Portable Optical Particle Spectrometer aboard an Airborne Platform (POPS_AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility portable optical particle spectrometer (POPS) is a lightweight particle spectrometer designed for aerosol particle size distribution measurement. Several POPS of different versions have been procured to serve as routine instruments for the ARM Aerial Facility (AAF) unmanned aerial systems (UAS) and tethered balloon system (TBS) deployment since 2018. POPS measures the aerosol particle size distribution approximately between 0.13 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

Systematic Study of Spectrometer-Induced Azimuthal Asymmetries for SpinQuest

SpinQuest is a transversely polarized Drell-Yan experiment at Fermilab that will measure the Sivers asymmetry for the light antiquarks in the nucleon, using polarized NH3 and ND3 targets and the SeaQuest (E906) spectrometer. Measuring a non-zero Sivers asymmetry would provide strong evidence for non-zero sea-quark orbital angular momentum. Due to the time-dependence of the spectrometer efficiency, and the fluctuations of the beam luminosity, a false azimuthal asymmetry can be introduced that could masquerade as a Sivers asymmetry. In this study, a systematic study of false azimuthal asymmetries using SeaQuest data is presented. This work is supported by the US Department of Energy, Office of Science, Medium Energy Nuclear Physics Program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ice Nucleation Spectrometer (INS) Instrument Handbook

The Ice Nucleation Spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice nucleating particle (INP) number concentrations. It is almost identical to the CSU Ice Spectrometer (IS) design. While basic immersion freezing methods have been applied for decades, recent intercomparison studies (DeMott et al. 2017, 2018b) with other methods for sampling ambient INPs support the method’s utility. Use of the INS with filters produces spectra spanning wide dynamic ranges of temperature and, hence, INP concentration (e.g., six orders of magnitude). The INS is supported with well-established experimental protocols and has been applied in many diverse scenarios.

54 ENVIRONMENTAL SCIENCES↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CERBERUS: A Multi-Purpose Spectrometer and Alignment Station at SNS

In order to maximally utilize the existing beam ports at the Spallation Neutron Source, development and installation of a new neutron instrument is proposed at beam port 16a within building 8700 at Oakridge National Laboratory. Said instrument will provide nominally equal neutron beam access for three main science purposes; (1) as an alignment station for proposed single-crystal spectrometer samples to be run across the facility, (2) as a Near-Infrared (>100meV) filter analyzer spectrometer, nearly identical to that which was previously housed at the Lujan Center in Los Alamos, and (3) as a high-throughput nuclear cross-section measurement station. These three experimental applications would require no substantial technical developments, are complimentary in their technical requirements, and provide a worth-while capability that is infinitely beyond the current use of the 16a beam port at the First Target Station within the SNS complex. All three methods would enhance the facility’s science contributions, while accommodating two niche experiment methods that may not be strong enough to stand on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPCAPE – Proton Transfer Reaction Mass Spectrometer Field Campaign Report

The Eastern Pacific Cloud Aerosol Precipitation Experiment – Proton Transfer Reaction Mass Spectrometer (EPCAPE-PTRMS) campaign was created in response to the urgent need expressed by EPCAPE co-investigators for measurements of volatile organic compounds (VOCs) during the EPCAPE intensive operational period. A proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS, model 8000, Ionicon Analytik) was deployed to Mt. Soledad, San Diego, California, on 15 May 2023 for the measurement of VOCs. The instrument was installed in the same Atmospheric Radiation Measurement (ARM) user facility guest container that the Smith group used for the EPCAPE – Ultrafine Particle Properties (EPCAPE-UPP) campaign. The Smith group provided the sample inlet and operated and maintained the instrument. A complete VOC mass spectrum was recorded every 10 sec, continuously. Calibrations using a traceable VOC mixture were performed onsite at the end of the campaign.

54 ENVIRONMENTAL SCIENCES↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗

A Synthetic Pathway for Producing Carbon Dots for Detecting Iron Ions Using a Fiber Optic Spectrometer

Iron detection is of growing importance in the critical minerals sector, where unwanted iron ions are typically removed during the processing of target critical metals. The ideal sensor should utilize inexpensive, scalable materials along with a low-cost, robust, and easy-to-use analysis platform. Here, we demonstrate a simple acid–base synthesis of luminescent iron-responsive carbon dots by reacting ethanolamine, phosphoric acid, and m-phenylenediamine. The carbon dots exhibit selective, iron-specific emission quenching, with the ability to detect part-per-billion levels of iron ions even in 0.1 M HCl. After benchmarking the purified materials using a commercial spectrometer, a “low-cost” process is demonstrated in which carbon dots with minimal purification are coupled with a portable fiber-optic spectrometer for analyzing iron content. Carbon dot-coated paper strips are also evaluated as another convenient platform for iron analysis. Taken together, the sensing material and platforms demonstrated here are well-suited for detecting trace quantities of iron in environmentally relevant conditions, with potential applications in tracking iron removal processes during critical mineral production as one exciting area of interest.

