Search NASA⌕ Search

SEARCH · Search NASA

Results for “Smoke Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Relationships between coronary heart disease risk factors and serum ionized calcium in Kennedy Space Center Cohort

Kennedy Space Center (KSC) employees are reported to be at high risk for coronary heart disease (CHD). Risk factors for CHD include high serum total cholesterol levels, low levels of high-density lipoprotein cholesterol (HDLC), elevated triglyceride, smoking, inactivity, high blood pressure, being male, and being older. Higher dietary and/or serum calcium Ca(++) may be related to a lower risk for CHD. Fifty men and 37 women participated. Subjects were tested in the morning after fasting 12 hours. Information relative to smoking and exercise habits was obtained; seated blood pressures were measured; and blood drawn. KCS men had higher risk values than KCS women as related to HDLC, triglycerides, systolic blood pressure, and diastolic blood pressure. Smoking and nonsmoking groups did not differ for other risk factors or for serum Ca(++) levels. Exercise and sedentary groups differed in total cholesterol and triglyceride levels. Serum Ca(++) levels were related to age, increasing with age in the sedentary group and decreasing in the exercisers, equally for men and women. It is concluded that these relationships may be significant to the risk of CHD and/or the risk of bone demineralization in an aging population.

Goodwin, Lisa Ann↗

80% Hydrogen Peroxide Mixtures with Various Fuels

Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1cm increments, though 1cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Due to the reactive nature of the peroxide in these mixtures, contact between the sample and sandpaper was minimized (<10s) prior to impact. Positive results were detected visually or audibly by the operator as smoke, flash, report, tearing of the sandpaper, etc. The test was conducted using the Bruceton technique to calculate the height at which there is a 50% chance of initiation (H 50 ).

36 MATERIALS SCIENCE↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Low hygroscopicity of ambient fresh carbonaceous aerosols from pyrotechnics smoke

Pyrotechnics (fireworks) displays are common for many cultures worldwide, with Independence Day celebrations occurring annually on July 4th as the most notable in the U.S. Given an episodic nature, fireworks aerosol properties are poorly characterized. Here we report observations of optical properties of fresh smoke emissions from Independence Day fireworks smoke sampled at Los Alamos National Laboratory, New Mexico U.S.A. on 4–5 July 2016. Aerosol optical properties were measured with a photoacoustic extinctiometer (PAX, DMT, Inc., Model 870 nm) at low RH < 30% and a humidity controlled nephelometry system (Ecotech, Inc., 450 nm Aurora). ‘Dry’ light scattering coefficient (σsp) increased from background < 15 Mm –1 reaching 120 Mm –1 (450 nm) as a 2-min event peak, while the absorption coefficient increased from background of 0.5–4.4 Mm –1 (870 nm). The event peak occurred at 00:35 on 5 July 2016, ~3 h after local fireworks events, and decreased to background by 04:00 on 5 July 2016, showing well mixed aerosol properties. A notable result is that the aerosol hygroscopic response, as characterized by the ratio of wet to dry light scattering or f (RH = 85%), declined to 1.02 at the peak fireworks influence from a background ~1.7. Strong wavelength dependence of light scattering with Ångström exponent ~2.2 throughout the event showed a size distribution dominated by sub-micrometer particles. Likewise, single scattering albedo at 870 nm remained constant throughout the event with ω = 0.86 ± 0.03, indicating light absorbing carbon, though not dominant, was mixed with organic carbon. Subsequent laboratory testing with ground-level sparklers showed that pyrotechnics smoke can generate a strong hygroscopic response, however. As confirmed with chemical analysis, the chemistry of the fireworks was key to defining the hygroscopic response. As a result, sparkler smoke was dominated by salt species such as hygroscopic potassium chloride while it lacked the black powder explosives in aerial fireworks that contribute organic and elemental carbon to its non-hygroscopic smoke.

54 ENVIRONMENTAL SCIENCES↗

Smoke detection

Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.

47 OTHER INSTRUMENTATION↗

Smoke detection

Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.

47 OTHER INSTRUMENTATION↗

Smoke detection

Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.

47 OTHER INSTRUMENTATION↗

Assessment of relative flammability and thermochemical properties of some thermoplastic materials

The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermal mechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in an anaerobic and oxidative environment, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers which were evaluated included: acrylonitrile-butadiene-styrene, bisphenol A polycarbonate, bisphenol fluorenone carbonatedimethylsiloxane block polymer, phenolphthalein-bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters including molding characteristics of some of the advanced polymers are described. Test results and relative rankings of some of the flammability, smoke and toxicity properties are presented.

Kourtides, D. A.↗

Thermoplastic polymers for improved fire safety

The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermomechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in anaerobic and oxidative environments, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers that were evaluated included: acrylonitrile butadiene styrene, bisphenol A polycarbonate, 9,9 bis (4-hydroxyphenyl) fluorene polycarbonatepoly (dimethyl siloxane) block polymer, phenolphthalein bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters, including molding characteristics of some of the advanced polymers, are described. Test results and relative ranking of some of the flammability, smoke, and toxicity properties are presented.

