Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗

AmeriFlux US-Wwt Willamette Wheat

This is the AmeriFlux version of the carbon flux data for the site US-Wwt Willamette Wheat. Site Description - The site was established in summer 2014 and is part of the Oregon eddy covariance flux tower network . Meteorological variables such as temperature, humidity, solar irradiance and wind are measured at this site. Turbulent fluxes of water vapor, carbon dioxide and heat are observed and stored as 30 minute averages. The crop changes periodically and rye grass and fescue is grown alternately at this site located in Oregon's Willamette Valley with its relatively mild climate. The Wheat site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Law, Bev↗

A Nonintrusive Optical Approach to Characterize Heliostats in Utility-Scale Power Tower Plants: Camera Position Sensitivity Analysis

Optics plays a major role in the effectiveness of concentrating solar power (CSP) technologies. The nonintrusive optical (NIO) approach developed by the National Renewable Energy Laboratory uses uncrewed aircraft system (UAS)-based imaging to survey heliostats in a commercial-scale power tower CSP plant and characterize their optical errors. The image processing algorithm uses photogrammetry to calculate the camera position for each image frame, and the accuracy of the estimated optical errors is highly sensitive to the calculated camera position accuracy. In this study, we simulate a series of case studies in python to examine the impact of different parameters of the sensitivity of the camera calculation, including the number of facet corners used as control points for the photogrammetric calculation, precision error in the detected pixel locations of the facet corners in the image, and precision error of the canting and mounting positions of the facets of the heliostat. The case studies consider heliostat geometry based on three commercial designs to serve as representative examples of different possible sizes of heliostats that the NIO method could be applied to. The results show that increasing the number of control points can improve accuracy for heliostats with many facets, pixel precision has a significantly larger impact on camera calculation accuracy than facet canting and mounting errors, and the camera distance and focal length must be chosen to ensure adequate pixel accuracy on the heliostat surface depending on the size of heliostat. In conclusion, based on the results, recommendations for the allowable values of each parameter are provided to achieve the required NIO optical error estimation accuracy depending on the size of heliostat.

14 SOLAR ENERGY↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Beamed Energy and Communications Optical Node (BEACON) Demonstrator

Due to long shadow periods (2 weeks or greater) on the south pole, concepts to raise solar arrays to a sufficient height at specific locations have shown the capability to provide power to surface users for much longer periods. Such a tower can also provide a 3rd Generation Partnership Project (3GPP) service for users up to 10 km away, dependent on terrain. An option to deliver power, albeit with low efficiency, using a laser beam coupled with the tower height could provide mobile and fixed users power during darkness, reducing their battery requirements. A demonstration of these technologies in the lunar environment is crucial to support future Artemis campaigns as well as potential emerging lunar infrastructures. A demonstrator design of a 15 m deployed boomon the south pole has been shown to enable both the gathering of kilowatts of power and the provision of 3GPP relay and backhaul given an appropriate lunar location. Using a laser to send power to a photovoltaic receiver has been proposed to transmit electrical power on the moon, particularly for applications such as powering a rover in near-polar permanently shadowed regions (PSR) where solar power is not available. In this work, the Compass team performed a conceptual engineering design study of a near-term laser surface-to-surface power beaming and relay station using a tower to simultaneously carry the power source (Vertical Solar Array Technologies (VSAT)[1]), the 3GPP relay antenna, and the laser telescope.

Deployable solar array tower laser beamed power 3G↗

Beamed Energy and Communications Optical Node (BEACON) Demonstrator

Due to long shadow periods (2 weeks or greater) on the south pole, concepts to raise solar arrays to a sufficient height at specific locations have shown the capability to provide power to surface users for much longer periods. Such a tower can also provide a 3rd Generation Partnership Project (3GPP) service for users up to 10 km away, dependent on terrain. An option to deliver power, albeit with low efficiency, using a laser beam coupled with the tower height could provide mobile and fixed users power during darkness, reducing their battery requirements. A demonstration of these technologies in the lunar environment is crucial to support future Artemis campaigns as well as potential emerging lunar infrastructures. A demonstrator design of a 15 m deployed boomon the south pole has been shown to enable both the gathering of kilowatts of power and the provision of 3GPP relay and backhaul given an appropriate lunar location. Using a laser to send power to a photovoltaic receiver has been proposed to transmit electrical power on the moon, particularly for applications such as powering a rover in near-polar permanently shadowed regions (PSR) where solar power is not available. In this work, the Compass team performed a conceptual engineering design study of a near-term laser surface-to-surface power beaming and relay station using a tower to simultaneously carry the power source (Vertical Solar Array Technologies (VSAT)[1]), the 3GPP relay antenna, and the laser telescope.

