Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Unreliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Status of wind-energy conversion

The utilization of wind energy is technically feasible as evidenced by the many past demonstrations of wind generators. The cost of energy from the wind has been high compared to fossil fuel systems. A sustained development effort is needed to obtain economical systems. The variability of the wind makes it an unreliable source on a short-term basis. However, the effects of this variability can be reduced by storage systems or connecting wind generators to fossil fuel systems, hydroelectric systems, or dispersing them throughout a large grid network. The NSF and NASA-Lewis Research Center have sponsored programs for the utilization of wind energy.

Thomas, R. L.↗

Threat Agnostic Virulence Assessment of Pathogens

Virulence assessment of new, emerging, and engineered pathogens is critical to mounting an appropriate response to a biothreat agent. The capacity of the pathogen to colonize human and harm tissues must be characterized to understand pathogenicity pathways and optimize diagnosis and treatment of resulting disease. Respiratory pathogens are of interest because they can have high transmissibility rates, as observed with the SARS-CoV-2 virus, the causative agent of Covid-19. Current technologies are insufficient to assess threats due to their reliance on systems with only one cell type and on sequencing the pathogen. However, it is known that sequence is not an accurate predictor of function, and sequencing can be unreliable for newly emerged or engineered pathogens. An ideal system would consist of relevant epithelial cell types and an assay sensitive enough to detect changes in host responses that do not rely on DNA sequencing. We chose a system consisting of host lung epithelial cells that can be used to assess the virulence of unknown respiratory pathogens. We interrogated pathogens using this model and assess features of pathogenicity. Our objective is to leverage PNNLs strengths in tissue engineering and proteomics capabilities to build a multiple reaction monitoring (MRM) or parallel reaction monitoring (PRM) liquid chromatography-tandem mass spectrometry assay for human host cell proteins whose abundance is influenced by infection. These responses can were then assessed for relative virulence using pathogen agnostic signatures. When confronted with a pathogen, cells activate dedicated signaling pathways, typically through phosphorylation of regulatory proteins and downstream activation of host cell networks.

59 BASIC BIOLOGICAL SCIENCES↗

Composite Wavelet Filters for Enhanced Automated Target Recognition

Automated Target Recognition (ATR) systems aim to automate target detection, recognition, and tracking. The current project applies a JPL ATR system to low-resolution sonar and camera videos taken from unmanned vehicles. These sonar images are inherently noisy and difficult to interpret, and pictures taken underwater are unreliable due to murkiness and inconsistent lighting. The ATR system breaks target recognition into three stages: 1) Videos of both sonar and camera footage are broken into frames and preprocessed to enhance images and detect Regions of Interest (ROIs). 2) Features are extracted from these ROIs in preparation for classification. 3) ROIs are classified as true or false positives using a standard Neural Network based on the extracted features. Several preprocessing, feature extraction, and training methods are tested and discussed in this paper.

automated target recognition↗

Testing of a Composite Wavelet Filter to Enhance Automated Target Recognition in SONAR

Automated Target Recognition (ATR) systems aim to automate target detection, recognition, and tracking. The current project applies a JPL ATR system to low resolution SONAR and camera videos taken from Unmanned Underwater Vehicles (UUVs). These SONAR images are inherently noisy and difficult to interpret, and pictures taken underwater are unreliable due to murkiness and inconsistent lighting. The ATR system breaks target recognition into three stages: 1) Videos of both SONAR and camera footage are broken into frames and preprocessed to enhance images and detect Regions of Interest (ROIs). 2) Features are extracted from these ROIs in preparation for classification. 3) ROIs are classified as true or false positives using a standard Neural Network based on the extracted features. Several preprocessing, feature extraction, and training methods are tested and discussed in this report.

image processing↗

Enhanced Component Performance Study: Turbine Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period: The following decreasing trends were identified for TDPs for the most recent 10 year period: • Standby TDP FTR>1H failure rate • Normally running TDP FTR failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of start demands (demands per reactor year) • Standby TDP frequency of FTR=1H hours (hours per reactor year) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands • Normally running TDP frequency of run hours • Normally running TDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of turbine driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10 year period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Helicopter propulsion system reliability and engine monitoring assessments

The major short life, unreliable, and high maintenance engine and power components and subsystems in current civil helicopters were identified. Categories included both reciprocating and turbine engines, single and multiple engine configurations, single and tandem trotor vehicles, and light, medium, and heavy helicopters. The major focus was on the following parameters: accident rate data; maintenance rate data; and direct operator input.

