Search NASA⌕ Search

SEARCH · Search NASA

Results for “Specific conductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Vapor grown carbon fiber for space thermal management systems

Research that uses a novel, highly graphitic, vapor grown carbon fiber (VGCF) to fabricate composites for thermal management applications is described. These VGCF/Carbon composites have shown a specific thermal conductivity with values of twenty-to-ten times that of copper in the 500-900 K temperature range needed for waste heat management. It is concluded that development of this high specific thermal conductivity composite for thermal radiator panels will provide the foundation for a reevaluation of space power designs heretofore limited by the mass of waste heat dissipation systems. Further, it is suggested that through optimization of fiber handling and composite processing, thermal conductivities exceeding 1000 W/m-K (at 300 K) are achievable in composites reinforced with VGCF.

Lake, Max L.↗

Benchmark Specifications for Select Experiments Conducted at the Kansas State University Gallium Thermal-hydraulic Experiment Facility

The Department of Energy (DOE) – Nuclear Energy University Programs (NEUP) supported the creation and operation of the Gallium Thermal-hydraulic Experiment (GaTE) facility at Kansas State University (KSU) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. GaTE was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements describing stratification behavior in the coolant were collected for use as experimental benchmarks in validation efforts for computational models. The results of these tests contribute to a greater understanding of thermal stratification behavior of liquid metal under various configurations and operating conditions. This report provides a complete description of the benchmark problem, including all necessary details and description of a set of four forced flow and four natural circulation tests and measured data for comparison with model results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

Thermophysical properties of Apollo 12 fines.

The vacuum thermal conductivity of the Apollo 12 fines is presented as a function of temperature for densities of 1300, 1640 and 1970 kg/cu m. It is found to vary from about .001 W/m-K at 100 K to about .003 W/m-K at 400 K. The conductivity of the fines is found to be close to that of terrestrial basalt both under vacuum and at higher pressures. The thermal diffusivity is calculated from conductivity and specific heat data. Average values of the thermal conductivity, thermal diffusivity and thermal parameter are also presented.

Cremers, C. J.↗

Intrinsic anharmonicity and thermal properties of ultralow thermal conductivity Ba 6 Sn 6 Se 13

Ultralow thermal conductivity materials continue to be of great interest for technologically important applications such as thermal insulators and thermoelectrics. Often, such materials possess constituents with extensive dynamic disorder, or “rattlers,” or structural disorder such as metallic glasses. Nevertheless, targeted crystalline bonding order and anharmonicity can provide effective means for the scattering of the phonons in certain materials. Our combined experimental and theoretical investigation of Ba 6 Sn 6 Se 13 reveals such a material, with ultralow thermal conductivity measured over a large temperature range. Optic phonon modes hybridize with acoustic modes at relatively low energies resulting in strong acoustic-optic scattering and limited phonon lifetimes. Moreover, our investigations reveal various avoided crossings at low energies that contribute to phonon scattering. These are derived from chiral phase symmetries and may result in nontrivial topological behaviors for phonon band crossings in this chiral material. This work contributes to the ongoing research on low thermal conductivity materials and the underlying mechanisms that affect their thermal behaviors. Manipulation of these effects may provide pathways for enhancement of material properties for targeted thermal applications using similar materials.

36 MATERIALS SCIENCE↗

Leaf habit affects the distribution of drought sensitivity but not water transport efficiency in the tropics

Abstract Considering the global intensification of aridity in tropical biomes due to climate change, we need to understand what shapes the distribution of drought sensitivity in tropical plants. We conducted a pantropical data synthesis representing 1117 species to test whether xylem‐specific hydraulic conductivity (K S ), water potential at leaf turgor loss (Ψ TLP ) and water potential at 50% loss of K S (Ψ P50 ) varied along climate gradients. The Ψ TLP and Ψ P50 increased with climatic moisture only for evergreen species, but K S did not. Species with high Ψ TLP and Ψ P50 values were associated with both dry and wet environments. However, drought‐deciduous species showed high Ψ TLP and Ψ P50 values regardless of water availability, whereas evergreen species only in wet environments. All three traits showed a weak phylogenetic signal and a short half‐life. These results suggest strong environmental controls on trait variance, which in turn is modulated by leaf habit along climatic moisture gradients in the tropics.

