten fluids product line offers salt and oxide glass products that can be used in temperature ranges spanning from 50°C to 1200°C. The properties of these various materials are appropriate for both sensible heat and latent heat thermal energy storage applications. The thermal energy stored in the materials can be converted to electricity by various methods, including direct conversion using thermoelectric generation, or indirectly, by heating steam and running a turbine. LBL has materials characterization equipment that is useful for Halotechnics to achieve its materials development goals. Through the CalCharge agreement with LBL, Halotechnics worked with an LBL principal investigator to access this equipment, and to jointly design experimental procedures for unusual measurements.

25 ENERGY STORAGE↗

SO2 Plumes Observation with LMOL: Theory, Modeling, and Validation

LMOL, the NASA Langley Mobile Ozone Lidar, is locatednear NASA’s LaRC steam plant when not deployed in campaigns. Theplant produces steam through the incineration of local trash, and itsexhaust plume occasionally contains SO2.SO2is a known, regulated, pollutant that affects O3observations in theUV, as is the case with LMOL. In this work, we show how we modifiedLMOL to detect the plant SO2plumes and compute its density when theO3background is stable; we observed densities compatible with what isexpected from the typical plume exhaust. The selection of laser lines sothat an O3variation would not get confused with a SO2detection isexplained in details, and a model capable of simulating the Lidar signalwith (notably) O3and SO2absorption for the validation of the retrievalresolution and uncertainty is presented. Finally, the comparison betweenthe modeled and observed performances of the system is shown: themaximum altitude, resolution, and error in the modeled signal and theobserved signals are the same within reasonable margins.This work demonstrates that LMOL is fully capable of working withSO2. The next step being the addition of an additional laser channel,which is simplified by the tunable aspect of the LMOL laser, to addressO3and SO2simultaneously, allowing the assessment of SO2when O3has variations.

Guillaume Gronoff↗

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.↗

A Snowball in Hell: The Potential Steam Atmosphere of TOI-1266c

The recent discovery of two planets orbiting TOI-1266 (Stef nsson et al., 2020) offers a rare opportunity to begin observing the simultaneous impacts of both a planet and host star evolving through time. While both planets’ masses are poorly constrained at present, planet c could ultimately fall into one of several categories, including that of a super-Venus or a warm sub-Neptune. This latter scenario would mean that TOI-1266c could still have a substantial water inventory if it originally formed beyond the ice line and migrated to its present location. If so, then planet c would be a long-lived analogue of Venus during its runaway greenhouse state, which is thought to have lasted millions of years (e.g., Zahnle & Kasting, 1986).

C. E. ‘Sonny’ Harman↗

Space Shuttle RCS Oxidizer Leak Repair for STS-26

Following propellant loading of the Space Shuttle's reaction control system (RCS) for mission STS 26, an oxidizer leak was detected in the left orbital maneuvering system (OMS) pod, where the RCS is located. Subsequent investigation determined that the leak was isolated at a mechanical Dynatube fitting near the RCS nitrogen tetroxide tank. An intense effort was initiated to design, fabricate, and qualify a sealing device to stop the oxidizer leak externally so that the Space Shuttle launch could proceed. It was discovered that sealing devices called clamshells were widely used throughout the petrochemical and power generation industries to stop leaks developed in large diameter pipes which carry steam or other hazardous fluids. These clamshells are available in different diameters and strengths and are placed around the pipe at the location of the leak. A sealing compound is then injected under high pressure into the clamshell to stop the leak. This technology was scaled down and applied to the problem of stopping the leak on the Orbiter, which was on a half-inch diameter line in a nearly inaccessible location. Many obstacles had to be overcome such as determining that the sealing material would be compatible with the nitrogen tetroxide and ensuring that the clamshell would actually fit around the Dynatube fitting without interfering with other lines which were in close proximity. The effort at the NASA Johnson Space Center included materials compatibility testing of several sealants, design of a clamshell to fit in the confined compartment, and manufacture and qualification of the flight hardware. A clamshell was successfully placed around the Dynatube fitting on the Orbiter and the oxidizer leak was terminated. Then it was decided to apply this technology further and design clamshells for other mechanical fittings onboard the Orbiter and develop sealing compounds which will be compatible with fuels such as monomethyl hydrazine (MMH). The potential exists for using this type of sealing device in numerous other applications throughout the aerospace industry.

