Engineering-Scale Batch Purification of Ternary MgCl 2 -KCl-NaCl Salt Using Thermal and Magnesium Contact Treatment

High-temperature molten chloride salts are a desirable heat transfer and energy storage media. The NaCl-KCl-MgCl 2 is of particular interest because of its low melting point and relatively inexpensive constituents. Moisture and hydroxides must be removed from the salt to control corrosion at high temperatures. Previous studies have developed and demonstrated various techniques for bench-scale salt purifications. This paper details the system, process, and insight gained in the purification of a 200 kg scale batch of NaCl-KCl-MgCl 2 salt at Oak Ridge National Laboratory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from a medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

Process Improvement For Pu-238 Production at Idaho National Laboratory

Idaho National Laboratory (INL) has supported the production of Pu-238 for future NASA deep space missions since 2017. Over this time, INL has worked to improve the qualification process of Pu-238 production targets as well as improve processes related to the shipping, storage, irradiation, and storage of Pu-238 production targets. Qualification of Pu-238 production targets began with flux measurements and scoping analysis to provide fundamental data to confirm the impacts on the operation of the Advanced Test Reactor (ATR), Fig1. Later, initial production targets were irradiated in ATR’s I-7 position, and then the South Flux Trap (SFT). A modified target design was then implemented which would use the full length of the ATR core and increase Pu-238 production. While working to improve and streamline the qualification of the Pu-238 production targets, INL worked to improve multiple operational aspects of the Pu-238 production process. These changes include updating procedures to streamline operations, supporting modification of shipping containers to contain five rather than one production target, reviewing target receipt procedures and changing work flow to provide flexibility in target receipt, and designing and fabricating support equipment for the storage and internal transfer of production targets

07 ISOTOPE AND RADIATION SOURCES↗

Process Improvements For Pu-238 Production at Idaho National Laboratory

Idaho National Laboratory (INL) has supported the production of Pu-238 for future NASA deep space missions since 2017. Over this time, INL has worked to improve the qualification process of Pu-238 production targets as well as improve processes related to the shipping, storage, irradiation, and storage of Pu-238 production targets. Qualification of Pu-238 production targets began with flux measurements and scoping analysis to provide fundamental data to confirm the impacts on the operation of the Advanced Test Reactor (ATR), Fig1. Later, initial production targets were irradiated in ATR’s I-7 position, and then the South Flux Trap (SFT). A modified target design was then implemented which would use the full length of the ATR core and increase Pu-238 production. While working to improve and streamline the qualification of the Pu-238 production targets, INL worked to improve multiple operational aspects of the Pu-238 production process. These changes include updating procedures to streamline operations, supporting modification of shipping containers to contain five rather than one production target, reviewing target receipt procedures and changing work flow to provide flexibility in target receipt, and designing and fabricating support equipment for the storage and internal transfer of production targets.

07 ISOTOPE AND RADIATION SOURCES↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

Synergistic heat pumped thermal storage and flexible carbon capture system

A power plant system is disclosed. The power plant system includes a combustor configured, a turbine configured to generate electricity, a heat exchanger and a steam turbine, a carbon capture system configured to remove at least a portion of carbon-based gasses from the flue gas downstream from the heat recovery steam generator, and a thermal storage system including a hot storage unit configured to store thermal energy at a hot temperature, the hot temperature greater than ambient temperature. The power plant is configured to operate in at least a first mode for storing thermal energy in the thermal storage system and a second mode for releasing the stored thermal energy from the thermal storage system and during the second mode, heat stored in the hot storage unit is transferred to the carbon capture system.

Bandhauer, Todd M.↗

Analysis of Radiological Release From Fueled Irradiation Experiments During Manual Handling (Slides)

Irradiation experiments are manually handled at the Advanced Test Reactor (ATR) by qualified operators using long handled tools. Standard handling evolutions include insertion and removal from the reactor vessel, transfer to/from a storage location or cask in the ATR canal, and handling/reconfigurations at a canal working tray. Such routine handling has the potential to result in mechanical damage to the experiment boundary which is credited to retain fission products. Since damage can occur due to operator error, this is an anticipated occurrence. This work determines the radiological consequences to receptors inside the ATR facility, as well as public receptors. Given the wide variety of fuel types tested at the ATR, a generic approach to the analysis is taken. The radiological inventory is determined to bound a variety of fuel types (e.g., ceramic and molten fuel matrices) and fission powers on the U-235 enrichment spectrum. The source term analysis considers different release fractions to bound different fuel types and burnups. The postulated handling events occur underwater; thus, retention of the released isotopic content is considered within the canal water column. Retention of radionuclides in the water column is determined using a modified approach of United States (US) Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.183. Radiological dose to the facility receptor is determined using a compartment release model. Dose to the public receptor is determined using atmospheric dispersion models using site specific atmospheric conditions with the use of the Radiological Safety Analysis Computer (RSAC) program version 7.2.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Data Management in the Continuum: Cross-facility Object-based Data Transfers

Scientific workflows are evolving from relying on a monolithic storage subsystem at a single High-Performance Computing (HPC) facility to using geographically distributed file systems, repositories, and cloud storage. As a result, storing, accessing, transferring, and managing scientific data have become highly complex and prone to performance inefficiencies. This paper delves into these challenges by exploring an optimized end-to-end interface designed to seamlessly connect various local and remote storage systems, enabling efficient data movement of objects across HPC–Cloud and HPC–HPC environments. We showcase this capability through an object-focused data management runtime system, discuss the effects of relaxed consistency semantics in distributed object scenarios, and illustrate its application in an earthquake simulation workflow. Besides reducing the amount of data by selectively transferring regions of interest, our facility-local results achieved a speedup of 45 × over an optimized HDF5 usage and 15 × over the HDF5 with caching by using the new interface in PDC-XF.

