Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Analytical comparison of transient and steady state visual evoked cortical potentials

To better describe the linear-dynamic properties of the human visual-cortical response system, transient and steady state Visual Evoked Response Potentials (VERP) were observed. The stimulus presentation device provided both the evoking stimulus (flickering or pulsing lights) and a video task display. The steady state stimulus was modulated by a complex, ten frequency, sum-of-sines, wave. The transient VERP was the time-locked average of the EEG to a series of narrow light pulses (pulse width of 10 msec). The Fourier transform of the averaged pulses had properties that approximate band limited white noise, i.e., a flat spectrum over the frequency region spanned by the 10 summed sines. The Fourier transform of both the steady state and the transient evoked potentials resulted in transfer that are equivalent and therefore comparable. To investigate the effects of task loading on evoked potentials, a grammatical reasoning task was provided. Results support the relevancy of continued application of a systems engineering approach for describing neurosensory functioning.

Junker, A. M.↗

Cloud streets during KonTur - A comparison of parallel/thermal instability modes with observations

Estimates of cloud street geometry produced by a model of the parallel/thermal instability modes of shallow convection are compared with observations obtained during the 1981 KonTur experiment. Good agreement between the modeled and observed orientation angles, wavelengths and Reynolds numbers are found when the streets are assumed to derive their energy from the average shear and the lowest order sine terms of a Fourier expansion of the mean wind profile (or equivalently from the lowest order cosine terms of the mean shear profile). The modes associated with the cosine terms of the wind profile (or the sine terms of the wind shear profile) do not agree well with the observations. These results suggest that the boundary layer rolls observed during KonTur might have developed owing to a combined parallel/thermal instability originating primarily from the cosine terms of the ambient roll parallel wind shear.

Shirer, H. N.↗

Geosat crossover analysis in the tropical Pacific. Part 1: Constrained sinusoidal crossover adjustment

A new method (constrained sinusoidal crossover adjustment) for removing the orbit error in satellite altimetry is tested (using crossovers accumulated in the first 91 days of the Geosat non-repeat era in the tropical Pacific) and found to have excellent qualities. Two features distinguish the new method from the conventional bias-and-tilt crossover adjustment. First, a sine wave (with wavelength equaling the circumference of the Earth) is used to represent the orbit error for each satellite revolution, instead of the bias-and-tilt (and curvature, if necessary) approach for each segment of the satellite ground track. Secondly, the indeterminacy of the adjustment process is removed by a simple constraint minimizing the amplitudes of the sine waves, rather than by fixing selected tracks. Overall the new method is more accurate, more efficient, and much less cumbersome than the old. The idea of restricting the crossover adjustment to crossovers between tracks that are less than certain days apart in order to preserve the large-scale long-term oceanic variability is also tested with inconclusive results because the orbit error was unusually nonstationary in the initial 91 days of the GEOSAT mission.

Tai, Chang-Kou↗

Sinusoidal transform coding

It has been shown that an analysis/synthesis system based on a sinusoidal representation of speech leads to synthetic speech that is essentially perceptually indistinguishable from the original. Strategies for coding the amplitudes, frequencies and phases of the sine waves have been developed that have led to a multirate coder operating at rates from 2400 to 9600 bps. The encoded speech is highly intelligible at all rates with a uniformly improving quality as the data rate is increased. A real-time fixed-point implementation has been developed using two ADSP2100 DSP chips. The methods used for coding and quantizing the sine-wave parameters for operation at the various frame rates are described.

Mcaulay, Robert J.↗

Re-examination of radiofrequency mass spectrometers: Center Director's Discretionary Fund

The three-stage, two-cycle, Bennett mass spectrometers in use in space and ground experiments today are of the same physical configuration as developed by Bennett in 1950. Sine-wave radiofrequency (RF) is also still used. The literature indicates that the electronics and physical manufacturing capabilities of 1950 technology may have limited the use of other improvements at that time. Therefore, a study, experimental and analytical, was undertaken to examine previously rejected RF approaches as well as new ones. The results of this study indicate there are other approaches which use fewer grids and square wave or a combination of square-wave and sine-wave RF. In regard to suppression of harmonics, none performed better than the three-stage, two-cycle, Bennett mass spectrometer. Use of square-wave RF in the Bennett approach can provide a slightly more compact configuration but no increase in throughput.