Delventhal, R. A.↗

Preliminary LOCA analysis of the westinghouse small modular reactor using the WCOBRA/TRAC-TF2 thermal-hydraulics code

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) with all primary components, including the steam generator and the pressurizer located inside the reactor vessel. The reactor core is based on a partial-height 17x17 fuel assembly design used in the AP1000{sup R} reactor core. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. A preliminary loss of coolant accident (LOCA) analysis of the Westinghouse SMR has been performed using the WCOBRA/TRAC-TF2 code, simulating a transient caused by a double ended guillotine (DEG) break in the direct vessel injection (DVI) line. WCOBRA/TRAC-TF2 is a new generation Westinghouse LOCA thermal-hydraulics code evolving from the US NRC licensed WCOBRA/TRAC code. It is designed to simulate PWR LOCA events from the smallest break size to the largest break size (DEG cold leg). A significant number of fluid dynamics models and heat transfer models were developed or improved in WCOBRA/TRAC-TF2. A large number of separate effects and integral effects tests were performed for a rigorous code assessment and validation. WCOBRA/TRAC-TF2 was introduced into the Westinghouse SMR design phase to assist a quick and robust passive cooling system design and to identify thermal-hydraulic phenomena for the development of the SMR Phenomena Identification Ranking Table (PIRT). The LOCA analysis of the Westinghouse SMR demonstrates that the DEG DVI break LOCA is mitigated by the injection and venting from the Westinghouse SMR passive safety systems without core heat up, achieving long term core cooling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advancements in Development and Testing of Thermal Power Dispatch Simulators

Flexible plant operations and generation (FPOG) offer nuclear power plants (NPPs) the chance to leverage alternative, non-electric revenue streams while ensuring their continued role as reliable, clean, and constant sources of baseload electrical power. The excess thermal energy generated from NPPs during periods of low electricity demand can be channeled as raw materials to numerous industrial processes via a thermal power dispatch (TPD) system. Hydrogen production via high-temperature steam electrolysis (HTSE) is an optimal use case based on technical and economic feasibility. Researchers at Idaho National Laboratory (INL) have conducted previous works that developed and implemented TPD system models within the GSE Solutions Generic Pressurized Water Reactor (GPWR) simulator to support human-in-the-loop (HITL) scenario-based evaluations. The first part of this report documents modifications made to the GPWR TPD model and HMI from the previous iteration in line with a new Sargent and Lundy (S&L) TPD design with an automatic control system. The was done in collaboration with Westinghouse using their three-loop pressurizer water reactor (W3LPWR) simulator which contains an industrial grade automatic control system for the TPD. This was installed in the Human Systems Simulation Laboratory (HSSL) at INL. The second part of the report documents findings from an all-hands-on-deck integration and verification workshop that was conducted in the HSSL over several days. The research team comprised INL human factors and TPD experts, a nuclear engineer from GSE Solutions who implemented the revised TPD model for GPWR, the human-machine interface (HMI) prototyping and human factors team from the University of Idaho, and personnel with operations experience with pressurized water reactors. The workshop provided time and expertise to conduct the final activities to bring the operations, HMI, and simulator into a functional state. The goals of the integration and verification workshop were: 1. to install the revised GPWR TPD model into the HSSL 2. verify the TPD HMI prototype was functional 3. integrate the HTSE Simulink model to GPWR. 3. Issues were identified for resolution, but overall the workshop accomplished its goal to integrated and verify the majority of the intended functional. Future work will resolve the identified issues and use the integrated simulation to support an evaluation and demonstration in the next fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Learning Design at White Sands Test Facility