Lunar Relay↗

Wave propagation in the chromosphere and transition region

The results from a joint observing program involving the solar ultraviolet measurement of emitted radiation (SUMER), the coronal diagnostic spectrometer (CDS) and the extreme-ultraviolet imaging telescope (EIT) onboard the Solar and Heliospheric Observatory (SOHO) are presented. These operations were coordinated with ground-based observations at the vacuum tower telescope at Izana (Tenerife). The purpose was to characterize the wave propagation properties in the solar atmosphere, from the photosphere through the chromosphere into the transition region.

Steffens, S.↗

FY2023 NSTTF Annual Report

The National Solar Thermal Test Facility (NSTTF) is a DOE Core Capability and Technology Deployment Center located in Albuquerque, NM. It is operated by Sandia National Laboratories (Sandia) for the U.S. Department of Energy (DOE). The NSTTF is the only multi-mission, multi-use, multi-story test facility of its type in the United States. The NSTTF was founded in 1978 and began testing with high heat flux that same year. Over the past 45 years, the NSTTF has been at the forefront of the research, design, fabrication, and testing of many of the critical Concentrating Solar Power (CSP) technologies. These technologies have allowed costs to be dramatically reduced from over $\$ $0.40 /kWh to $\$$0.12 /kWh since the conception of this renewable energy technology. The NSTTF has worked to make the Solar Energy Generating Systems (SEGS) parabolic trough plants successful, while also working with the Solar One and Solar Two facilities for successful implementation. Over the four decades since its founding, the mission of the NSTTF has grown to include new receiver technologies, like our generation 3 falling particle system (G3P3 Tower), optical metrology techniques like SOFAST, molten salt testing, thermal energy storage, solar thermal chemistry, and more. We continue to expand our capabilities in pursuit of the DOE SETO mission and the DOE SunShot 2030 goals: unsubsidized LCOE of $\$$0.05/kWh for CSP that includes 12 or more hours of thermal energy storage. To support both the DOE SETO mission and support the CSP sector as a whole, we are working to develop our operations and maintenance framework to provide a world class testing facility in support of our technological achievements. To accomplish both of these missions, the NSTTF draws on the decades of experience and expertise of our staff along with the world-class facilities at Sandia National Laboratories to further the science of concentrated solar thermal technologies in diverse applications. We remain a trusted partner for high-quality and impactful research in both fundamental and applied arenas. We are able to provide our partners with both one-of-a-kind testing platforms as well as world-class analytics.

14 SOLAR ENERGY↗

Thermoplastic Space Point Design (TSPD) Tall Tower Lunar Thermal Analysis

The Thermoplastics Development for Exploration Applications (TDEA) project seeks to advance NASA’s thermoplastic composites capabilities by developing structurally efficient joining solutions for large-scale space structures to support NASA’s future exploration missions. A key objective is to develop and understand advanced thermoplastic joining techniques relevant to space environments and applicable to unitized and/or reconfigurable composite structures. The TDEA project uses NASA Langley’s Tall Lunar Tower (TLT) concept as a target application for the design and development of in-space assembled thermoplastic composites. TLT is a 50-meter-tall tower constructed on the lunar surface near the south pole. The tower’s height at this location on the moon allows for extended durations of incident solar flux which can be used to generate power via photovoltaic arrays. The thermal environment present on lunar south pole represents a challenging environment for any space-based asset. This study provides an overview of the analysis techniques used to determine the temperature extremes, gradients, and timelines of a tall composite tower over a one-year duration at the Shackleton Connecting Ridge. The developed thermal model includes tower and lunar surface elements with anisotropic and temperature-dependent material properties and incorporates a solar vector orbit with time-varying solar flux. Study topics include: a comparison between the effects of simplified lunar surface topologies on thermal results, prediction of surface temperature values versus Lunar Reconnaissance Orbiter (LRO) flight data, and tower structural-thermal deformation.

Lunar↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗

The Mount Wilson magnetograph

In the summer of 1957, an instrument quite similar to the prototype solar magnetograph described by Babcock (1953) was installed at the 150-foot tower telescope at the Mount Wilson Observatory, and daily magnetograph observations of the full disk of the sun were started. During the following years, the instrument was modified and improved on several occasions. The present investigation is concerned with the present state of the magnetograph, which was largely rebuilt during 1981. Attention is given to the spectrograph entrance slit, the diffraction grating, the exit slit, the employed microprocessor, the setup procedure, the magnetic signal, the Doppler signal, and a solar magnetogram.

