Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Plus Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Utility-Scale Solar: Empirical Trends in Project Technology, Cost, Performance, and PPA Pricing in the United States – 2018 Edition

The utility-scale solar sector has led the overall U.S. solar market in terms of installed capacity since 2012. In 2017, the utility-scale sector accounted for nearly 60% of all new solar capacity, and is expected to maintain its market-leading position for at least another six years. Two-thirds of all states, representing all regions of the country, are now home to one or more utility-scale solar projects. This report—the sixth in an ongoing annual series—provides in-depth data-driven analysis of the utility-scale solar project fleet in the United States. Drawing on empirical project-level data from a wide range of sources, this report analyzes technology trends, installed project prices, operating costs, capacity factors, power purchase agreement ("PPA") prices, the levelized cost of solar energy (LCOE), and the market value of solar. Given its current preeminence in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are also presented where appropriate. Highlights from this year's edition include: -Installation and Technology Trends: The use of solar trackers dominated 2017 installations with nearly 80% of all new capacity. In a reflection of the ongoing geographic expansion of the market beyond California and the high-insolation Southwest, the median insolation level at newly built project sites declined again in 2017. While new fixed-tilt projects are now seen predominantly in less-sunny regions, tracking projects are increasingly pushing into these same regions. The median inverter loading ratio grew to 1.32 in 2017, allowing the inverters to operate closer to full capacity for a greater percentage of the day. -Installed Prices: Median installed PV project prices have steadily fallen by two-thirds since the 2007-2009 period, to $2.0/WAC (or $1.6/WDC) for projects completed in 2017. The lowest 20th percentile of projects within our 2017 sample were priced at or below $1.8/WAC, with the lowest-priced projects around $0.9/WAC. Overall price dispersion across the entire sample has decreased steadily every year since 2013; similarly, price variation across regions decreased in 2017. -Operation and Maintenance ("O&M") Costs: PV O&M costs were in the neighborhood of $16/kWAC-year, or $8/MWh, in 2017. These numbers include only those costs incurred to directly operate and maintain the generating plant. -Capacity Factors: The cumulative net AC capacity factors of individual projects vary widely, from 14.3% to 35.2%, with a sample median of 26.3%. This project-level variation is based on a number of factors, including the strength of the solar resource at the project site, whether the array is mounted at a fixed tilt or on a tracking mechanism, the inverter loading ratio, degradation, and curtailment. Changes in at least the first three of these factors drove mean capacity factors higher from 2010-vintage to 2013-vintage projects, where they've remained fairly steady among more-recent project vintages as an ongoing increase in the prevalence of tracking has been offset by a build-out of lower resource sites. -PPA Prices and LCOE: Driven by lower installed project prices and improving capacity factors, levelized PPA prices for utility-scale PV have fallen dramatically over time, by $20-$30/MWh per year on average from 2006 through 2012, with a smaller price decline of ~$10/MWh per year evident from 2013 through 2016. Most recent PPAs in our sample—including many outside of California and the Southwest—are priced at or below $40/MWh levelized (in real 2017 dollars), with a few priced as aggressively as ~$20/MWh. The median LCOE among operational PV projects in our sample has followed PPA prices lower, suggesting a relatively competitive market for PPAs. -Solar's Wholesale Energy Market Value: Falling PPA prices have been offset to some degree by a decline in the wholesale energy market value of solar within higher-penetration markets like California, where solar earned just 79% of the average price across all hours within CAISO's real-time wholesale energy market in 2017 (down from 125% back in 2012). In other markets with less solar penetration, however, solar's hourly generation profile still earns more than the average wholesale price (e.g., 127% in ERCOT, 112% in PJM). -Solar+Storage: Adding battery storage is one way to at least partially restore the value of solar, and three recent PV+storage PPAs in Nevada (each using 4-hour batteries sized at 25% of PV nameplate capacity) suggest that the incremental PPA price adder for storage has fallen to ~$5/MWh, down from ~$15/MWh just a year ago for a similarly configured project. As PV plus battery storage becomes more cost-effective, a number of developers are regularly offering it as a viable upgrade to standalone PV. At the end of 2017, there were at least 188.5 GW of utility-scale solar power capacity within the interconnection queues across the nation. The 2017 growth within these queues is widely distributed across all regions of the country, but is most pronounced in the up-and-coming Midwest region, which accounts for 27% of the 99.2 GW of new queue capacity. The widening geographic distribution is as clear of a sign as any that the utility-scale market is maturing and expanding outside of its traditional high-insolation comfort zones.