Murphy, J. A.↗

Capillary-Driven Heat Transfer Experiment: Keeping It Cool in Space

Capillary-pumped loops (CPL's) are devices that are used to transport heat from one location to another--specifically to transfer heat away from something. In low-gravity applications, such as satellites (and possibly the International Space Station), CPL's are used to transfer heat from electrical devices to space radiators. This is accomplished by evaporating one liquid surface on the hot side of the CPL and condensing the vapor produced onto another liquid surface on the cold side. Capillary action, the phenomenon that causes paper towels to absorb spilled liquids, is used to "pump" the liquid back to the evaporating liquid surface (hot side) to complete the "loop." CPL's require no power to operate and can transfer heat over distances as large as 30 ft or more. Their reliance upon evaporation and condensation to transfer heat makes them much more economical in terms of weight than conventional heat transfer systems. Unfortunately, they have proven to be unreliable in space operations, and the explanation for this unreliability has been elusive. The Capillary-Driven Heat Transfer (CHT) experiment is investigating the fundamental fluid physics phenomena thought to be responsible for the failure of CPL's in low-gravity operations. If the failure mechanism can be identified, then appropriate design modifications can be developed to make capillary phase-change heat-transport devices a more viable option in space applications. CHT was conducted onboard the Space Shuttle Columbia during the first Microgravity Science Laboratory (MSL-1) mission, STS-94, which flew from July 1 to 17, 1997. The CHT glovebox investigation, which was conceived by Dr. Kevin Hallinan and Jeffrey Allen of the University of Dayton, focused on studying the dynamics associated with the heating and cooling at the evaporating meniscus within a capillary phase-change device in a low-gravity environment. The CHT experimental hardware was designed by a small team of engineers from Aerospace Design & Fabrication (ADF), the NASA Lewis Research Center, and the University of Dayton. The hardware consisted of two experiment modules that each contained an instrumented test loop (idealized capillary-pumped loop), a base unit for power conversion and backlighting, a display unit with 15 LED's (light-emitting diodes) to display temperatures, pressure, heater power, and time, a control unit to select heaters and heater settings, a cooling fan, and associated cables.

Lekan, Jack F.↗

Reliability Model Generator for fault-tolerant systems

This paper discusses an analysis tool, the Reliability Model Generator, that reasons from structural and functional system design specifications to generate a reliability model for the system under investigation. The resultant model defines a system state space sufficient to characterize the effects of single and multiple component failures. This model may then be examined by the analyst or used as input to an existing reliability evaluation tool, the Semi-Markov Unreliability Range Evaluator (SURE), to compute numeric bounds for system reliability (i.e., safety, mission success, availability, etc.). In defining the input to the Reliability Model Generator, a separation of the component function from structural specification is proposed to allow easy modification for analysis of alternative architectures. A hierarchical system description paradigm promotes multiple abstractions, thereby enabling analysis at all phases of the design process. The work described in this paper has been supported under NASA contract NAS1-10899, Integrated Airframe/Propulsion Control System Architecture (IAPSA II). IAPSA II promotes a system engineering methodology and supporting analytical tools to evaluate flight control architecture configuration alternatives during early phases of the design cycle when the cost and schedule impact of design revisions is minimal. Emphasis is placed on traceability to ensure that the requirements drive the resulting design.

Catherine M McCann↗

Reliability Analysis for AFTI-F16 SRFCS Using ASSIST and SURE

This paper reports the results of a study on reliability analysis of an AFTI-16 Self-Repairing Flight Control System (SRFCS) using software tools SURE (Semi-Markov Unreliability Range Evaluator and ASSIST (Abstract Semi-Markov Specification Interface to the SURE Tool). The purpose of the study is to investigate the potential utility of the software tools in the ongoing effort of the NASA Aviation Safety Program, where the class of systems must be extended beyond the originally intended serving class of electronic digital processors. The study concludes that SURE and ASSIST are applicable to reliability, analysis of flight control systems. They are especially efficient for sensitivity analysis that quantifies the dependence of system reliability on model parameters. The study also confirms an earlier finding on the dominant role of a parameter called a failure coverage. The paper will remark on issues related to the improvement of coverage and the optimization of redundancy level.