Carruth, M. R., Jr.↗

Geosat crossover analysis in the tropical Pacific. I - Constrained sinusoidal crossover adjustment

A new method (constrained sinusoidal crossover adjustment) for removing the orbit error in satellite altimetry is tested (using crossovers accumulated in the first 91 days of the Geosat non-repeat era in the tropical Pacific) and found to have excellent qualities. Two features distinguish the new method from the conventional bias-and-tilt crossover adjustment. First, a sine wave (with wavelength equaling the circumference of the Earth) is used to represent the orbit error for each satellite revolution, instead of the bias-and-tilt (and curvature, if necessary) approach for each segment of the satellite ground track. Secondly, the indeterminacy of the adjustment process is removed by a simple constraint minimizing the amplitudes of the sine waves, rather than by fixing selected tracks. Overall the new method is more accurate, more efficient, and much less cumbersome than the old. The idea of restricting the crossover adjustment to crossovers between tracks that are less than certain days apart in order to preserve the large-scale long-term oceanic variability is also tested with inconclusive results because the orbit error was unusually nonstationary in the initial 91 days of the GEOSAT mission.

Tai, Chang-Kou↗

Apparatus for using a time interval counter to measure frequency stability

An apparatus for measuring the relative stability of two signals is disclosed comprising a means for mixing the two signals down to a beat note sine wave and for producing a beat note square wave whose upcrossings are the same as the sine wave. A source of reference frequency is supplied to a clock divider and interval counter to synchronize them and to generate a picket fence for providing a time reference grid of period shorter than the beat period. An interval counter is employed to make a preliminary measurement between successive upcrossings of the beat note square wave for providing an approximate time interval therebetween as a reference. The beat note square wave and the picket fence are then provided to the interval counter to provide an output consisting of the time difference between the upcrossing of each beat note square wave cycle and the next picket fence pulse such that the counter is ready for each upcrossing and dead time is avoided. A computer containing an algorithm for calculating the exact times of the beat note upcrossings then computes the upcrossing times.

Greenhall, Charles A.↗

Waveform-Generating Program

GENERATE (Digital Generation of Complex Waveforms) computer program is flexible and reliable software tool for advanced generation of waveforms. User employs standard arithmetic operator (+, -, x, /, and parentheses) to simulate any combination of eight commonly used basic waveforms at desired amplitude and frequency. Creates data file based on user's selections from menu. Provides necessary equations describing eight basic waveforms and enables user to combine them arithmetically. Basic waveforms offered as building blocks; sine, ramp, exponential, logarithmic, step, clipped sine, square, and sawtooth. Also contains routine for plotting output waveform data on terminal with Tektronics (or equivalent) emulator, providing visual confirmation of desirability of waveform. Developed by use of VMS FORTRAN on DEC VAX 3600 computer.

Hopson, Charles B.↗

Loop current eddy shedding estimated using Geosat altimeter data

A method for extracting periodic signals from altimeter data is applied in the Gulf of Mexico using data from the first two years of the Geosat Exact Repeat Mission. The least squares fitting of selected frequencies of sine and cosine functions to the time series of sea surface height at each point of the Geosat ground track is used to estimate the dominant frequency in the gulf for this time period. Optimal interpolation of the sine and cosine coefficients at the dominant frequency to a uniformly spaced grid allows reconstruction of the time series in the gulf and shows eddies shedding from the Loop Current with a period of approximately 10.5 months, consistent with shedding periods determined from numerical models and analysis of satellite infrared data. This technique is a novel method for investigation of periodic signals in Geosat altimetry and is not severely affected by the data outages present in the time series.

