Search NASA⌕ Search

SEARCH · Search NASA

Results for “Steam cycling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Energy and cost saving results for advanced technology systems from the Cogeneration Technology Alternatives Study (CTAS)

An overview of the organization and methodology of the Cogeneration Technology Alternatives Study is presented. The objectives of the study were to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the future and to assess the advantages of advanced technology systems compared to those systems commercially available today. Advanced systems studied include steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics. Steam turbines, open cycle gas turbines, combined cycles, and diesel engines were also analyzed in versions typical of today's commercially available technology to provide a base against which to measure the advanced systems. Cogeneration applications in the major energy consuming manufacturing industries were considered. Results of the study in terms of plant level energy savings, annual energy cost savings and economic attractiveness are presented for the various energy conversion systems considered.

Sagerman, G. D.↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Environmental barrier coatings on SiC without a silicon bond coating: oxidation resistance, failure modes, and future improvements

Environmental barrier coatings (EBCs) are used to mitigate chemical reactions between SiC ceramic matrix composite (CMC) components and the H 2 O in combustion gas in turbine hot sections. CMCs are currently temperature-limited by the Si-bond coating, which melts at ~ 1414 °C. This work explores EBCs where the bond coating was removed to achieve higher operating temperatures. Various versions of enhanced roughness SiC were utilized to improve EBC adhesion to the substrates prior to 1 h furnace cycle testing in steam at 1250–1425 °C. The enhanced SiC roughness resulted in short coating lifetimes as the roughness was oxidized away with SiO 2 formation. Further, isothermal furnace exposures at 1400–1600 °C showed Yb 2 Si 2 O 7 /Yb 2 SiO 5 EBC microstructural changes, resulting in premature debonding from the substrates. Finally, this work provides baseline requirements for the development of both next-generation EBCs and bond coating strategies to overcome the current limitation of the Si-bond coating melting temperature.

36 MATERIALS SCIENCE↗

A statistical representation of bond coating oxidation under environmental barrier coatings

Environmental barrier coatings (EBCs) protect SiC-based ceramic matrix composites (CMCs) in turbine hot sections from high-temperature volatilization in combustion gases. The formation of a SiO 2 thermally grown oxide (TGO) is expected under the EBC after long-term operation. The oxidation resistance of the EBC is understood as a life-limiting factor for the CMC, and this work predicts long-term oxidation behavior under EBCs through a simple statistical approach. Specimens were exposed to 1350°C isothermal conditions for 100-h thermal cycles in flowing steam for up to 1000 h. The EBC morphology, SiO 2 thickness, and SiO 2 cracking behavior were assessed. Using thousands of SiO 2 thickness measurements across many millimeters of the interface, a realistic representation of the entire TGO was captured via a lognormal distribution. The lognormal fit parameters were extrapolated out to 25 000 h to assess the degree of SiO 2 growth, the spread of SiO 2 thicknesses related to the rough oxidizing interface, and percentages of the intermediate bond coating consumed. In conclusion, local interfacial defects from the coating deposition process are identified as local failure points for EBC—CMC systems.

SiO 2↗

Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 6: Closed-cycle gas turbine systems

Both recuperated and bottomed closed cycle gas turbine systems in electric power plants were studied. All systems used a pressurizing gas turbine coupled with a pressurized furnace to heat the helium for the closed cycle gas turbine. Steam and organic vapors are used as Rankine bottoming fluids. Although plant efficiencies of over 40% are calculated for some plants, the resultant cost of electricity was found to be 8.75 mills/MJ (31.5 mills/kWh). These plants do not appear practical for coal or oil fired plants.

Amos, D. J.↗

Comparative assessment of orbital and terrestrial central power plants

Recent studies of the space power system (SPS) are integrated into a total social cost framework developed for terrestrial central electric power systems. Total social costs include the projection of commercial economics to the time frame of interest as well as the federal research, development and demonstration (RD&D) costs, the health impacts, the resources required, the environmental impacts and other social costs. The SPS system is limited to transporting all materials from the earth's surface to geosynchronous orbit. Only silicon photovoltaic is considered as the SPS energy conversion technique. Costs and impacts of the LWR are considered as a reference for nuclear systems, and the low BTU coal gasification with combined cycle gas and steam turbines is considered as a reference for a fossil central electric plant. The ground solar systems considered are solar thermal using the central receiver approach with thermal storage, and solar photovoltaic using the silicon cell with battery storage.