14 SOLAR ENERGY↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks, With Minimum Sustainable Price Analysis: Q1 2022

NREL's bottom-up cost models can be used to assess the minimum sustainable price (MSP) and modeled market price (MMP) of PV and storage systems having various configurations. MSP can be used to estimate future potential cost-reduction opportunities for PV and PV-plus-storage systems, thus helping guide research and development aimed at advancing cost-effective system configurations. MMP can be used to understand the cost of systems under recent market conditions. The MSP data in this annual benchmarking report will be used to inform the formulation of, and track progress toward, the Solar Energy Technologies Office's Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

Recent Progress in Cathode Materials for Sodium-Metal Halide Batteries

Transitioning from fossil-fuels to renewable energy sources is a critical goal of greenhouse gas re-duction and climate control. Major improvements have made wind and solar power increasingly cost-competitive with fossil fuels. However, the inherent intermittency of renewable power sources such motivates pairing these resources with energy storage. Electrochemical energy storage in batteries is widely used in many fields and increasingly for grid-level storage, but current battery technologies still fall short of performance, safety, and cost. This review focuses on sodium metal halide (Na-MH) batteries, such as well-known Na-NiCl2 batteries, as a promising solution to safe and economical grid-level energy storage. Important features of conventional Na-MH batteries are discussed, and recent literature on the development of intermediate temperature, low-cost cathodes for Na-MH batteries is highlighted. By employing lower cost metal halides (e.g. FeCl2, ZnCl2, and CuCl2, etc.) in the cathode and operating at lower temperatures (e.g. 190 °C vs. 280 °C), new Na-MH batteries have the potential to offer comparable performance at much lower overall costs, providing an exciting alternative technology to enable widespread adoption of renewables plus storage for the grid.

Zhan, Xiaowen↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2022 Edition [Slides]

Falling battery prices and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data mined from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes co-located hybrid plants that pair two or more generators and/or that pair generation with storage at a single point of interconnection, and full hybrids that feature co-location and co-control. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2021, there were nearly 300 hybrid plants (>1 MW) operating across the United States, totaling nearly 36 gigawatts (GW) of generating capacity and 3.2 GW/8.1 GWh of energy storage. PV+storage plants are by far the most common, dominating in terms of plant number (140), storage capacity (2.2 GW/7.0 GWh), storage:generator ratio (53%), and storage duration (3.2 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was a breakout year for PV+storage hybrids in particular: 67 of the 74 hybrids added in 2021 were PV+storage. By the end of 2021, there were more GW of battery capacity installed in PV+storage hybrids (2.2 GW) than as standalone storage plants (1.8 GW). The difference is even starker in energy terms, with PV+storage plants hosting twice as much battery capacity as standalone storage plants (7 GWh vs. 3.5 GWh, respectively). Much of the battery capacity added in hybrid form in 2021 was a battery retrofit to a pre-existing PV plant. -Data on plants under development from the interconnection queues of all seven ISOs/RTOs plus 35 individual utilities suggest that these hybridization trends are likely to continue. At the close of 2021, there were more than 670 GW of solar plants in the nation’s queues; 285 GW (~42%) of this capacity was proposed as a hybrid, most typically pairing PV with battery storage (PV+storage represented nearly 90% of all hybrid capacity in the queues). For wind, 247 GW of capacity sat in the queues, with 19 GW (~8%) proposed as a hybrid, again most-often pairing wind with storage (wind+storage represented ~4% of all hybrid capacity in the queues). Meanwhile, nearly half of all storage in the queues is estimated to be part of a hybrid plant. While many of these proposed plants will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants

The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

14 SOLAR ENERGY↗

Development of a Techno-Economic Analysis Framework for a Solar Thermochemical Fuel Production Process

