Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Statistical analysis of spatial distribution of pores in metal additive manufacturing

We report mechanical properties of additively manufactured parts are sensitive to the presence of pores form during the manufacturing process. The impact of pores on the mechanical performance has been investigated extensively with respect to different parameters, such as pore volume fraction, shape, and size. However, statistical investigations focusing on the relationships between the spatial distribution of pores and process parameters; and consequently, the performance of the manufactured parts are scattered and limited. Also, these sparse investigations usually suffer from an ambiguous definition of terminologies. For instance, the required criteria to consider a point pattern as complete spatial randomness (CSR) are generally not clarified. Moreover, no numerical formalism is yet developed to show how much the observed spatial results are statistically significant. To address these shortcomings, the statistical definition of CSR in a point pattern and the procedure to quantitatively determine the deviation of a pattern from CSR were discussed. The explained statistical approach was used to investigate the effect of scanning speed parameter on the spatial distribution of gas pores in laser powder bed fusion manufactured stainless steel parts. Furthermore, and to highlight the impact of the spatial distribution of pores on mechanical properties, fatigue performances of parts with clustered and randomly distributed pores were simulated by finite element analysis. It is shown that by reducing the scanning speed, the spatial distribution of gas pores deviated more from CSR, and correspondingly fatigue performance deteriorated.

36 MATERIALS SCIENCE↗

Multi-scale statistical analysis of coronal solar activity

Multi-filter images from the solar corona are used to obtain temperature maps that are analyzed using techniques based on proper orthogonal decomposition (POD) in order to extract dynamical and structural information at various scales. Exploring active regions before and after a solar flare and comparing them with quiet regions, we show that the multi-scale behavior presents distinct statistical properties for each case that can be used to characterize the level of activity in a region. Information about the nature of heat transport is also to be extracted from the analysis.

58 GEOSCIENCES↗

WE-DE-201-02: A Statistical Analysis Tool for Plan Quality Verification in HDR Brachytherapy Forward Planning for Cervix Cancer

Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginal mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.

60 APPLIED LIFE SCIENCES↗

Statistical analysis of the Nb 3 Sn strand production for the ITER toroidal field coils

The ITER toroidal field (TF) strand procurement initiated the largest Nb 3 Sn superconducting strand production hitherto. The industrial-scale production started in Japan in 2008 and finished in summer 2015. Six ITER partners (so-called Domestic Agencies, or DAs) are in charge of the procurement and involved eight different strand suppliers all over the world, of which four are using the bronze route (BR) process and four the internal-tin (IT) process. In total more than 500 tons have been produced including excess material covering losses during the conductor manufacturing process, in particular the cabling. The procurement is based on a functional specification where the main strand requirements like critical current, hysteresis losses, Cu ratio and residual resistance ratio are specified but not the strand production process or layout. We introduce the analysis on the data acquired during the quality control (QC) process that was carried out to ensure the same conductor performance requirements are met by the different strand suppliers regardless of strand design. The strand QC is based on 100% billet testing and on applying statistical process control (SPC) limits. Throughout the production, samples adjacent to the strand pieces tested by the suppliers are cross-checked ('verified') by their respective DAs reference labs. The level of verification was lowered from 100% at the beginning of the procurement progressively to approximately 25% during the final phase of production. Based on the complete dataset of the TF strand production, an analysis of the SPC limits of the critical strand parameters is made and the related process capability indices are calculated. In view of the large-scale production and costs, key manufacturing parameters such as billet yield, number of breakages and piece-length distribution are also discussed. Furthermore, the results are compared among all the strand suppliers, focusing on the difference between BR and IT processes. Following the completion of the largest Nb 3 Sn strand production, our experience gained from monitoring the execution of the QC activities and from auditing the results from the measurements is summarised for future superconducting strand material procurement activities.