Caputo, R.↗

Benefits of advanced technology in industrial cogeneration

This broad study is aimed at identifying the most attractive advanced energy conversion systems for industrial cogeneration for the 1985 to 2000 time period and assessing the advantages of advanced technology systems compared to using today's commercially available technology. Energy conversion systems being studied include those using steam turbines, open cycle gas turbines, combined cycles, diesel engines, Stirling engines, closed cycle gas turbines, phosphoric acid and molten carbonate fuel cells and thermionics. Specific cases using today's commercially available technology are being included to serve as a baseline for assessing the advantages of advanced technology.

Barna, G. J.↗

Comparative evaluation of three alternative power cycles for waste heat recovery from the exhaust of adiabatic diesel engines

Three alternative power cycles were compared in application as an exhaust-gas heat-recovery system for use with advanced adiabatic diesel engines. The power cycle alternatives considered were steam Rankine, organic Rankine with RC-1 as the working fluid, and variations of an air Brayton cycle. The comparison was made in terms of fuel economy and economic payback potential for heavy-duty trucks operating in line-haul service. The results indicate that, in terms of engine rated specific fuel consumption, a diesel/alternative-power-cycle engine offers a significant improvement over the turbocompound diesel used as the baseline for comparison. The maximum imporvement resulted from the use of a Rankine cycle heat-recovery system in series with turbocompounding. The air Brayton cycle alternatives studied, which included both simple-cycle and compression-intercooled configurations, were less effective and provided about half the fuel consumption improvement of the Rankine cycle alternatives under the same conditions. Capital and maintenance cost estimates were also developed for each of the heat-recovery power cycle systems. These costs were integrated with the fuel savings to identify the time required for net annual savings to pay back the initial capital investment. The sensitivity of capital payback time to arbitrary increases in fuel price, not accompanied by corresponding hardware cost inflation, was also examined. The results indicate that a fuel price increase is required for the alternative power cycles to pay back capital within an acceptable time period.

Bailey, M. M.↗

Brush Seals for Improved Steam Turbine Performance

GE Energy has retrofitted brush seals into more than 19 operating steam turbines. Brush seals offer superior leakage control compared to labyrinth seals, owing to their compliant nature and ability to maintain very tight clearances to the rotating shaft. Seal designs have been established for steam turbines ranging in size from 12 MW to over 1200 MW, including fossil, nuclear, combined-cycle and industrial applications. Steam turbines present unique design challenges that must be addressed to ensure that the potential performance benefits of brush seals are realized. Brush seals can have important effects on the overall turbine system that must be taken into account to assure reliable operation. Subscale rig tests are instrumental to understanding seal behavior under simulated steam-turbine operating conditions, prior to installing brush seals in the field. This presentation discusses the technical challenges of designing brush seals for steam turbines; subscale testing; performance benefits of brush seals; overall system effects; and field applications.

Turnquist, Norman↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗

Advanced Ultra-Supercritical Component Test (ComTest) Project for 760*C Steam Conditions

ComTest is a $27M Department of Energy-funded project. Phase I, which began in November 2015, served to identify the technology gaps, as well as the scope and cost of required testing. Phase II, which was awarded in December 2018, includes an advanced manufacturing effort to complete U.S. based supply chain development for full commercial scale (800-850 MWe) AUSC components made of nickel-based alloys, components operating at up to 760°C. Completion of Phase II scheduled for September 30, 2021. Strategic Objectives of U.S. AUSC Project include: Power Plant Efficiency Improvements –Develop cost-effective, reliable technologies to improve the efficiency of new and existing high-temperature advanced generation power plants. Close gaps to achieve readiness for commercial scale demonstration of Advanced Ultra-Supercritical (AUSC) technology. Fabricate full-scale versions of key nickel-based alloy components. Validate capabilities of US supply chain for cost certainty. Support cross-cutting high-temperature generation technologies. Obtain ASME Code approval for new materials, components and processes. Increase power plant steam temperatures for higher cycle efficiency (Note: Average efficiency of US coal-fired fleet = 33% HHV; A-USC plant efficiency over 47% HHV at 1,400°F (760°C) steam temperature).

fireside corrosion↗

Thermionic topping of electric power plants

The most likely use of thermionic conversion is in the form of a topping cycle combined with a steam-turbogenerator plant. A specific reference system is chosen in which the thermionic topping cycle occurs in thermionic heat exchangers referred to as large, modular thermionic units to which heat is transferred from a separate heat source and which reject their heat to a conventional steam turboelectric system. Results of analysis show that the performance and cost criteria for practical thermionic topping of large electric power plants are well within the reach of demonstrated and foreseeable converter capabilities. Thermionic topping has many significant advantages over unconventional cycles proposed for topping applications, including level of demonstrated and projected performance and lifetime, development time, and design simplicity.