During the Fall of 2010, I spent my time at NASA White Sands Test Facility in Las Cruces, NM as an Undergraduate Student Research Program (USRP) Intern. During that time, I was given three projects to work on: Large Altitude Simulation System (LASS) basket strainer, log books, and the design of a case for touch screen monitors used for simulations. I spent most of my time on the LASS basket strainer. The LASS system has a water feed line with a basket strainer that filters out rust. In 2009, there were three misfires which cost approximately $27,000 and about 8% of the allotted time. The strainer was getting a large change in pressure that would result in a shutdown of the system. I have designed a new basket that will eliminate the large pressure change and it can be used with the old basket strainer housing. The LASS system has three steam generators (modules). Documents pertaining to these modules are stored electronically, and the majority of the documents are not able to be searched with keywords, so they have to be gone through one by one. I have come up with an idea on how to organize these files so that the Propulsion Department may efficiently search through the documents needed. Propulsion also has a LASS simulator that incorporates two touch screen monitors. Currently these monitors are in six foot by two foot metal cabinet on wheels. During simulation these monitors are used in the block house and need to be taken out of the block house when not in use. I have designed different options for hand held cases for storing and transporting the monitors in and out of the block house. The three projects previously mentioned demonstrate my contributions to the Propulsion Department and have taught me real world experience that is essential in becoming a productive engineer.

Grotewiel, Shane↗

SO2 Plumes Observation with LMOL: Theory, Modeling, and Validation

LMOL, the NASA Langley Mobile Ozone Lidar, is located near NASA’s LaRC steam plant when not deployed in campaigns. The plant produces steam through the incineration of local trash, and its exhaust plume occasionally contains SO2 . SO2 is a known, regulated, pollutant that affects O3 observations in the UV, as is the case with LMOL. In this work, we show how we modified LMOL to detect the plant SO2 plumes and compute its density when the O3 background is stable; we observed densities compatible with what is expected from the typical plume exhaust. The selection of laser lines so that an O3 variation would not get confused with a SO2 detection is explained in details, and a model capable of simulating the Lidar signal with (notably) O3 and SO2 absorption for the validation of the retrieval resolution and uncertainty is presented. Finally, the comparison between the modeled and observed performances of the system is shown: the maximum altitude, resolution, and error in the modeled signal and the observed signals are the same within reasonable margins. This work demonstrates that LMOL is fully capable of working with SO2 . The next step being the addition of an additional laser channel, which is simplified by the tunable aspect of the LMOL laser, to address O3 and SO2 simultaneously, allowing the assessment of SO2 when O3 has variations. Note: This presentation is accompanied by an mp4 video of the given talk.

Guillaume Gronoff↗

Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

Currently, geothermal project developers customize the size of the power plant to fit the resource being developed. The turbine is designed and sized to optimize efficiency and resource utilization for electricity production; most often, other power plant components are then chosen to complement the turbine design. These custom turbine designs demand one-off manufacturing processes, which result in higher manufacturing setup costs, longer lead-times, and higher capital costs overall in comparison to larger-volume line manufacturing processes. In contrast, turbines produced in standard increments, manufactured in larger volumes, could result in lower costs per turbine. In this study, we developed a manufacturing cost model to identify requirements for equipment, facilities, raw materials, and labor. Then we used discounted cash flow (DCF) analysis to calculate the minimum sustainable price (MSP). We analyzed three different cases 1) 1 MWe geothermal ORC turboexpander 2) 5 MWe ORC turboexpander and 3) 20 MWe geothermal steam turbine, and calculated the cost of manufacturing the major components, such as the impellers/blades, shaft/rotor, nozzles, inlet guide lanes, disks, and casings. The results showed that MSP could highly vary between 893 /kW and 30 /kW based on turbine size, standardization and volume of manufacturing. The analysis also showed that the economy of scale applies both to the size of the turbine and the number manufactured in a single run. As an example, the unit price of a 5 MW standard design turbine could be 150 /W cheaper than the custom design. Sensitivity analysis indicated that these savings come largely from reduced labor costs for design and engineering and manufacturing setup. In addition to manufacturing cost savings, there is a delivery time saving up to 10 months, which could have a positive effect to construction financing operation time. Another advantage of these standard turbines is their adaptability to different geothermal systems by operating at off-design conditions. We also modeled off-design turbine efficiencies within the commercially-favorable operating range of a standard ORC compared to custom-designed ORC equipment. Than we used these performance calculations and power output capacities in a discounted cash flow (DCF) analysis of plant operations and financing, thereby creating representative techno economic models of a total geothermal power plant. I this scope we used NREL's System Advisor model (SAM) and performed DCF analysis of standard and custom design turbines using results from IPSEpro over range of temperatures of interest. In this scope 63 different off-design cases were analyzed. This helped us to answer the question; 'Can today's capital cost savings compensate the future revenue losses due to lower electricity generation?' The results showed that, the net capital cost savings for the modeled 5 MW case study may reach up to plus 1,298,672. Also, the difference between NPV of standard design and custom design turbine could reach up to 733,940. To sum up, when all the things mentioned above are taken into consideration, it can be said that, the standard turbines are competitive over a wide range of temperatures and flow rates and the give positive NPV differences for certain cases near their design point.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2018 Research Highlight in Manufacturing: Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

