Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Neutron spectrometer for ITER using silicon detectors

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency. Using annular silicon detectors, it is possible to greatly increase the solid angle coverage and hence improve efficiency. Based on a simulation (MCNPX) study, the scaling of energy resolution, efficiency, and time to determine an ion temperature to 10% accuracy on foil thickness and detector location is shown. The latter quantity is used to determine the optimum foil thickness and detector geometry for specific plasma temperatures. For a 20 keV deuterium-tritium (DT) plasma, 5.3% resolution with efficiency of 2.9x10{sup -4} n cm{sup 2} is attainable using the available detectors. This gives a temperature measurement with 10% accuracy in 1.1 ms for a neutron flux of 2x10{sup 9} n cm{sup -2}. Multiple detectors can be used to further increase the efficiency if needed. A system of this kind could be tested in a future DT campaign at, for example, JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of rain age via {gamma} rays from accreted radon progeny

The relative {gamma} ray activities from {sup 214}Pb and {sup 214}Bi condensed from precipitation are used to determine its 'age', the average time the accreted activity has been removed from secular equilibrium. A verifiable assumption that radon progeny on/in the surface/volume of droplets mostly remains in secular equilibrium until they begin their descent, enables estimates of their transit times to ground of typically a few tens of minutes. This agrees well with the time expected for the activity on the surface of droplets to reach the ground from heights of a few kilometers. The half lives of {gamma} activities from {sup 214}Bi and {sup 214}Pb, 19.7 and 26.9 min, respectively, are on the same scale as transit time to ground and close enough to each other to measure ratios of activities from secular equilibrium (1.00) to transient equilibrium (3.88) within a few hundreds of minutes. The ratio of {gamma} count rates is independent of knowledge of either initial activity or any systematic errors and thus limited only by the uncertainty from counting statistics, which from condensates of 5-30 l of rain viewed with 2{pi} solid angle by a 50% efficient, high-resolution Ge detector is only a few percent. These ratios fit extremely well to known theoretical curves, which cannot only be used to date rain but can also be extrapolated backward to determine radon progeny activities in rain prior to its descent, knowledge of which may facilitate further studies using radon progeny as tracers.

54 ENVIRONMENTAL SCIENCES↗

Coincidence-Summing Corrections for Close Geometry Measurements

For a given stellar temperature, nuclear reactions take place in the energy range of the Gamow window with the relatively low energies of the astrophysical interest for charged particle induced reactions. In order to measure the nuclear reaction cross sections with the activation method at projectile energies as low as possible, a gamma counting system that consists of Ge detectors and the irradiated target in close geometry is required. The presence of cascade transitions requires coincidence summing corrections that can not be ignored because of the very large solid angle. In this study, the determination of the summing correction factor and photopeak efficiency for a gamma spectrometer, as an example, composed of two Ge clover detectors in close geometry is briefly described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Magnetic Spectrometer PRISMA Combined With Large Gamma Arrays

The large solid angle magnetic spectrometer for heavy ions PRISMA was operated at LNL in conjunction with the highly efficient CLARA set-up up to the end of March 2008. The AGATA Demonstrator is being mounted around the target area of PRISMA replacing the CLARA set-up. It will allow to carry out nuclear structure and reaction mechanism studies with better resolution and higher statistics. New detectors for light ions and slow moving heavy ions have been designed for the focal plane of the spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-elastic reactions: a survey on recent results with PRISMA-CLARA

Binary reactions at energies close to the Coulomb barrier received recently a significant boost thanks to the advent of the large solid angle magnetic spectrometer PRISMA coupled to the {gamma} array CLARA. In the present paper different aspects of recent results of nuclear structure and reaction dynamics will be presented, focusing more closely on the reaction mechanism, in particular on the properties of quasi-elastic and deep inelastic processes and on studies aiming at getting information on nucleon-nucleon correlations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aspects of Heavy Ion Transfer Reactions

With the large solid angle magnetic spectrometer PRISMA coupled to the {gamma} array CLARA extensive investigations have been carried out for nuclear structure and reaction dynamics. In the present paper aspects of these studies will be presented, focusing more closely on the reaction mechanism, in particular on the properties of quasi-elastic and deep-inelastic processes and on measurements at energies far below the Coulomb barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft X-ray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 {mu}m square. The array detector is mounted on a liquid cryogen-free {sup 3}He cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of {approx}0.01 sr and a maximum counting rate of more than 1 M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Future Perspectives for the Application of Low Temperature Detectors in Heavy Ion Physics

Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics is given, and the next generation heavy ion facility FAIR is described with a special emphasis on the potential advantage of Low Temperature Detectors (LTDs) for applications in heavy ion physics. For prototype LTDs for the energy sensitive detection of heavy ions excellent results with respect to energy resolution down to {delta}E/E = 1-2x10{sup -3} for a wide range of incident energies, and with respect to other detector properties, such as energy linearity with no indication of pulse height defects even for the heaviest ions, have been obtained. In addition, prototype detectors for hard X-rays have shown energy resolutions down to {delta}E = 30-40eV at 60 keV. Consequently, both detector schemes have already been successfully used for first experiments. At present, the design and setup of large solid angle detector arrays is in progress. With the already achieved performance, LTDs promise a large potential for applications in atomic and nuclear heavy ion physics. A brief overview of prominent examples, including high-resolution nuclear spectroscopy, nuclear structure studies with radioactive beams, superheavy element research, as well as high-resolution atomic spectroscopy on highly charged ions and tests of QED in strong electromagnetic fields is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time of flight elastic recoil detection analysis with a position sensitive detector

A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MUSIC Project

A new muon channel, MUSIC, is being constructed at the Research Center for Nuclear Physics (RCNP) at Osaka University in Japan. The muon channel utilizes a strong solenoidal magnetic field to collect pions and to transport muons. A large-bore superconducting coil encloses the pion-production target to capture pions with a large solid angle. A long solenoid magnet transports pions and muons with the capability to select the charge and momentum of the particles. The design of the solenoid channel is described in this paper.