Vostner, A.↗

Statistical Analysis of Hubble /WFC3 Transit Spectroscopy of Extrasolar Planets

Transmission spectroscopy provides a window to study exoplanetary atmospheres, but that window is fogged by clouds and hazes. Clouds and haze introduce a degeneracy between the strength of gaseous absorption features and planetary physical parameters such as abundances. One way to break that degeneracy is via statistical studies. We collect all published HST /WFC3 transit spectra for 1.1–1.65 μ m water vapor absorption and perform a statistical study on potential correlations between the water absorption feature and planetary parameters. We fit the observed spectra with a template calculated for each planet using the Exo-transmit code. We express the magnitude of the water absorption in scale heights, thereby removing the known dependence on temperature, surface gravity, and mean molecular weight. We find that the absorption in scale heights has a positive baseline correlation with planetary equilibrium temperature; our hypothesis is that decreasing cloud condensation with increasing temperature is responsible for this baseline slope. However, the observed sample is also intrinsically degenerate in the sense that equilibrium temperature correlates with planetary mass. We compile the distribution of absorption in scale heights, and we find that this distribution is closer to log-normal than Gaussian. However, we also find that the distribution of equilibrium temperatures for the observed planets is similarly log-normal. This indicates that the absorption values are affected by observational bias, whereby observers have not yet targeted a sufficient sample of the hottest planets.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE STATISTICAL ANALYSIS OF X-RAY POLARIZATION MEASUREMENTS

In many polarimetry applications, including observations in the X-ray band, the measurement of a polarization signal can be reduced to the detection and quantification of a deviation from uniformity of a distribution of measured angles of the form A + Bcos {sup 2}({phi} - {phi}{sub 0}) (0 < {phi} < {pi}). We explore the statistics of such polarization measurements using Monte Carlo simulations and {chi}{sup 2} fitting methods. We compare our results to those derived using the traditional probability density used to characterize polarization measurements and quantify how they deviate as the intrinsic modulation amplitude grows. We derive relations for the number of counts required to reach a given detection level (parameterized by {beta} the ''number of {sigma}'s'' of the measurement) appropriate for measuring the modulation amplitude a by itself (single interesting parameter case) or jointly with the position angle {phi} (two interesting parameters case). We show that for the former case, when the intrinsic amplitude is equal to the well-known minimum detectable polarization, (MDP) it is, on average, detected at the 3{sigma} level. For the latter case, when one requires a joint measurement at the same confidence level, then more counts are needed than what was required to achieve the MDP level. This additional factor is amplitude-dependent, but is Almost-Equal-To 2.2 for intrinsic amplitudes less than about 20%. It decreases slowly with amplitude and is Almost-Equal-To 1.8 when the amplitude is 50%. We find that the position angle uncertainty at 1{sigma} confidence is well described by the relation {sigma}{sub {phi}} = 28. Degree-Sign 5/{beta}.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining Inspection and Unattended Monitoring: Statistical Analysis of Timely Detection

Process monitoring traditionally relies on facility operator measurements. New concepts for future inspection regimes include inspectorate-owned systems that enable unattended monitoring (UM) of all declared material flow \cite{smith_potential}. If such systems can be established as viable alternatives, they may provide an important new capability: a true inspector's estimate of MUF that can achieve the efficiency and effectiveness goals outlined by the IAEA. A rigorous statistical framework for comparing traditional and new methodologies is needed to evaluate this potential and enable inspectorates to optimally balance UM and sampling in the context of timely detection and cost constraints. Recognizing that these are only two among a wide range of safeguards activities that support mass balance evaluation to detect missing material, this paper compares UM to traditional safeguards sampling in terms of detection probabilities as a function of time based on simplistic material loss scenarios, and shows how the detection probabilities can be rather easily combined. Using this approach can help enable tradeoff analysis and optimal resource allocation.

international safeguards↗

Statistical analysis of displacement damage in small devices from neutron and ion irradiation

Modern semiconductor devices, such as gate-all-around nanosheet field-effect transistors (GAA NS FETs), are smaller than displacement damage cascades from fission neutrons. In this regime, device failure may occur through low-probability single events, rather than by parametric degradation previously seen in larger devices. Here, we present a statistical model that predicts the probability of a damage event in a small device and the probability distribution of the magnitude, i.e., number of displacements within the device, from each event. The model is developed first for neutron irradiation and then for energetic ion irradiation. The model is consistent with results from recent experiments in which lithium-ion irradiation produced stepwise increases in subthreshold current in GAA NS FETs.