54 ENVIRONMENTAL SCIENCES↗

The 1979 Southeastern Virginia Urban Plume Study. Volume 1: Description of experiments and selected aircraft data

The Southeastern Virginia Urban Plume Study (SEV-UPS) utilizes remote sensors and satellite platforms to monitor the Earth's environment and resources. SEV-UPS focuses on the application of specific remote sensors to the monitoring and study of specific air quality problems. The 1979 SEV-UPS field program was conducted with specific objectives: (1) to provide correlative data to evaluate the Laser Absorption spectrometer ozone remote sensors; (2) to demonstrate the utility of the sensor for the study of urban ozone problems; (3) to provide additional insights into air quality phenomena occuring in Southeastern Virginia; and (4) to compare measurement results of various in situ measurement platforms. The field program included monitoring from 12 surface stations, 4 aircraft, 2 tethered balloons, 2 radiosonde release sites, and numerous surface meteorological observation sites. The aircraft monitored 03, NO, NOX, Bscat, temperature, and dewpoint temperature.

Gregory, G. L.↗

Structural Damage and Recrystallization Response of Garnet Crystals to Intense Electronic Excitation

Here, the susceptibility to irradiation-induced damage, the fundamental mechanism of the relaxation kinetics, and the corresponding recrystallization effect related to the cation radius ratio are comprehensively investigated for Y 3 Al 5 O 12 and Gd 3 Ga 5 O 12 garnet crystals under 645 MeV Xe 35+ irradiation with different fluences of 5 × 10 11 –3 × 10 12 ions cm –2 . Regarding different lattice distortion and swelling levels, the observed microstructure transformations to disordered and amorphous phases, and corresponding hillock dimensions, consistently confirm that Gd 3 Ga 5 O 12 has a higher susceptibility to radiation damage than Y 3 Al 5 O 12 . Combined with iTS model calculations, although Y 3 Al 5 O 12 has higher atomic temperature and energy deposition than Gd 3 Ga 5 O 12 under the same ion velocity and electronic energy loss, the relatively high thermal conductivity and specific heat coefficient of Y 3 Al 5 O 12 crystals enhance the conduction and dissipation of deposition energy, and Gd 3 Ga 5 O 12 , with a higher cation-radius-ratio (r A /r B ), is more easily damaged to amorphous phase due to the less favorable kinetics of ordering and recovery of a melted track region to the crystalline phase. Additionally, the significant bandgap modification in spectral ranges of 5.88–6.75 eV for Y 3 Al 5 O 12 and 4.83–5.41 eV for Gd 3 Ga 5 O 12 , and the enhancement of defect-assisted-related luminescence are achieved, providing a basis to design novel optoelectronic devices in microelectronics fields.

36 MATERIALS SCIENCE↗

Modeling the cooldown of cryocooler conduction-cooled devices

Cryocooler conduction cooled devices can experience significant cooldown time due to lower available cooling capacity compares to convection cooled devices. Therefore, the cooldown time is an important design parameter for conduction cooled devices. This article introduces a framework developed in Python for calculating the cooldown profiles and cooldown time of cryocooler conduction-cooled devices such as superconducting magnets and accelerator cavities. The cooldown time estimation problem is essentially a system of ordinary first-order differential equations comprising the material properties (temperature dependent thermal conductivity and specific heat capacity) of the components intertwined with the prevailing heat transfer channels (conduction, radiation, and heat flow across pressed contacts) and the cryocooler capacity. The formulation of this ODE system is first presented. This ODE system is then solved using the in-built Python library odeint. A case study is presented comprising a small cryocooler conduction-cooled copper stabilized niobium-titanium magnet. The case study is supplemented with the Python script enabling the reader to simply tweak the device design parameters and optimize the design from the point of view of slow/fast cooldown.

43 PARTICLE ACCELERATORS↗

Thermal energy storage in concrete: Review, testing, and simulation of thermal properties at relevant ranges of elevated temperature

This study examines the thermal performance of concrete used for thermal energy storage (TES) applications. The influence of concrete constituents (aggregates, cementitious materials, and fibers) on the thermal conductivity and specific heat are summarized based on literature and via experimentation at elevated temperatures. It is indicated that concrete with siliceous aggregate, low water/cement ratios, and steel fibers produces better overall thermal properties. The results of literature review and laboratory testing are used for numerical simulation to evaluate the impact of concrete thermal property variability on TES capabilities. The TES module consists of the heat exchanger and surrounding concrete as the storage media. Both idealized cases without heat loss and realistic cases with insulation and heat losses are considered. Furthermore, the result shows that conventional concrete mixes can be tailored to decrease the module charge/discharge durations and increase the amount of thermal energy storage.