Howard, R.↗

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗

Modeling Wind in Agrivoltaics and its Impact on Eddy Covariance Flux Measurements

Silicon Ranch is conducting a research study at their 138MW Bancroft Station agrivoltaics site, the largest agrivoltaics research array in the US, in which they are using an eddy covariance flux tower to measure the carbon budget. They are interested in finding out if the presence of the panels changes the effectiveness of these measurements. To investigate this topic, NLR performed numerical simulations of wind through the agrivoltaic array to identify under what environmental conditions (wind speed, wind direction, temperatures) and panel tilt angles the mean wind speeds at the measurement heights are significantly altered by the presence of the solar panels. NLR adapted and used the PVade simulation tool [1] to model wind in Silicon Ranch's agrivoltaic array and found that at the height of the flux tower (6m), the wind speed measured is not significantly altered by the presence of solar panels. The percent difference is less than 4% and is generally greatest during daytime conditions at higher wind speeds and perpendicular wind direction. Closer to the ground, the flow is significantly altered (wind speeds are reduced) by the presence of solar panels and the percent difference increases in strong winds. The work confirmed that eddy covariance flux towers can be used within the context of a solar array field.

14 SOLAR ENERGY↗

Study of Systems and Technology for Liquid Hydrogen Production Independent of Fossil Fuels

Based on Kennedy Space Center siting and logistics requirements and the nonfossil energy resources at the Center, a number of applicable technologies and system candidates for hydrogen production were identified and characterized. A two stage screening of these technologies in the light of specific criteria identified two leading candidates as nonfossil system approaches. Conceptual design and costing of two solar-operated, stand alone systems, one photovoltaic based on and the other involving the power tower approach reveals their technical feasibility as sited as KSC, and the potential for product cost competitiveness with conventional supply approaches in the 1990 to 1210 time period. Conventional water hydrolysis and hydrogen liquefaction subsystems are integrated with the solar subsystems.

Sprafka, R. J.↗

Earth-to-Geostationary Orbit Transportation for Space Solar Power System Development

Space solar power satellites have the potential to provide abundant quantities of electricity for use on Earth. One concept, the Sun Tower, can be assembled in geostationary orbit from pieces transferred from Earth. The cost of transportation is one of the major hurdles to space solar power. This study found that autonomous solar-electric transfer is a good choice for the transportation from LEO to GEO.

Martin, James A.↗

Validation Assessment for the Soil Moisture Active Passive (SMAP) Level 4 Carbon (L4_C) Data Product Version 5