Jacobs, Gregg A.↗

Method and apparatus for frequency spectrum analysis

A method for frequency spectrum analysis of an unknown signal in real-time is discussed. The method is based upon integration of 1-bit samples of signal voltage amplitude corresponding to sine or cosine phases of a controlled center frequency clock which is changed after each integration interval to sweep the frequency range of interest in steps. Integration of samples during each interval is carried out over a number of cycles of the center frequency clock spanning a number of cycles of an input signal to be analyzed. The invention may be used to detect the frequency of at least two signals simultaneously. By using a reference signal of known frequency and voltage amplitude (added to the two signals for parallel processing in the same way, but in a different channel with a sampling at the known frequency and phases of the reference signal), the absolute voltage amplitude of the other two signals may be determined by squaring the sine and cosine integrals of each channel and summing the squares to obtain relative power measurements in all three channels and, from the known voltage amplitude of the reference signal, obtaining an absolute voltage measurement for the other two signals by multiplying the known voltage of the reference signal with the ratio of the relative power of each of the other two signals to the relative power of the reference signal.

Cole, Steven W.↗

Vibration testing of large structures (CLAES Instrument)

The vibration testing performed on the Cryogenic Limb Array Etalon Spectrometer (CLAES) Instrument, installed on the Upper Atmosphere Research Satellite, is discussed. The tests discussed include random vibration, model verification using random vibration, and structural verification using a low frequency sine burst. Particular attention is given to the use of the sine burst test method to verify the structural integrity. Lessons learned from the program are summarized.

Newkirk, Roger↗

Importance of Geosat orbit and tidal errors in the estimation of large-scale Indian Ocean variations

To improve the estimate accuracy of large-scale meridional sea-level variations, Geosat ERM data on the Indian Ocean for a 26-month period were processed using two different techniques of orbit error reduction. The first technique removes an along-track polynomial of degree 1 over about 5000 km and the second technique removes an along-track once-per-revolution sine wave about 40,000 km. Results obtained show that the polynomial technique produces stronger attenuation of both the tidal error and the large-scale oceanic signal. After filtering, the residual difference between the two methods represents 44 percent of the total variance and 23 percent of the annual variance. The sine-wave method yields a larger estimate of annual and interannual meridional variations.

Perigaud, Claire↗

Force limited vibration testing of Cassini spacecraft cosmic dust analyser

The testing of the cosmic dust analyzer for the Cassini mission using the force limited method in order to avoid overtesting and to verify the ability of the specimen design to withstand the loads during launch and cruise, is reported on. In order to implement the method, force gages, fixtures and a test controller are required and the test specimen is subjected to sine vibration, random vibration and half sine shock. The practical aspects of the use of the force limited method are described. Due to the high loads and the weak design of the structural element, a notching method is used which provides the possibility of limiting the excitation to flight expected levels.

Jahn, Heiko↗

Liquid Motion Experiment Flight Test Results

The Liquid Motion Experiment (LME), designed to study the effects of liquid motion in rotating tanks, was flown on STS 84. LME was essentially a spin table that created a realistic nutation motion of scale-model tanks containing liquid. TWo spherical and two cylindrical transparent tanks were tested simultaneously, and three sets of such tanks were employed to vary liquid viscosity, fill level, and propellant management device (PMD) design. All the tanks were approximately 4.5 inches diameter. The primary test measurements were the radial and tangential torques exerted on the tanks by the liquid. Resonant frequencies and damping of the liquid oscillations were determined by sine sweep tests. For a given tank shape, the resonant frequency depended on fill level. For the cylindrical tanks, the resonances had somewhat different frequencies for the tangential axis (0.55 to 0.75 times spin rate) and the radial axis (0.73 to 0.78 times spin rate), and the tangential axis resonance agreed more closely with available analytical models. For the spherical tanks, the resonant frequencies were between 0.74 to 0.77 times the spin rate and were the same for the tangential and radial axes. The damping coefficients varied from about I% to 3% of critical, depending on tank shape, fill level, and liquid viscosity. 'Me viscous energy dissipation rates of the liquid oscillations were determined from sine dwell tests. The LME energy dissipation rates varied from 0.3 to 0.5 times the estimates obtained from scaling previous ground tests and spacecraft flight data. The PNDs sometimes enhanced the resonances and energy dissipation rates and sometimes decreased them, which points out the need to understand better the effects of PMD on liquid motion as a function of PMD and tank design.