Bez, Jean Luca↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Dual-function lignin monomers enable high-performance graphene electrodes via interface confinement and proton transfer enhancement

Graphene oxide (GO)-based energy storage faces dual bottlenecks: unsustainable reduction methods and sluggish proton transfer kinetics. Here, we introduce a groundbreaking green strategy using lignin-derived vanillyl alcohol (VA) as a dual-function monomer to simultaneously address these challenges. By thermally annealing GO/VA films at mild temperatures (<100 °C), VA triggers an interface-confined reduction of GO while self-polymerizing into redox-active oligomers (P-VA) that intercalate between graphene layers. This dual role-reducing agent and proton highway enables a 3D conductive network with minimized graphene restacking, abundant redox sites, and rapid H + transport pathways. Density Functional Theory (DFT) reveals how P-VA optimizes proton dynamics, while the resulting rGO-P-VA4-T90 electrode achieves a record volumetric capacitance of 311.1F/cm 3 (777.8F/cm 2 ) and retains 87.8 % capacity after 10,000 cycles. Flexible solid-state supercapacitors deliver 94.2 μWh/cm 2 energy density at 63.8 μW/cm 2 , rivaling state-of-the-art devices. Furthermore, this work redefines sustainable graphene engineering, merging biomass valorization with high-performance energy storage in a scalable, eco-friendly paradigm.

Graphene oxide reduction↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Elucidating the Transition of 3D Morphological Evolution of Binary Alloys in Molten Salts with Metal Ion Additives

Molten salts serve as effective high-temperature heat transfer fluids and thermal storage media used in a wide range of energy generation and storage facilities, including concentrated solar power plants, molten salt reactors and high-temperature batteries. However, at the salt–metal interfaces, a complex interplay of charge-transfer reactions involving various metal ions, generated either as fission products or through corrosion of structural materials, takes place. Simultaneously, there is a mass transport of ions or atoms within the molten salt and the parent alloys. The precise physical and chemical mechanisms leading to the diverse morphological changes in these materials remain unclear. Here, to address this knowledge gap, this work employed a combination of synchrotron X-ray nanotomography and electron microscopy to study the morphological and chemical evolution of Ni-20Cr in molten KCl-MgCl 2 , while considering the influence of metal ions (Ni 2+ , Ce 3+ , and Eu 3+ ) and variations in salt composition. Our research suggests that the interplay between interfacial diffusivity and reactivity determines the morphological evolution. The summary of the associated mass transport and reaction processes presented in this work is a step forward toward achieving a fundamental comprehension of the interactions between molten salts and alloys. Overall, the findings offer valuable insights for predicting the diverse chemical and structural alterations experienced by alloys in molten salt environments, thus aiding in the development of protective strategies for future applications involving molten salts.

36 - MATERIALS SCIENCE↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

A Novel Bi-directional AC/DC - DC/AC Wireless Power Transfer System for Grid Support Applications

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This paper presents a novel topology for providing export power applications. Proposed topology can be used for grid (primary)-side of bi-directional wireless power transfer (WPT) systems, mobile energy storage systems (ESSs), and electric vehicle (EV) batteries. The proposed concept here achieves energy transfer between sources by using a hybrid frequency bi-directional ac/dc converter without an additional front-end converter stage compared to the conventional systems. Due to inherent merit of the proposed bi-directional ac/dc converter, ac input with 60 Hz grid frequency can be directly transferred through the wireless coils and can be directly converted to the dc. Results demonstrate the performance and the functionality of the single-phase bi-directional system with the input / output of 110 V ac,rms and 200 V dc at 1 kW power. Full paper will demonstrate the converter operation at 10 kW power level with additional features and control aspects.

Asa, Erdem↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the Aerosol Source Term in Dry Storage Canisters

As long-term dry storage of used nuclear fuel at independent spent fuel storage installations (ISFSI) trends toward the de facto back end of the US fuel cycle, it becomes appropriate to investigate potential degradation and dispersion scenarios for suitable risk mitigation purposes. Pitting and subsequent stress corrosion cracking of the canister wall is currently viewed as a potential scenario leading to a through-wall pathway for contamination to be transferred from within the storage container to the surrounding environment. While stress corrosion cracking measurements are currently underway to further characterize this scenario, a parallel effort endeavors to perform a consequence analysis of conditions in which through wall cracks are indeed formed. This effort consists of engineering scale modeling using the GOTHIC and MELCOR software packages along with experimental depletion and penetration tests.