Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Alignment of low-dose X-ray fluorescence tomography images using differential phase contrast

X-ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross-correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross-correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced-dose, more rapidly acquired, fluorescence nanotomography experiments.

differential phase contrast↗

Robust Recovery of Temporally Smooth Signals From Under-Determined Multiple Measurements

In this study, we consider the problem of recovering jointly sparse vectors from underdetermined measurements that are corrupted by both additive noise and outliers. This can be viewed as the robust extension of the Multiple Measurement Vector (MMV) problem. To solve this problem, we propose two general approaches. As a benchmark, the first approach preprocesses the input for outlier removal and then employs state-of-the-art technologies for signal recovery. The second approach, as the main contribution of this paper, is based on formulation of an innovative regularized fitting problem. By solving the regularized fitting problem, we jointly remove outliers and recover the sparse vectors. Furthermore, by exploiting temporal smoothness among the sparse vectors, we improve noise robustness of the proposed approach and avoid the problem of over-fitting. Extensive numerical results are provided to illustrate the excellent performance of the proposed approach.

47 OTHER INSTRUMENTATION↗

The inverse problem of estimating the gravitational time dilation

Precise testing of the gravitational time dilation effect suggests comparing the clocks at points with different gravitational potentials. Such a configuration arises when radio frequency standards are installed at orbital and ground stations. The ground-based standard is accessible directly, while the spaceborne one is accessible only via the electromagnetic signal exchange. Reconstructing the current frequency of the spaceborne standard is an ill-posed inverse problem whose solution depends significantly on the characteristics of the stochastic electromagnetic background. The solution for Gaussian noise is known, but the nature of the standards themselves is associated with nonstationary fluctuations of a wide class of distributions. A solution is proposed for a background of flicker fluctuations with a spectrum (1/f){sup γ}, where 1 < γ < 3, and stationary increments. The results include formulas for the error in reconstructing the frequency of the spaceborne standard and numerical estimates for the accuracy of measuring the relativistic redshift effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the inclusive and differential production cross sections of a top-quark–antiquark pair in association with a Z boson at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Measurements of both the inclusive and differential production cross sections of a top-quark–antiquark pair in association with a Z boson ($t\bar{t}Z$) are presented. The measurements are performed by targeting final states with three or four isolated leptons (electrons or muons) and are based on $\sqrt{s}$=13 TeV proton–proton collision data with an integrated luminosity of 139 fb -1 , recorded from 2015 to 2018 with the ATLAS detector at the CERN Large Hadron Collider. The inclusive cross section is measured to be σ $t\bar{t}Z$ =0.99 ± 0.05 (stat.) ± 0.08 (syst.) pb, in agreement with the most precise theoretical predictions. The differential measurements are presented as a function of a number of kinematic variables which probe the kinematics of the $t\bar{t}Z$ system. Both absolute and normalised differential cross-section measurements are performed at particle and parton levels for specific fiducial volumes and are compared with theoretical predictions at different levels of precision, based on a χ 2 /ndf and p value computation. Overall, good agreement is observed between the unfolded data and the predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