Kourtides, D. A.↗

The effects of forced air flow and oxygen concentration on flammability, smoke density, and pyrolytic toxicity

The question is posed whether forced air flow should be incorporated into flammability tests as a relevant variable. A test apparatus is described which permits tests to be conducted on small test specimens in a forced flow which is (continuously) variable over flow velocities from zero to 300 feet per minute (1.52 m/s). The effects of air-flow rate and oxygen concentration on flame propagation rate, maximum smoke density, and pyrolytic product toxicity were measured for a single material and were statistically evaluated. Regression analysis was used to graph the resulting relationships. It is concluded that air velocity is an important variable for laboratory flammability testing.

Sauers, D. G.↗

Performance and emission characteristics of swirl-can combustors to near-stoichiometric fuel-air ratio

Emissions and performance characteristics were determined for two full annular swirl-can combustors operated to near stoichiometric fuel-air ratio. Test condition variations were as follows: combustor inlet-air temperatures, 589, 756, 839, and 894 K; reference velocities, 24 to 37 meters per second; inlet pressure, 62 newtons per square centimeter; and fuel-air ratios, 0.015 to 0.065. The combustor average exit temperature and combustor efficiency were calculated from the combustor exhaust gas composition. For fuel-air ratios greater than 0.04, the combustion efficiency decreased with increasing fuel-air ratios in a near-linear manner. Increasing the combustor inlet air temperature tended to offset this decrease. Maximum oxides of nitrogen emission indices occurred at intermediate fuel-air ratios and were dependent on combustor design. Carbon monoxide levels were extremely high and were the primary cause of poor combustion efficiency at the higher fuel-air ratios. Unburned hydrocarbons were low for all test conditions. For high fuel-air ratios SAE smoke numbers greater than 25 were produced, except at the highest inlet-air temperatures.

Diehl, L. A.↗

Study to develop improved fire resistant aircraft passenger seat materials, phase 1

The procurement and testing of a wide range of candidate materials is reported. Improved fire resistant nonmetallic materials were subjected to tests to evaluate their thermal characteristics, such as burn, smoke generation, heat release rate and toxicity. In addition, candidate materials were evaluated for mechanical, physical and aesthetic properties. Other properties considered included safety, comfort, durability and maintainability. The fiscal year 1977 and the projected 1980 cost data were obtained for aircraft seat materials.

Trabold, E. L.↗

Evaluation of advanced combustion concepts for dry NO sub x suppression with coal-derived, gaseous fuels

The emissions performance of a rich lean combustor (developed for liquid fuels) was determined for combustion of simulated coal gases ranging in heating value from 167 to 244 Btu/scf (7.0 to 10.3 MJ/NCM). The 244 Btu/scf gas is typical of the product gas from an oxygen blown gasifier, while the 167 Btu/scf gas is similar to that from an air blown gasifier. NOx performance of the rich lean combustor did not meet program goals with the 244 Btu/scf gas because of high thermal NOx, similar to levels expected from conventional lean burning combustors. The NOx emissions are attributed to inadequate fuel air mixing in the rich stage resulting from the design of the large central fuel nozzle delivering 71% of the total gas flow. NOx yield from ammonia injected into the fuel gas decreased rapidly with increasing ammonia level, and is projected to be less than 10% at NH3 levels of 0.5% or higher. NOx generation from NH3 is significant at ammonia concentrations significantly less than 0.5%. These levels may occur depending on fuel gas cleanup system design. CO emissions, combustion efficiency, smoke and other operational performance parameters were satisfactory. A test was completed with a catalytic combustor concept with petroleum distillate fuel. Reactor stage NOx emissions were low (1.4g NOx/kg fuel). CO emissions and combustion efficiency were satisfactory. Airflow split instabilities occurred which eventually led to test termination.

Beebe, K. W.↗

Development of lightweight fire retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.

Arnold, D. B.↗

The Combined Effect of Cigarette Smoking and Fitness on Injury Risk in Men and Women

Abstract Background Prior studies have identified cigarette smoking and low fitness as independent risk factors for injury; however, no studies have evaluated the combined effect of cigarette smoking and fitness on injury risk. Objective To evaluate the combined effect of cigarette smoking and fitness on injury risk in men and women. Design This is a secondary analysis of data collected from US Army recruits (n = 2000) during basic combat training within the United States in 2007. Physical training and fitness, cigarette smoking, and prior injury data were obtained from questionnaires, whereas demographic and injury data were obtained from medical and basic combat training unit records. Chi-squared tests were used to assess differences in injury risk by fitness level and cigarette smoking. Relative risk values were calculated with 95% confidence intervals. Results The primary findings showed that smokers experienced 20%–30% higher risk of injury than nonsmokers. In addition, higher aerobic and muscular fitness was generally not protective against injury between least fit and more fit smokers. However, higher fitness was protective against injury between least and more fit nonsmokers, with least fit nonsmokers being 30%–50% more likely to experience an injury than fit nonsmokers. Conclusion This study revealed that higher aerobic and muscular fitness was not protective against injury among smokers; however, it was protective against injury among nonsmokers. Further implementation of smoking cessation programs may be beneficial for military and civilian personnel who are required to be physically fit in order to carry out their job responsibilities. Implications Male and female smokers experienced significantly higher risk of injury than nonsmokers. Although higher fitness is protective against injury in nonsmokers, the protective effect of fitness is lost among smokers. In an attempt to reduce injury risk among military and emergency personnel, smoking cessation programs should be further implemented among both more fit and less fit smokers.

