Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

A cleanroom in a glovebox

The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system that allows for the fabrication and characterization of devices in an inert argon atmosphere. Additionally, we demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Finally, we discuss the custom-built antechamber attached to the back of the glovebox. This antechamber allows the glovebox to interface with ultra-high vacuum equipment such as molecular-beam epitaxy and scanning tunneling microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-Field Alpha Spectrometry to Assess Uranium Enrichment In Uranium Hexafluoride

A new In-Field Alpha Spectrometry (IFAS) system is being developed to allow quick turnaround measurements of uranium enrichment in uranium hexafluoride (UF6) samples. Samples are collected using specially-designed Single-Use Destructive Assay (SUDA) wafers which have an absorptive film of zeolite deposited onto a quartz or metal substrate. The SUDA samples, along with a special holder, are designed to be attached directly to a sampling tap at a gas centrifuge enrichment plant or a uranium conversion facility, allowing gaseous UF6 to come into direct contact with the zeolite. The zeolite absorbs this material and converts it into stable, safe UO2F2 within a few minutes. Once the sample has been collected it is transferred to the IFAS system where a solid-state, silicon alpha spectrometer is used to quantitatively measure the alpha emissions from 234U, 235U, and 238U in the sample. The IFAS system is a small, light-weight device that can be quickly turned on and put into use. The SUDA samples and IFAS hardware are designed so that thin-film spectra are produced, allowing a complete measurement with a final 235U:Utotal determination having a precision <±2% to be made in less than eight hours. This short time frame will allow an inspector to get results on-site within one working shift; further innovations may reduce this to even shorter times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sampling frequency thresholds for the quantum advantage of the quantum approximate optimization algorithm

We compare the performance of the Quantum Approximate Optimization Algorithm (QAOA) with state-of-the-art classical solvers Gurobi and MQLib to solve the MaxCut problem on 3-regular graphs. We identify the minimum noiseless sampling frequency and depth p required for a quantum device to outperform classical algorithms. There is potential for quantum advantage on hundreds of qubits and moderate depth with a sampling frequency of 10 kHz. We observe, however, that classical heuristic solvers are capable of producing high-quality approximate solutions in linear time complexity. In order to match this quality for large graph sizes N, a quantum device must support depth p > 11. Additionally, multi-shot QAOA is not efficient on large graphs, indicating that QAOA p ≤ 11 does not scale with N. These results limit achieving quantum advantage for QAOA MaxCut on 3-regular graphs. Other problems, such as different graphs, weighted MaxCut, and 3-SAT, may be better suited for achieving quantum advantage on near-term quantum devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of dislocation-related and point-defects in III-As layers for silicon photonics applications

Abstract The aim of this paper is to identify, analyze and compare the defects present in III-As, as a function of dislocation density, and as a function of the presence/absence of quantum dots (QDs). Such materials are of fundamental importance for the development of lasers and photodiodes for silicon photonics. The study is based on an extensive deep-level transient spectroscopy investigation, carried out on GaAs pin diodes grown on Si and on GaAs (that differ in the dislocation density), with and without embedded QDs. The original results described in this paper demonstrate that: (a) we were able to identify four different defects within the device grown on Si (three electron and one hole traps) and one defect (hole trap) in the device on GaAs, common to both samples; (b) all the majority carrier traps identified are located near midgap, i.e. are efficient non-radiative recombination centers; (c) such defects are absent (or non-detectable) in the sample grown on GaAs substrate, having a very low dislocation density; (d) the presence of QDs does not result in additional defects within the semiconductor material; (e) the analysis of the capture kinetics revealed that two of the identified traps are related to point defects, whereas the other two traps can be associated with point defects located near a dislocation; (f) a comparison with previous reports indicate that the detected traps are related to native III-As defects, or to oxygen-related complexes.

Physics↗

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Affordable, accurate, and robust temporal measurement devices are desirable for screening and assessment of radon levels in private homes and workplaces. This research expands upon prior research, using the RadonFTlab RadonEye device through a comparison of multiple samples of this instrument with a laboratory-grade instrument, the Saphymo AlphaGUARD, over a more extensive period than reported previously. Data were collected over 291 d in a poorly ventilated basement space in an occupied building. Environmental conditions varied naturally, changing both the radon source term and radon entry into the space approximating typically deployed conditions. The R-squared linear regression correlation coefficient and relative sensitivities of each RadonEye with the AlphaGUARD were computed. Altogether temporal and diurnal variations were also studied. The sensitivities of all RadonEyes and the AlphaGUARD agreed to within 22% throughout the entire deployment period.

