Chlorine Validation through Critical Integral Experiments

An increased interest in the validation of chlorine nuclear data, specifically 35Cl, in recent years has led to the prioritization of conducting chlorine critical experiments for nuclear data validation and criticality safety evaluations. A previous experiment was conducted with PVC and CPVC (chlorinated polyvinyl chloride) to reduce the margin of subcriticality for PF-4 operations with aqueous plutonium chloride solutions. Challenges in determining the composition of specific polymers, namely the CPVC, made it difficult to characterize, and therefore benchmark. Additional materials that were utilizable for chlorine validation were not immediately clear, as form, strength, purity, and composition are all important. A series of possible absorber materials were identified and studied, but ultimately granular sodium chloride was chosen. In addition to the needs of LANL’s PF-4 other industry collaborators have brought attention to the need for chlorine validation. Specifically, the need for HEU electrorefining with LiCl salts at Y-12 was taken into consideration for this experiment, with the experimental configurations being finely tuned to best meet their needs. Needs for validation were also presented by Idaho National Lab (INL) and TerraPower for validation of their Molten Chloride Reactor Experiment (MCRE) and Molten Chloride Fast Reactor (MCFR) and have also been considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Availability of Critical Benchmark Experiments for the Pebble Tanker Transportation Model for Nuclear Criticality Safety Validation of TRISO Pebbles

This study addresses the need for comprehensive investigations into TRi-structural ISOtropic (TRISO) fuel pebble transportation validation. In this work, an exploratory model, the pebble tanker(PT), was developed with the aim of facilitating the validation of nuclear criticality safety calculations in the context of industrial-scale transportation of TRISO fuel. The PT model was designed to investigate the availability and applicability of critical benchmark experiments crucial for assessing the transportation of these pebbles. This work incorporated sensitivity/uncertainty (S/U) similarity studies to quantify the applicability of critical benchmark experiments and to address nuclear data uncertainties in the context of TRISO transportation. Two container models were investigated: one for the Hermes-type pebble and one for the Pebble Bed Modular Reactor (PBMR)–type pebble. The models were simplified, considering fuel, containment, and either water or air, to enable a focus on the underlying physics of applications involving TRISO fuel pebbles using the PT model. A crucial aspect under consideration was the capacity of the transport package to hold pebbles while ensuring subcriticality in the flooded state. An approach in the criticality validation process involves assessing the similarity between systems through an integral index parameter evaluation. This involves calculating a correlation coefficient (referred to as c k ) based on shared nuclear data–induced uncertainty between a benchmark experiment and the application of the PT model. To facilitate this analysis, the SCALE tools, particularly the CSAS6-Shift, TSUNAMI-3D-Shift, and TSUNAMI-IP sequences, were employed for comprehensive studies in neutronics and S/U analysis. Our findings showed that there are sufficient critical experimental benchmarks to perform this validation of the PT model in the most reactive state, i.e. when the tanker is flooded. This paper provides valuable insights into validating a transport package for Generation IV TRISO fuel pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subcritical Noise Measurements with a Nickel-Reflected Plutonium Sphere

Subcritical measurements were conducted with an a-phase plutonium sphere reflected by nickel hemishells using the 252Cf Source-Driven Noise Analysis (CSDNA) method to provide criticality safety benchmark data. Measured configurations included a bare plutonium sphere as well as the plutonium sphere reflected by the following nickel thicknesses: 1.27, 2.54, 3.81, 5.08, and 7.62 cm. A certain ratio of spectral quantities was measured for each configuration which varies linearly with the keff of the system. In addition, two types of Monte Carlo calculations were employed: a modified version of MCNP to calculate the ratio of spectral quantities and a KCODE calculation. From the measured and computed quantities the multiplication of each configuration can be approximated. A comprehensive uncertainty analysis was then performed that includes uncertainties in the geometry and materials present in the system in addition to the uncertainties in the method and nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

TEX-HEU: Integral Experiment Execution with Polyethylene at Very Low Temperatures

The low-temperature variant of the TEX HEU (called Low-Temperature TEX or sometimes LT TEX) campaign is a highly anticipated and necessary experimental series by the greater nuclear science community. Fundamentally, the need for low-temperature integral experiments is required to perform validation of cross sections below room temperature. There has been substantial international interest in low-temperature benchmarks to validate below room temperature cross sections, namely talks given at the 2019 International Conference on Nuclear Criticality (ICNC): UK (Watson, 2019), France (Milin, 2019), and UK (Gan & Wilson, 2019). Additionally, NCSP funded thermal scattering laws (TSLs) were produced by North Carolina State University and require low-temperature benchmarks to validate them. Validation of low-temperature cross sections is also necessary for criticality safety applications. One particularly important application is to ensure that during transportation, fissile materials must remain subcritical under normal ambient conditions which is defined as temperatures down to -40°C/°F by the United States 10 CRF 71 as well as a regulation put forward by the International Atomic Energy Agency (IAEA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Verification and Validation Testing and Tools including Nuclear Criticality Safety Applications with the MCNP6.3® Code [Abstract]

A new Python-based framework has been developed to enable a more consistent layout with automatable setup, execution, and documentation of all verification and validation (V&V) test suites previously established for use with the MCNP code. In this paper, the new general framework for the V&V test suites is discussed, including information on all of the current capabilities and plans for future capabilities. For nuclear criticality safety applications, the existing V&V benchmark problems within the criticality, extended criticality, and analytic k-effective test suites have been ported into this new framework. In addition, the status and updates to the Rossi-alpha and subcritical multiplicationtest suites will be discussed. Some V&V results exercising new MCNP6.3 capabilities will be demonstrated.