Chato David J.↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: AMSU-A1 EOS Instrument, (S/N 202) Qualification Level Vibration Tests of August/September 1998, (S/O 565632, OC-417) Plus Addendum A

The purpose of this report is to present a qualification level vibration testing performed on the S/N 202, EOS AMSU-A1 Instrument was vibration tested to qualification levels per the Ref. 1 shop order. The instrument withstood the 8 g sine sweep test, the 7.5 Grms random vibration test, and the 18.75 g sine burst test in each of the three orthogonal axes. Some loss of transmissibility, however, is seen in the lower reflector after Z-axis random vibration. The test sequence was not without incidence. Failure of Channel 7 in the Limited Performance Test (LPT) performed after completion of the 1 st (X-axis) axis vibration sequence, required replacement of the DRO and subsequent re-testing of the instrument. The post-vibration comprehensive performance test (CPT) was successfully run after completion of the three axes of vibration with the replacement component installed in the instrument. Passing the CPT signified the successful completion of the S/N 202 A1 qualification vibration testing.

Heffer, R.↗

Comparison of Thermal Coefficients for Two Microwave Detectors

Laboratory measurements were performed to compare the thermal coefficients of two microwave detectors that might be used for direct detection in L-band radiometers. In particular it was desired to compare the performance of a new-technology flash ADC (analog-to-digital converter) against that of an older-technology diode detector in series with a VFC (voltage-to-frequency converter). The outputs of two state-of-the-art detectors were recorded as a constant 1.414-GHz signal was input and the physical temperatures of the detectors were varied over a range of 10 C. As a further experiment, each detector was tested with a noise diode source and with a sine wave synthesizer source. Thermal coefficients were computed in terms of W/C and in terms of ppt/C at nominal operating temperatures reasonable for the individual devices. Finally, thermal coefficients were calculated in K/C to indicate the change in brightness temperature seen by a theoretical sea surface salinity radiometer employing each detector. The K/C for the flash ADC was determined to be about 2.8 times that of the diode/VFC. Different reactions of the ADC to a noise input and a sine wave input indicated that ADC tests for radiometric purposes, such as this one, should be performed using a noise input.

Mackenzie, Anne I.↗

Status on Mechanical Testing at NASA GSFC

This viewgraph presentation provides an overview of current mechanical testing performed on spacecraft materials and instruments at NASA Goddard Space Flight Center. Specific mechanical testing procedures discussed include: force measurements limiting for sine, random vibration and acoustic tests, base driven model surveys, hydraulic shakers, new sine burst method and non contact sensors.

Kaufman, Daniel↗

1st- and 2nd-order motion and texture resolution in central and peripheral vision

STIMULI. The 1st-order stimuli are moving sine gratings. The 2nd-order stimuli are fields of static visual texture, whose contrasts are modulated by moving sine gratings. Neither the spatial slant (orientation) nor the direction of motion of these 2nd-order (microbalanced) stimuli can be detected by a Fourier analysis; they are invisible to Reichardt and motion-energy detectors. METHOD. For these dynamic stimuli, when presented both centrally and in an annular window extending from 8 to 10 deg in eccentricity, we measured the highest spatial frequency for which discrimination between +/- 45 deg texture slants and discrimination between opposite directions of motion were each possible. RESULTS. For sufficiently low spatial frequencies, slant and direction can be discriminated in both central and peripheral vision, for both 1st- and for 2nd-order stimuli. For both 1st- and 2nd-order stimuli, at both retinal locations, slant discrimination is possible at higher spatial frequencies than direction discrimination. For both 1st- and 2nd-order stimuli, motion resolution decreases 2-3 times more rapidly with eccentricity than does texture resolution. CONCLUSIONS. (1) 1st- and 2nd-order motion scale similarly with eccentricity. (2) 1st- and 2nd-order texture scale similarly with eccentricity. (3) The central/peripheral resolution fall-off is 2-3 times greater for motion than for texture.