Wampler, W. R.↗

Challenges in Biomarker Discovery: Combining Expert Insights with Statistical Analysis of Complex Omics Data

The advent of high throughput technologies capable of comprehensive analysis of genes, transcripts, proteins and other significant biological molecules has provided an unprecedented opportunity for the identification of molecular markers of disease processes. However, it has simultaneously complicated the problem of extracting meaningful signatures of biological processes from these complex datasets. The process of biomarker discovery and characterization provides opportunities both for purely statistical and expert knowledge-based approaches and would benefit from improved integration of the two. Areas covered In this review we will present examples of current practices for biomarker discovery from complex omic datasets and the challenges that have been encountered. We will then present a high-level review of data-driven (statistical) and knowledge-based methods applied to biomarker discovery, highlighting some current efforts to combine the two distinct approaches. Expert opinion Effective, reproducible and objective tools for combining data-driven and knowledge-based approaches to biomarker discovery and characterization are key to future success in the biomarker field. We will describe our recommendations of possible approaches to this problem including metrics for the evaluation of biomarkers.

bioinformatics↗

Statistical Analysis of Fermilab’s Safety Data

In the past ten months, since the Safety and Security pauses of May 31$^{st}$ and June 29$^{th}$ of 2023, there has been an increase in the number of Total Recordable Counts to the point that there are already more incidents in ten months that at any given year in the past decade. The purpose of this study is to try to determine if this increase could be explained as a statistical fluctuation. We will show that it is very unlikely (essentially 4$\sigma$ unlikely) that the increase is a fluctuation, and therefore there must be a cause. The Safety and Security pauses of the past May and June, and many events thereafter, have been impactful events at Fermilab, so we should feel an obligation to assess their benefit, or detriment, to the safety of our people.

99 GENERAL AND MISCELLANEOUS↗

Statistical analysis on random quantum circuit sampling by Sycamore and Zuchongzhi quantum processors

Random quantum circuit sampling, a task to sample bit strings from a random quantum circuit, is considered a suitable benchmark task to demonstrate the outperformance of quantum computers even with noisy qubits. Recently, random quantum circuit sampling was performed on the Sycamore quantum processor with 53 qubits [Nature (London) 574, 505 (2019)] and on the Zuchongzhi quantum processor with 56 qubits [Phys. Rev. Lett. 127, 180501 (2021)]. Here, we analyze and compare the statistical properties of the outputs of the random quantum circuit sampling by the Sycamore and Zuchongzhi processors. Using the Marchenko-Pastur law of random matrices of bit strings and the Wasssertein distances between bit strings, we find that the statistical properties of Sycamore bit strings are quite different from those of Zuchongzhi bit strings, while both processors score similar values of linear cross-entropy fidelity for random circuit sampling. Some bit strings sampled by the Zuchongzhi processor pass the NIST random number tests while both Sycamore and Zuchongzhi processors show similar patterns in the heat maps of bit strings. Zuchongzhi bit strings are much closer to classical uniform random bits than those of Sycamore. It is shown that the statistical properties of bit strings of both random quantum circuits change little as the depth of the random quantum circuits increases. Our findings raise a question about the computational reliability of noisy quantum processors because two quantum processors with similar noise levels and similar qubit structures produced statistically different outputs for the same random quantum circuit sampling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Characterization and differentiation of aluminum powders used in improvised explosive devices. Part 2: Micromorphometric method refinement and preliminary statistical analysis

Abstract Aluminum (Al) powder is commonly encountered in improvised explosive devices (IEDs) as a metallic fuel due to its availability and low cost. Although available commercially in powder form, amateur bomb‐makers also produce their own Al powder via simple methods found online. In order to provide investigative leads and forensic intelligence, it is important to evaluate not only the composition of homemade devices, but also to distinguish between the various forms of Al powder they contain. To achieve this goal, a method using automated microscopy in combination with statistical techniques has been demonstrated to have the potential to provide source discrimination and investigative leads in source attribution of Al powders in IEDs. The present research refined this method and investigated 59 industrially and amateurly produced Al powder sources with seven subsamples per source using two traditional linear discriminant analyses (LDA), one with a standard data split for training and testing, and another using leave‐one‐out cross‐validation. Averaging the classification accuracies for the two LDA‐based analyses, LDA has the ability to correctly classify 59.26%, 83.35%, and 80.69% of the samples based on their powder source, type, and production method, respectively. This classification accuracy represents a 3407%, 317%, and 61.38% increase in accuracy from random class assignment, respectively. Further, in most instances of incorrect data attribution to a particular source, the subsample has been misidentified with another sample of the same powder type or production method.