Wu, N. Eva↗

Semi-Markov Unreliability Range Evaluator (SURE)

Analysis tool for reconfigurable, fault-tolerant systems, SURE provides efficient way to calculate accurate upper and lower bounds for death state probabilities for large class of semi-Markov models. Calculated bounds close enough for use in reliability studies of ultrareliable computer systems. Written in PASCAL for interactive execution and runs on DEC VAX computer under VMS.

Butler, R. W.↗

The cost of unreliability in the avionics suite of a launch vehicle

The main objective of the Advanced Launch System (ALS) program is to realize a substantial reduction in recurring launch costs over present launch systems. A methodology is presented for assessing the impact of the reliability of the avionics suite on the recurring launch cost of the ALS. The methodology is illustrated by focusing on two architectures. The first is a distillation of a typical architecture for this type of application. The second is a simplified implementation of the Advanced Information Processing System (AIPS) technology developed at the Charles Stark Draper Laboratory, Inc. Both architectures utilize redundancy of hardware to tolerate faults. the key contributors to the cost of unreliability are identified and modeled utilizing Markov modeling techniques for each of the two architectures. The results are presented along with the more traditional costs for these avionics suites.

Rosch, Gene↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation-based inference for parameter estimation of complex watershed simulators

High-resolution, spatially distributed process-based (PB) simulators are widely employed in the study of complex catchment processes and their responses to a changing climate. However, calibrating these PB simulators using observed data remains a significant challenge due to several persistent issues, including the following: (1) intractability stemming from the computational demands and complex responses of simulators, which renders infeasible calculation of the conditional probability of parameters and data, and (2) uncertainty stemming from the choice of simplified representations of complex natural hydrologic processes. Here, we demonstrate how simulation-based inference (SBI) can help address both of these challenges with respect to parameter estimation. SBI uses a learned mapping between the parameter space and observed data to estimate parameters for the generation of calibrated simulations. To demonstrate the potential of SBI in hydrologic modeling, we conduct a set of synthetic experiments to infer two common physical parameters – Manning's coefficient and hydraulic conductivity – using a representation of a snowmelt-dominated catchment in Colorado, USA. We introduce novel deep-learning (DL) components to the SBI approach, including an “emulator” as a surrogate for the PB simulator to rapidly explore parameter responses. We also employ a density-based neural network to represent the joint probability of parameters and data without strong assumptions about its functional form. While addressing intractability, we also show that, if the simulator does not represent the system under study well enough, SBI can yield unreliable parameter estimates. Approaches to adopting the SBI framework for cases in which multiple simulator(s) may be adequate are introduced using a performance-weighting approach. The synthetic experiments presented here test the performance of SBI, using the relationship between the surrogate and PB simulators as a proxy for the real case.

54 ENVIRONMENTAL SCIENCES↗

Flight critical system design guidelines and validation methods

Efforts being expended at NASA-Langley to define a validation methodology, techniques for comparing advanced systems concepts, and design guidelines for characterizing fault tolerant digital avionics are described with an emphasis on the capabilities of AIRLAB, an environmentally controlled laboratory. AIRLAB has VAX 11/750 and 11/780 computers with an aggregate of 22 Mb memory and over 650 Mb storage, interconnected at 256 kbaud. An additional computer is programmed to emulate digital devices. Ongoing work is easily accessed at user stations by either chronological or key word indexing. The CARE III program aids in analyzing the capabilities of test systems to recover from faults. An additional code, the semi-Markov unreliability program (SURE) generates upper and lower reliability bounds. The AIRLAB facility is mainly dedicated to research on designs of digital flight-critical systems which must have acceptable reliability before incorporation into aircraft control systems. The digital systems would be too costly to submit to a full battery of flight tests and must be initially examined with the AIRLAB simulation capabilities.

Holt, H. M.↗