acid mine draining↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

Undersizing of aged African biomass burning aerosol by an ultra-high-sensitivity aerosol spectrometer

The ultra-high-sensitivity aerosol spectrometer (UHSAS) differs from most other optical particle spectrometers by using a high-power infrared (IR) laser to detect small particles and reduce the sizing ambiguity due to the non-monotonicity of scattering with particle size. During the NASA ORACLES project (ObseRvations of Aerosols above CLouds and their intEractionS) over the southeast Atlantic Ocean, the UHSAS clearly undersized particles in the biomass burning plume extending from southern Africa. Since the horizontal and vertical extent of the plume was vast, the NASA P-3B research aircraft often flew through a fairly uniform biomass burning plume for periods exceeding 30 min, sufficient time to explore the details of the UHSAS response by selecting single particle sizes with a differential mobility analyzer (DMA) and passing them to the UHSAS. This was essentially an in-flight calibration of the UHSAS using the particles of interest. Two modes of responses appeared. Most particles were undersized by moderate amounts, ranging from not at all for 70 nm aerosols to 15 % for 280 nm particles. Mie scattering calculations show that composition-dependent refractive index of the particles cannot explain the pattern. Heating of brown carbon or tarballs in the beam causing evaporation and shrinking of the particles is the most plausible explanation, though mis-sizing due to non-sphericity cannot be ruled out. A small fraction (10 %–30 %) of the particles were undersized by 25 % to 35 %. Those were apparently the particles containing refractory black carbon. Laboratory calibrations confirm that black carbon is drastically undersized by the UHSAS, because particles heat to their vaporization point and shrink. A simple empirical correction equation was implemented that dramatically improves agreement with DMA distributions between 100 and 500 nm. It raised the median particle diameter by 18 nm, from 163 to 181 nm, during the August 2017 deployment and by smaller amounts during deployments with less intense pollution. Calculated scattering from UHSAS size distributions increased by about 130 %, dramatically improving agreement with scattering measured by nephelometers. The correction is only valid in polluted instances; clean marine boundary layer and free troposphere aerosols behaved more like the calibration spheres. We were unable to directly test the correction between 500 and 1000 nm, though aerodynamic particle sizer (APS) data appear to show that the correction is poor at the largest diameters, which is no surprise as the composition of those particles is likely to be quite different than that of the accumulation mode. This adds to the evidence that UHSAS data must be treated cautiously whenever the aerosol may absorb infrared light. Similar corrections may be required whenever brown carbon aerosol is present.

54 ENVIRONMENTAL SCIENCES↗

Design of the ion-optics for the MRSt neutron spectrometer at the National Ignition Facility (NIF)

A new Magnetic Recoil Spectrometer (MRSt) is designed to provide time-resolved measurements of the energy spectrum of neutrons emanating from an inertial confinement fusion implosion at the National Ignition Facility. At present, time integrated parameters are being measured using the existing magnet recoil and neutron time-of-flight spectrometers. The capability of high energy resolution of 2 keV and the extension to high time resolution of about 20 ps are expected to improve our understanding of conditions required for successful fusion experiments. The layout, ion-optics, and specifications of the MRSt will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Design and performance of a multi-terahertz Fourier transform spectrometer for axion dark matter experiments

Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectrometer and methods for use

A spectrometer includes a crystal analyzer having a radius of curvature that defines a Rowland circle, a sample stage configured to support a sample such that the sample is offset from the Rowland circle, an x-ray source configured to emit unfocused x-rays toward the sample stage, and a position-sensitive detector that is tangent to the Rowland circle. A method performed via a spectrometer includes emitting, via an x-ray source, unfocused x-rays toward a sample that is mounted on a sample stage such that the sample is offset from the Rowland Circle, thereby causing the sample to emit x-rays that impinge on the crystal analyzer or transmit a portion of the unfocused x-rays to impinge on the crystal analyzer; scattering, via the crystal analyzer, the x-rays that impinge on the crystal analyzer; and detecting the scattered x-rays via a position-sensitive detector that is tangent to the Rowland circle.

Seidler, Gerald Todd↗

Compact folded metasurface spectrometer

Compact optical devices such as spectrometers are realized with metasurfaces within a dielectric medium confined by reflective surfaces. The metasurfaces control the phase profiles of the reflected electromagnetic waves within the device. In a compact spectrometer, the metasurfaces within the device separate the electromagnetic waves in different wavelengths. The metasurfaces are designed according to their phase profile by varying the size of the array of scatterers.

Faraji-Dana, MohammadSadegh↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced Radionuclide Gamma spectrOmeter-2 (ARGO-2) for Low-level Radionuclide Measurements

A low-level multidimensional gamma spectrometer was recently installed at Pacific Northwest National Laboratory, USA. The spectrometer utilizes a dual-detector design and advanced detection techniques, demonstrating superior detection efficiency/sensitivity. This work details integral components of the system, including the dual-detector design, its shielding, and cosmic veto panels for background reduction. Results from system’s operation in singles and coincidence mode are highlighted.