Ommen, Danica M.↗

Statistical Analysis of the Phase 3 Emissions Data Collected in the EPAct/V2/E89 Program: January 7, 2010 - July 6, 2012

Phase 3 of the EPAct/V2/E-89 Program investigated the effects of 27 program fuels and 15 program vehicles on exhaust emissions and fuel economy. All vehicles were tested over the California Unified Driving Cycle (LA-92) at 75 degrees F. The program fuels differed on T50, T90, ethanol, Reid vapor pressure, and aromatics. The vehicles tested were new, low-mileage 2008 model year Tier 2 vehicles. A total of 956 test runs were made. Comprehensive statistical modeling and analyses were conducted on methane, carbon dioxide, carbon monoxide, fuel economy, non-methane hydrocarbons, non-methane organic gases, oxides of nitrogen, particulate matter, and total hydrocarbons. In general, model fits determined that emissions and fuel economy were complicated by functions of the five fuel parameters. An extensive evaluation of alternative model fits produced a number of competing model fits. Many of these alternative fits produce similar estimates of mean emissions for the 27 program fuels but should be carefully evaluated for use with emerging fuels with combinations of fuel parameters not included here. The program includes detailed databases on each of the 27 program fuels on each of the 15 vehicles and on each of the vehicles on each of the program fuels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic imaging and statistical analysis of the metamagnetic phase transition of FeRh with electron spins in diamond

Magnetic imaging based on nitrogen-vacancy (NV) centers in diamond has emerged as a powerful tool for probing magnetic phenomena in fields ranging from biology to physics. A key strength of NV sensing is its local-probe nature, enabling high-resolution spatial images of magnetic stray fields emanating from a sample. However, this local character can also form a drawback for analyzing the global properties of a system, such as a phase transition temperature. Here, we address this challenge by using statistical analyses of magnetic-field maps to characterize the first-order temperature-driven metamagnetic phase transition from the antiferromagnetic to the ferromagnetic state in FeRh. After imaging the phase transition and identifying the regimes of nucleation, growth, and coalescence of ferromagnetic domains, we statistically characterize the spatial magnetic-field maps to extract the transition temperature and thermal hysteresis width. By analyzing the spatial correlations of the maps in relation to the magnetocrystalline anisotropy and external magnetic field, we detect a reorientation of domain walls across the phase transition. The employed statistical approach can be extended to the study of other magnetic phenomena with NV magnetometry or other sensing techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than {+-}10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was unaffected (within 10%) for perfusion periods of less than 150 s or treatment times of 20 min or greater. Treatment over six fractions improved the EUD per fraction such that all parametric combinations resulted in unaffected EUD. The stochastic models confirmed these results. Conclusions: Dose heterogeneity in circulating blood cells is clinically acceptable for typical treatment times, perfusion rates, and cell types. Development of conformal, sequential TBI treatment techniques should not be withheld based on concerns over circulating blood dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

STATISTICAL ANALYSIS OF FLARING LOOPS OBSERVED BY NOBEYAMA RADIOHELIOGRAPH. I. COMPARISON OF LOOPTOP AND FOOTPOINTS

Twenty-four events with looplike structures at 17 and 34 GHz are selected from the flare list of Nobeyama Radioheliograph. We obtained the brightness temperatures at 17 and 34 GHz, the polarization degrees at 17 GHz, and the power-law spectral indices at the radio peak time for one looptop (LT) and two footpoints (FPs) of each event. We also calculated the magnetic field strengths and the column depths of nonthermal electrons in the LT and FPs of each event, using the equations modified from the gyrosynchrotron equations by Dulk. The main statistical results from those data are summarized as follows. (1) The spectral indices, the brightness temperatures at 17 and 34 GHz, the polarization degrees at 17 GHz, the calculated magnetic field strengths, and the calculated column densities of nonthermal electrons are always positively correlated between the LT and the two FPs of the selected events. (2) About one-half of the events have the brightest LT at 17 and 34 GHz. (3) The spectral indices in the two FPs are larger (softer) than those in the corresponding LT in most events. (4) The calculated magnetic field strengths in the two FPs are always larger than those in the corresponding LT. (5) Most of the events have the same positive or negative polarization sense in the LT and the two FPs. (6) The brightness temperatures at 17 and 34 GHz in each of the LT and the two FPs statistically decrease with their spectral indices and the calculated magnetic field strengths, but increase with their calculated column densities of nonthermal electrons. Moreover, we try to discuss the possible causes of the present statistical results.

99 GENERAL AND MISCELLANEOUS↗