From Bombs to Breast Cancer Imaging: Los Alamos National Laboratory

In the United States, one in eight women will be affected by breast cancer. According to the American Cancer Society, breast cancer is the most commonly diagnosed - as well as the second most fatal - cancer in American women. It is estimated that there will be nearly 200,000 diagnoses of breast cancer this year; more than 40,000 of these will be fatal. Although advances in medical technologies have greatly increased the odds of surviving the disease, the increase in screenings has not resulted in a significant reduction in the breast cancer mortality rate. Moreover, recent studies have even suggested that an increase in these methods might, in itself, cause cancer. A new tool for early detection and diagnosis of breast cancer, supported by an award from the Breast Cancer Research Program (BCRP) of the Congressionally Directed Medical Research Programs of Department of Defense, could give women a new advantage in the fight against breast cancer. This LANL-led project will integrate ultrasound tomography (UST) with recent discoveries in the field of cell and tissue biomechanics to improve breast cancer detection and characterization. UST uses ultrasound waves instead of X-rays to identify and characterize breast tumors. This technology reveals small mechanical-property changes within the breast. These changes are often the earliest signs of breast cancer. Additionally, UST is effective for women with dense breast tissue, who have a higher risk of developing breast cancer. Because the technology does not use radiation, UST can also be used as frequently as needed for women with a high risk of developing breast cancer. In contrast, mammography, the only routine breast-cancer screening tool currently available, is not effective for women with dense breast tissue and may come with unwanted side-effects caused by ionizing radiation. UST has great potential to become an alternative breast-cancer screening tool because of UST's advantages and benefits over mammography. Currently, there is fierce debate surrounding the age at which breast cancer screening should begin, and once begun, how often it should occur. The American Cancer Society recommends yearly mammograms starting at age 40. On the other hand, the U.S. Preventive Services Task Force recommends against routine so early. Rather, the Task Force recommends biennial mammography screening for women aged 50 to 74 years. The ten-year discrepancy in the onset of screening results from recent data suggesting that the frequent use of X-ray radiation during screenings could potentially increase the likelihood of developing cancer. This danger is increased by the low sensitivity and accuracy of mammograms, which sometimes require multiple screenings to yield results. Furthermore, mammograms are often not only inaccurate, but average appalling misdiagnoses rates: about 80% false positives and 15% false negatives. These misdiagnoses lead to unwarranted biopsies at an estimated health care cost of $2 billion per year, while at the same time, resulting in excessive cases of undetected cancer. As such, the National Cancer Institute recommends more studies on the advantages of types and frequency of screenings, as well as alternative screening options. The UST technology developed at LANL could be an alternative option to greatly improve the specificity and sensitivity of breast cancer screening without using ionizing radiation. LANL is developing high-resolution ultrasound tomography algorithms and a clinical ultrasound tomography scanner to conduct patient studies at the UNM Hospital. During UST scanning, the patient lies face-down while her breast, immersed in a tank of warm water, is scanned by phased-transducer arrays. UST uses recorded ultrasound signals to reconstruct a high-resolution three-dimensional image of the breast, showing the spatial distribution of mechanical properties within the breast. Breast cancers are detected by higher values of mechanical properties compared to surrounding tissues. Thus, high-resolution breast images obtained using LANL's novel UST algorithms have the potential to detect breast cancer at its earliest stage. The goal of this Multi-Team Award project is two-fold: (1) develop a novel, safe and cost-effective breast-imaging technique, and (2) improve the specificity and sensitivity of breast cancer imaging. The project is expected to integrate basic research with clinical studies, perform substantive cross-disciplinary training among scientists on the teams and involve participation of consumer advocates. Those involved in the project are optimistic about future developments.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Demonstration of <2 ns timing resolution for neutrino interaction in the MicroBooNE detector

The MicroBooNE detector, located in the Booster Neutrino Beamline (BNB) at Fermilab, collected data from 2015 to 2021. MicroBooNE’s Liquid Argon Time Projection Chamber is accompanied by a Photon Detection System consisting of 32 PMTs used to measure the argon scintillation light and determine the timing of the neutrino interactions. This work employs improved analysis techniques combining light signals and reconstructed tracks achieving neutrino interaction timing resolution <2 ns. The result obtained allows MicroBooNE to access the 2 ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved enables significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens the door for searching new long-lived-particles (e.g. Heavy Neutral Leptons, Higgs Portal Scalars) in MicroBooNE, as well in future large LArTPC experiments, namely SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology of the Extraction of Multi-Differential Cross Sections of Charged-Current $\nu_\mu$-Argon Interactions in MicroBooNE Using Wire-Cell $\nu_\mu$CC Selection

Neutrino physics experiments rely on accurate nuclear-interaction models that are in part guided by experimental observations. Multi-differential cross section measurements are particularly valuable for exploring the underlying physics described in these models, making them a significant step forward in the field. This note presents methodology in preparation to unfold neutrino flux-averaged double and triple-differential cross sections of the inclusive muon neutrino charged-current interaction on Argon. This work builds upon the existing framework and methodology presented in recent energy dependent cross section measurements at MicroBooNE using the Wire-Cell tomographic event reconstruction. The signal definition, choice of binning, and handling of estimated detector uncertainties are discussed, and the MicroBooNE simulation model is validated over the multi-dimensional phase space of muon momentum, muon polar angle, and visible hadronic energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

vdisdrops (b1)

