Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Observation of Seeded Mn K β Stimulated X-Ray Emission Using Two-Color X-Ray Free-Electron Laser Pulses

Kβ x-ray emission spectroscopy is a powerful probe for electronic structure analysis of 3d transition metal systems and their ultrafast dynamics. Selectively enhancing specific spectral regions would increase this sensitivity and provide fundamentally new insights. Recently we reported the observation and analysis of Kα amplified spontaneous x-ray emission from Mn solutions using an x-ray free-electron laser to create the 1s core-hole population inversion [Kroll et al., Phys. Rev. Lett. 120, 133203 (2018)]. To apply this new approach to the chemically more sensitive but much weaker Kβ x-ray emission lines requires a mechanism to outcompete the dominant amplification of the Kα emission. Here we report the observation of seeded amplified Kβ x-ray emission from a NaMnO 4 solution using two colors of x-ray free-electron laser pulses, one to create the 1s core-hole population inversion and the other to seed the amplified Kβ emission. Comparing the observed seeded amplified Kβ emission signal with that from conventional Kβ emission into the same solid angle, we obtain a signal enhancement of more than 10 5 . Finally, our findings are the first important step of enhancing and controlling the emission of selected final states of the Kβ spectrum with applications in chemical and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of the p η ' Cusp in the New Precise Beam Asymmetry Σ Data for γ p → p η

Data on the beam asymmetry Σ in the photoproduction of η mesons off protons are reported for tagged photon energies from 1130 to 1790 MeV (mass range from W = 1748 MeV to W = 2045 MeV). The data cover the full solid angle that allows for a precise moment analysis. For the first time, a strong cusp effect in a polarization observable has been observed that is an effect of a branch-point singularity at the pη' threshold [E γ = 1447 MeV (W = 1896 MeV)]. Here, the latest BnGa partial wave analysis includes the new beam asymmetry data and yields a strong indication for the N(1895)1/2 – nucleon resonance, demonstrating the importance of including all singularities for a correct determination of partial waves and resonance parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quest for Cooper Pair Transfer in Heavy-Ion Reactions: The 206 Pb + 118 Sn Case

In this Letter we report on effects of nucleon-nucleon correlations probed in nucleon transfer reactions with heavy ions. We measured with high efficiency and resolution a complete set of observables for neutron transfer channels in the ²⁰⁶Pb + ¹¹⁸Sn system employing a large solid angle magnetic spectrometer, which allowed us to study a wide range of internuclear distances via a detailed excitation function. The coupled channel theory, based on an independent particle transfer mechanism, follows the experimental transfer probabilities for one- and two-neutron pick-up and stripping channels. The experimental two-neutron transfer cross sections indicate that in reactions between pair-vibrational (closed shell) and pair-rotational (open shell) nuclei, correlations manifest via pair-addition and pair-removal modes, which constitute one of the elementary modes of excitations in nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-driven ion and electron acceleration from near-critical density gas targets: Towards high-repetition rate operation in the 1 PW, sub-100 fs laser interaction regime

Ion acceleration from gaseous targets driven by relativistic-intensity lasers was demonstrated as early as the late 1990s, yet most of the experiments conducted to date have involved picosecond-duration, Nd:glass lasers operating at low repetition rate. Here, we present measurements on the interaction of ultraintense ( ≈ 10 20 W cm − 2 , 1 PW ) , ultrashort ( ≈ 70 fs ) Ti:Sa laser pulses with near-critical ( ≈ 10 20 cm − 3 ) helium gas jets, a debris-free targetry with the potential for future compatibility with high ( ≈ 1 Hz ) repetition rate operation. We provide evidence of α particles being forward accelerated up to ≈ 2.7 − MeV energy with a total flux of ≈ 10 11 sr − 1 as integrated over > 0.1 − MeV energies and detected within a 0.5 − mrad solid angle. We also report on on-axis emission of relativistic electrons with an exponentially decaying spectrum characterized by a ≈ 10 − MeV slope, i.e., five times larger than the standard ponderomotive scaling. The total charge of these electrons with energy above 2 MeV is estimated to be of ≈ 1 nC , corresponding to ≈ 0.1 % of the laser drive energy. In addition, we observe the formation of a plasma channel, extending longitudinally across the gas density maximum and expanding radially with time. These results are well captured by large-scale particle-in-cell simulations, which reveal that the detected fast ions most likely originate from reflection off the rapidly expanding channel walls. The latter process is predicted to yield ion energies in the MeV range, which compare well with the measurements. Finally, direct laser acceleration is shown to be the dominant mechanism behind the observed electron energization. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collimating Montel mirror as part of a multi-crystal analyzer system for resonant inelastic X-ray scattering

Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L 3 -edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L 3 -absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel fabrication technique for high-resolution spherical crystal analyzers using a microporous aluminium base

Modern inelastic X-ray spectrometers employ curved, bent and diced analyzers to capture sufficiently large solid angles of radially emitted scattered radiation emanating from the sample. Fabricating these intricate analyzers, especially when a high energy resolution of a few millielectronvolts is required, is very time-consuming, expensive and often a hit-or-miss affair. A novel fabrication technique is introduced, utilizing a concave-spherical, microporous aluminium base to hold an assembly of a thin glass substrate with a diced crystal wafer bonded to it. Under uniform vacuum forces, the glass substrate is drawn into the aluminium base, achieving the desired bending radius, while dicing of the diffracting crystal layer prevents bending strain from being imposed on the individual crystal pixels. This technique eliminates the need for permanently bonding the crystal assembly to the concave lens, offering the opportunity for correcting figure errors, avoiding long-term degradation of the permanent bond, and making both lens and crystal reusable. Process and material costs are thus substantially decreased. Two analyzers, Si(844) and Ge(337) with intrinsic resolutions of 14.6 meV and 36.5 meV, respectively, were produced in this fashion and characterized in resonant inelastic X-ray scattering (RIXS) measurements. The achieved overall energy resolutions for both analyzers were 29.4 meV for Si(844) and 56.6 meV for Ge(337). Although the RIXS technique is veru sensitive to analyzer imperfections, the analyzers were found to be equal, if not superior, in quality to their traditional, permanently bonded counterparts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding the formation of multiply twinned structure in decahedral intermetallic nanoparticles

The structure of monometallic decahedral multiply twinned nanoparticles (MTPs) has been extensively studied, whereas less is known about intermetallic MTPs, especially the mechanism of formation of multiply twinned structures, which remains to be understood. Here, by using aberration-corrected scanning transmission electron microscopy, a detailed structural study of AuCu decahedral intermetallic MTPs is presented. Surface segregation has been revealed on the atomic level and the multiply twinned structure was studied systematically. Significantly different from Au and Cu, the intermetallic AuCu MTP adopts a solid-angle deficiency of −13.35°, which represents an overlap instead of a gap (+7.35° gap for Au and Cu). By analysing and summarizing the differences and similarities among AuCu and other existing monometallic/intermetallic MTPs, the formation mechanism has been investigated from both energetic and geometric perspectives. Finally, a general framework for decahedral MTPs has been proposed and unknown MTPs could be predicted on this basis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

60 APPLIED LIFE SCIENCES↗

Robust Containment Queries over Collections of Trimmed NURBS Surfaces via Generalized Winding Numbers

Here, we propose a containment query that is robust to the watertightness of regions bound by trimmed NURBS surfaces, as this property is difficult to guarantee for in-the-wild CAD models. Containment is determined through the generalized winding number (GWN), a mathematical construction that is indifferent to the arrangement of surfaces in the shape. Applying contemporary techniques for the 3D GWN to trimmed NURBS surfaces requires some form of geometric discretization, introducing computational inefficiency to the algorithm and even risking containment misclassifications near the surface. In contrast, our proposed method leverages properties of the 3D solid angle to solve the relevant surface integral using a boundary formulation with rapidly converging adaptive quadrature. Batches of queries are further accelerated by memoizing (i.e., caching and reusing) quadrature node positions and tangents as they are evaluated. We demonstrate that our GWN method is robust to complex trimming geometry in a CAD model, and is accurate up to arbitrary precision at arbitrary distances from the surface. The derived containment query is therefore robust to model non-watertightness while respecting all curved features of the input shape.

