Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sound pressure level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Innovative Approach for Developing Spacecraft Interior Acoustic Requirement Allocation

The Orion Multi-Purpose Crew Vehicle (MPCV) is an American spacecraft for carrying four astronauts during deep space missions. This paper describes an innovative application of Power Injection Method (PIM) for allocating Orion cabin continuous noise Sound Pressure Level (SPL) limits to the sound power level (PWL) limits of major noise sources in the Environmental Control and Life Support System (ECLSS) during all mission phases. PIM is simulated using both Statistical Energy Analysis (SEA) and Hybrid Statistical Energy Analysis-Finite Element (SEA-FE) models of the Orion MPCV to obtain the transfer matrix from the PWL of the noise sources to the acoustic energies of the receivers, i.e., the cavities associated with the cabin habitable volume. The goal of the allocation strategy is to control the total energy of cabin habitable volume for maintaining the required SPL limits. Simulations are used to demonstrate that applying the allocated PWLs to the noise sources in the models indeed reproduces the SPL limits in the habitable volume. The effects of Noise Control Treatment (NCT) on allocated noise source PWLs are investigated. The measurement of source PWLs of involved fan and pump development units are also discussed as it is related to some case-specific details of the allocation strategy discussed here.

Chu, S. Reynold↗

Differential sound level meter

Small differences between relatively high sound pressure levels at two different microphone sites are measured by a device which provides electrical insertion voltages (pilot voltages) as a a means for continuously monitoring the gains of two acoustical channels. The difference between two pilot voltages is utilized to force the gain of one channel to track the other channel.

Zuckerwar, A. J.↗

Enhancement of Far Field Sound Levels by Refractive Focusing

The enhancement of sound pressure levels resulting from refractive focusing was calculated for meteorological conditions representative of those observed at the MOD-1 site near Boone, N.C. The results show that 10 to 20dB enhancements can occur over ranges of several hundred meters. Localized enhancements in excess of 20dB can occur but will probably be of limited duration as a consequence of normal temporally varying meteorological conditions.

Thomson, D. W.↗

Noise tests of a high-aspect-ratio slot nozzle with various V-gutter target thrust reversers

The results of experiments on the noise generated by a 1.33- by 91.4 cm slot nozzle with various V-gutter reversers, and some thrust measurements are presented. The experiments were conducted with near-ambient temperature jets at nozzle pressure ratios of 1.25 to 3.0, yielding jet velocities of about 190 to 400 m/sec. At pressure ratios of 2 or less, the reversers, in addition to being noisier than the nozzle alone, also had a more uniform directional distribution and more high-frequency noise. At pressure ratios above 2, the nozzle alone generated enough shock noise that the levels were about the same as for the reversers. The maximum overall sound pressure level and the effective overall sound power level both varied with the sixth power of jet velocity over the range tested. The data were scaled up to a size suitable for reversing the wing-flap slot nozzle flow of a 45 400-kg augmentor-wing-type airplane on the ground, yielding perceived noise levels well above 95 PNdB on a 152-m sideline.

Stone, J. R.↗

Noise tests of a high-aspect-ratio slot nozzle with various V-gutter target thrust reversers

The results of experiments on the noise generated by a 1.33 x 91.4 cm slot nozzle with various V-gutter reversers are presented. The experiments were conducted with near-ambient temperature jets at nozzle pressure ratios of 1.25 to 3.0, yielding jet velocities of about 190 to 400 m/sec. At pressure ratios of 2 or less, the reversers, in addition to being noisier than the nozzle alone, also had a more uniform directional distribution and more high-frequency noise. At pressure ratios above 2, the nozzle alone generated enough shock noise that the levels were about the same as for the reversers. The maximum overall sound pressure level and the effective overall sound power level both varied with the sixth power of jet velocity over the range tested.

Stone, J. R.↗

Concorde noise-induced building vibrations: John F. Kennedy International Airport

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

Mayes, W. H.↗

Analysis of noise measured from a propeller in a wake

In this experimental study, the acoustic characteristics of a propeller operating in a wake were studied. The propeller performance and noise were measured from two 0.25 scale propellers operating in an open jet anechoic flow environment with and without a wake. One propeller had NACA 16 series sections; the other, ARA-D. Wake thicknesses of 1 and 3 propeller chords were generated by an airfoil which spanned the full diameter of the propeller. The airfoil wake profiles were measured. Noise measurements were made in and out of the flow. The propellers were operated at 40, 83, and 100 inf of thrust. The acoustic data are analyzed, and the effects on the overall sound pressure level (OASPL) and scaled A weighted sound level L sub A with propeller thrust, wake thickness, and observer location are presented. The analysis showed that, generally, the wake increased the overall noise (OASPL) produced by the propeller; increased the harmonic content of the noise, thus the scaled L sub a; and produced an azimuthal dependence. With few exceptions, both propellers generally produced the same trends in delta OASPL and delta L sub a with thrust and wake thickness.