Brooks, Raina D.↗

Development of a Low-Cost Particulate Matter Monitor

We describe a small, inexpensive portable monitor for airborne particulates, composed of the following elements: a. A simple size-selective inlet (vertical elutriator) that permits only particles below a pre-set diameter to pass and enter the measurement section; b. A measurement section in which passing particles are deposited thermophoretically on a micro-fabricated resonant piezoelectric mass sensor; c. An optical characterization module co-located with the mass sensor module that directs infrared and ultraviolet beams through the deposit. The emergent optical beams are detected by a photodiode. The optical absorption of the deposit can be measured in order to characterize the deposit, and determine how much is due to diesel exhaust and/or environmental tobacco smoke; and d. A small pump that moves air through the device, which may also be operated in a passive mode. The component modules were designed by the project team, and fabricated at UCB andLBNL. Testing and validation were performed in a room-sized environmental chamber at LBNL in to which was added either environmental tobacco smoke (ETS, produced by a cigarette smoking machine) or diesel exhaust (from a conventional diesel engine). Two pilot field tests in a dwelling compared the monitor with existing aerosol instruments during exposure to infiltrated ambient air to which cigarette smoke, diesel exhaust, wood smoke and cooking fumes were added. The limit of detection (LOD) derived from statistical analysis of field data is 18 mu g m-3, at the 99percent confidence level. The monitor weighs less than 120 g and has a volume of roughly 250 cm3. Power consumption is approximately 100 milliwatts. During this study, the optical component of the device was not fully implemented and has been left for future efforts. Suggested improvements in the current prototype include use of integrated thermal correction, reconfiguration of the resonator for increased particle collection area, increased thermophoretic collection efficiency using an increased temperature gradient, and shielding the resonator electronics from deposition of ultrafine particles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porting a fast-running wildfire plume model for use in national security and climate applications

In this project, the code for the fast-running Freitas wildfire plume model was successfully ported into the NARAC system, creating an operations-ready capability for predicting the transport of hazardous smoke from large wildfires. “Porting” refers to copying a section of code from one software package to another while accounting for unique dependencies in each software package. In this case, the code was ported from the Weather Research and Forecasting (WRF) Model, which is used extensively by the project team. To verify correct implementation, model results from the updated NARAC system were compared to those from WRF and the High-Resolution Rapid Refresh (HRRR) forecast model, which also employs the Freitas scheme. The NARAC User Interface (UI) and code documentation were also updated to include the new wildfire plume option, and a wildfire case was added to the NARAC test suite. The code was used in a real-time, semi-operational setup to predict smoke transport during the Cerro Pelado fire near Los Alamos National Laboratory in May 2022. The Freitas plume model was also tested for LLNL climate applications. Although the code was not ported into the Energy Exascale Earth System Model (E3SM), it was tested offline using E3SM atmospheric inputs, and results were compared to existing high-resolution plume predictions from large-eddy simulations in WRF. The code implementation and testing completed during this project will enable future work predicting smoke transport from large wildfires in LLNL national security and climate mission spaces.

54 ENVIRONMENTAL SCIENCES↗

Furniture wood wastes: Experimental property characterisation and burning tests

Referring to the industrial wood waste category (as dominant in the provincial district of Pesaro-Urbino, Marche Region, Italy), this paper deals with the experimental characterisation and the carrying out of non-controlled burning tests (at lab- and pilot-scale) for selected 'raw' and primarily 'engineered' ('composite') wood wastes. The property characterisation has primarily revealed the following aspects: potential influence on moisture content of local weather conditions at outdoor wood waste storage sites; generally, higher ash contents in 'engineered' wood wastes as compared with 'raw' wood wastes; and relatively high energy content values of 'engineered' wood wastes (ranging on the whole from 3675 to 5105 kcal kg{sup -1} for HHV, and from 3304 to 4634 kcal kg{sup -1} for LHV). The smoke qualitative analysis of non-controlled lab-scale burning tests has primarily revealed: the presence of specific organic compounds indicative of incomplete wood combustion; the presence exclusively in 'engineered' wood burning tests of pyrroles and amines, as well as the additional presence (as compared with 'raw' wood burning) of further phenolic and containing nitrogen compounds; and the potential environmental impact of incomplete industrial wood burning on the photochemical smog phenomenon. Finally, non-controlled pilot-scale burning tests have primarily given the following findings: emission presence of carbon monoxide indicative of incomplete wood combustion; higher nitrogen oxide emission values detected in 'engineered' wood burning tests as compared with 'raw' wood burning test; and considerable generation of the respirable PM{sub 1} fraction during incomplete industrial wood burning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