Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Generating AC With Rotating Solar Cells

Rotating solar photovoltaic cells or batteries connected to suitable mechanical and/or electronic commutators produce nearly sinusoidal alternating current. Eliminates need for inverter circuitry and its attendant power-consumption and heat-dissipation problems, but imposes need for low-power-consumption rotary mechanism. Intended for use aboard spacecraft, also useful in special terrestrial situations where solar electric power must be transmitted over powerlines from one remote location to another.

Flanagan, David T.↗

Automated solar module assembly line

The solar module assembly machine which Kulicke and Soffa delivered under this contract is a cell tabbing and stringing machine, and capable of handling a variety of cells and assembling strings up to 4 feet long which then can be placed into a module array up to 2 feet by 4 feet in a series of parallel arrangement, and in a straight or interdigitated array format. The machine cycle is 5 seconds per solar cell. This machine is primarily adapted to 3 inch diameter round cells with two tabs between cells. Pulsed heat is used as the bond technique for solar cell interconnects. The solar module assembly machine unloads solar cells from a cassette, automatically orients them, applies flux and solders interconnect ribbons onto the cells. It then inverts the tabbed cells, connects them into cell strings, and delivers them into a module array format using a track mounted vacuum lance, from which they are taken to test and cleaning benches prior to final encapsulation into finished solar modules. Throughout the machine the solar cell is handled very carefully, and any contact with the collector side of the cell is avoided or minimized.

Bycer, M.↗

Africa Battery Energy Storage Systems (BESS) Capacity Building Li-Ion Battery Degradation and Performance [Slides]

This presentation is intended for power system engineers, operators, and planners who work on isolated power systems that have (or may soon have) high levels of power generation coming from wind turbines, solar farms, and battery energy storage, which are collectively referred to as inverter-based resources. It describes the basics of lithium-ion battery energy storage systems and lithium-ion battery degradation. Battery degradation at the cell-level is explained, and then the structure and degradation of battery energy storage systems is also explained. This is intended to help power system engineers, operators, and planners to understand and effectively utilize battery energy storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Experimental Setup and Learning-Based AI Model for Developing Accurate PV Inverter Models

The integration of power electronics-based interfaces presents challenges due to the absence of detailed models and the high computational complexity. Generic models used in system studies lack accuracy in capturing converter dynamics. This paper proposes a data-driven approach developed from experimental setup data. This approach enhances accuracy in photovoltaic inverter modeling. We used two types of PV inverters in the experiment. The recorded experimental data undergo processing through a machine learning model. Results from the model trained through machine learning is also presented.

artificial intelligence↗

Reducing Non-Radiative Recombination in Perovskite Solar Cells with a SiO2-Graphene Oxide Buried Interface Layer

Perovskite solar cells (PSCs) have emerged as a transformative photovoltaic technology. However, the device performance of inverted PSCs is dramatically limited by surface defects and the underlying film morphology of metal halide perovskite (MHP) thin film. Herein, we report a novel buried interface layer consisting of SiO2 nanoparticles (NPs) chemically bonded to graphene oxide (GO), deposited atop a hydrophobic hole extraction layer (HEL) to address this limitation. The SiO2 NPs serve as insoluble scaffolds that immobilize GO sheets on the hydrophobic HEL surface, enabling the formation of homogeneous MHP thin films. Meanwhile, the GO functional groups interact with surface-uncoordinated Pb2+, suppressing interfacial defects and guiding crystal grain growth of the resultant MHP thin films. This synergistic effect suppresses non-radiative charge recombination and enhances charge extraction efficiency. As a result, a 26.07% efficiency with significantly suppressed photocurrent hysteresis is observed from PSCs incorporating the SiO2-GO buried interface layer. Moreover, the above PSCs maintain 92% of their initial PCE after 1800 h of continuous operation at the maximum power point under AM 1.5 G (100 mW/cm2) illumination at 25 degrees C in air with 50-60% relative humidity. These results demonstrate that we have developed a facile and effective way to realize high-performance inverted PSCs.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current Regulator For Sodium-Vapor Lamps

Regulating circuit maintains nearly-constant alternating current in sodium-vapor lamp. Regulator part of dc-to-ac inverter circuit used to supply power to street lamp from battery charged by solar-cell array.

Mclyman, W. T.↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a three-phase electric power, 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

grid-forming inverter↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