97 MATHEMATICS AND COMPUTING↗

Neutronic-Thermal Hydraulic Benchmark using the SKINATH Point Kinetics Model

The SKINATH point kinetics program, whose name comes from: A Computer Program for Solving the Reactor Point Kinetics Equations with Simple Thermal Hydraulic-Feedback, had its origins at ORNL. The authors were interested in investigating low-level criticality events such as might occur in a waste repository of 55 gallon drums. We assume a relatively realistic thermal feedback for fissionable material in a container (called a reactor here), either critical or subcritical, with the potential to undergo a further excursion. The system is a homogeneous fissile fluid (mostly water), increasing in temperature as it absorbs all heat from the excursion. An ideal gas eternally cools the reactor at constant temperature T{sub c}. The SKINATH numerical concept in 1984 was to use an off-the-shelf Livermore ODE solver LSODE to solve the kinetic equations, much as one does today with MATLAB{sup TM}. Here, we develop a novel solver that uses the simplest of numerical methods including convergence acceleration. This work represents the initiation of a Multiphysics benchmark effort at INL. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Source Range Detector Response Modeling using VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary source assemblies, transfer of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous energy Monte Carlo solver Shift for final detector response evaluation. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data and found to be in very good agreement.

Gentry, Cole↗

Upper Subcritical Limit Calculations with Correlated Integral Experiments

The American National Standards Institute (ANSI) and American Nuclear Society (ANS) standard for Validation of Neutron Transport Methods for Nuclear Criticality Safety Calculations defines the Upper Subcritical Limit (USL) as “a limit on the calculated k effective value established to ensure that conditions calculated to be subcritical will actually be subcritical.” Often, USL calculations are based on statistical techniques that infer information about a nuclear system of interest (application) from a set of known/well characterized similar systems (experiments). In determining a USL, it is common to statistically determine a calculation bias and bias uncertainty. Bias is “the systematic difference between calculated results and experimental data.” The bias uncertainty is “the uncertainty that accounts for the combined effects of uncertainties in the benchmarks, the calculational models of the benchmarks, and the calculational methods.” Both the bias and the bias uncertainty are often inferred through statistical methods applied to the selected set of experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

S/U Comparison Study with a Focus on USLs

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize ENDF/B-VII.1. Four cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) were selected as application models: HEU-MET-FAST-013-001, HEU-SOL-THERM 001-008, PU-MET-FAST-022-001, and PU-SOL-THERM 001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL may be computed using bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS 8.24. Application of portions of MOS to the USL for nuclear data uncertainty of and potential code margin is referred to as USL herein. In either case, additional MOS is considered for actual application cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validating Mixtures of 233 U, 235 U, and 239 Pu for the Sum-of-Fractions Method

The Sum-of-Fractions method is a technique used to assure that homogeneous mixtures of fissile and fissionable isotopes are below a minimum margin of k eff or reactivity. Current work by Pacific Northwest National Laboratory examines different mixtures of 233 U, 235 U, and 239 Pu to determine critical mass limits for mixtures of transuranic actinides lacking a validation basis. To provide a validation basis for these limits, the work presented here describes the results of a sensitivity and uncertainty analysis of various mixtures of these isotopes in various concentrations moderated and reflected by light water and polyethylene. The TSUNAMI-1D sequence in the SCALE code system was used to generate sensitivity coefficients for three different concentrations of mixtures of 233 U, 235 U, and 239 Pu. The TSUNAMI-IP sequence was then used for similarity assessment (c k ) with critical benchmark experiment sensitivity data files (SDFs) from the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data and the Nuclear Energy Agency SDF database. The VADER sequence in SCALE was used for statistical testing and to generate upper subcritical limits from the data to develop a basis for validating critical mass limits.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of Critical Experiment Correlations Using the Sampler Sequence Within SCALE 6.2

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique.

42 ENGINEERING↗

Determination of critical experiment correlations using the sampler sequence within scale 6.2 - 14602

The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilities and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique. (authors)

42 ENGINEERING↗

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICSBEP evaluation lessons learned and good practice

This document describes lessons learned during my nearly 20 years of experience in International Criticality Safety Benchmark Evaluation Project (ICSBEP) meetings and in the development of several evaluations employing the IPEN/MB-01 reactor. The evaluations cover a wide range of possible configurations at the reactor core of this facility. Most of the evaluations are related to critical configurations, although two of them concern subcritical measurements. Examples of the evaluations submitted and approved for ICSBEP publication are the critical configurations employed in the standard core; critical configurations employing heavy reflectors composed of stainless steel, nickel, and carbon steel; and critical configurations employing the standard fuel rods and fuel rods composed of UO 2 -Gd 2 O 3 , among several others. Additionally, this document addresses good practices for the development of ICSBEP evaluations; the intention is to help beginners who are going to start evaluations for ICSBEP. The sections of the ICSBEP evaluation are described and illustrated with several examples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Secondary-Source Core Reload Modeling with VERA

The CASL reactor simulation package VERA has been adapted to provide high-fidelity simulation capabilities for modeling source range detector response during subcritical reactor configurations. New features include the activation and shuffling of secondary-source assemblies, use of burned fuel neutron emission data from the ORIGEN depletion solver to the MPACT deterministic neutron transport solver, allowance of user-defined sources in MPACT based on material composition, ability to solve the subcritical source-driven system with neutron multiplication using the MPACT diffusion solver, and transfer of the calculated fission source from MPACT to the continuous-energy Monte Carlo solver Shift for final detector response evaluation using the CADIS methodology for variance reduction. These new capabilities were benchmarked against Watts Bar Unit 1 plant operating data for the first few fuel loading steps and were found to demonstrate excellent agreement with the measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