Block, P. J. W.↗

Advanced turboprop aircraft noise annoyance - A review of recent NASA research

Passenger and community response to advanced turboprop aircraft noise are studied. Four experiments were conducted utilizing an aircraft noise synthesis system, an exterior effects room, an anechoic listening room, and a Space Station/aircraft acoustic apparatus; the experimental conditions and procedures for the psychoacoustic studies are described. The community noise studies involved evaluating the effects of various tonal characteristics on annoyance. It was observed that the frequency envelope shape did not effect annoyance; however, the interaction of the fundamental frequency with tone-to-broadband noise ratio did have a large effect on annoyance. The effects of low frequency tones, turbulent boundary layer noise, and tonal beats on passenger annoyance are investigated. The data reveal that passenger annoyance is greater for a given level of boundary layer noise when tones are at levels sufficient to increase the overall sound pressure level within the cabin. The annoyance response of an advanced turboprop and a conventional aircraft are compared. It is determined that the flyover noise level for the turboprop aircraft is not more annoying than that of a conventional aircraft.

Mccurdy, D. A.↗

Light aircraft sound transmission studies - Noise reduction model

Experimental tests conducted on the fuselage of a single-engine Piper Cherokee light aircraft suggest that the cabin interior noise can be reduced by increasing the transmission loss of the dominant sound transmission paths and/or by increasing the cabin interior sound absorption. The validity of using a simple room equation model to predict the cabin interior sound-pressure level for different fuselage and exterior sound field conditions is also presented. The room equation model is based on the sound power flow balance for the cabin space and utilizes the measured transmitted sound intensity data. The room equation model predictions were considered good enough to be used for preliminary acoustical design studies.

Atwal, Mahabir S.↗

Meteorological effects on long-range outdoor sound propagation

Measurements of sound propagation over distances up to 1000 m were carried out with an impulse sound source offering reproducible, short time signals. Temperature and wind speed at several heights were monitored simultaneously; the meteorological data are used to determine the sound speed gradients according to the Monin-Obukhov similarity theory. The sound speed profile is compared to a corresponding prediction, gained through the measured travel time difference between direct and ground reflected pulse (which depends on the sound speed gradient). Positive sound speed gradients cause bending of the sound rays towards the ground yielding enhanced sound pressure levels. The measured meteorological effects on sound propagation are discussed and illustrated by ray tracing methods.

Klug, Helmut↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in "Predicting Rocket or Jet Noise in Real Time" (SSC-00215-1), which appears elsewhere in this issue of NASA Tech Briefs. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro-ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1/3-octave spectrograms.

Anderson, Paul D.↗

Wireless Acoustic Measurement System

A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server can control the operations of the field stations for calibration and for recording of measurement data. A test engineer positions and activates the WAMS. The WAMS automatically establishes the wireless network. Next, the engineer performs pretest calibrations. Then the engineer executes the test and measurement procedures. After the test, the raw measurement files are copied and transferred, through the wireless network, to a hard disk in the control server. Subsequently, the data are processed into 1.3-octave spectrograms.

Anderson, Paul D.↗

Noise and static performance characteristics of a STOL aircraft jet flap

Static noise and performance tests were conducted on a 1/4-scale jet flap model with a multilobe nozzle of array area ratio of 2.7. The model nozzle and flap tested were a two-dimensional section of a distributed blowing system similar to previously investigated augmentor wing systems without the upper shroud and intake door. Noise data were measured with the nozzle alone and also during attached flow conditions with the flap at two turning angles representing takeoff and approach conditions. The noise data are scaled to a 200,000-lb TOGW four-engine airplane and are presented in terms of perceived noise level and one-third octave band sound pressure level. Comparisons are made with the noise levels produced by an augmentor wing airplane fitted with a three-element acoustically lined augmentor flap. The static performance is presented in terms of thrust recovery and effective turning angle.

Harkonen, D. L.↗

Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)

The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishing/verifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.

Qualification↗

Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)

The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishingverifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.

Testing↗

Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)

The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishingverifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.

Qualification↗

Noise and performance characteristics of a model scale X-wing rotor system in hover

Noise data for the hover condition were measured for a 8 m diameter X-wing model rotor mounted on an outdoor whirl tower. The noise was found to be a function of operating condition, in general increasing with performance. The X-wing spectra obtained from narrowband and 1/3-octave band analyses were dominated by the blade passage frequency harmonics. The circulation control slot blowing produced 1 to 10 kHz broadband noise which exhibited a jet velocity to the 5.4 dependency. Under the rotor plane loading noise was dominant, except at low values of blade pressure ratio where a sharp decrease in the blade passage frequency harmonic levels was observed. In the rotor plane, the contribution of the broadband noise sources was greater than under the rotor plane. The X-wing rotor system in hover exhibited flexibility in operating conditions to achieve a specific level of performance. The high collective, low blade passage ratio combinations which meet a given level of performance were associated with low overall sound pressure levels.

Willshire, W. L., Jr.↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