Currently, geothermal project developers customize the size of the power plant to fit the resource being developed. The turbine is designed and sized to optimize efficiency and resource utilization for electricity production; most often, other power plant components are then chosen to complement the turbine design. These custom turbine designs demand one-off manufacturing processes, which result in higher manufacturing setup costs, longer lead-times, and higher capital costs overall in comparison to larger-volume line manufacturing processes. In contrast, turbines produced in standard increments, manufactured in larger volumes, could result in lower costs per turbine. In this study, we developed a manufacturing cost model to identify requirements for equipment, facilities, raw materials, and labor. Then we used discounted cash flow (DCF) analysis to calculate the minimum sustainable price (MSP). We analyzed three different cases 1) 1 MWe geothermal ORC turboexpander 2) 5 MWe ORC turboexpander and 3) 20 MWe geothermal steam turbine, and calculated the cost of manufacturing the major components, such as the impellers/blades, shaft/rotor, nozzles, inlet guide lanes, disks, and casings. The results showed that MSP could highly vary between 893 $/kW and 30 $/kW based on turbine size, standardization and volume of manufacturing. The analysis also showed that the economy of scale applies both to the size of the turbine and the number manufactured in a single run. As an example, the unit price of a 5 MW standard design turbine could be 150 $/W cheaper than the custom design. Sensitivity analysis indicated that these savings come largely from reduced labor costs for design and engineering and manufacturing setup. In addition to manufacturing cost savings, there is a delivery time saving up to 10 months, which could have a positive effect to construction financing operation time. Another advantage of these standard turbines is their adaptability to different geothermal systems by operating at off-design conditions. We also modeled off-design turbine efficiencies within the commercially-favorable operating range of a standard ORC compared to custom-designed ORC equipment. Than we used these performance calculations and power output capacities in a discounted cash flow (DCF) analysis of plant operations and financing, thereby creating representative techno economic models of a total geothermal power plant. I this scope we used NREL's System Advisor model (SAM) and performed DCF analysis of standard and custom design turbines using results from IPSEpro over range of temperatures of interest. In this scope 63 different off-design cases were analyzed. This helped us to answer the question; 'Can today`s capital cost savings compensate the future revenue losses due to lower electricity generation?' The results showed that, the net capital cost savings for the modeled 5 MW case study may reach up to +$1,298,672. Also, the difference between NPV of standard design and custom design turbine could reach up to +$733,940. To sum up, when all the things mentioned above are taken into consideration, it can be said that, the standard turbines are competitive over a wide range of temperatures and flow rates and the give positive NPV differences for certain cases near their design point.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flow studies in a wet steam turbine

The design and test results of a four stage wet vapor turbine operating with slightly superheated inlet steam and expanding to 10% exit moisture are presented. High speed movies at 3000 frames per second of liquid movement on the pressure side and along the trailing edge of the last stator blade are discussed along with back lighted photographs of moisture drops as they were torn from the stator blade trailing edge. Movies at lower framing rates were also taken of the exit of the last rotating blade and the casing moisture removal slot located in line with the rotor blade shroud. Also moisture removal data are presented of casing slot removal at the exit of the third and fourth rotor blades and for slots located in the trailing edge of the last stator blade. Finally, the degradation of turbine thermodynamic performance due to condensation formation and movement is discussed.

Evans, D. H.↗