Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Symplectic machine learning model for fast simulation of space-charge effects

Symplectic simulation of space-charge effects is crucial for the design and operation of high-intensity particle accelerators. Traditional methods for simulating these effects are often computationally expensive, resulting in significant overhead. In this work, we introduce a generative model based on a U-Net architecture within a generative adversarial network framework to efficiently simulate space-charge effects. The model is trained to predict the transverse multiparticle space-charge Hamiltonian, which can be physically computed using a gridless spectral method. The one-step symplectic transverse transfer map for the particles is then obtained by differentiating the predicted Hamiltonian. Benchmarking results demonstrate that this generative model achieves an order of magnitude higher computational efficiency compared to the spectral method, providing a highly efficient alternative for simulating space-charge effects with a large number of particles. By maintaining symplecticity, the model effectively preserves the phase-space structure and mitigates nonphysical errors in long-term simulations. This model has been integrated into jutrack, a novel autodifferentiable accelerator modeling code developed in the julia programming language.

Beam code development & simulation techniques↗

KADATH: A spectral solver for theoretical physics

KADATH is a library that implements spectral methods in a very modular manner. It is designed to solve a wide class of problems that arise in the context of theoretical physics. Several types of coordinates are implemented and additional geometries can be easily encoded. Partial differential equations of various types are discretized by means of spectral methods. The resulting system is solved using a Newton-Raphson iteration. Doing so, KADATH is able to deal with strongly non-linear situations. The algorithms are validated by applying the library to four different problems of contemporary physics, in the fields of gauge field theory and general relativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-Spectral Analysis Methods for Spent Fuel Assay Using Lead Slowing-Down Spectroscopy of Spent Fuel

Nondestructive techniques for measuring the mass of fissile isotopes in spent nuclear fuel is a considerable challenge in the safeguarding of nuclear fuel cycles. A nondestructive assay technology that could provide direct measurement of fissile mass, particularly for the plutonium (Pu) isotopes, and improve upon the uncertainty of today’s confirmatory methods is needed. Lead slowing-down spectroscopy (LSDS) has been studied for the spent fuel application previously, but the nonlinear effects of assembly self shielding (of the interrogating neutron population) have led to discouraging assay accuracy for realistic pressurized water reactor fuels. In this paper, we describe the development of time-spectral analysis algorithms for LSDS intended to overcome these self-shielding effects. The algorithm incorporates the tabulated energy-dependent cross sections from key fissile and absorbing isotopes, but leaves their mass as free variables. Multi-parameter regression analysis is then used to directly calculate not only the mass of fissile isotopes in the fuel assembly (e.g., Pu-239, U-235, and Pu-241), but also the mass of key absorbing isotopes such as Pu-240 and U-238. Modeling-based assay results using a first-order self-shielding relationship indicate that LSDS has the potential to directly measure fissile isotopes with less than 5% average relative error, over a wide fuel burnup range. Shortcomings in the first-order self-shielding model and methods to improve the formulation are described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical Simulation of Isothermal Flow Across Slant Five-Tube Bundle with Spectral Element Method Code Nek5000

The helical coil steam generator (HCSG) is a specific type of shell-and-tube heat exchanger known for having a higher heat transfer coefficient than many other designs. For this reason, they are considered in small modular reactor and high temperature reactor designs. Investigation of flow behavior in HCSGs is important for better design. In this paper we present our study for modeling the coolant flow in the primary side of the HCSG. We used Nek5000, an open source, high-order spectral element computational fluid dynamics code developed in Argonne National Laboratory. Nek5000 accepts only hexahedral mesh, which makes the meshing process for the complicated HCSG geometry very challenging. A tetrahedral-to-hexahedral meshing strategy was applied to bypass the geometric complexities. In this study large eddy simulation (LES) was performed at the Reynolds number of 9000 based on the inlet velocity and the tube diameter. The employed subgrid-scale model for LES relies on explicit filtering. First- and second-order statistics were compared to available experimental data. We report overall velocity and turbulent kinetic energy showed good agreement with particle image velocimetry data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spectral encoding method for measuring the relative arrival time between x-ray/optical pulses

The advent of few femtosecond x-ray light sources brings promise of x-ray/optical pump-probe experiments that can measure chemical and structural changes in the 10–100 fs time regime. Widely distributed timing systems used at x-ray Free-Electron Laser facilities are typically limited to above 50 fs fwhm jitter in active x-ray/optical synchronization. The approach of single-shot timing measurements is used to sort results in the event processing stage. This has seen wide use to accommodate the insufficient precision of active stabilization schemes. In this article, we review the current technique for “measure-and-sort” at the Linac Coherent Light Source at the SLAC National Accelerator Laboratory. The relative arrival time between an x-ray pulse and an optical pulse is measured near the experimental interaction region as a spectrally encoded cross-correlation signal. The cross-correlation provides a time-stamp for filter-and-sort algorithms used for real-time sorting. Sub-10 fs rms resolution is common in this technique, placing timing precision at the same scale as the duration of the shortest achievable x-ray pulses.

43 PARTICLE ACCELERATORS↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ spectral calibration method for the impurity influx monitor (divertor) for ITER using angled physical contact fibers

The in situ calibration method for the impurity influx monitor (divertor) is experimentally examined. The total reflectance of the optical path from the focal point of the Cassegrain telescope to the first mirror is derived using a micro retroreflector array. An optical fiber with angled physical contact (APC) connectors reduces the return edge reflection. APC fibers and a multimode coupler increase the signal-to-noise ratio by about one order compared to that of triple-branched fibers and enable measurement of the wavelength dependence of the total reflectance of the optical system even after potential deterioration of mirror surfaces reduces reflectance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