Synthetic liquid fuels can provide a drop-in substitute for fossil-based fuels in sectors such as aviation and maritime, where electrification is not a viable option due to the need for high specific energy density. However, for these alternative fuels to be adopted at a commercial scale, their price must be competitive compared to their fossil-based counterparts. The reverse water-gas shift (RWGS) reaction offers a promising pathway, using hydrogen (sourced from electrolysis) and carbon dioxide as the feed and reacting to produce syngas - a mixture of H2 and CO at a specific ratio. Syngas is a useful precursor that can be converted into fuels and chemicals via known downstream processes, such as liquid transportation fuels via Fischer-Tropsch (FT) synthesis. The RWGS reaction is currently not applied in commercial scale, unlike the rest of the components in the process chain (electrolyzers and syngas-to-fuel synthesis units). The RWGS reaction poses several challenges due to its restrictive thermodynamics. Being an equimolar reaction, high temperatures and a large excess of H2 are needed to achieve reasonable CO2 conversion at equilibrium. This has detrimental effects on practical process implementation and the quality of syngas that can be produced, with direct effect on the energy and capital requirements, as well as the need for expensive downstream separation. In this work, we are proposing to develop a new concentrating solar thermal (CST) compatible RWGS reactor, performing the reaction in a 2-step chemical looping process using metal oxide at a temperature range of 600-800 degrees Celsius. By decoupling the reactor from the solar receiver, the Generation 3 (Gen3) CST technology could be utilized, together with its proposed thermal energy storage (TES) technology, benefitting from a good match to the required temperatures. CST technology is a viable option for supplying the heat that could be rapidly deployed in scale, thus being a good match to the gas-to-liquid (GTL) process which requires a large minimal scale to be commercially viable. The integration of TES with CST also allows operating the plant at large annual capacity factors and avoids multiple shutdown/startup cycles, thus fitting into the steady-state operation mode that most GTL processes require. The main innovation in the proposed design hinges on a countercurrent reaction design using a packed bed reactor. In 2019 Metcalfe et al. showed the benefits of countercurrent species exchange could be realized in a redox chemical-looping processes, by storing the favorable countercurrent chemical potential profiles in a packed bed of non-stoichiometric oxide. Metcalfe et al. applied this breakthrough concept to the WGS reaction, which is conventionally a co-feed catalytic process, showing a dramatic improvement. Bulfin et al. (2023) performed a similar proof-of-concept demonstration for the RWGS reaction using CeO2, achieving cumulative and peak CO2 conversions of 88% and 95%, respectively, compared to a thermodynamic limit of 58% for the co-feed catalytic process at the same conditions. In our new REGENLOOP project, we are developing a reactor prototype from the heat-exchange packed bed reactor-type, a commonly used reactor in the chemical industry. The endothermic heat of reduction will be supplied to the reactor using CST, while the same heat transfer fluid (HTF) mechanism will be used to extract the exothermic heat of oxidation. An array of multiple reactors is used to supply constant high-purity CO stream, that is then mixed with H2 from electrolysis to produce a high-purity syngas at the required composition. By removing the CO-CO2 separation after the RWGS process, significant energy and cost reduction can be achieved. A physics-based TEA framework is currently being developed, covering all the major plant processes, from the solar collection through storage, chemical looping RWGS, GTL, and auxiliary unit operations, up to the liquid hydrocarbon product. This modeling framework will utilize reduced-order models for the chemical looping RWGS and TES, CST modeling using SolarPILOT, and Aspen Plus for the GTL. By using this combined physics-based approach, the effects of design/operating parameters on the performance and cost can be elucidated. In our presentation, the modeling framework will be presented in detail, including preliminary cost predictions of using this plant configuration under a few selected relevant case studies. This study will be used to identify the major cost drivers, informing further system design and optimization needed to chart the way for a commercially viable pathway.

14 SOLAR ENERGY↗

Activating Opportunity Zones for Rapid Solar+Storage Deployment in Low Income Communities (Final Report)

Millions of Texans choose their own power provider, giving them the option to have low-cost and even renewable energy delivered through their retail electric plan. However, Texans with less disposable income often pay more for electricity and have limited access to green energy and emergency backup power even though the costs of solar and wind power are at record lows and continue to decline. The Powered for Good initiative aimed to help deliver clean, affordable, 100% renewable electricity to low-income households in Texas’s Competitive Retail Areas, where households can choose their electricity provider. Objectives: The primary goal of this project was to develop and validate one or more affordable solar+storage products (i.e., priced less than of $0.14/kWh) that Retail Electricity Providers (REP) can offer to LI households. The team achieved three objectives: 1. Investigate how to best reduce electricity costs and increase availability of emergency power for LI customers; 2. Build momentum for, and facilitate an approach to, a Texas-based pilot deployment of such solar+storage products, with a goal of greatly expanding this approach to a large segment of the LI population in Texas; 3. Provide the structural framework, finance model, and roadmap to potentially increase investment of solar+storage projects in LI communities across U.S. states when modified to meet their state-specific laws and regulations. The team evaluated the market of viable solutions for low-income Texans through interviews and focus groups with professionals and residents with lived experience. The team then piloted a low-cost retail electric product. Following the pilot, the team developed educational materials, including fact sheets, a Go Green Save Green interactive guide, and an Electricity Bill Analysis Tool. The team is now working to increase power resilience and reduce energy insecurity with micro solar and storage in partnership with local entities in the Harris County area. Key Findings: Informed by Powered for Good research, including the experiences on Texas residents and electricity system experts, the Powered for Good team developed a pilot that was implemented by Energy Well Texas, a new company formed in late 2020. The pilot featured a combination of a 100% clean residential energy offering delivered through the electrical grid plus a selection of batteries, lights and a solar panel that provided participants with varying levels of backup power. For the 8 customers who submitted previous bills, the Energy Well Texas pilot reduced energy bills by about 30%. In Houston, residents earning less than 30% of Area median Income (AMI) spend an average 13% of their income on energy or about $1,555 per year. Repeating the pilot results for these residents could yield $466 in savings per customer or about 4% of their income. While this will not end energy poverty, it is a big step toward that goal. The Powered for Good and Energy Well Texas teams are currently planning their post-pilot phase of service offerings.