The post-launch Cal/Val phase of the SMAP mission is guided by two primary objectives for each science product team: 1) to calibrate, verify, and improve the performance of the science algorithms, and 2) validate accuracies of the science data products as specified in the SMAP Level-1 mission science requirements. Algorithm science and product maintenance activities during the SMAP extended mission phase have also involved periodic algorithm calibration and product refinements to maintain or enhance product consistency and performance as well as science utility. This report provides an assessment of the latest (Version 5) SMAP Level 4 Carbon (L4_C) product. The L4_C Version 5 (v5) global record now spans more than six years (March 2015 – present) of SMAP operations and has benefited from five major reprocessing updates to the operational product. These reprocessing events and L4_C product release updates have incorporated various algorithm refinements and calibration adjustments to account for similar refinements to the upstream GEOS land model assimilation system, SMAP brightness temperatures, and MODIS vegetation inputs used for L4_C processing. The SMAP L4_C algorithms utilize a terrestrial carbon flux model informed by daily surface and root zone soil moisture information contributed from the SMAP Level 4 Soil Moisture (L4_SM) product along with optical remote sensing-based (e.g. MODIS-based) land cover and canopy fractional photosynthetic active radiation (fPAR), and other ancillary biophysical data. The carbon flux model estimates global daily net ecosystem CO2 exchange (NEE) and the component carbon fluxes, namely, vegetation gross primary production (GPP) and soil heterotrophic respiration (Rh). Other L4_C product elements include surface (~0-5 cm depth) soil organic carbon (SOC) stocks and associated environmental constraints to these processes, including soil moisture-related controls on GPP and ecosystem respiration (Kimball et al. 2014, Jones et al. 2017). The L4_C product addresses SMAP carbon cycle science objectives by: 1) providing a direct link between terrestrial carbon fluxes and underlying freeze/thaw and soil moisture-related constraints to these processes, 2) documenting primary connections between terrestrial water, energy and carbon cycles, and 3) improving understanding of terrestrial carbon sink activity. The SMAP L4_C algorithms and operational product are mature and at a CEOS Validation Stage 4 level (Jackson et al. 2012) based on extensive validation of the multi-year record against a diverse array of independent benchmarks, well characterized global performance, and systematic refinements gained from five major reprocessing events. There are no Level-1 mission science requirements for the L4_C product; however, self-imposed requirements have been established focusing on NEE as the primary product field for validation, and on demonstrating L4_C accuracy and success in meeting product science requirements (Jackson et al. 2012). The other L4_C product fields also have strong utility for carbon science applications (e.g., Liu et al. 2019, Endsley et al. 2020); however, analysis of these other fields is considered secondary relative to primary validation activities focusing on NEE. The L4_C targeted accuracy requirements are to meet or exceed a mean unbiased root-mean-square error (ubRMSE, or standard deviation of the error) for NEE of 1.6 g C m-2 d-1 and 30 g C m-2 yr-1, emphasizing northern (≥45°N) boreal and arctic ecosystems; this accuracy is similar to that of tower eddy covariance measurement-based observations (Baldocchi 2008). Methods used for the latest v5 L4_C product performance and validation assessment have been established from the SMAP Cal/Val plan and previous studies (Jackson et al. 2012, Jones et al. 2017) and include: 1) consistency evaluations of the product fields against earlier product releases (version 4 or earlier); 2) comparisons of daily carbon flux estimates with independent tower eddy 4covariance measurement-based daily carbon (CO2) flux observations from core tower validation sites (CVS); and 3) consistency checks against other global carbon products, including soil carbon inventory records, global GPP records derived from tower observation upscaling methods, and satellite-based observations of canopy solar induced chlorophyll fluorescence (SIF) as a surrogate for GPP. Metrics used to evaluate relative agreement between L4_C product fields and observational benchmarks include correlation (r-value), RMSE differences, bias and model sensitivity diagnostics. Following these validation criteria, the present report provides a validation assessment of the latest L4_C product release (v5). Detailed descriptions of the L4_C algorithm and additional global product accuracy and performance results are given elsewhere (Jones et al. 2017, Endsley et al. 2020). The v5 L4_C product replaces earlier product versions and continues to show: (i) accuracy and performance levels meeting or exceeding SMAP L4_C science requirements; (ii) improvement over the previous product version (version 4); and (iii) suitability for a diversity of science applications. Example L4_C applications from the recent literature include clarifying environmental trends and controls on the northern terrestrial carbon sink (Liu et al. 2019), diagnosing drought-related impacts on ecosystem productivity (Li et al. 2020), and regional monitoring of cropland conditions for projecting annual yields (Wurster et al. 2020). 2EXPECTED L4_C ALGORITHM AND PRODUCTPERFORMANCE The L4_C algorithm performance, including variance and uncertainty estimates of model outputs, was determined during the mission pre-launch phase through spatially explicit model sensitivity studies using available model inputs similar to those currently being used for operational production and evaluating the resulting model simulations over the observed range of northern (≥45 °N) and global conditions (Kimball et al. 2012, Entekhabi et al. 2014). The L4_C algorithm options were also evaluated during the mission prelaunch phase, including deriving canopy fPAR from lower order NDVI (Normalized Difference Vegetation Index) inputs in lieu of using MODIS (MOD15) fPAR; and including an explicit model representation of boreal fire disturbance recovery impacts. These results indicated that the L4_C accuracy requirements (i.e., NEE ubRMSE ≤ 30 g C m-2 yr-1or ≤ 1.6 g C m-2 d-1) could be met from the baseline algorithms over more than 82% and 89% of global and northern vegetated land areas, respectively (Yi et al. 2013, Kimball et al. 2014). The global L4_C algorithm error budget for NEE derived during the mission prelaunch phase indicated that the estimated NEE ubRMSE uncertainty is proportional to GPP and is therefore larger in higher biomass productivity areas, including forests and croplands (Kimball et al. 2014). Likewise, NEE ubRMSE uncertainty is expected to be lower in less-productive areas, including grasslands and shrublands. Expected model NEE ubRMSE levels were also generally within targeted accuracy levels for characteristically less-productive boreal and Arctic biomes, even though relative model error as a proportion of total productivity (NEE RMSE / GPP) may be large in these areas. The estimated NEE uncertainty was lower than expected in some warmer tropical high biomass productivity areas (e.g. Amazon rainforest) because of reduced low temperature and moisture constraints to the L4_C respiration calculations so that the bulk of model uncertainty is contributed by GPP in these areas. Model NEE uncertainty in the African Congo was estimated to

SMAP↗