47 OTHER INSTRUMENTATION↗

Handheld Raman Spectrometers: Assessment Report

In April 2022 the National Urban Security Technology Laboratory’s System Assessment and Validation for Emergency Responders program conducted an operational assessment of ten commercially available handheld Raman spectrometers. Additionally, prior to the operational assessment, the Pacific Northwest National Laboratory conducted laboratory testing of the devices, including scanning a number of samples in various containers. This report summarizes the results of the assessment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comprehensive Analysis of Real-World Accelerometer Data Quality in a Global Smartphone-based Seismic Network

The proliferation of low-cost sensors in smartphones has facilitated numerous applications; however, large-scale deployments often encounter performance issues. Sensing heterogeneity, which refers to varying data quality due to factors such as device differences and user behaviors, presents a significant challenge. In this research, we perform an extensive analysis of 3-axis accelerometer data from the MyShake system, a global seismic network utilizing smartphones. We systematically evaluate the quality of approximately 22 million 3-axis acceleration waveforms from over 81 thousand smartphone devices worldwide, using metrics that represent sampling rate and noise level. We explore a broad range of factors influencing accelerometer data quality, including smartphone and accelerometer manufacturers, phone specifications (release year, RAM, battery), geolocation, and time. Our findings indicate that multiple factors affect data quality, with accelerometer model and smartphone specifications being the most critical. In addition, we examine the influence of data quality on earthquake parameter estimation and show that removing low-quality accelerometer data enhances the accuracy of earthquake magnitude estimation.

58 GEOSCIENCES↗

Software Requirements for a Sample Check-in application in CBRNResponder

In 2021, functional area drills were held that focused on field sample collection and custody transfer at the sample control hotline for the Radiological Assistance Program (RAP) Consequence Management (CM) program. The overarching goal of these drills were to evaluate the current CM processes using the CBRNResponder mobile and web-based applications. There were several needs identified to improve CM processes and to stream/transfer data across multiple devices with and without internet: (1) A sample check-in process is needed to streamline current processes to reduce errors and create efficiencies, (2) the sample check-in application needs to be deployed as a mobile application and on the browser versions when on-line, and (3) the sample check-in process needs to function in an environment with internet connections and also in a standalone mode when internet is not available.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. An example method for operating an integrated thermal cycling system includes depositing samples into the integrated thermal cycling system that includes a thermal cycling device and an electronic interface. The thermal cycling device includes multiple wells to receive the samples to be thermally cycled, a thermoelectric cooling (TEC) element connected to the multiple wells, a substrate on which the TEC element is positioned, and a controller coupled to the TEC element. The multiple wells are positioned within the substrate that includes a thermally conductive ground positioned between adjacent wells. Supplying power to the integrated thermal cycling system, via the electronic interface, allows the multiple wells to exchange heat with the substrate and for each well to operate independently from other wells.

Beer, N. Reginald↗

TTW (Transition to Wire Device) [SWR-25-02]

The Transition to Wire (TTW) hardware project is a method for connecting solar research samples with fragile interconnects to robust, weatherproof and consistent commercial connectors. The Transition to Wire device is a printed circuit board designed to facilitate the transition from tab ribbon or other unsecured electrical contacts on research samples to either wires or a connector. The four pin connector provides a kelvin (4 wire) connection at the solder pad where the sample connects.

McDanold, Byron↗

Bile salt hydrolase probe and method of making and using the same

Probe embodiments for targeting, identifying, and isolating enzymes exhibiting BSH activity as well as devices and kits that use the probes are described herein. Methods of making and using the probes, devices, and kits are also described. In some embodiments, probes, devices, and kits for targeting, identifying, and isolating enzymes in a biological sample are disclosed. In some embodiments, compositions and methods of treatment using the probes, devices, and kits disclosed herein are described.