14 SOLAR ENERGY↗

SolarAPP+ Enhancements and Commercialization (Final Technical Report)

With millions of distributed photovoltaic (PV) systems expected to be installed over the next five years, the permitting and inspection processes of authorities having jurisdiction (AHJs) may become overburdened, causing delays and increased costs for installed systems (Cruce et al. 2022). The central goal of this project was to automate and streamline permitting processes for distributed PV systems and complementary technologies, such as battery storage. Deploying automated permitting has been hypothesized to reduce permit review times, resulting in reduced costs and improved customer experience. This has the potential to expand the PV and PV-plus-storage market nationwide. The National Renewable Energy Laboratory (NREL) and its project partners, including UL Solutions, the Interstate Renewable Energy Council (IREC), the International Code Council (ICC), and more, developed the Solar Automated Permit Processing (SolarAPP+™) software platform to reduce permit review times. NREL and its partners also collaborated with the solar industry, the building safety community, and local governments to develop SolarAPP+.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating the Cost Benefits of U.S. Utility-Scale Photovoltaics Plus Energy Storage Systems

Utility-scale photovoltaics (PV) system market growth has been rapid for several years. Today, with the cost reductions of energy storage technologies, the application of combing PV and energy storage has become feasible and beneficial, especially for the areas that only have PV standalone systems and need to shift the peak load to meet the evening electricity demand. Overall, the utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a systemlevel bottom-up cost modeling approach. We use this model to benchmark PV plus storage installation system cost and identify cost difference for AC and DC coupled systems and duration variation. Finally, we assess the cost reduction opportunities of co-locating PV system with energy storage system in order to indicate the possible economic impacts of PV plus storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

2018 U.S. Utility-Scale Photovoltaics-Plus-Energy Storage System Costs Benchmark

Market growth for utility-scale photovoltaic (PV) systems has been rapid for several years. Today, with the cost reductions of energy storage technologies, the combining PV and energy storage has become feasible and beneficial, especially for the areas that have only PV standalone systems and need to shift the peak load to meet electricity demand in the evening. Overall, utility-scale PV plus energy storage systems can provide dispatchable energy and reliable capacity. This study details cost factors, including labor costs, material costs, overhead, and permitting costs using a system-level bottom-up cost modeling approach. We use this model to benchmark PV-plus-storage installation system cost and identify the cost difference for AC- and DC-coupled systems and duration variation. Finally, we assess the cost reduction opportunities of colocating PV systems with energy storage systems in order to indicate the possible economic impacts of the PV-plus-storage configuration and help future research and development (R&D) effects in the context of U.S. energy storage policymaking.

14 SOLAR ENERGY↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States, 2022 Edition

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The latest edition of the report focuses on systems installed through year-end 2021, and is based on data from roughly 2.5 million systems. New to the report this year is an expanded coverage of paired PV-plus-storage systems, including details on system design and pricing trends. The report describes trends related to: -Project characteristics, including system size, module efficiencies, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and non-residential customer segmentation ownership -Median installed-price trends, both nationally and by state, including preliminary data for first half of 2022 -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive and econometric analysis

14 SOLAR ENERGY↗

Identifying Barriers to Solar and Storage Hybrids: Modeled vs. empirical wholesale market value and net-value for co-located solar + storage projects [Slides]

Large-scale (1MW+) co-located solar and battery storage projects are expanding rapidly in the United States, but their realized contribution to the bulk power system remains poorly understood because public project-level operating data are limited. The Lawrence Berkeley National Laboratory estimates the wholesale market value of 280 operational photovoltaic-plus-storage (PV+S) projects across the seven ISOs/RTOs and 19 additional balancing authorities, representing roughly 95% of the U.S. PV+S fleet in 2024. We model optimized hourly dispatch under energy, capacity, and ancillary-service market opportunities and compare the resulting value with standalone PV value, project-specific levelized cost estimates, and empirical operating or revenue data where available.