43 PARTICLE ACCELERATORS↗

Quasi-elastic reactions: a survey on recent results

Binary reactions at energies close to the Coulomb barrier received recently a significant boost thanks to the advent of the large solid angle magnetic spectrometer PRISMA coupled to the gamma array CLARA. In the present paper different aspects of the recent results of nuclear structure and reaction dynamics will be presented, focusing more closely on the reaction mechanism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A rotatable electron spectrometer for multicoincidence experiments

We have developed a rotatable hemispherical spectrometer with good energy and angular resolution, which can be positioned with the lens axis arbitrarily within a solid angle of 1 {pi}. The collection angle of the emitted electrons with respect to the polarization axis of the light is set by means of a three-axes goniometer, operating under vacuum. An important requirement for this setup was the possibility to perform coincidences between the electron analyzed by the spectrometer and one or several other particles, such as ions, electrons, or photons. The lens system and the hemispheres have been designed to accommodate such experimental demands, regarding parameters such as the resolving power, the acceptance angle, or the width of the kinetic energy window which can be recorded for a given pass energy. We have chosen to detect the impact position of the electron at the focal plane of the hemispherical analyzer with a delay line detector and a time-to-digital converter as acquisition card rather than using a conventional charge-coupled device camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Asymmetries in {pi}{sup 0} Photoproduction on the Proton

Polarization observables, such as the beam asymmetry {Sigma}, are vital to the study of the many N* and {Delta} resonances that decay to the p{pi}{sup 0} final state. Beam asymmetries in {pi}{sup 0} photoproduction off the proton have been determined using the Crystal Barrel CsI(Tl) calorimeter at ELSA, University of Bonn in Germany, in the energy range E{gamma} = 920 to 1680 MeV by analyzing the neutral decay mode {pi}{sup 0{yields}{gamma}{gamma}}. In this experiment, the BaF{sub 2} spectrometer TAPS was placed in the forward direction increasing the solid angle coverage to nearly 4{pi} and serving as a fast trigger. For the first time, these measurements include the most forward angles in {theta}{sub {pi}}{sup 0c{center_dot}m}. Additionally, this analysis provides new data points in the energy range E{gamma} = 1510 to 1680 MeV where few measurements have previously been made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a new high repetition rate Nd:YAG Thomson scattering system for Heliotron J

A new high repetition rate Nd:YAG Thomson scattering system has been designed for the Heliotron J helical device. The main purpose of installing the new Thomson scattering system is an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with {approx}10 mm resolution. Two high repetition Nd:YAG lasers (>550 mJ at 50 Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time interval. Scattered light is collected with a large concave mirror (D=800 mm, f/2.25) with a solid angle of {approx}100 msr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected (scattering angle is 20 deg.). Model simulation of the polychromator shows the measurable electron temperature and density range are from10 eV to 10 keV, >5x10{sup 18} m{sup -3} within 3% error for the temperature measurement, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Status of the Superomega Muon Beamline

The Superomega muon beamline is currently under construction at Experimental hall No. 2 of the Materials and Life Science Facility at J-PARC in Tokai, Japan. The beamline has a large solid angle acceptance, and will produce the highest intensity pulsed muon beam in the world. The beamline is designed to capture both surface positive and cloud negative muons for simultaneous use in a variety of experiments. The expected rate of surface muons for this beamline is 4x10{sup 8}{mu}{sup +}/s, and that for cloud muons is 10{sup 7}{mu}{sup -}/s. The beamline consists of the normal-conducting capture solenoid, the superconducting curved transport solenoid and axial focusing solenoid. The construction of the capture solenoid has been completed and installed in March 2009, and the transport solenoid is now fabricated, and will be installed in the summer of 2011. The calculation of the beamline optics of the axial focusing solenoid is underway.

43 PARTICLE ACCELERATORS↗

Neutron Time Projection Chamber for Nuclear Security and Verification Applications

Detection of fast neutrons produced by fission is a powerful method for discovering, verifying the presence, or monitoring significant quantities of special nuclear material (SNM) at up to moderate distances. Fast neutrons are relatively rare in the natural background and can be very penetrating, even in situations when the energetic gamma-rays are well shielded. Fast neutrons point in the direction of their source and can thus be considered for use in imaging, a feature desirable for rapid, high-signal-to-noise detection of concealed SNM and for nuclear verification. We describe the development and performance of a prototype neutron time projection chamber (nTPC) and its use for directional neutron detection and high-resolution neutron imaging. The nTPC is based on {approx}0.025 m{sup 3} of a hydrogen-methane mixture and utilizes a readout system with low channel count and is optimized for low event rates. We experimentally demonstrate robust operation, reliable particle identification, event-by-event directional reconstruction over the entire 4{pi} solid angle, and insensitivity to gamma-rays. High-efficiency and high-resolution modes of operation based on single and double neutron scatters, respectively, have also been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV negative ion source from ultra-intense laser-matter interaction

Experimental demonstration of negative ion acceleration to MeV energies from sub-micron size droplets of water spray irradiated by ultra-intense laser pulses is presented. Thanks to the specific target configuration and laser parameters, more than 10{sup 9} negative ions per steradian solid angle in 5% energy bandwidth are accelerated in a stable and reliable manner. To our knowledge, by virtue of the ultra-short duration of the emission, this is by far the brightest negative ion source reported. The data also indicate the existence of beams of neutrals with at least similar numbers and energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