A disdrometer measures the drop size distribution and velocity of falling hydrometeors. The 2-dimensional video-disdrometer (VDIS) comprises video cameras capable of observing individual hydrometeors from views perpendicular to each other. Two CCD line scan cameras are directed towards the measurement area. Objects passing through the measurement area—which is determined by the cross-section of the two optical paths as seen from above—obstruct the light and are detected as shadows by the cameras. Each camera contains a small embedded computer responsible for handling the data-capture process, analysis of the data, and their conversion and compression into a format suitable for further processing. Subsequently the data are transferred to the computer used for instrument control and final analysis. In order to identify individual precipitation particles by matching their views as seen by each of the cameras, it is necessary to synchronize the shutter and control both cameras with a synchronous line trigger signal. To reconstruct observables like falling velocity, oblateness, etc. from the datastreams of the two cameras, the two optical paths are displaced vertically by about 6mm, typically. Measuring this distance and adjusting the background illumination are the two major calibration and maintenance tasks necessary for successful operation of the device.

54 ENVIRONMENTAL SCIENCES↗

Third order digital-to-analog converter

System, consisting of sample and hold digital-to-analog converter, clock circuit, sample delay circuit, initial condition circuit and interpolator circuit, improves accuracy of reconstructed analog signal without increasing sample rates.

Dotson, W. P.↗

Observations of Martian surface winds at the Viking Lander 1 site

Martian surface winds at the Viking Lander 1 have been reconstructed using signals from partially failed wind instrumentation. Winds during early summer were controlled by regional topography, and then underwent a transition to a regime controlled by the Hadley circulation. Diurnal wind oscillations were controlled primarily by regional topography and boundary layer forcing, although a global mode may have been influencing them during two brief episodes. Semidiurnal wind oscillations were controlled by the westward-propagating semidiurnal tide from sol 210 onward. Comparison of the synoptic variations at the two sites suggests that the same eastward propagating wave trains were present at both sites.

Murphy, James R.↗

Atmospheric Correction of Satellite Imagery Using Modtran 3.5 Code

When performing satellite remote sensing of the earth in the solar spectrum, atmospheric scattering and absorption effects provide the sensors corrupted information about the target's radiance characteristics. We are faced with the problem of reconstructing the signal that was reflected from the target, from the data sensed by the remote sensing instrument. This article presents a method for simulating radiance characteristic curves of satellite images using a MODTRAN 3.5 band model (BM) code to solve the radiative transfer equation (RTE), and proposes a method for the implementation of an adaptive system for automated atmospheric corrections. The simulation procedure is carried out as follows: (1) for each satellite digital image a radiance characteristic curve is obtained by performing a digital number (DN) to radiance conversion, (2) using MODTRAN 3.5 a simulation of the images characteristic curves is generated, (3) the output of the code is processed to generate radiance characteristic curves for the simulated cases. The simulation algorithm was used to simulate Landsat Thematic Mapper (TM) images for two types of locations: the ocean surface, and a forest surface. The simulation procedure was validated by computing the error between the empirical and simulated radiance curves. While results in the visible region of the spectrum where not very accurate, those for the infrared region of the spectrum were encouraging. This information can be used for correction of the atmospheric effects. For the simulation over ocean, the lowest error produced in this region was of the order of 105 and up to 14 times smaller than errors in the visible region. For the same spectral region on the forest case, the lowest error produced was of the order of 10-4, and up to 41 times smaller than errors in the visible region,

Gonzales, Fabian O.↗

Wavelength Division Multiplexing Scheme for Radio-Frequency Single Electron Transistors

We describe work on a wavelength division multiplexing scheme for radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. Using discrete components, we made a two-channel demonstration of this concept and successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗

Multiplexing of Radio-Frequency Single Electron Transistors

We present results on wavelength division multiplexing of radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. A two-channel demonstration of this concept using discrete components successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