25 ENERGY STORAGE↗

Medium- and Heavy-Duty Vehicle Electrification: An Assessment of Technology and Knowledge Gaps

The objective of this assessment was to leverage current medium- and heavy-duty vehicle (MHDV) data and information to evaluate the state of commercial vehicle electrification technologies, including the following: 1. Assessment and inventory of current MHDV electrification architectures; 2. Identification and assessment of MHDV component technologies; 3. Assessment of potential performance and cost drivers; and, 4. Identification of R&D gaps where appropriate R&D and technology would accelerate commercial vehicle electrification. These gaps include shortfalls in technology, gaps in data, and inadequate knowledge and understanding. To inform this study, the National Renewable Energy Laboratory–Oak Ridge National Laboratory team examined the open literature; conducted workshops; assessed and analyzed data on more than 175 electrified MHDVs, including vehicle and powertrain specifications; and conducted one-on-one meetings with industry representatives. This systems-level information was concatenated and parsed with respect to key characteristics such as battery energy, power, and range compared across vehicle classes. Operational data of many conventional vehicles were also examined to help determine the requirements on electrified vehicle attributes such as range. Previous studies on the total cost of ownership of electrified MHDVs were reviewed to determine where improvements in technologies (efficiency, cost, maintenance) were needed to accelerate adoption. The team also assessed the state of the art in electric drivetrains for component specifications and challenges for the commercial vehicle sector, including electric machines, power electronics, and off-board high-power charging systems (extreme fast charging and beyond). The goal of this analysis was to identify the barriers to widespread adoption of commercial vehicle electrification technologies and prioritize the research and development gaps that need to be overcome to accelerate significant market penetration of these technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal transport measurements through the charge density wave transition in CsV 3 Sb 5

We study thermal transport and thermalization in single crystals of CsV 3 Sb 5 through the CDW transition by directly measuring thermal diffusivity (D), thermal conductivity (κ), specific heat (c), and resistivity (ρ). Commensurate with previous reports, we observe a sharp, narrow anomaly in specific heat associated with a first-order transition that results in a CDW state below ~94 K. While a corresponding sharp anomaly in thermal diffusivity is also observed, resistivity and thermal conductivity only exhibit small steps at the transition, where the feature is sharp for resistivity and broader for thermal conductivity. Scrutinizing the thermal Einstein relation κ = cD, we find that this relation is generally satisfied, except in the narrow two-phase regime of the putative first-order transition. Here, the Wiedemann-Franz law as well seems to work outside the two-phase regime, where strong resemblance between the specific heat and the resistivity derivative below the transition may point to a concurrent emergence of a secondary electronic order parameter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat conduction in metal-filled polymers - The role of particle size, shape, and orientation

This paper presents a new type of analysis for predicting the thermal conductivity of disperse composites from the properties of the component phases and elementary characterizations of particle shapes and orientation. This analysis successfully predicted the sensitivity to particle shape which was confirmed by experiments also reported in this paper. These results suggest that highly elongated particles may be used to achieve dramatic modifications of thermal conductivity and the analysis presented here may be a useful tool in the design or development of disperse composites of specific thermal conductivity. The analysis may also apply to other properties such as electrical conductivity or magnetic permeability.

Hansen, D.↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crewmembers will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crewmember breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements during the beginning of and throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests, with each test lasting 2.5 hours and involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry Laboratory at the NASA Lyndon B. Johnson Space Center. The majority of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, and acetaldehyde. A fire cartridge is exposed to the test gas in a test chamber at the specified conditions and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work, then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the conduction of the challenge tests, a general summary of the performance of the fire cartridges will be provided.

Fire Cartridge↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crew members will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crew member breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry- Laboratory at the NASA Lyndon B. Johnson Space Center. Many of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, ammonia (NH3), and acetaldehyde. A fire cartridge is exposed to the test gas in a chamber at the specified conditions, and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work and will then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the challenge tests, a general summary of the performance of the fire cartridges will also be provided.

Cristina M. Muko↗

Ion specific, thin film confinement effects on conductivity in polymerized ionic liquids.

Acrylate-based polymerized ionic liquids (PILs) with ammonium (Am) or imidazolium (Im) cations and tetrafluoroborate (BF4) or bis(trifluoromethanesulfonyl)imide (TFSI) anions were synthesized and spin coated onto gold interdigitated electrodes on silica to investigate nanoconfinement effects on ion transport. The film thickness ranged from 23 to 313 nm. A significant reduction of the in-plane conductivity was observed in some PIL thin films with thickness below 100 nm. Specifically, Am BF4 PIL showed the largest conductivity drop (ca. 50% difference between a 22 nm and a 261 nm film) while Im TFSI PIL showed almost no change under confinement. The difference in conductivity drop is discussed in terms of (i) differences in interfacial layer thickness by fitting a two-layer conductivity model and (ii) potential changes in glass transition temperature (T-g) under confinement, which were estimated using the Vogel-Fulcher-Tammann fits of bulk conductivities. Decreasing film thickness also caused the dielectric loss peaks to shift to lower frequency, indicating that the ion diffusion process slowed under confinement.

Zhao, Qiujie↗