14 SOLAR ENERGY↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Techno-Economic Assessment of Geothermal Power Plants Hybridized with Solar Heat and Thermal Storage

Geothermal power plants may experience a decrease in power output over time due to a reduction in either mass flow rate, temperature or pressure of the resource. A recent study quantified the temperature drawdown of U.S. double-flash geothermal power plants at 0.8% per year. Hybridizing existing geothermal plants with other renewable power sources to exploit the unused capacity of the geothermal power block has become an area of increasing interest. For instance, a geothermal power plant may be retrofitted with heat from a concentrating solar field. In addition, geothermal may be integrated with solar in a new-build site with the aim of combining the benefits of both technologies -- i.e. the baseload generation of geothermal, plus the relatively high efficiency of concentrating solar power. In this article, we give an overview of hybrid geothermal-solar projects undertaken at the National Renewable Energy Laboratory in collaboration with various partners. We investigate the retrofit of double-flash and binary geothermal plants with solar heat. Off-design models are developed and validated with operational data. Annual simulations evaluate the hourly performance, the benefits of thermal storage, and are used to calculate economic metrics. Finally, we discuss the implications of integrating solar and geothermal in a new greenfield site.

15 GEOTHERMAL ENERGY↗

Hybrid Systems to Enable High Penetration PV

A model for PV plus energy storage and fuel cells was developed in the System Advisor Model (SAM). This model was used to evaluate the ramp rate and interconnection capacity factor for a hypothetical utility-scale plant for several configuration options. For PV only, the plant experienced 3345 violations of a 10%/minute ramp up limitation and a interconnection capacity factor of 17.6%. Adding a battery reduced the violations to 154 per year and the magnitude of the average violation to 2%. Adding a fuel cell to the PV system increased the capacity factor to 78% without improving ramp violations. Using a combined PV plus storage plus fuel cell arrangement maintained the improved capacity factor while reducing ramp up violations to 23, illustrating the potential to operate a hybrid system both to enable grid integration requirements and increase utilization of the interconnection.

14 SOLAR ENERGY↗

Overhead Protection Increases Fuel Quality and Natural Drying of Leaf-On Woody Biomass Storage Piles

Short-rotation woody crops (SRWC) have the potential to make substantial contributions to the supply of biomass feedstock for the production of biofuels and bioproducts. This study evaluated changes in the fuel quality (moisture, ash, and heating value) of stored spring harvested shrub willow (Salix spp.) and hybrid poplar (Populus spp.) chips with respect to pile protection treatments, location within the storage piles, and length of storage. Leaf-on willow and poplar were harvested in the spring, and wood chips and foliage with moisture content in the range of 42.1% to 49.9% (w.b.) were stored in piles for five months, from May to October 2016. Three protection treatments were randomly assigned to the piles. The control treatment had no cover (NC), so piles were exposed to direct solar radiation and rainfall. The second treatment had a canopy (C) installed above the piles to limit direct rainfall. The final treatment had a canopy plus a dome aeration system (CD) installed over the piles. Covering piles reduced and maintained the low moisture content in wood chip piles. Within 30 days of establishment, the moisture content in the core of the C pile decreased to less than 30%, and was maintained between 24%–26% until the end of the storage period. Conversely, the moisture content in the NC piles decreased in the first two months, but then increased to the original moisture content in the core (>45 cm deep) and up to 70% of the original moisture content in the shell (<45 cm deep). For all the treatments in the tested conditions, the core material dried faster than the shell material. The higher heating value (HHV) across all the treatments increased slightly from 18.31 ± 0.06 MJ/kg at harvest to 18.76 ± 0.21 MJ/kg at the end of the storage period. The lower heating value (LHV) increased by about 50% in the C and CD piles by the end of the storage period. However, in the NC piles, the LHV decreased by 3% in the core and 52% in the shell. Leaf-on SRWC biomass stored in piles created in late spring under climatic conditions in central and northern New York showed differing moisture contents when stored for over 60–90 days. Overhead protection could be used to preserve or improve the fuel quality in terms of the moisture content and heating value if more than two months of storage are required. However, the implementation of such management practice will depend on whether the end users are willing to pay a higher price for dryer biomass and biomass with a higher LHV.

54 ENVIRONMENTAL SCIENCES↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