Britt, E. J.↗

Intra-catalyst CH 4 oxidation pathways on a Pd/Al 2 O 3 /CeZrO x -based commercial catalyst and implications on NO x conversion profiles for a natural gas vehicle exhaust under lambda modulation

The performance of a three-way catalyst (TWC) in natural gas-powered vehicles is enhanced by periodic changes in air-to-fuel ratio (λ-modulation). The reaction networks and sequences inside the catalyst that facilitate such enhanced performance have not been extensively investigated. Here, this work applied intra-catalyst measurements (SpaciMS) to analyze the transient spatiotemporal gas concentrations inside a Pd-based TWC to establish relationships between CH 4 , NO x , CO and H 2 conversion pathways. Steam reforming and partial oxidation were revealed to be the main CH 4 conversion routes. The cyclic rich-lean conditions combined with the oxygen storage capacity (OSC) of the TWC generate reduced and oxidized zones that are constantly moving within the catalyst, changing the dominant chemical reactions occurring on the surface. In the reduced zones, OSC is depleted while CH 4 is converted through steam reforming and NO x is converted through reactions with H 2 , CO, and other surface-bound reducing fragments formed by CH 4 conversion. In the oxidized zones, OSC is replenished, CH 4 is converted by partial oxidation, and H 2 , CO, and NH 3 are oxidized. The length of lean-rich phases impacts the catalyst performance significantly; too short or too long of a rich or lean phase can lower the overall conversion of reactive species. An inhibition of CH 4 conversion was observed during the rich phase possibly due to CO-poisoning of active sites. The intra-catalyst measurements revealed that the catalyst consists of three distinct reaction zones and their lengths vary with modulation conditions. Various modulation frequencies, amplitudes, λ-centers, and temperatures were investigated which allowed an understanding of how these parameters affect the reaction zones and catalyst utilization. Understandings from this work can enable adaptive λ-control strategies to optimize the overall TWC performance over a range of vehicle operating conditions.

Lean-Rich cycling↗

Performance and Cost Potential of sCO2 Bottoming Cycle for Gas Turbines with Carbon Capture – Paper 32

This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine-based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for the generation of steam required for a solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles are similar to those of a state-of-the-art triple-pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle with ~0.7 percentage point higher plant efficiency and 1.4% lower LCOE.

Pidaparti, Sandeep↗

Chemical looping air separation with Sr 0.8 Ca0.2Fe 0.9 Co 0.1 O 3-δ perovskite sorbent: Packed bed modeling, verification, and optimization

Chemical looping air separation (CLAS) represents a promising approach for efficient O 2 production from the air. This present study aims at optimizing the absorber/desorber operations and the separation process with extensive experimental validation. Specifically, a one-dimensional packed bed model was developed to investigate the CLAS operation with a Sr 0.8 Ca 0.2 Fe 0.9 Co 0.1 O 3-δ perovskite sorbent. The redox thermodynamics of perovskite sorbent was measured by TGA and then incorporated into a linear driving force model to describe the O 2 absorption and desorption rates. Both 4-step and 5-step air separation cycle configurations, with various cyclic structures, were performed in a subpilot-scale packed bed. The model predicted O2 purity and productivity were consistent with experimental results, supporting its accuracy and applicability. Parametric analysis and multi-objective optimization were further carried out to assess the performance of CLAS. Both O 2 purity and recovery increased monotonically with the cycle time, airflow rate, steam flow rate, and absorption pressure. Meanwhile, optimal O 2 productivity and power consumption can only be achieved by specific combinations of these parameters. The optimized results showed that CLAS can be highly competitive when compared to conventional pressure swing adsorption (PSA) or cryogenic distillation. The 5-step cycle configuration achieved a minimum power consumption of 118 kW·h for producing 1 ton O 2 with ≥ 95% purity. The maximum O 2 productivity reached 0.0932 g O2 /(g sorbent ·h) with 390 kW·h/ton O 2 of energy consumption (95% pure). The optimization results also indicate that CLAS can potentially be more efficient than cryogenic distillation even when the required O 2 purity is above 99%.

42 ENGINEERING↗