Wright, Aaron T.↗

Laser ablation spectrometry system

This disclosure provides systems, methods, and apparatus related to laser ablation spectrometry systems. In one aspect, a system comprises a microscope, a laser, a continuous flow probe, and a gas confinement device. The laser is positioned to emit light through an objective lens of the microscope. The continuous flow probe is coupled to a spectrometer. An end of the continuous flow probe is positioned proximate a sample and between the sample and the objective lens. The gas confinement device defines a gas inlet, a chamber, a platform, a wall surrounding the platform, a plurality of vents, and a plurality of channels. Each of the plurality of vents is positioned to direct a gas substantially parallel to the platform, and each of the plurality of vents is defined in the wall. The plurality of channels is operable to provide fluid communication between the chamber and the plurality of vents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning SQUID characterization of extremely overdoped La 2-x Sr x CuO 4

Recently, advances in film synthesis methods have enabled a study of extremely overdoped La 2 - x Sr x Cu O 4 . This has revealed a surprising behavior of the superfluid density as a function of doping and temperature, the explanation of which is vividly debated. One popular class of models posits electronic phase separation, where the superconducting phase fraction decreases with doping, while some competing phase (e.g., ferromagnetic) progressively takes over. A problem with this scenario is that all the way up to the dome edge the superconducting transition remains sharp, according to mutual inductance measurements. However, the physically relevant scale is the Pearl penetration depth Λ P , and this technique probes the sample on a length scale L that is much larger than Λ P . In the present paper, we use local scanning superconducting quantum interference device (SQUID) measurements that probe the susceptibility of the sample on the scale L << Λ P . Our SQUID maps show uniform landscapes of susceptibility and excellent overall agreement of the local penetration depth data with the bulk measurements. Overall, these results contribute an important piece to the puzzle of how high-temperature superconductivity vanishes on the overdoped side of the cuprate phase diagram.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature Dependent Spin Dynamics in La 0.67 Sr 0.33 MnO 3 /Pt Bilayers

Complex ferromagnetic oxides such as La 0.67 Sr 0.33 MnO 3 (LSMO) offer pathways for creating energy‐efficient spintronic devices with new functionalities. LSMO exhibits high‐temperature ferromagnetism, half metallicity, sharp resonance linewidth, low damping, and a large anisotropic magnetoresistance response. Combined with Pt, a proven material with high spin‐charge conversion efficiency, LSMO can be used to create robust nano‐oscillators for neuromorphic computing. Ferromagnetic resonance (FMR) and device‐level spin‐pumping FMR measurements are performed to investigate the magnetization dynamics and spin transport in NdGaO 3 (110)/LSMO(15 nm)/Pt(0 and 5 nm) thin films ranging from 300 K to 90 K and compare the device performance with Py(7 nm)/Pt(5 nm) sample. The spin current pumped into Pt is quantified to determine the temperature‐dependent influence of interfacial interactions. The generated spin current in the micro‐device is maximum at 170 K for the optimally grown LSMO/Pt films. Additionally, this bilayer system exhibits low magnetic Gilbert damping (0.002), small linewidth (12 Oe), and a large spin Hall angle (≈3.2%) at 170 K. Ex situ deposited LSMO/Pt bilayers demonstrate excellent dynamic response, exhibiting fourfold enhancement in signal output, eightfold reduction in damping, and a threefold reduction in linewidth as compared to the Pt/Py system. Such robust device‐level performance can pave way for energy‐efficient spintronic‐based devices.

complex perovskite thin films↗

Democratization of fungal highway columns as a tool to investigate bacteria associated with soil fungi

ABSTRACT Bacteria–fungi interactions (BFIs) are essential in ecosystem functioning. These interactions are modulated not only by local nutritional conditions but also by the physicochemical constraints and 3D structure of the environmental niche. In soils, the unsaturated and complex nature of the substrate restricts the dispersal and activity of bacteria. Under unsaturated conditions, some bacteria engage with filamentous fungi in an interaction (fungal highways) in which they use fungal hyphae to disperse. Based on a previous experimental device to enrich pairs of organisms engaging in this interaction in soils, we present here the design and validation of a modified version of this sampling system constructed using additive printing. The 3D printed devices were tested using a novel application in which a target fungus, the common coprophilous fungus Coprinopsis cinerea, was used as bait to recruit and identify bacterial partners using its mycelium for dispersal. Bacteria of the genera Pseudomonas, Sphingobacterium and Stenotrophomonas were highly enriched in association with C. cinerea. Developing and producing these new easy-to-use tools to investigate how bacteria overcome dispersal limitations in cooperation with fungi is important to unravel the mechanisms by which BFIs affect processes at an ecosystem scale in soils and other unsaturated environments.

54 ENVIRONMENTAL SCIENCES↗