97 MATHEMATICS AND COMPUTING↗

Fast, High-Resolution X-ray Microfluorescence Imaging

X-ray micro fluorescence imaging refers to the use of an x-ray beam as a probe to excite XRF in a specimen and produce a spatially resolved image of the element distribution. The advantages of high sensitivity and low background, together with the nondestructive nature of the measurement, have lead to applications of x-ray microfluorescence analysis in biology, geology, materials science, as well as in the area of nondestructive evaluation. Previous reports have described the development of an x-ray microprobe which uses a conventional source of x-rays to produce a 10-μm beam. This paper describes improvements to the microprobe which have increased the beam power and the solid angle of detection. The data collection and display software have also been enhanced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

High Miller-Index Germanium Crystals For High-Energy X-ray Imaging Applications

Near-normal-incidence bent crystals are widely used for x-ray imaging applications. Advantages include high collection solid angle and potentially high efficiency for narrow-band sources, while disadvantages include relatively large (several Å) interatomic spacings and a limited number of suitable matches between a crystal 2d value and an integral multiple of useful emission line wavelengths. The disadvantages become more significant at x-ray energies >10 keV. The former disadvantage can be mitigated by using high-order reflections from crystal planes having low Miller indices, but both disadvantages can be mitigated by using low-order reflections from crystal planes having high Miller indices. We report here on integrated reflectivity measurements we performed of Ge (15,7,7) (2d=0.6296 Å), a candidate for imaging Ru He-α (θ(B)=87°). We find good agreement with calculations, and the data show a multitude of closely spaced reflections with slightly different Bragg angles including a fifth-order reflection of Ge (3,1,1) that has comparable reflectivity. This demonstrates that arbitrary choices of Miller indices in Ge crystals can be used to fine-tune Bragg angles for near-normal-incidence x-ray imaging at tens of kiloelectron volt x-ray energies with minimal lower-energy contamination from lower-order reflections, and that existing calculational tools can be used to reliably estimate integrated reflectivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-phonon coupling in AFM transition-metal mono-oxide

Time-of-flight INS measurements were performed on single crystal NiO with the Wide Angular Range Chopper Spectrometer (ARCS) at the Spallation Neutron Source. Experiments were performed on NiO single crystal mounted in an aluminum can and cooled using a closed-cycle helium refrigerator. Measurements were conducted at T = 100 K and 650 K, with the [HHL] scattering plane aligned horizontally. A Fermi chopper with slit spacing of 1.52mm, spinning at 300 Hz, was used to select an incident neutron energy of 100 meV. All datasets were normalized to a vanadium standard to correct for detector efficiency and solid angle coverage. The data sets include the .nxs files, the generated .hdf5 files (for use with Phonon Explorer), and Python scripts used to create them.

36 MATERIALS SCIENCE↗

Summary of the Effort to Use Active-induced Time Correlation Techniques to Measure the Enrichment of HEU

This document summarizes the effort to use active-induced time correlation techniques to measure the enrichment of bulk quantities of enriched uranium. In summary, these techniques use an external source to initiate fission chains, and the time distribution of the detected fission chain neutrons is sensitive to the fissile material enrichment. The number of neutrons emitted from a chain is driven by the multiplication of the item, and the enrichment is closely coupled to the multiplication of the item. As the enrichment increases (decreases), the multiplication increases (decreases) if the geometry is held constant. The time distribution of fission chain neutrons is a complex function of the enrichment and material configuration. The enrichment contributes to the probability of a subsequent fission in a chain via the likelihood of fissioning on an even-numbered isotope versus an odd-numbered isotope. The material configuration contributes to the same probability via solid angle effects for neutrons inducing subsequent fissions and the presence of any moderating material. To simplify the ability to accurately measure the enrichment, an associated particle imaging (API) D-T neutron generator and an array of plastic scintillators are used to simultaneously image the item and detect the fission chain neutrons. The image is used to significantly limit the space of enrichment and material configuration and enable the enrichment to be determined unambiguously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shockwave Arrival Times from Operation Redwing and Operation Upshot-Knothole

Back in the 1940s, 50s, and 60s, 210 nuclear tests were conducted in the atmosphere. As part of the testing program, EG&G performed shockwave arrival-time measurements for different shots in different operations using pressure transducers at different distances from ground zero. They then developed correlations unique to each set of data. They did not attempt to correlate all data onto one curve. As a fireball moves, material is picked up and pulled in, which is called entrainment. This extra material increases the mass of the fireball, and as the energy is spread out over a larger and larger mass, the specific internal energy of the fireball gases drops, which causes the temperature to drop as well. When the energy in the solid angle of a spherical shockwave hits the surface, it is reflected. Shortly thereafter, it catches up with the outward-moving shockwave and re-combines with it, causing it to expand at a slightly faster rate. As the shockwave grows, it approaches a hemispherical shape. The purpose of this project is to demonstrate that the shockwave arrival-time data can, in fact, be correlated onto a single function when the shockwave time-dependent solution is modified to include a geometric factor, θ, and is corrected for an entrainment coefficient.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